Citations

Clear

394 citation(s) found for "Kallmes, David F".

In vivo comparison of shape memory polymer foam‐coated and bare metal coils for aneurysm occlusion in the rabbit elastase model
Herting, Scott M. , Boyle, Anthony J., Nash, Landon D., Asnafi, Solmaz , Jakaitis, Daniel R. , Johnson, Collin R., Graul, Lance M. , Yeh, Chung, Kallmes, David F. , Kadirvel, Ramanathan , Maitland, Duncan J. , Ding, Yonghong , Dai, Daying , Yeh, Chung

Mayo Clinic

Journal of Biomedical Materials Research Part B: Applied Biomaterials | February 18, 2019 | Volume: 107 | Issue: 8 | Pages: 2466-2475

10.1002/jbm.b.34337 | PMID 30775843 Get It

AbstractShape memory polymer (SMP) foam‐coated coils (FCCs) are new embolic coils coated with porous SMP designed to expand for increased volume filling and enhanced healing after implantation. The purpose of this study was to compare chronic aneurysm healing after treatment with SMP FCCs to bare platinum coil (BPC) controls in the rabbit elastase aneurysm model. BPCs or SMP FCCs were implanted in rabbit elastase‐induced aneurysms for follow‐up at 30 days (n = 10), 90 days (n = 5), and 180 days (n = 12 for BPCs; n = 14 for SMP FCCs). Aneurysm occlusion and histologic healing, including a qualitative healing score, neointima thickness, collagen deposition, and inflammation were compared between the two groups. The mean neointima thickness was significantly greater in groups treated with SMP FCCs for all three time points. Histologic healing scores and collagen deposition quantification suggested that aneurysms treated with SMP FCCs experience more complete healing of the dome by 90 days, but the differences were not statistically significant. More progressive occlusion and recanalization were observed in aneurysms treated with SMP FCCs, but neither difference was statistically significant. Additionally, the SMP foam used in the FCCs was found to degrade faster in the rabbit elastase model than expected based on previous studies in a porcine sidewall aneurysm model. This study suggests that SMP FCCs can promote neointima formation along the aneurysm neck, and may lead to more complete healing of the dome and neck. These findings indicate potential benefits of this device for aneurysm occlusion procedures. © 2019 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B:2466–2475, 2019.
The Efficacy and Safety of Vertebral Augmentation: A Second ASBMR Task Force Report
Ebeling, Peter R. , Bauer, Douglas C. , Eastell, Richard , Fink, Howard A , Guañabens, Núria , Kado, Deborah M. , Kallmes, David F. , Katzman, Wendy B. , Rodríguez, Alexander J. , Wermers, Robert A. , Wilson, H Alexander, Bouxsein, Mary , Kallmes, David, Wermers, Robert, Ebeling, Peter R , Bauer, Douglas C , Fink, Howard A , Åkesson, Kristina , Buchbinder, Rachelle , Giangregorio, Lora

Mayo Clinic

Journal of Bone and Mineral Research | January 24, 2019 | Volume: 34 | Issue: 1 | Pages: 3-21

10.1002/jbmr.3653 | PMID 30677181 Get It

ABSTRACT Vertebral augmentation is among the current standards of care to reduce pain in patients with vertebral fractures (VF), yet a lack of consensus regarding efficacy and safety of percutaneous vertebroplasty and kyphoplasty raises questions on what basis clinicians should choose one therapy over another. Given the lack of consensus in the field, the American Society for Bone and Mineral Research (ASBMR) leadership charged this Task Force to address key questions on the efficacy and safety of vertebral augmentation and other nonpharmacological approaches for the treatment of pain after VF. This report details the findings and recommendations of this Task Force. For patients with acutely painful VF, percutaneous vertebroplasty provides no demonstrable clinically significant benefit over placebo. Results did not differ according to duration of pain. There is also insufficient evidence to support kyphoplasty over nonsurgical management, percutaneous vertebroplasty, vertebral body stenting, or KIVA®. There is limited evidence to determine the risk of incident VF or serious adverse effects (AE) related to either percutaneous vertebroplasty or kyphoplasty. No recommendation can be made about harms, but they cannot be excluded. For patients with painful VF, it is unclear whether spinal bracing improves physical function, disability, or quality of life. Exercise may improve mobility and may reduce pain and fear of falling but does not reduce falls or fractures in individuals with VF. General and intervention-specific research recommendations stress the need to reduce study bias and address methodological flaws in study design and data collection. This includes the need for larger sample sizes, inclusion of a placebo control, more data on serious AE, and more research on nonpharmacologic interventions. Routine use of vertebral augmentation is not supported by current evidence. When it is offered, patients should be fully informed about the evidence. Anti-osteoporotic medications reduce the risk of subsequent vertebral fractures by 40–70%. © 2018 American Society for Bone and Mineral Research.
Effect of Carotid Siphon Anatomy on Aneurysm Occlusion After Flow Diversion for Treatment of Internal Carotid Artery Aneurysms
Rinaldo, Lorenzo , Brinjikji, Waleed , Cloft, Harry J. , Kallmes, David F. , Rangel-Castilla, Leonardo , Rangel-Castilla, Leonardo

Mayo Clinic

Operative Neurosurgery | November 29, 2018 | Volume: 17 | Issue: 2 | Pages: 123-131

10.1093/ons/opy340 | PMID 30496571 Get It

Abstract BACKGROUND Flow diversion (FD) is effective for treatment of intracranial internal carotid artery (ICA) aneurysms. OBJECTIVE To determine whether carotid siphon (CS) geometry influences the efficacy of FD when employed for ICA aneurysms. METHODS Outcomes of a consecutive series of patients with ICA aneurysms treated with FD were retrospectively reviewed. CS anatomy was quantified through measurement of the posterior, anterior, and anterosuperior bend angles in accordance with previously described methodology. The relationship of CS geometry to likelihood of incomplete aneurysm occlusion at 1 yr after treatment was assessed with multivariate logistic regression analysis. RESULTS There were 167 ICA aneurysms in 164 patients treated with FD during the study period. The mean age of our cohort was 55.7 yr (standard deviation [SD]: 12.3) and a majority of patients were female (145/164, 86.8%). Anterior (47.4 degrees vs 8.5, P < .001) and anterosuperior bend angles (100.9 vs 76.5, P = .002) were significantly greater in aneurysms that required repeat FD after initial treatment. On multivariate logistic regression analysis, increasing patient age (unit odds ratio [OR]: 1.05, 95% confidence interval [CI] 1.01-1.08; P = .003) and anterior bend angle ≥–3.5 (OR: 2.47, 95% CI 1.04-5.86; P = .046) were associated with increased odds of incomplete aneurysm occlusion at 1 yr after treatment. CONCLUSION These findings suggest that variations in CS anatomy may influence the efficacy of FD treatment and should be analyzed prior to offering FD for treatment of ICA aneurysms. Further investigation into the hemodynamic effects of CS geometry is warranted.
Acute ischemic stroke secondary to cardiac embolus of a ‘foreign body’ material after a redo sternotomy for mitral valve replacement: A case report
Fitzgerald, Seán , Rizvi, Asim , Williamson, Eric E. , Doyle, Karen , Kallmes, David F. , Brinjikji, Waleed , Dai, Daying , Fitzgerald, Seán , Lanzino, Giuseppe

Mayo Clinic

Interventional Neuroradiology | November 14, 2018 | Volume: 25 | Issue: 2 | Pages: 208-211

10.1177/1591019918810538 | PMID 30428742 Get It

Summary Cardiac surgery has been shown to be associated with increased risk of acute ischemic stroke. This report presents a case of a successful mechanical embolectomy procedure to treat a patient for an acute ischemic stroke, which was caused by the cardiac embolization of a ‘foreign body’ containing debris following a redo sternotomy procedure for mitral valve replacement and tricuspid valve annuloplasty.
Percutaneous vertebroplasty for osteoporotic vertebral compression fracture
Johnston, Renea V , Rischin, Kobi J , Homik, Joanne , Golmohammadi, Kamran, Kallmes, David F. , Buchbinder, Rachelle , Jones, C Allyson

Mayo Clinic

Cochrane Database of Systematic Reviews | November 6, 2018 | Volume: 2018 | Issue: 11 | Pages: No page available

10.1002/14651858.cd006349.pub4 | PMID 30399208 Get It

Abstract TP82: Changes in the Distal Vessel Wall After Flow Diverter Treatment
Parameswaran, Praveen Kolumam, Ding, Yong Hong, Asnafi, Solmaz , Urban, Matthew M, Kallmes, David F. , Kadirvel, Ramanathan , Dai, Daying , Ding, Yonghong

Mayo Clinic

Stroke | October 8, 2018 | Volume: 49 | Issue: Suppl_1 | Pages: No page available

10.1161/str.49.suppl_1.tp82 Get It

Background: Flow diverters (FD) are increasingly used in the treatment of intracranial aneurysms. The risk of distal thromboembolic complications with FD is high, even in patients treated with dual antiplatelet therapy. The aim of the study was to understand the downstream vascular wall changes, by measuring the pulse wave velocity and vascular contractility following flow diverter treatment in a rabbit model. Methods: FD (Pipeline Embolic Device, Medtronic) were implanted in normal rabbits and sham-operated aorta were used as controls (n=5 for each group). Pulse wave imaging with ultra-fast ultrasound at 1600 frames per second (Vantage, Verasonics, Inc.) was performed in the vessel wall distal to FD, prior to device implantation and at 8 weeks follow up to measure the pulse wave propagation. Force contraction studies were conducted in the aortic rings using organ bath to assess the vascular functions. Results: The difference in pulse wave velocity (PWV) in the follow-up compared to pre-implantation was significantly higher (p=0.03,Fig 1A) in the distal vessels compared to sham controls (mean difference of PWV was 1.18 m/s and -0.37m/s, respectively as shown in Fig 1B). Conversely, the distal aortic segments to FD exhibited 55% increase in the level of vascular contractility compared to that of proximal segments (p=0.002). There is a significant positive correlation between mean PWV and mean vascular contractility. Conclusion: Our study found changes in the PWV after implantation of the FD, which correlated with vascular contractility. These results could explain vascular wall changes downstream following FD implantation.
Abstract TP54: Machine-Learned Characterization of Acute Ischemic Stroke Clots Reveals a Correlation Between Clot Composition and Density on CT
Wang, Shunli , Murphree, Dennis H. , Douglas, Andrew , Kadirvel, Ramanathan , Brinjikji, Waleed , Kallmes, David F. , Karen, Doyle M, Fitzgerald, Seán , Dai, Daying , Pandit, Abhay

Mayo Clinic

Stroke | October 8, 2018 | Volume: 49 | Issue: Suppl_1 | Pages: No page available

10.1161/str.49.suppl_1.tp54 Get It

Introduction: The composition of acute ischemic stroke (AIS) blood clots can impact their successful removal via endovascular therapy. Identification of the clot composition prior to endovascular treatment may influence the optimal treatment strategy. In this study, we aimed to investigate the relationship between the Hounsfield Unit intensity on CT and machine-learned characterization of clot composition. Methods: Prior to endovascular treatment, each patient had a non-contrast CT performed. Histopathological analysis of the clots was performed and clot composition was quantified via standard thresholding techniques using Adobe Photoshop. In addition, following representative cell labeling by an expert pathologist, image segmentation algorithms (Orbital Image Analysis, Actelion Ltd.) were trained on each case to quantify composition by cell type. The clots were categorized into 3 groups: red blood cell (RBC) dominant (>50%), RBC proportion equal to fibrin and fibrin dominant (>50%). Correlations between clot composition and Hounsfield Units (HU) density on CT were assessed. A positive Hyperdense Artery Sign was defined as ≥50 HU. Results: Twenty patients were included in the study. There was a significant correlation between clots quantified using Adobe Photoshop Image-Pro and Orbit image analysis ( ρ = 0.837, p < 0.001). A significant relationship was found between clot composition and the presence of a HAS sign, ( X 2 (2) = 6.496, p = 0.039). There is a significant positive correlation between percentage of RBC in the clot and the presence of a HAS sign ( ρ = 0.632, p = 0.002**). There is also a significant positive correlation between the presence of fibrin-rich and the absence of a HAS sign ( ρ = 0.600, p = 0.004**). Conclusion: Machine learning software can accurately quantify AIS clot composition. The Hounsfield unit density of an AIS clot on a non-contrast CT correlates with the composition of the clot. Measuring the HU of the clot on CT prior to endovascular intervention may inform the clinician of the clot type and help to determine the most appropriate treatment strategy for that clot.
Novel aspiration catheter design for acute stroke thrombectomy
Long, Troy D, Kallmes, David F. , Shigematsu, Tomoyoshi , Halaszyn, Alexander Michael , Wolter, Julia , Berenstein, Alejandro , Halaszyn, Alexander Michael , Hanel, Ricardó A.

Mayo Clinic

Journal of NeuroInterventional Surgery | July 30, 2018 | Volume: 11 | Issue: 2 | Pages: 190-195

10.1136/neurintsurg-2017-013702 | PMID 30061368 Get It

Background Navigable, large diameter aspiration catheters demonstrate markedly improved recanalization rates over smaller lumen devices in suction embolectomy. We evaluated the performance of a novel aspiration catheter system designed to maximize lumen size, and compare it to other commercially available aspiration catheters. Methods The 6F R4Q aspiration catheter system comprises a proximal pusher wire of 117 cm length connected to a distal catheter of 25 cm length. When placed through standard guide catheters and into the cerebral circulation, the proximal catheter makes a tight seal between its outer surface and the guide catheter’s inner surface. During aspiration, in vitro flow rates and tip suction force under gentle retraction were compared among 10 commercially available aspiration catheters and the R4Q system. Results The R4Q 6F, 5F, 4F, and 3F catheters achieved flow rates at least 21.9%, 24.7%, 61.9%, and 244.7% greater than the other catheters tested respectively and the R4Q 6F produced a 140.2% higher tip force than a catheter of similar size. Fluid flow rate in the R4Q 6F increased on retraction into the guide catheter, delivering a 58.2% increase from fully extended to fully retracted. Conclusion The R4Q design demonstrates a substantial increase in aspirated flow rate and suction force due to an increased effective diameter than standard tubular catheter designs tested. The prominent increase in the aspiration parameters measured in vitro supports the potential for improved clinical results during stroke thrombectomy procedures.
Aspiring to an improved aspiration literature
Kallmes, David F. , Ansari, Sameer A. , Liebeskind, David S. , Zaidat, Osama O. , Ansari, Sameer A , Liebeskind, David S. , Siddiqui, Adnan H.

Mayo Clinic

Journal of NeuroInterventional Surgery | June 6, 2018 | Volume: 10 | Issue: 10 | Pages: 923-924

10.1136/neurintsurg-2018-014046 | PMID 29875275 Get It

Optimal anesthetic strategy for endovascular stroke therapy
Kallmes, David F. , Rabinstein, Alejandro A.

Mayo Clinic

Neurology | June 5, 2018 | Volume: 91 | Issue: 1 | Pages: 16-18

10.1212/wnl.0000000000005754 | PMID 29858470 Get It