Citations

Clear

47 citation(s) found for "Scott, Luis".

Ventricular Arrhythmia Mortality in Patients with Heart Failure in the United States: Are There Differences Based on Race and Geography?
Tan, Min Choon , San, Boon Jian , Z, Justin Lee, Cha, Yong‐Mei , Scott, Luis R. , Sorajja, Dan , Russo, Andrea M. , Tan, Min C

Mayo Clinic

No container title available | March 31, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.171188076.69214399/v1 Get It

Long‐term outcomes with abandoning versus extracting sterile leads: A 10‐year population‐based study
Lee, Justin Z. , Talaei, Fahimeh , Sorajja, Dan , Valverde, Arturo M. , Scott, Luis R. , Asirvatham, Samuel J. , Kusumoto, Fred , Mulpuru, Siva K. , Cha, Yong‐Mei , Tan, Min Choon , Valverde, Arturo, Asirvatham, Samuel J , Kusumoto, Fred M , Cha, Yong-Mei , Srivathsan, Komandoor

Mayo Clinic

Pacing and Clinical Electrophysiology | March 16, 2024 | Volume: 47 | Issue: 5 | Pages: 626-634

10.1111/pace.14940 | PMID 38488756 Get It

Abstract Background Long‐term outcomes of sterile lead management strategies of lead abandonment (LA) or transvenous lead extraction (TLE) remain unclear. Methods We performed a retrospective study of a population residing in southeastern Minnesota with follow‐up at the Mayo Clinic and its health systems. Patients who underwent LA or TLE of sterile leads from January 1, 2000, to January 1, 2011, and had follow‐up for at least 10 years or until their death were included. Results A total of 172 patients were included in the study with 153 patients who underwent LA and 19 who underwent TLE for sterile leads. Indications for subsequent lead extraction arose in 9.1% ( n = 14) of patients with initial LA and 5.3% ( n = 1) in patients with initial TLE, after an average of 7 years. Moreover, 28.6% of patients in the LA cohort who required subsequent extraction did not proceed with the extraction, and among those who proceeded, 60% had clinical success and 40% had a clinical failure. Subsequent device upgrades or revisions were performed in 18.3% of patients in the LA group and 31.6% in the TLE group, with no significant differences in procedural challenges (5.2% vs. 5.3%). There was no difference in 10‐year survival probability among the LA group and the TLE group ( p = .64). Conclusion An initial lead abandonment strategy was associated with more complicated subsequent extraction procedures compared to patients with an initial transvenous lead extraction strategy. However, there was no difference in 10‐year survival probability between both lead management approaches.
The prognostic value of artificial intelligence to predict cardiac amyloidosis in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement
Pereyra, Milagros , Mahmoud, Ahmed K., Galasso, Francesca , Killian, Michael , Suppah, Mustafa, Kenyon, Courtney , Koepke, Laura, Padang, Ratnasari , Sweeney, John P., Fortuin, F. David , Eleid, Mackram F. , Steidley, D. Eric , Scott, Luis R. , Grogan, Martha , Rosenthal, Julie , Mahmoud, Ahmed , Pereyra, Milagros , Killian, Michael E, Kenyon, Courtney R, Koepke, Laura M, Padang, Ratnasari , Steidley, David E, Lopez-Jimenez, Francisco , Rosenthal, Julie L., Mahmoud, Ahmed K , Farina, Juan M. , Scalia, Isabel G. , Chao, Chieh‐Ju , Sell‐Dottin, Kristen , Fonseca, Rafaël , López-Jiménez, Francisco , Attia, Zachi I. , Dispenzieri, Angela , Arsanjani, Reza

Mayo Clinic

European Heart Journal - Digital Health | March 11, 2024 | Volume: 5 | Issue: 3 | Pages: 295-302

10.1093/ehjdh/ztae022 | PMID 38774378 Get It

Abstract Aims Cardiac amyloidosis (CA) is common in patients with severe aortic stenosis (AS) undergoing transcatheter aortic valve replacement (TAVR). Cardiac amyloidosis has poor outcomes, and its assessment in all TAVR patients is costly and challenging. Electrocardiogram (ECG) artificial intelligence (AI) algorithms that screen for CA may be useful to identify at-risk patients. Methods and results In this retrospective analysis of our institutional National Cardiovascular Disease Registry (NCDR)-TAVR database, patients undergoing TAVR between January 2012 and December 2018 were included. Pre-TAVR CA probability was analysed by an ECG AI predictive model, with >50% risk defined as high probability for CA. Univariable and propensity score covariate adjustment analyses using Cox regression were performed to compare clinical outcomes between patients with high CA probability vs. those with low probability at 1-year follow-up after TAVR. Of 1426 patients who underwent TAVR (mean age 81.0 ± 8.5 years, 57.6% male), 349 (24.4%) had high CA probability on pre-procedure ECG. Only 17 (1.2%) had a clinical diagnosis of CA. After multivariable adjustment, high probability of CA by ECG AI algorithm was significantly associated with increased all-cause mortality [hazard ratio (HR) 1.40, 95% confidence interval (CI) 1.01–1.96, P = 0.046] and higher rates of major adverse cardiovascular events (transient ischaemic attack (TIA)/stroke, myocardial infarction, and heart failure hospitalizations] (HR 1.36, 95% CI 1.01–1.82, P = 0.041), driven primarily by heart failure hospitalizations (HR 1.58, 95% CI 1.13–2.20, P = 0.008) at 1-year follow-up. There were no significant differences in TIA/stroke or myocardial infarction. Conclusion Artificial intelligence applied to pre-TAVR ECGs identifies a subgroup at higher risk of clinical events. These targeted patients may benefit from further diagnostic evaluation for CA.
Effect of age on in‐hospital outcomes of transvenous lead extraction for infected cardiac implantable electronic device
Tan, Min Choon , Ang, Qi Xuan , Yeo, Yong Hao , Thong, Jia Yean, Tolat, Aneesh , Scott, Luis R. , Lee, Justin Z. , Yeo, Yong Hao , Tan, Min C

Mayo Clinic

Pacing and Clinical Electrophysiology | February 7, 2024 | Volume: 47 | Issue: 4 | Pages: 577-582

10.1111/pace.14939 | PMID 38319639 Get It

AbstractBackgroundThe real‐world data on the safety profile of transvenous lead extraction (TLE) for infected cardiac implantable electronic devices (CIED) among elderly patients is not well‐established. This study aimed to evaluate the hospital outcomes between patients of different age groups who underwent TLE for infected CIED.MethodUsing the Nationwide Readmissions Database, our study included patients aged ≥18 years who underwent TLE for infected CIED between 2017 and 2020. We divided the patients into four groups: Group A. Young (<50 years), Group B. Young intermediate (50–69 years old), Group C. Older intermediate (70–79 years old), and Group D. Octogenarian (≥80 years old). We then analyzed the in‐hospital outcome and 30‐day readmission between these age groups.ResultsA total of 10,928 patients who were admitted for TLE of infected CIED were included in this study: 982 (9.0%) patients in group A, 4,234 (38.7%) patients in group B, 3,204 (29.3%) patients in group C and 2,508 (23.0%) of patients in group D. Our study demonstrated that the risk of early mortality increased with older age (Group B vs. Group A: OR: 1.92, 95% CI: 1.19‐3.09, p < .01; Group C vs. Group A: OR: 2.47, 95% CI: 1.51‐4.04, p < .01; Group D vs. Group A: OR: 2.82, 95% CI: 1.69‐4.72, p < .01). The risk of non‐home discharge also increased in elderly groups (Group B vs. Group A: OR: 1.89; 95% CI: 1.52‐2.36; p < .01; Group C vs. Group A: OR: 2.82; 95% CI 2.24‐3.56; p < .01; Group D vs. Group A: OR: 4.16; 95% CI: 3.28‐5.28; p < .01). There was no significant difference in hospitalization length and 30‐day readmission between different age groups. Apart from a higher rate of open heart surgery in group A, the procedural complications were comparable between these age groups.ConclusionElderly patients had worse in‐hospital outcomes in early mortality and non‐home discharge following the TLE for infected CIED. There was no significant difference between elderly and non‐elderly groups in prolonged hospital stay and 30‐day readmission. Elderly patients did not have a higher risk of procedural complications.
Abstract 14956: Outcomes of Leadless Pacemaker Implantation Following Transvenous Lead Removal of Infected Cardiac Implantable Electronic Device: A Systematic Review
Tan, Jian Liang , Tay, Soon Tzeh, Sorajja, Dan , Scott, Luis R. , Cha, Yong‐Mei , Russo, Andrea M. , Hussein, Ayman A. , Tan, Min Choon , Tay, Soon-Tzeh , Lee, Justin

Mayo Clinic

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.14956 Get It

Background: The outcomes of leadless pacemaker (LP) implantation after transvenous lead removal (TLR) of infected cardiac implantable electronic devices (CIED) are not well-established. Objective: This study sought to describe the outcomes of LP implantation following TLR of infected CIED. Method: We conducted a literature search using PubMed and Embase for a combination of term including leadless pacemaker implantation, transvenous lead extraction, transvenous lead removal , transvenous lead explant , infected cardiac implantable electronic device . The inclusion criterion was LP implantation after TLR of infected CIED. The exclusion criterion was TLR for non-infectious reason. Study end-points were procedural complications and LP infection. Result: Of 132 publications reviewed, 13 studies with a total of 253 patients (74 ± 14 years of age, 69% males) were included. Amongst, 56.8% had systemic CIED infection and 43.2% had isolated pocket infection. Staphylococcus Aureus was the most common causative organism in 33% of the reported patients. Of 253 patients included, 105 patients (41.5%) underwent concomitant LP implantation during TLR procedure, and 36 patients (14.2%) had transvenous pacing as a bridge from TLR to LP implantation. During the LP implantation, 1 patient (0.4%) had an intra-procedural complication requiring sternotomy. Post-LP implantation, 2 patients (0.8%) developed groin hematoma, 2 patients (0.8%) developed femoral arteriovenous fistula, and 1 patient (0.4%) developed pericardial effusion requiring pericardiocentesis. During a mean follow-up of 11.3 ±10.6 months, 3 patients (1.2%) developed pacemaker syndrome, 1 patient (0.4%) developed acute on chronic heart failure exacerbation, and only 1 patient (0.4%) developed LP-related infection requiring LP retrieval. Conclusion: This study suggests that LP implant is feasible and safe post-removal of infected CIED with cumulative adverse events at 4% and a reinfection rate of 0.4%.
Abstract 12679: Thirty-Day Readmissions for Recurrent Ventricular Tachycardia Following Catheter Ablation of Ventricular Tachycardia: Predictors and Outcomes
Ang, Qi Xuan , Deshmukh, Abhishek , Scott, Luis R. , Hussein, Ayman A. , Sroubek, Jakub , Wazni, Oussama M. , Tan, Min Choon , Yeo, Yong Hao , Santangeli, Pasquale , Lee, Justin

Mayo Clinic

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.12679 Get It

Background: Despite the optimal efficacy of catheter ablation for ventricular tachycardia (VT), recurrence of VT can occur post-procedurally. However, data on the high-risk population for VT recurrence and the in-hospital outcomes remain scarce. Objective: This study aimed to determine the predictors of 30-day readmission for recurrent VT after catheter ablation of VT and assess the in-hospital outcomes. Method: Using the all-payer, nationally representative Nationwide Readmissions Database, we identified the patients aged ≥18 years who underwent catheter ablation for VT and were readmitted within 30 days because of recurrent VT from 2017 to 2020. We performed unweighted univariable and multivariable analyses to determine the outcomes and to identify the patient and hospital variables that were predictive of 30-day readmissions for recurrent VT. A p-value of <0.05 is considered statistically significant. Results: In our analysis, a total of 4,102 patients were discharged alive after VT ablation, of which 278 (6.8%) were readmitted within 30 days for recurrent VT. Recurrent VT was also the most common cause of 30-day readmission (47.7%, n=278/583). Compared to non-recurrent VT readmission, readmission due to recurrent VT had higher mortality during rehospitalization (7.55% vs 3.72%, p<0.01) and higher cumulative hospitalization cost ($57584 vs $37846, p<0.01). Via multivariable analysis, congestive heart failure (aOR: 1.84; 95% CI: 1.07-3.17; P=0.03) and non-elective index admissions (aOR: 1.88; 95% CI: 1.32-2.68; P<0.01) were the independent predictors of 30-day readmission for recurrent VT. Conclusion: Recurrent VT was the most common cause of 30-day readmission following VT ablation. Congestive heart failure and non-elective index admissions were the independent predictors of 30-day readmissions for recurrent VT. These highlight the importance of further research in ablation strategies to improve the efficacy of VT ablation.
Adverse events in cryoballoon ablation for pulmonary vein isolation: Insight from the Food and Drug Administration Manufacturer and User Facility Device Experience
Tan, Min Choon , Tan, Jian Liang , Lee, Wei Jun , Sorajja, Dan , Masry, Hicham El , Scott, Luis R. , Lee, Justin Z. , El Masry, Hicham , Tan, Min C , Srivathsan, Komandoor

Mayo Clinic

Journal of Arrhythmia | July 24, 2023 | Volume: 39 | Issue: 5 | Pages: 784-789

10.1002/joa3.12898 | PMID 37799789 Get It

AbstractBackgroundReal‐world clinical data on the adverse events related to the use of cryoballoon catheter for pulmonary vein isolation remains limited.ObjectiveTo report and describe the adverse events related to the use of Artic Front cryoballoon catheters (Arctic Front, Arctic Front Advance, and Arctic Front Advance Pro) reported in the Food and Drug Administration's (FDA) Manufacturers and User Defined Experience (MAUDE) database.MethodsWe reviewed all the adverse events reported to the FDA MAUDE database over a 10.7‐year study period from January 01, 2011 to September 31, 2021. All events were independently reviewed by two physicians.ResultsDuring the study period, a total of 320 procedural‐related adverse events reported in the MAUDE database were identified. The most common adverse event was transient or persistent phrenic nerve palsy (PNP), accounting for 48% of all events. This was followed by cardiac perforation (15%), pulmonary vein stenosis (8%), transient ischemic attack or stroke (6%), vascular injury (4%), transient or persistent ST‐elevation myocardial infarction (3%), hemoptysis (2%), pericarditis (2%), and esophageal ulcer or fistula (1%). There were six reported intra‐procedural death events as a result of cardiac perforation.ConclusionThe two most common procedural adverse events associated with cryoballoon ablation were PNP and cardiac perforation. All cases of procedural mortality were due to cardiac perforation.
Abstract 9696: Long-Term Outcomes With Abandoning versus Extracting Sterile Leads: A 10-Year Population-Based Study
Talaei, Fahimeh , Sorajja, Dan , Valverde, Arturo M. , Scott, Luis R. , Mulpuru, Siva K. , Cha, Yong‐Mei , Tan, Min Choon , Srivathsan, Komandoor , Asirvatham, Samuel J. , Kusumoto, Fred , Lee, Justin

Mayo Clinic

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.9696 Get It

Background: Long-term outcomes of lead management strategies of lead abandonment (LA) or transvenous lead extraction (TLE) during cardiac implantable electronic devices (CIED) procedures requiring lead addition or replacement remain unclear. Hypothesis: We hypothesized that there is no difference in long-term (10-year) outcomes of LA versus TLE during CIED procedures requiring lead addition. Methods: We performed a retrospective cohort study of a population residing in seven adjacent counties of southeastern Minnesota with follow-up at the Mayo Clinic and its health systems. Patients who underwent LA or TLE for sterile leads from January 1, 2000, to January 1, 2011, and had follow-up for at least 10-years or until their death were included. Outcomes were identified through a detailed chart review of the electronic health record from within the Mayo Clinic system. Results: A total of 172 patients were included in the study with 153 patients who underwent LA and 19 who underwent TLE for sterile leads. In long-term follow-up, indications for subsequent lead extraction arose in 9.1% (n=14) of patients with initial LA and 5.3% (n=1) in patients with initial TLE, after an average of 7-years. Moreover, out of 14 patients, who required secondary extraction in the LA cohort, 28.6% did not proceed with the extraction. Of the remaining 10 patients, 60% had clinical success and 40% had a clinical failure with the extraction. Subsequent device upgrades or revisions were performed in 18.3% of patients in the LA group and 31.6% in the TLE group, with no significant differences in procedural challenges such as requiring balloon venoplasty or serial dilation (5.2% vs. 5.3%, P=1.0). There was no difference in 10-year survival probability among LA group and TLE group (P=0.64). Conclusion: Indications for subsequent extraction arose in 9.1% of patients with the initial LA approach for sterile leads after an average of 7.3 years and 28.6% did not proceed with the extraction. Of the patients who underwent the subsequent extraction, 60% had clinical success and 40% had a clinical failure. There was no difference in 10-year survival probability between patients with the initial LA approach or TLE approach.
Abstract 10913: Causes of Early Mortality After Catheter Ablation of Atrial Fibrillation
Deshmukh, Abhishek , Scott, Luis, Cha, Yong‐Mei , Mulpuru, Siva K. , Lee, Justin Z. , Tan, Min Choon , Rattanawong, Pattara , Srivathsan, Komandoor , McLeod, Christopher J. , Asirvatham, Samuel J. , Noseworthy, Peter A.

Mayo Clinic

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.10913 Get It

Background: Recognition of the causes of early mortality after atrial fibrillation (AF) catheter ablation is essential for the improvement of patient safety. Objective: This study sought to determine the causes of early mortality (≤90-days) after AF ablation and to further understand the circumstances surrounding death after the procedure. Methods: We performed a retrospective analysis of AF ablation from January 1, 2013, to December 1, 2021 at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a comprehensive chart review of the electronic health record from within the Mayo Clinic system and outside records when available. Results: A total of 6,723 patients were included in the study. The 30-day and 90-day all-cause mortality rates were 0.09% and 0.22%, respectively. Among all 90-day deaths, majority of the deaths (73.3%) did not have a direct relationship with the procedure. Sudden death was the most common cause of early death (20%), followed by peri-procedural stroke (13%), respiratory failure (13%), atrioesophageal fistula (13%), infection (7%), heart failure (7%), and traumatic brain injury (7%). The 90-day mortality rate directly due to AF ablation procedural complications was 0.06%. Most of the early deaths (93.3%) occurred after discharge from index hospitalization, among which 64.3% were readmitted before their death, 14% died at home, and 7% were discharged on comfort care and died in hospice. The main reason for readmission leading to death was respiratory failure (33%). Conclusion: Atrial fibrillation ablation procedure has a 90-day mortality of 0.22% and the most common cause of early mortality was sudden death. The majority (73.3%) of early mortality was not directly associated with a procedural complication, and the mortality rate due to complications associated with the AF ablation procedure was 0.06%.
Abstract 10571: Causes of Early Mortality After Catheter Ablation of Ventricular Tachycardia in Patients With Reduced Left Ventricular Ejection Fraction
Lee, Justin Z. , Deshmukh, Abhishek , Shen, Win K., Scott, Luis R. , Cha, Yong‐Mei , Mulpuru, Siva K. , Tan, Min Choon , Srivathsan, Komandoor , Masry, Hicham El , Asirvatham, Samuel J. , McLeod, Christopher J.

Mayo Clinic

Circulation | June 15, 2023 | Volume: 146 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.146.suppl_1.10571 Get It

Background: Recognition of the causes of early mortality after ventricular tachycardia (VT) ablation in patients with reduced left ventricular ejection fraction is an essential step toward improving post-procedural outcomes. Objective: This study sought to determine the causes of early mortality (≤30-days) after VT ablation in patients with reduced left ventricular ejection fraction and to understand further the circumstances surrounding death after the procedure. Methods: We performed a retrospective analysis of all patients undergoing VT ablation in patients with reduced left ventricular ejection fraction from January 1, 2013, to November 10, 2021, at the Mayo Clinic (Rochester, Phoenix, and Jacksonville). Causes of death were identified through a detailed chart review of the electronic health record within the Mayo Clinic system and outside records. Results: A total of 503 patients (mean age 63 ± 13 years, 11.2% female) with EF <50% were included in the study. The 30-day all-cause mortality rate was 5% (n=25), and the mortality rate due to a procedural complication was 0.4%. Among all 30-day deaths, recurrent VT was the most common primary cause of death (44%). This was followed by decompensated heart failure (28%), procedure-related death (8%), cerebrovascular accident (CVA) (4%), and infection (4%). Most patients (91%) who died from VT had the VT recurrence within three days of the ablation. 76% of patients with early mortality had delayed referral for VT ablation, and 72% opted for comfort care before death. Conclusions: The overall early mortality (≤30-days) rate after catheter ablation of VT in patients with reduced left ventricular ejection fraction was 5%, but the death rate directly due to a procedural complication was only 0.4%. The most common cause of death was recurrent VT, followed by heart failure. Further research into ablation strategies is vital to improving the safety, efficacy, and durability of VT ablation.