Citations

Clear

3059 citation(s) found for "Johnson, A".

Peripheral (deep) but not periventricular MRI white matter hyperintensities are increased in clinical vascular dementia compared to Alzheimer's disease
Smith, Charles D. , Johnson, Eleanor S. , Jicha, Gregory A. , Schmitt, Frederick A. , Nelson, Peter T. , Kryscio, Richard J. , Murphy, Ronan, Wellnitz, Clinton V., Eldik, Linda J. Van , Jicha, Gregory A

Mayo Clinic

Brain and Behavior | February 16, 2016 | Volume: 6 | Issue: 3 | Pages: No page available

10.1002/brb3.438 | PMID 26925303 Get It

AbstractBackground and purposeVascular dementia (VAD) is a complex diagnosis at times difficult to distinguish from Alzheimer's disease (AD). MRI scans often show white matter hyperintensities (WMH) in both conditions. WMH increase with age, and both VAD and AD are associated with aging, thus presenting an attribution conundrum. In this study, we sought to show whether the amount of WMH in deep white matter (dWMH), versus periventricular white matter (PVH), would aid in the distinction between VAD and AD, independent of age.MethodsBlinded semiquantitative ratings of WMH validated by objective quantitation of WMH volume from standardized MRI image acquisitions. PVH and dWMH were rated separately and independently by two different examiners using the Scheltens scale. Receiver operator characteristic (ROC) curves were generated using logistic regression to assess classification of VAD (13 patients) versus AD (129 patients). Clinical diagnoses were made in a specialty memory disorders clinic.ResultsUsing PVH rating alone, overall classification (area under the ROC curve, AUC) was 75%, due only to the difference in age between VAD and AD patients in our study and not PVH. In contrast, dWMH rating produced 86% classification accuracy with no independent contribution from age. A global Longstreth rating that combines dWMH and PVH gave an 88% AUC.ConclusionsIncreased dWMH indicate a higher likelihood of VAD versus AD. Assessment of dWMH on MRI scans using Scheltens and Longstreth scales may aid the clinician in distinguishing the two conditions.
Optimizing Thawed Plasma Inventories
Kuker, Kasey N., Badjie, Karafa S., Johnson, Pamela M. , Bundy, Kevin L., Buskirk, Camille M. van , Stubbs, R. James , Bundy, Kevin L.

Mayo Clinic

American Journal of Clinical Pathology | February 16, 2016 | Volume: 138 | Issue: suppl_1 | Pages: A255-A255

10.1093/ajcp/138.suppl1.237 Get It

Surgical Treatment of Pediatric Upper Limb Spasticity: The Shoulder
Seruya, Mitchel, Johnson, Joshua D. , Johnson, Joshua K.

Mayo Clinic

Seminars in Plastic Surgery | February 10, 2016 | Volume: 30 | Issue: 01 | Pages: 045-050

10.1055/s-0035-1571253 | PMID 26869863 Get It

Novel Percutaneous Epicardial Autonomic Modulation in the Canine for Atrial Fibrillation: Results of an Efficacy and Safety Study
Madhavan, Malini , Venkatachalam, K, Swale, M., Gard, Joseph J., Johnson, Susan B., Suddendorf, Scott H., Mikell, Susan B. , Ladewig, Dorothy J., NOSBUSH, TONI GRABINGER, Danielsen, Andrew J., Knudson, Mark B., Asirvatham, Samuel J. , Knudson, Mark, DeSimone, Christopher V. , Asirvatham, Samuel J

Mayo Clinic

Pacing and Clinical Electrophysiology | February 8, 2016 | Volume: 39 | Issue: 5 | Pages: 407-417

10.1111/pace.12824 | PMID 26854009 Get It

BackgroundEndocardial ablation of atrial ganglionated plexi (GP) has been described for treatment of atrial fibrillation (AF). Our objective in this study was to develop percutaneous epicardial GP ablation in a canine model using novel energy sources and catheters.MethodsPhase 1: The efficacy of several modalities to ablate the GP was tested in an open chest canine model (n = 10). Phase 2: Percutaneous epicardial ablation of GP was done in six dogs using the most efficacious modality identified in phase 1 using two novel catheters.ResultsPhase 1: Direct current (DC) in varying doses (blocking [7–12 μA], electroporation [300–500 μA], ablation [3,000–7,500 μA]), radiofrequency ablation (25–50 W), ultrasound (1.5 MHz), and alcohol (2–5 mL) injection were successful at 0/8, 4/12, 5/7, 3/8, 1/5, and 5/7 GP sites. DC (500–5,000 μA) along with alcohol irrigation was tested in phase 2. Phase 2: Percutaneous epicardial ablation of the right atrium, oblique sinus, vein of Marshall, and transverse sinus GP was successful in 5/6 dogs. One dog died of ventricular fibrillation during DC ablation at 5,000 μA. Programmed stimulation induced AF in six dogs, preablation and no atrial arrhythmia in three, flutter in one, and AF in one postablation. Heart rate, blood pressure, effective atrial refractory period, and local atrial electrogram amplitude did not change significantly postablation. Microscopic examination showed elimination of GP, and minimal injury to atrial myocardium.ConclusionPercutaneous epicardial ablation of GP using DC and novel catheters is safe and feasible and may be used as an adjunct to pulmonary vein isolation in the treatment of AF in order to minimize additional atrial myocardial ablation.
Author response: Targeting senescent cells enhances adipogenesis and metabolic function in old age
Ding, Husheng, Weivoda, Megan , Pirtskhalava, Tamar , White, Thomas A. , Sepe, Anna, Johnson, Kurt O. , Giorgadze, Nino, Jensen, Michael D. , Kirkland, James L. , Xu, Ming , Palmer, Allyson K. , Stout, Michael B , LeBrasseur, Nathan K. , Tchkonia, Tamar

Mayo Clinic

No container title available | February 4, 2016 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.7554/elife.12997.028 Get It

Safety and Feasibility of Laparoscopic Abdominal Surgery in Patients With Mechanical Circulatory Assist Devices
Chapital, Alyssa B. , Johnson, Daniel J. , Staley, Linda L., Arabía, Francisco A. , Harold, Kristi L., Ashfaq, Awais , Ashfaq, Awais

Mayo Clinic

Surgical Innovation | February 2, 2016 | Volume: 23 | Issue: 5 | Pages: 469-473

10.1177/1553350616628679 | PMID 26839214 Get It

Objectives. Increasing number of mechanical circulatory assist devices (MCADs) are being placed in heart failure patients. Morbidity from device placement is high and the outcome of patients who require noncardiac surgery after, is unclear. As laparoscopic interventions are associated with decreased morbidity, we examined the impact of such procedures in these patients. Methods. A retrospective review was conducted on 302 patients who underwent MCAD placement from 2005 to 2012. All laparoscopic abdominal surgeries were included and impact on postoperative morbidity and mortality studied. Results. Ten out of 16 procedures were laparoscopic with 1 conversion to open. Seven patients had a HeartMate II, 2 had Total Artificial Hearts, and 1 had CentriMag. Four patients had devices for ischemic cardiomyopathy and 6 cases were emergent. Surgeries included 6 laparoscopic cholecystectomies, 2 exploratory laparoscopies, 1 laparoscopic colostomy takedown, and 1 laparoscopic ventral hernia repair with mesh. Median age of the patients was 63 years (range, 29-79 years). Median operative time was 123 minutes (range, 30-380 minutes). Five of 10 patients were on preoperative anticoagulation with average intraoperative blood loss of 150 mL (range, 20-700 mL). There were 3 postoperative complications; acute respiratory failure, acute kidney injury and multisystem organ failure resulting in death not related to the surgical procedure. Conclusion. The need for noncardiac surgery in post-MCAD patients is increasing due to limited donors and due to more durable and longer support from newer generation assist devices. While surgery should be approached with caution in this high-risk group, laparoscopic surgery appears to be a safe and successful treatment option.
Proposal for a Standard Format for Neurophysiology Data Recording and Exchange
Stead, Matt, Halford, Jonathan J. , Halford, Jonathan J

Mayo Clinic

Journal of Clinical Neurophysiology | January 24, 2016 | Volume: 33 | Issue: 5 | Pages: 403-413

10.1097/wnp.0000000000000257 | PMID 26808620 Get It

Summary: The lack of interoperability between information networks is a significant source of cost in health care. Standardized data formats decrease health care cost, improve quality of care, and facilitate biomedical research. There is no common standard digital format for storing clinical neurophysiologic data. This review proposes a new standard file format for neurophysiology data (the bulk of which is video-electroencephalographic data), entitled the Multiscale Electrophysiology Format, version 3 (MEF3), which is designed to address many of the shortcomings of existing formats. MEF3 provides functionality that addresses many of the limitations of current formats. The proposed improvements include (1) hierarchical file structure with improved organization; (2) greater extensibility for big data applications requiring a large number of channels, signal types, and parallel processing; (3) efficient and flexible lossy or lossless data compression; (4) industry standard multilayered data encryption and time obfuscation that permits sharing of human data without the need for deidentification procedures; (5) resistance to file corruption; (6) facilitation of online and offline review and analysis; and (7) provision of full open source documentation. At this time, there is no other neurophysiology format that supports all of these features. MEF3 is currently gaining industry and academic community support. The authors propose the use of the MEF3 as a standard format for neurophysiology recording and data exchange. Collaboration between industry, professional organizations, research communities, and independent standards organizations is needed to move the project forward.
Case-Based Review: meningioma
Fogh, Shannon , Barker, Fred G., Brastianos, Priscilla K. , Clarke, Jennifer , Oberndorfer, Stephan, Preusser, Matthias , Raghunathan, Aditya , Santagata, Sandro , Theodosopoulos, Philip V. , Fogh, Shannon E, Clarke, Jennifer L, Johnson, Derek R. , Kaufmann, Timothy J. , Santagata, Sandro , Raghunathan, Aditya , Preusser, Matthias , Brastianos, Priscilla K.

Mayo Clinic

Neuro-Oncology Practice | January 15, 2016 | Volume: 3 | Issue: 2 | Pages: 120-134

10.1093/nop/npv063 | PMID 31386096 Get It

AbstractMeningioma is by far the most common primary intracranial tumor in adults. Treatment of meningioma is complex due to a tremendous amount of variability in tumor behavior. Many patients are incidentally found to have tumors that will remain asymptomatic throughout their lives. It is important to identify these patients so that they can be spared from potentially morbid interventions. On the other end of the spectrum, high-grade meningiomas can behave very aggressively. When treatment is necessary, surgical resection is the cornerstone of meningioma therapy. Studies spanning decades have demonstrated that extent of resection correlates with prognosis. Radiation therapy, either in the form of external beam radiation therapy or stereotactic radiosurgery, represents another important therapeutic tool that can be used in place of or as a supplement to surgery. There are no chemotherapeutic agents of proven efficacy against meningioma, and chemotherapy treatment is generally reserved for patients who have exhausted surgical and radiotherapy options. Ongoing and future studies will help to answer unresolved questions such as the optimum use of radiation in resected WHO grade II meningiomas and the efficacy of additional chemotherapy agents.
Effect of Left Atrial Ablation Process and Strategy on Microemboli Formation During Irrigated Radiofrequency Catheter Ablation in an In Vivo Model
Takami, Mitsuru , Parker, Kay D., Welker, Kirk M. , Johnson, Susan B., Packer, Douglas L. , Lehmann, H. Immo

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | January 14, 2016 | Volume: 9 | Issue: 1 | Pages: No page available

10.1161/circep.115.003226 | PMID 26763224 Get It

Background— Formation of microemboli during catheter ablation has been suggested as a cause for asymptomatic cerebral emboli. However, it is unknown which part of the process and ablation setting/strategy is most strongly related to this occurrence. Methods and Results— A total of 27 pigs were used. Catheter/sheath manipulations in left atrium were performed in 25 of 27 pigs outfitted with microemboli monitoring systems. Ablations using open-irrigated radiofrequency catheters were performed in 18 of 25 pigs. Two of 27 pigs did not undergo left atrial procedures and were injected with microembolic materials in the carotid artery to serve as positive controls. In total, 334 sheath/catheter manipulations (transseptal puncture, sheath flushing, catheter insertion, pulmonary vein venography, and sheath exchange) and 333 radiofrequency applications (power setting, 30/50 W; point-by-point/drag ablations) were analyzed. High microbubble volume in the extracorporeal circulation loop and a high number of microembolic signals in carotid artery were observed during sheath/catheter manipulations especially in saline/contrast injections at fast speed and ablations with steam pop. Fast sheath flushing produced significantly higher microbubble volume than slow sheath flushing (median, 12 200 versus 121 nL; P <0.0001). A total of 44 of 126 (35%) blood filters in the circulation loop showed microparticles (thrombus/coagulum and tissue). Most of them were seen after radiofrequency application especially in 50-W ablations, drag ablations, and steam pop. Brain magnetic resonance imaging showed positive-embolic lesions in control pigs. Conclusions— Formation of microbubbles was the greatest during fast saline/contrast injections and steam pops, whereas high-power radiofrequency applications, drag ablations, and steam pops produced most of the microparticles.
PTU-061 Utility of endoscopic retrograde cholangiography to diagnose IgG4-associated cholangitis: an international, double blind, randomised, multicentre study
Johnson, Gavin , Levy, Michael J. , Kamisawa, Terumi , Baron, Todd H. , Topazian, Mark , Okazaki, Kazuichi , Egawa, Naoto, Sheikh, Kashif, Amin, Z. , Shimosegawa, Tooru , Sandanayake, N S, Church, Nicholas , Chapman, Michael H. , Hatfield, A R, Pereira, Stephen P. , Webster, George, Kalaitzakis, Emmanouil , Levy, Michael J. , Takahashi, Naoki , Kanno, Atsushi , Uchida, Kazushige , Sandanayake, Neomal S., Chari, Suresh T.

Mayo Clinic

Liver I posters | January 7, 2016 | Volume: No volume available | Issue: No issue available | Pages: A73.2-A73

10.1136/gut.2009.209056u Get It