Citations

Showing 10 of 108081 citations.

Primary cutaneous gamma/delta T‐cell lymphoma with simultaneous JAK2 and TP63 rearrangements: a new double‐hit?
Fadl, Amr, Comfere, Nneka I. , Greipp, Patricia T. , Feldman, Andrew L. , Feldman, Andrew L , Greipp, Patricia T , Bennani, N. Nora , Durani, Urshila

Mayo Clinic

Histopathology | June 13, 2023 | Volume: 83 | Issue: 3 | Pages: 492-495

10.1111/his.14973 | PMID 37308177 Get It

ON THE DESIGN OF A NOVEL PHONOENTEROGRAM SENSING DEVICE USING AI ASSISTED COMPUTER-AIDED AUSCULTATION
Damani, Shivam, Damani, Devanshi N. , Redij, Renisha, Sethi, Arshia , Muddaloor, Pratyusha, Kapoor, Anoushka, Rajagopal, Anjali , Gopalakrishnan, Keerthy, Chedid, Victor , Ryu, Alexander J. , Aakre, Christopher A. , Arunachalam, S P , Chedid, Victor G , Wang, Xiao‐Jing , Ryu, Alexander J. , Arunachalam, Shivaram P.

Mayo Clinic

2023 Design of Medical Devices Conference | June 12, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2023-7977 Get It

Abstract Bowel sounds have been previously used to study intestinal motility and overall digestive health in various clinical settings. However, the blurred definition of bowel sounds and their subtypes, limited resources for interpretation, poor sensitivity, and low positive predictive value led to their restricted utility. Recent advances in artificial intelligence and machine learning have steered interest in developing unique tools using the phonoenterogram to analyze diverse bowel sounds. In our study, bowel sounds were recorded from eight healthy volunteers using the Eko Duo stethoscope. A novel deep-learning algorithm was designed to classify the recordings into baseline or prominent bowel sounds. A total of 11,210 data points (5,605 balanced sounds) were used to train and test the model to yield an accuracy of 0.895, a precision of 0.890, and a recall of 0.854 reflecting successful segregation of these sounds into respective groups. More extensive studies enrolling healthy and diseased subjects with a device specifically tailored to record bowel sounds are needed to generalize these results and determine their application in the patient population.
A CASE STUDY ON ACTIVATION LEVEL OF ROTATOR CUFF MUSCLES USING ELECTROMYOGRAPHY AND ASSOCIATED MUSCLE FORCES
Mitchell, Allyson, MajidiRad, AmirHossein , Mitchell, Allyson, Pujalte, George G.A.

Mayo Clinic

2023 Design of Medical Devices Conference | June 12, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2023-7918 Get It

Abstract Rotator cuff tears are among the most common shoulder injuries, making them an attractive topic of study. Yet, there is a lack of clear understanding of attributes associated with deep and superficial muscles when it is intended to study the recovery progress after rehabilitation. Through a systematic approach, this project investigates the activation of rotator cuff muscles using surface electromyography (sEMG) sensors. The team developed a strategic plan to investigate the precision of the NORAXON technology that is utilized in this study to ensure that it is capable of capturing small variations in shoulder motion. This is followed by a reliability analysis to ascertain reproducibility of the experiment. The levels of muscle activities for superficial and deep muscles are monitored to explore the impact of traditionally prescribed arm movements used for the rehabilitation of rotator cuff injuries. Furthermore, an analysis of forces generated in the muscles is done to provide better insight into the activation levels of rotator cuff muscles. The results were promising, with a competent technology and acceptable correlation associated with muscle activities across all subjects. Four common arm movements were studied; scaption generated a significant response in the targeted muscles, particularly of the supraspinatus. Results were conclusive across all subjects, and simulation also supported the experiment showing high activation levels for the supraspinatus. The teres minor also showed a significant contribution when performing external rotation at 90⁰ abduction. The outcome of this study is significant for this ongoing project as it identifies the most impactful exercises that ensure targeted muscles are being triggered. It also lays the groundwork for expanding the project to a clinical study focusing on the most effective arm movements in order to improve rehabilitation process and reduce pertinent cost.
Concurrent measurement of perfusion parameters related to small blood vessels and cerebrospinal fluid circulation in the human brain using dynamic dual‐spin‐echo perfusion MRI
Cao, Di , Sun, Yuanqi , Li, Yinghao , Pillai, Jay J. , Qiao, Ye , Knutsson, Linda , Sun, Yang-bai , Su, Pan , Knutsson, Linda , Pillai, Jay J , Sun, Yuanqi , Hua, Jun , Lu, Hanzhang , Zijl, Peter C.M. van

Mayo Clinic

NMR in Biomedicine | June 12, 2023 | Volume: 36 | Issue: 10 | Pages: No page available

10.1002/nbm.4984 | PMID 37308297 Get It

AbstractAccumulating evidence from recent studies has indicated the importance of studying the interaction between the microvascular and lymphatic systems in the brain. To date, most imaging methods can only measure blood or lymphatic vessels separately, such as dynamic susceptibility contrast (DSC) MRI for blood vessels and DSC MRI‐in‐the‐cerebrospinal fluid (CSF) (cDSC MRI) for lymphatic vessels. An approach that can measure both blood and lymphatic vessels in a single scan offers advantages such as a halved scan time and contrast dosage. This study attempts to develop one such approach by optimizing a dual‐echo turbo‐spin‐echo sequence, termed “dynamic dual‐spin‐echo perfusion (DDSEP) MRI”. Bloch simulations were performed to optimize the dual‐echo sequence for the measurement of gadolinium (Gd)‐induced blood and CSF signal changes using a short and a long echo time, respectively. The proposed method furnishes a T1‐dominant contrast in CSF and a T2‐dominant contrast in blood. MRI experiments were performed in healthy subjects to evaluate the dual‐echo approach by comparing it with existing separate methods. Based on simulations, the short and long echo time were chosen around the time when blood signals show maximum difference between post‐ and pre‐Gd scans, and the time when blood signals are completely suppressed, respectively. The proposed method showed consistent results in human brains as previous studies using separate methods. Signal changes from small blood vessels occurred faster than from lymphatic vessels after intravenous Gd injection. In conclusion, Gd‐induced signal changes in blood and CSF can be detected simultaneously in healthy subjects with the proposed sequence. The temporal difference in Gd‐induced signal changes from small blood and lymphatic vessels after intravenous Gd injection was confirmed using the proposed approach in the same human subjects. Results from this proof‐of‐concept study will be used to further optimize DDSEP MRI in subsequent studies.
ARRHYTHMIC SUDDEN DEATH SURVIVAL PREDICTION MODEL FOR HYPERTROPHIC CARDIOMYOPATHY PATIENTS: AN INTERPRETABLE MACHINE LEARNING ANALYSIS
Farahani, Nasibeh Zanjirani , Enayati, Moein , Pumarejo, Andredi, Aguirre, Mateo Alzate , Siontis, Konstantinos C. , Bos, Martijn, Ackerman, Michael J. , Arruda‐Olson, Adelaide M. , Bos, J. Martijn , Bos, Johan M , Scott, Christopher G. , Geske, Jeffrey B.

Mayo Clinic

2023 Design of Medical Devices Conference | June 12, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2023-2989 Get It

Abstract Hypertrophic Cardiomyopathy (HCM) is an inheritable heart disease with the highest rate of sudden cardiac death (SCD) in young adults. Implantable Cardioverter Defibrillator (ICD) therapy is recommended for HCM patients at high risk for SCD. Reviewing the recent clinical literature revealed the potential to improve the selection of candidates for ICD implantation. The current study uses information extracted from echocardiography reports to evaluate HCM patients with ICD and aims to provide a comparative insight into patients who benefited the most from the device therapy, including shock and anti-tachycardia pacing (ATP). The proposed interpretable machine learning approach has used the XGboost algorithm. The model’s performance was considered satisfactory, as evidenced by an accuracy score of 81% and an area under the receiver operating characteristic curve (AUC) value of 69% and SHapley Additive exPlanations (SHAP) identified common properties of HCM patients in each category and provided high-level reasoning and foundation for a clinical decision support tool.
BLOOD PRESSURE PREDICTION FROM PHOTOPLETHYSMOGRAM SIGNAL USING ARTIFICIAL INTELLIGENCE
Shinde, Rutuja, Manga, Manga, Muthavarapu, Neha, Gopalakrishnan, Keerthy, Aakre, Christopher A. , Ryu, Alexander J. , Arunachalam, S P , Ryu, Alexander J. , Arunachalam, Shivaram P.

Mayo Clinic

2023 Design of Medical Devices Conference | June 12, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2023-2769 Get It

Abstract Blood pressure measurement in current medical practice relies on manual methods with the most widely used modality being sphygmomanometers. Utilizing the principle of Photoplethysmography, it is possible to provide an accurate reading of one’s blood pressure through light signals and photodetector devices. This research paper introduces a new Artificial Intelligence driven approach to predict Blood pressure levels and classify them according to the updated ACC (American College of Cardiology) criteria as Normal, Elevated, Stage I, and II Hypertension from the given PPG signal values using Machine Learning Models. This research paper aims to accurately read the Systolic and Diastolic Blood Pressure using Artificial Intelligence, place them into the correct value bins and further prove that the blood pressure values differ based on different skin tones in different light wavelengths such as red, infrared, and green. Machine Learning models such as the Support Vector Machine have shown an accuracy of 70.58% for Systolic Blood Pressure and Decision Tree with an accuracy of 74.4% for Diastolic Blood Pressure classification. The models used in this research are Support Vector Machine, Decision Tree and K-Nearest Neighbor. This research study has future applications and extensions to predict blood pressure levels for patients with different skin tones under different light radiations and PPG signal readings. Neural Network models will be developed to compare the blood predictions from this work.
ITINERARY PREDICTIVE ANALYTICS: AI BASED SOFTWARE AS A MEDICAL DEVICE TO PREDICT PATIENTS’ FIRST VISIT ITINERARY FOR HEALTHCARE ADMINISTRATION
Damani, Shivam, Gopalakrishnan, Keerthy, Aedma, Keirthana, Muddaloor, Pratyusha, Ryu, Alexander J. , Aakre, Christopher A. , Arunachalam, S P , Chandrasekhara, Vinay , Ryu, Alexander J. , Arunachalam, Shivaram P.

Mayo Clinic

2023 Design of Medical Devices Conference | June 12, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2023-1597 Get It

Abstract Majority of hospitals still utilize manual methods for patient scheduling and predicting future appointments, resulting in longer wait times, hospital burnout and inadequate use of resources. A variety of avenues have been explored, including priority patient routing, tele-health, neural networks for improving ER efficiency, predicting no-shows, consultation duration variations, and optimizing operating room utilization. Addressing this issue, a study was conducted using 700 pre-visit notes of pancreatic patients to determine the requirement of endoscopic or biliary procedure. Through natural language processing and traditional or transfer learning algorithms, data could directly be sent to EPIC for nurses to assess in further decision making. Performance of the models was above average with the transfer learning method outperforming the traditional method. Although limited by less dataset and fewer circumstances to test the models on, the results exposed potential for future development with the possibility of patients reporting their chief concerns, in turn analyzed by algorithms, ultimately creating a smooth and effective patient itinerary.
ON THE DESIGN OF ULTRA-WIDE BAND ANTIPODAL VIVALDI ANTENNA FOR BIOMEDICAL SENSORS
Samaddar, Poulami , Nusrat, Tasin , Gaddam, Sunil , Leggett, Cadman L. , Mitra, Dipankar , Arunachalam, S P , Leggett, Cadman L , Dey, Shuvashis , Roy, Sayan , Arunachalam, Shivaram P.

Mayo Clinic

2023 Design of Medical Devices Conference | June 12, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2023-2982 Get It

Abstract Designing an effective antenna is very important to utilize microwave imaging. A high gain antipodal antenna designed with ultra-wideband frequency range is presented here. The simulated results are validated with measured data. The antenna can operate within the Ultra band frequency range of 3 to 8 GHz. The maximum gain of 2.96 dBi is obtained at 4 GHz. An experiment with biological tissues is also done to show the effectiveness of the antenna using as a resonator.
COUGH AUDIO SENTIMENT ANALYTICS FOR SOFTWARE AS A MEDICAL DEVICE APPLICATIONS
Damani, Shivam, Sethi, Arshia , Baraskar, Bhavana , Gopalakrishnan, Keerthy, Agarwal, Joshika, Albitar, Hasan Ahmad Hasan , Ahluwalia, Vaibhav, DONLINGER, SUE, Arunachalam, S P , Iyer, Vivek , Arunachalam, Shivaram P.

Mayo Clinic

2023 Design of Medical Devices Conference | June 12, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2023-1316 Get It

Abstract Chronic cough is not only one of the leading causes of seeking healthcare all over the world but also a huge emotional drain on the affected patient population. In this study, we used 24-hour cough recordings to analyze the intervening conversations for sentiment analyses to better diagnose, guide, and manage treatment in such patients. We surveyed a cough clinic and selected four subjects with active cough complaints using relevant ICD-10 codes. Subjects were given and instructed to wear a device to record cough for 24 hours and the recordings were collected at weeks 0, 4, 8, and 12 of the treatment. The collected data was preprocessed to eliminate sections with no data (sleep, silence) and the number of coughs was counted. Google search API calls were used to transcribe the audio files and NLTK’s VADER analyzer was used to classify sentiments on a scale of 0 to 1. Finally, average scores were calculated and plotted over a graph to interpret any trends. 12 weeks of cough treatment had varied results on the four subjects. We categorized the exhibited sentiments into negative, neutral, positive, and compound and noted that they also showed no general trends. Among these, the compound sentiment displayed the most erratic patterns, and the obtained results could not generate a steady trend. Further studies are required with a large cohort to collect data over a longer duration to accurately analyze the sentiments associated with chronic cough.
AI BASED GLAND DETECTION IN BARRETT’S ESOPHAGUS USING OPTICAL COHERENCE TOMOGRAPHY FOR CAPSULE ENDOSCOPY DEVICE
Modi, Vaishnavi K., Redij, Renisha, Gadam, Srikanth , Gopalakrishnan, Keerthy, Rajagopal, Anjali , Leggett, Cadman L. , Arunachalam, S P , Leggett, Cadman L , Gadam, Srikanth , Lee, Jieun , Arunachalam, Shivaram P.

Mayo Clinic

2023 Design of Medical Devices Conference | June 12, 2023 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1115/dmd2023-1691 Get It

Abstract Optical coherence tomography (OCT) is an advanced imaging modality to detect Barrett’s esophagus (BE) dysplasia, providing widefield, cross-sectional imaging and microscopic resolution. BE dysplasia is characterized under OCT by the presence and number of glandular structures with atypical morphology. Accurate detection and interpretation of BE glands under OCT is essential to detect dysplastic lesions. Object Detection using deep learning has the potential to identify glands from OCT images. We developed a YOLO model to identify the presence of glands in BE tissue. The YOLOv4 object detector was trained on a custom BE dataset of 30 patients with confirmed BE who underwent OCT imaging, of which 222 OCT images included at least one gland. Our model identified glands with a high average precision of 88.79% on the test dataset. We showed that the developed model is robust to rotation, brightness, and blur in images. We have implemented an object detection model to identify glands from OCT images with promising results accurately. This model has the potential to improve the diagnosis and surveillance of BE by eliminating human error and missed dysplastic lesions adaptable for capsule endoscopy applications.