Citations

Clear

1414 citation(s) found for "Ross, CW".

Investigating the feasibility of 18F‐flortaucipir PET imaging in the antemortem diagnosis of primary age‐related tauopathy (PART): An observational imaging‐pathological study
Lavrova, Anna , Satoh, Ryota , Pham, Nha Trang Thu, Nguyen, Aivi T. , Jack, Clifford R. , Petersen, Ronald C. , Ross, Reichard R., Lowe, Val J. , Whitwell, Jennifer L. , Josephs, Keith A. , Lavrova, Anna , Jack, Clifford R , Nguyen, Aivi T , Satoh, Ryota , Ross, Reichard R., Dickson, Dennis W.

Mayo Clinic

Alzheimer's & Dementia | October 17, 2024 | Volume: 20 | Issue: 12 | Pages: 8605-8614

10.1002/alz.14301 | PMID 39417408 Get It

AbstractINTRODUCTIONPrimary age‐related tauopathy (PART) is characterized by neurofibrillary tangles and minimal β‐amyloid deposition, diagnosed postmortem. This study investigates 18F‐flortaucipir (FTP) PET imaging for antemortem PART diagnosis.METHODSWe analyzed FTP PET scans from 50 autopsy‐confirmed PART and 13 control subjects. Temporal lobe uptake was assessed both qualitatively and quantitatively. Demographic and clinicopathological characteristics and voxel‐level uptake using SPM12 were compared between FTP‐positive and FTP‐negative cases. Intra‐reader reproducibility was evaluated with Krippendorff's alpha.RESULTSMinimal/mild and moderate FTP uptake was seen in 32% of PART cases and 62% of controls, primarily in the left inferior temporal lobe. No demographic or clinicopathological differences were found between FTP‐positive and FTP‐negative cases. High intra‐reader reproducibility (α = 0.83) was noted.DISCUSSIONFTP PET imaging did not show a specific uptake pattern for PART diagnosis, indicating that in vivo PART identification using FTP PET is challenging. Similar uptake in controls suggests non‐specific uptake in PART.Highlights 18F‐flortaucipir (FTP) PET scans were analyzed for diagnosing PART antemortem. 32% of PART cases had minimal/mild FTP uptake in the left inferior temporal lobe. Similar to PART FTP uptake was found in 62% of control subjects. No specific uptake pattern was found, challenging in vivo PART diagnosis.
Longitudinal graphics of physical function and other patient-reported outcomes in patients treated for hematologic malignancies 
Thanarajasingam, Gita , Chen, Tingyu , Hoffman, Ron, Mascarenhas, John , Murugappan, Meena N. , Ross, Joseph F., Warsame, Rahma , Dueck, Amylou C. , Dueck, A. C. , Bhatnagar, Vishal , Noble, Brie N. , Fiero, Mallorie H. , Jeffery, Molly Moore , Mazza, Gina L , Mascarenhas, John , Mesa, Ruben A. , Ross, Joseph, Sidana, Surbhi , Kluetz, Paul Gustav

Mayo Clinic

No container title available | October 11, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-4888383/v1 Get It

Abstract Background The US Food and Drug Administration (FDA) released a draft guidance document detailing core patient-reported outcomes in cancer clinical trials, including physical function (PF). This study aimed to develop analytic methods and visualizations of patient-reported PF in patients with cancer. Methods We applied an estimand framework to a patient-reported tolerability endpoint to develop data summaries cross-sectionally and over time, along with visualizations. We accomplished this through iterative feedback with clinicians, statisticians, and FDA stakeholders using three clinical trial datasets in hematologic malignancies. Graphical approaches were applied to three datasets in hematologic malignancies: (1) patients with myeloproliferative neoplasms enrolled in MPN-RC 111/112 trials completed EORTC QLQ-C30 over 12 months; (2) patients with hematologic malignancies undergoing CAR-T cell therapy or autologous transplant who completed FACT questionnaires over 6 months; and (3) patients with multiple myeloma or amyloidosis who completed the PROMIS-29 questionnaire over 6 months. Zoom polls were administered to two stakeholder groups (clinicians/clinical investigators and patient advocates) to elicit feedback. Results Visualizations included stacked bar charts, line plots of arithmetic mean changes from baseline, pie charts, waffle plots, and waterfall plots of PF data. Graphics considered scaled scores and individual items and included delineation of PRO completion rate at each time point. Confidence intervals and reference lines were included as applicable, and colorblind accessible colors were implemented to ensure inclusivity of all visualizations. Data summaries over time reporting “worst” change were difficult to interpret. In terms of stakeholders’ preference, patients preferred stacked bar charts while clinicians equally favored stacked bar charts and line plots; both patients and clinicians preferred waterfall plots to pie charts. Patient feedback highlighted the need for various graphics to convey group level trends and granular individual-patient level information. Conclusion Patient-reported PF informs the evaluation of treatment tolerability in cancer trials. Data summaries and visualizations of physical function developed through an iterative process were reviewed favorably by patients, clinicians and FDA stakeholders in this study. Future work to systematically assess accuracy of interpretation of the various analytic and visualization methods is a necessary next step across clinical, regulatory, payer and patient stakeholders. Trial registration NCT01259817, NCT01259856
Kidney Outcomes with Glucagon-Like Peptide-1 Receptor Agonists, Sodium-Glucose Cotransporter 2 Inhibitors, Dipeptidyl Peptidase-4 Inhibitors, and Sulfonylureas in Type 2 Diabetes and Moderate Cardiovascular Risk
Neumiller, Joshua J. , Herrin, Jeph , Swarna, Kavya, Galindo, Rodolfo J. , Deng, Yihong , Ross, Joseph S. , Mickelson, Mindy M. , McCoy, Rozalina G. , Galindo, Rodolfo J , Ross, Joseph S , McCoy, Rozalina Grubina , Herrin, Jeph , Mickelson, Mindy M , Neumiller, Joshua J. , Polley, Eric C. , Umpierrez, Guillermo E. , Deng, Yihong

Mayo Clinic

Clinical Journal of the American Society of Nephrology | October 8, 2024 | Volume: 20 | Issue: 2 | Pages: 206-217

10.2215/cjn.0000000587 | PMID 39729347 Get It

Key Points Sodium-glucose cotransporter 2 inhibitors and glucagon-like peptide-1 receptor agonists were superior to dipeptidyl peptidase-4 inhibitor and sulfonylurea for preventing kidney complications in patients with type 2 diabetes at moderate cardiovascular disease risk. Sodium-glucose cotransporter 2 inhibitor therapy compared favorably with glucagon-like peptide-1 receptor agonists for kidney disease outcomes. Background CKD is a serious diabetes-related complication. While guidelines recommend use of sodium-glucose cotransporter 2 inhibitor (SGLT2i) and glucagon-like peptide-1 receptor agonist (GLP-1RA) therapies to mitigate cardiorenal risk in high-risk patients, the benefit of early initiation of these agents relative to other commonly prescribed glucose-lowering agents in patients at lower baseline cardiovascular disease (CVD) risk remains less clear. Methods This retrospective observational study emulated an idealized target trial using claims data from OptumLabs data warehouse to test the comparative association of treatment with a dipeptidyl peptidase-4 inhibitor (DPP-4i), SGLT2i, GLP-1RA, or sulfonylurea (SU) on a primary kidney composite outcome of incident CKD stages 3–5, kidney failure, or need for KRT in patients with type 2 diabetes and moderate CVD risk. A secondary composite outcome included all components of the primary composite outcome plus death. Results A total of 364,714 adults aged 21 years or older initiating treatment with a DPP-4i ( N =78,843), GLP-1RA ( N =42,049), SGLT2i ( N =45,466), or SU ( N =198,356) were identified. Relative to DPP-4i, SGLT2i (hazard ratio [HR], 0.71; 95% confidence interval [CI], 0.67 to 0.74; P < 0.001) and GLP-1RA (HR, 0.87; 95% CI, 0.83 to 0.92; P < 0.001) treatment was superior for the primary composite outcome. Similarly, SGLT2i (HR, 0.69; 95% CI, 0.66 to 0.73) and GLP-1RA (HR, 0.86; 95% CI, 0.82 to 0.91) treatment was associated with risk reductions for the primary outcome relative to SU treatment. When comparing SGLT2i with GLP-1RA therapy, SGLT2is were superior for the primary composite outcome (HR, 0.81; 95% CI, 0.75 to 0.86; P < 0.001). Similar findings were observed for the secondary composite outcome across all comparisons. Conclusions SGLT2is and GLP-1RAs were superior to DPP-4is and SUs for preventing kidney complications in a type 2 diabetes population with moderate baseline CVD risk. Clinical Trial registry name and registration number: NCT05214573.
B-231 Evaluation of the KingFisher Flex for DNA Isolation From FFPE Tissue Utilizing Autolys M Tubes and the MagMAX FFPE DNA/RNA Ultra Kit
Zuckerman, Eric Zimmerman , Caffes, Patricia L., Marta, Paz, Lockwood, Nicola , Dukek, Brian A. , Baumann, N, Rowsey, Ross, Knight, S, Milosevic, D, Lockwood, N

Mayo Clinic

Clinical Chemistry | October 2, 2024 | Volume: 70 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvae106.590 Get It

Abstract Background Our institution is facing increasing demand for oncology testing that requires high quality DNA extracted from formalin-fixed paraffin-embedded (FFPE) tissue. The current DNA extraction workflow involves a time and labor-intensive manual process that limits our ability to accommodate increasing downstream clinical testing volumes. We evaluated the KingFisher (KF) Flex utilizing Autolys M Tubes and the MagMAX FFPE DNA/RNA Ultra Kit as a possible high-throughput, automated DNA isolation workflow option that would decrease hands-on time and be conducive to volume growth without the need for additional staff. Methods DNA from 52 FFPE tissue samples (n=24 unique cases previously extracted by the current “manual method”) were extracted using Autolys M tubes, the MagMAX FFPE DNA/RNA Ultra Kit, and the KF Flex (Thermo Fisher Scientific Waltham, MA) over 4 “automated method” runs. Method modifications to the published procedure were introduced over the runs to determine any effects on DNA quality/quantity. Timings were taken during each run to compare hands-on and total run time against that of the manual method. Precision experiments were performed by extracting 4 replicates of sample on a single run (intra-assay precision) and 2 samples from 2 cases over 2 runs (inter-assay precision). Three cases were processed using varying tissue input levels to assess input-yield correlation. DNA yield was measured using HS dsDNA Qubit (Thermo Fisher Scientific, Waltham, MA). A subset of samples was tested by digital droplet PCR (ddPCR) (n=10), chromosomal microsomal microarray (CMA) (n=1), and next-generation sequencing (NGS) (n=3). Variants and QC metrics of the KF DNA were compared to those of the manual method DNA. Results The average total DNA yield was 3% lower from samples extracted following the manufacturer recommended KF procedure compared to matched samples extracted using the manual method (n=28 samples from 23 unique cases). A CV of 2.8% was observed in an intra-assay experiment (n=4 replicates from 1 case) and 3.0% in an average inter-assay experiment (n=2 replicates from 2 cases). There was a direct correlation between the tissue input amount (4 amounts of varied tissue input) and the total DNA yield (n=3 samples). We observed concordant fractional abundance values for ddPCR samples and concordant variant detection for NGS and CMA samples. We did not see a significant difference in the quality metrics tracked for any of the downstream testing assays. Conclusions This evaluation demonstrated that, as compared to our manual method, the automated method resulted in comparable DNA yields and downstream assay results. The incorporation of this automation would significantly increase our FFPE DNA extraction capacity without requiring additional staff while reducing hands-on time per run by about six hours. We would also be able to reduce ergonomic hazards related to tube cap manipulation, eliminate use of hazardous reagents, and leverage the plate format to better integrate extracted DNA into our clinical sample preparation workflows. These operational benefits highlight the value of automating high-throughput workflows.
B-232 One Year Post-Implementation Experience Using a Custom Designed DNA Contamination Detection Module for a Clinical Myeloid Neoplasm Next Generation Sequencing Assay
Dina, M A , Berry, P L, Koganti, Tejaswi , Artymiuk, Cody J. , Bessonen, Kurt, Kodah, M, Bailey, Baños, Daede, B C, Carlson, Robert G. , Ross, G C, Zoromski, R J, Paladino, Lorenzo , He, Rong , Viswanatha, David S., Balan, Jagadheshwar , Basu, S, Paladino, L P

Mayo Clinic

Clinical Chemistry | October 2, 2024 | Volume: 70 | Issue: Supplement_1 | Pages: No page available

10.1093/clinchem/hvae106.591 Get It

Abstract Background In complex automated clinical laboratory Next Generation Sequencing (NGS) workflows, numerous opportunities exist for contamination events to occur. For oncology testing applications, detection of these events is crucial for accurate results reporting. A contamination detection module (MICon) using microhaplotype (MH) regions and an in-house designed analysis model was developed for use in a NGS assay for myeloid neoplasms (NGSHM) [1]. Variant detection for NGSHM has a validated analytical sensitivity of 2% variant allele frequency (VAF). Gross contamination events can potentially cause erroneous false positive variant detection whereas true low VAF mutations may be masked and evade detection. The following study was performed to evaluate MICon module performance on samples processed over the course of a year. Methods MH regions contain highly conserved tandem single nucleotide polymorphisms (SNPs) with high global heterogeneity occurring within a 300-nucleotide span. From the work of Kidd et al [2], 27 MH regions covering 92 SNPs and spanning 16 chromosomes were selected for inclusion in the 47 gene NGSHM target-capture panel. Sequencing was performed on a NovaSeq 6000 and analyzed through an internal bioinformatics pipeline, which incorporates the MICon module. MICon uses a binary classification model incorporating VAFs from MH regions, number of MH genotypes, and the contamination estimation score from verifyBamID to compute a single value on a 0-100 scale. Scores &lt;50 are classified as non-contaminated and scores ≥50 require further investigation. Results The dataset was comprised of 10,990 samples. A total of 10,232 patient cases (93.1%) had non-contaminated MICon scores &lt;50. Control replicates accounted for 261 samples (2.4%). There were 497 patient cases (4.5%) with MICon scores ≥50. Of the 497 patient cases, 137 (27.6%) had undergone hematopoietic stem cell transplantation (HSCT) and 114 (22.9%) contained gross chromosomal abnormalities, representing iatrogenic or tumor biological factors. An additional 135 (27.2%) of cases were contaminated from laboratory processing errors, 45 (9.1%) occurred due to chemistry failures during run processing, and 66 (13.2%) had an undetermined cause for a high score, representing laboratory-related and unknown factors. Overall, the 135 laboratory processing errors detected accounted for 1.3% of patient cases analyzed by the laboratory. These cases were repeated, and the non-contaminated results were accurately reported. Conclusions Herein it was shown the implementation of MICon has improved patient safety over the course of a year. The 1.3% of patient cases identified as arising from laboratory processing errors were successfully reprocessed. While the overall rate of laboratory processing errors appears low, the absolute number can be significant in a high-volume test setting, despite reliance on highly automated processes. Value is added by MICon through identifying errors that could result in the release of inaccurate patient results. By detecting previously unrealized errors, MICon has become an invaluable asset to the NGSHM assay by enhancing patient laboratory testing safety. References: [1] Balan J, et al. MICon Contamination Detection Workflow for Next-Generation Sequencing Laboratories Using Microhaplotype Loci and Supervised Learning. J Mol Diagn. 2023;25(8):602-610. doi:10.1016/j.jmoldx.2023.05.001. [2] Kidd KK, et al. Selecting microhaplotypes optimized for different purposes. Electrophoresis. 2018;39(21):2815-2823. doi:10.1002/elps.201800092.
Addressing menopause symptoms in the primary care setting: opportunity to bridge care delivery gaps
Bevry, Mackenzie, Stogdill, Emily R., Lea, Catherine M., Lovaas, Anna M., Bailey, Kaitlyn J., Mara, Kristin C. , Dierkhising, Ross , Chaudhry, Rajeev , Kapoor, Ekta , Bevry, Mackenzie L, Taylor, Kathryn R, Mara, Kristin C , Taylor, Kathryn R., Faubion, Stephanie S. , Kapoor, Ekta

Mayo Clinic

Menopause | October 1, 2024 | Volume: 31 | Issue: 12 | Pages: 1044-1048

10.1097/gme.0000000000002439 | PMID 39352126 Get It

Abstract Objective Menopause symptoms affect quality of life and financial well-being but are often unaddressed in primary care clinics. Therefore, we evaluated the extent of menopause symptom documentation in electronic health records (EHRs) by primary health care professionals. Methods We retrospectively reviewed adult women who reported moderate or higher vasomotor symptoms on a Mayo Clinic survey conducted from March 1, 2021, through June 30, 2021. We then assessed adequacy of menopause symptom documentation in the EHRs of these women who had primary care visits during the survey period. We reviewed the percentage of documented vasomotor symptoms from May 1, 2019, through May 1, 2021. Results In the Mayo Clinic Health System—Northwest Wisconsin Region, 229 women self-reported moderate or higher vasomotor symptoms in the Mayo Clinic survey. Although only 23% of these women had vasomotor symptoms listed in the EHR clinical problem lists, 60% of these women had vasomotor symptoms documented in their clinic notes from the primary care visit. Approximately 6% of women reported hormone therapy use for management of menopause symptoms, and nearly 15% reported use of nonhormone prescription therapies for vasomotor symptoms. Conclusions A greater proportion of women in our study had EHR documentation of bothersome menopause symptoms than those reported in other studies, but vasomotor symptoms remain generally untreated. We need better methods for identifying midlife women with bothersome menopause symptoms in primary care clinics so that appropriate treatment options, including hormone therapy, can be discussed and offered.
Validation of a whole slide image management system for metabolic‐associated steatohepatitis for clinical trials
Pulaski, Hanna , Mehta, Shraddha S., Manigat, Laryssa, Kaufman, Stephanie, Hou, Hypatia, Nalbantoglu, ILKe , Zhang, Xuchen , Curl, Emily, Taliano, Ross , Glickman, Jonathan N. , Resnick, Murray B. , Patel, Neel , Taylor, Cristin , Montalto, Michael , Beck, Andrew H. , Wack, Katy, Wack, Katy E , Kaufman, Stephanie, Kim, Tae Hun , Torbenson, Michael , Bédossa, Pierre

Mayo Clinic

The Journal of Pathology: Clinical Research | September 19, 2024 | Volume: 10 | Issue: 5 | Pages: No page available

10.1002/2056-4538.12395 | PMID 39294925 Get It

AbstractThe gold standard for enrollment and endpoint assessment in metabolic dysfunction‐associated steatosis clinical trials is histologic assessment of a liver biopsy performed on glass slides. However, obtaining the evaluations from several expert pathologists on glass is challenging, as shipping the slides around the country or around the world is time‐consuming and comes with the hazards of slide breakage. This study demonstrated that pathologic assessment of disease activity in steatohepatitis, performed using digital images on the AISight whole slide image management system, yields results that are comparable to those obtained using glass slides. The accuracy of scoring for steatohepatitis (nonalcoholic fatty liver disease activity score ≥4 with ≥1 for each feature and absence of atypical features suggestive of other liver disease) performed on the system was evaluated against scoring conducted on glass slides. Both methods were assessed for overall percent agreement with a consensus “ground truth” score (defined as the median score of a panel of three pathologists’ glass slides). Each case was also read by three different pathologists, once on glass and once digitally with a minimum 2‐week washout period between the modalities. It was demonstrated that the average agreement across three pathologists of digital scoring with ground truth was noninferior to the average agreement of glass scoring with ground truth [noninferiority margin: −0.05; difference: −0.001; 95% CI: (−0.027, 0.026); and p < 0.0001]. For each pathologist, there was a similar average agreement of digital and glass reads with glass ground truth (pathologist A, 0.843 and 0.849; pathologist B, 0.633 and 0.605; and pathologist C, 0.755 and 0.780). Here, we demonstrate that the accuracy of digital reads for steatohepatitis using digital images is equivalent to glass reads in the context of a clinical trial for scoring using the Clinical Research Network scoring system.
The Impact of Point-of-Care Ultrasound-Guided Resuscitation on Clinical Outcomes in Patients With Shock: A Systematic Review and Meta-Analysis*
Basmaji, John , Arntfield, Robert , Desai, Karishma , Lau, Vincent , Lewis, Kimberley , Fiorini, Kyle , Slessarev, Marat , Leligdowicz, Aleks, Prager, Ross , Orozco, Nicolás , Meade, Maureen O. , Thabane, Lehana , Guyatt, Gordon, Jones, Philip M. , Thabane, Lehana , Rochwerg, Bram , Honarmand, Kimia , Leligdowicz, Aleksandra , Park, Brian H. , Wong, Michelle Y.S., Ball, Ian Michael , Guyatt, Gordon

Mayo Clinic

Critical Care Medicine | September 18, 2024 | Volume: 52 | Issue: 11 | Pages: 1661-1673

10.1097/ccm.0000000000006399 | PMID 39298556 Get It

OBJECTIVE: To determine the impact of point-of-care ultrasound (POCUS)-guided resuscitation on clinical outcomes in adult patients with shock. DATA SOURCE: We searched MEDLINE, Embase, and unpublished sources from inception to December 2023. STUDY SELECTION: We included randomized controlled trials (RCTs) that examined the use of POCUS to guide resuscitation in patients with shock. DATA EXTRACTION: We collected data regarding study and patient characteristics, POCUS protocol, control group interventions, and outcomes. DATA SYNTHESIS: We identified 18 eligible RCTs. POCUS slightly influences physicians’ plans for IV fluid (IVF) and vasoactive medication prescription (moderate certainty), but results in little to no changes in the administration of IVF (low to high certainty) or inotropes (high certainty). POCUS may result in no change in the number of CT scans performed (low certainty) but probably reduces the number of diagnostic echocardiograms performed (moderate certainty). POCUS-guided resuscitation probably reduces 28-day mortality (relative risk [RR] 0.88; 95% CI, 0.78–0.99), the duration of vasoactive medication (mean difference –0.73 d; 95% CI, –1.16 to –0.30), and the need for renal replacement therapy (RRT) (RR 0.80; 95% CI, 0.63–1.02) (low to moderate certainty evidence), and lactate clearance (high certainty evidence). POCUS-guided resuscitation may results in little to no difference in ICU or hospital admissions, ICU and hospital length of stay, and the need for mechanical ventilation (MV) (low to moderate certainty evidence). There is an uncertain effect on the risk of acute kidney injury and the duration of MV or RRT (very low certainty evidence). CONCLUSIONS: POCUS-guided resuscitation in shock may yield important patient and health system benefits. Due to lack of sufficient evidence, we were unable to explore how the thresholds of operator competency, frequency, and timing of POCUS scans impact patient outcomes.
Structural and Functional Characterization of the Most Frequent Pathogenic PRKN Substitution p.R275W
Bustillos, Bernardo A. , Cocker, Liam T. , Coban, Matt , Weber, Caleb A., Bredenberg, Jenny M., Boneski, Paige K, Siuda, Joanna , Puschmann, Andreas , Narendra, Derek P. , Wszołek, Zbigniew K. , Ross, Owen A. , Caulfield, Thomas R. , Springer, Wolfdieter , Fiesel, Fabienne C. , Wszolek, Z.K. , Coban, Mathew A , Puschmann, Andreas , Narendra, Derek P , Caulfield, Thomas R , Springer, Wolfdieter , Fiesel, Fabienne C , Ross, Owen A , Siuda, Joanna S. , Sławek, Jarosław , Graff, Caroline , Dickson, Dennis W.

Mayo Clinic

Cells | September 13, 2024 | Volume: 13 | Issue: 18 | Pages: 1540

10.3390/cells13181540 | PMID 39329724 Get It

Mutations in the PINK1 and PRKN genes are the most frequent genetic cause of early-onset Parkinson disease. The pathogenic p.R275W substitution in PRKN is the most frequent substitution observed in patients, and thus far has been characterized mostly through overexpression models that suggest a possible gain of toxic misfunction. However, its effects under endogenous conditions are largely unknown. We used patient fibroblasts, isogenic neurons, and post-mortem human brain samples from carriers with and without PRKN p.R275W to assess functional impact. Immunoblot analysis and immunofluorescence were used to study mitophagy activation, and mitophagy execution was analyzed by flow cytometry of the reporter mitoKeima. The functional analysis was accompanied by structural investigation of PRKN p.R275W. We observed lower PRKN protein in fibroblasts with compound heterozygous p.R275W mutations. Isogenic neurons showed an allele-dose dependent decrease in PRKN protein. Lower PRKN protein levels were accompanied by diminished phosphorylated ubiquitin and decreased MFN2 modification. Mitochondrial degradation was also allele-dose dependently impaired. Consistently, PRKN protein levels were drastically reduced in human brain samples from p.R275W carriers. Finally, structural simulations showed significant changes in the closed form of PRKN p.R275W. Our data suggest that under endogenous conditions the p.R275W mutation results in a loss-of-function by destabilizing PRKN.