Citations

Clear

367 citation(s) found for "Friedman, Paul A".

Left sinus of Valsalva—Electroanatomic basis and outcomes with ablation for outflow tract arrhythmias
Mehra, Nandini, Deshmukh, Abhishek , Friedman, Paul A. , Asirvatham, Samuel J. , Kapa, Suraj , Deshmukh, Abhishek J , Friedman, Paul A , Asirvatham, Samuel J , Kapa, Suraj , Mehra, Nandini

Mayo Clinic

Journal of Cardiovascular Electrophysiology | February 12, 2020 | Volume: 31 | Issue: 4 | Pages: 952-959

10.1111/jce.14388 | PMID 32048387 Get It

AbstractIntroductionThe ablation of outflow tract premature ventricular contractions (PVCs) is generally safe and effective. In some patients, successful ablation sites may not correlate with the earliest activation. We sought to evaluate mechanistic and anatomic relevance of the region below the left sinus of Valsalva in variable morphology outflow tract ventricular arrhythmias.MethodsPVC cases where ablation was in the region inferior to the left sinus of Valsalva were identified. Procedural and demographic information and long‐term outcomes were obtained. Cadaver dissections to evaluate regional anatomy were done as well.ResultsA total of 51 cases were included (age 53 ± 10; 37 [73%] males). Ablation was done for high PVC burden (>20%; mean 27% ± 8%) and presence of symptoms (73%) or ejection fraction less than 50% (78%). QRS morphology included either R wave (8; 16%), Rs (9; 18%), or rS (67%) in lead I, no precordial transition (40; 78%), V2 transition, (7; 14%), or V3 transition (4; 8%). In 31 (61%), the site just below the left coronary cusp was the earliest site, while the remainder had another site earlier. Ablation was acutely successful in 50 of 51 (98%). After 3 months, success was noted in 48 of 51 (94%). In two patients, repeat ablation in the same region resulted in durable suppression.ConclusionThe cases presented emphasize the importance of a region centered below the left sinus of Valsalva, where multivariable morphology QRS may be successfully ablated. Consideration of mapping and ablation even when signals are late in this region may be warranted in previously failed ablation attempts or first‐line evaluation.
Utility of 30-Day Continuous Ambulatory Monitoring to Identify Patients With Delayed Occurrence of Atrioventricular Block After Transcatheter Aortic Valve Replacement
Tian, Ying , Padmanabhan, Deepak , Xiao, Peilin, Sandhu, Gurpreet S. , Greason, Kevin L. , Gulati, Rajiv , Rihal, Charanjit S. , Polk, Lynn, Sanvick, Carrie, Liu, Xing-Peng , Friedman, Paul A. , Cha, Yong‐Mei , Polk, Lynn E, McLeod, Christopher J. , Zhang, Pei , Nkomo, Vuyisile T. , Rihal, Charanjit S. , Sanvick, Carrie

Mayo Clinic

Circulation: Cardiovascular Interventions | December 13, 2019 | Volume: 12 | Issue: 12 | Pages: No page available

10.1161/circinterventions.118.007635 | PMID 31833417 Get It

Background: Mechanical injury in the conduction system requiring permanent pacemaker (PPM) associated with transcatheter aortic valve replacement (TAVR) procedure is a common complication. The objective of this study was to use ambulatory monitor BodyGuardian to assess late occurrence of atrioventricular block (AVB) after TAVR. Methods: This prospective study evaluated 365 patients who underwent TAVR at Mayo Clinic, Rochester, Minnesota between June 2016 and August 2017. Patients who received PPM for bradycardia after TAVR before discharge were considered as the PPM group. Those not requiring PPM received a BodyGuardian system (BodyGuardian group) for 30 days of continuous monitoring. Primary end point was Mobitz II or third-degree atrioventricular block (II/III AVB) at 30-day follow-up. Results: Of 365 patients, 74 who had a PPM or an implantable cardioverter-defibrillator before TAVR and 94 who were enrolled in other studies were excluded. Of 197 patients enrolled in the study, 70 (35.5%) received PPM and 127 had BodyGuardian before the hospital dismissal. Eleven of 127 (8.6%) BodyGuardian group required PPM within 30 days after TAVR for late occurrence of symptomatic bradycardia. In total, 33 of 197 (16.7%) patients developed II/III AVB (24 before and 9 after discharge). Thirty-four patients had preexisting right bundle branch block. Of them, 16 (47%) developed II/III AVB. Of 53 patients who developed new left bundle branch block after TAVR, 14% progressed to II/III AVB within 30 days. Conclusions: In patients without a standard post-TAVR pacing indication, yet a potential risk to develop AVB, a strategy of 30-day monitoring identifies additional patients who require permanent pacing.
Injectable Flexible Subcutaneous Electrode Array Technology for Electrocardiogram Monitoring Device
Bong, Jihye , Yasin, Omar , Vaidya, Vaibhav R. , Park, Jeongpil , Padmanabhan, Deepak , Cho, Sang June , Asirvatham, Roshini, Schneider, Noah, Lee, Juhwan , Kim, Eun‐Mee , Friedman, Paul A. , Cho, Sang June , Lee, Juhwan , Ma, Zhenqiang , Attia, Zachi I.

Mayo Clinic

ACS Biomaterials Science & Engineering | October 26, 2019 | Volume: 6 | Issue: 5 | Pages: 2652-2658

10.1021/acsbiomaterials.9b01102 | PMID 33463304 Get It

P2851Transvenous lead placement in the setting of venous obstruction: outcomes of tunneling technique versus venoplasty
Yasin, Omar , Padmanabhan, Deepak , Hodge, David O. , Cochuyt, Jordan J., Mulpuru, Siva K. , Cha, Y, Friedman, Paul A. , Kella, Danesh , Isath, Ameesh

Mayo Clinic

European Heart Journal | October 21, 2019 | Volume: 40 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehz748.1160 Get It

Abstract Background Venous stenosis is a well-recognized complication of transvenous leads when patients require lead revisions or device upgrade. In these cases, balloon venoplasty or alternative venous access with subcutaneous tunneling can be performed. Purpose Compare the outcomes of venoplasty vs. tunneling in patients requiring additional transvenous lead implantation. Methods A single center retrospective cohort study of all patients undergoing lead implantation/revision requiring venoplasty or tunneling from 2005–2017. Chi-squared and Wilcoxon Rank-Sum tests were used to compare categorical and continuous variables. Results Ninety five patients met our inclusion criteria (60 venoplasty & 35 tunneling). There was no difference in procedure success rates (p-value=0.98). Tunneling was associated with less fluoroscopy time but higher incidence of acute complications (0% vs. 23%, p-value=0.002) most requiring invasive intervention and/or blood product transfusion. Long term outcomes were comparable and related to lead failure or infection. Outcomes for tunneling vs. venoplasty Variable Tunneling (n=35) Venoplasty (n=60) p-value Age Y 67 (23–84) 70 (29–91) 0.25 Male (%) 24 (69%) 41 (68%) 0.98 Number of existing leads 2.1 (1–4) 2.4 (0–4) 0.1 Age of oldest lead 7.0 (0–21) 7.2 (0–33) 0.73 Number of new leads 1.2 (1–3) 1.4 (1–3) 0.26 Fluoroscopy time (SD) min 29.2 (21.3) 39.7 (21.5) 0.012 Procedure success (%) 35 (100%) 55 (92%) 0.9 Acute complications (%) 8 (23%)1 0 (0%) 0.0002 Pocket hematoma/bleed 4 (11%)2 Hemothorax 2 (6%)3 Pericarditis 1 (3%) Lead compromise 1 (3%) Follow up M 18 (0–76) 28 (0–98) N/A Long term lead issues (%) 6 (17%) 10 (17%) 0.95 Long term complication requiring intervention 4 (11%) 8 (13%) N/A Procedure success: functional lead placed as a result of venoplasty or tunneling. 1Two patients required blood products. 2Two patients required invasive intervention. 3One patient required chest tube and the other ICU admission. Conclusions Balloon venoplasty is associated with similar rates of success and a less incidence of acute complications when compared subcutaneous tunneling. Acknowledgement/Funding NIH T32 Training Grant HL07111-40
P4126Safety of magnetic resonance imaging in patients with non-conditional cardiac implantable electronic devices: A systematic review and meta-analysis
Padmanabhan, Deepak , Izath, A, Al‐Masry, Anas Abudan , Gamero, Sonia Fortin, Barout, Ahmad, Assaf, Yazan , Shetty, Devi Prasad , Asirvatham, S, Felmlee, Joel P. , Watson, Robert E. , Cha, Y, Friedman, Paul A. , Farwati, Medhat , Al-Masry, A, Kella, Danesh

Mayo Clinic

European Heart Journal | October 21, 2019 | Volume: 40 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehz745.0698 Get It

Abstract Recent guideline statements approve the performance of magnetic resonance imaging (MRI) in patients with non-conditional cardiac implantable electronic devices (CIEDs) under certain closely monitored conditions. Data from current registries may have lower power to discern changes that may occur in the CIED after the MRI. Objective We aimed to systematically review the literature to identify the adverse events and significance of changes in device function associated with performing MRI in patients with CIEDs Methods A comprehensive literature search of the databases was performed between 1980- 2017. Two independent reviewers selected studies and extracted data. A random-effects model was used for meta-analysis. Results A total of 7,422 patients underwent 8,865 MRI studies. No death occurred post MRI. Clinical adverse events were extremely rare (mostly less than 1%) and are summarized in Table 1. No significant changes in the pooled mean effect size estimate was noted for the changes in the lead parameters (pacing threshold, sensing and impedance) Binary outcomes post magnetic resonance imaging in patients with non-conditional cardiac implantable electronic devices Outcome Sample size Number of patients Rate SE LL of CI UL of CI Death 7401 0 0 0 0 0 Atrial arrhythmia 7173 10 0.001 0.0004 0.0007 0.0024 Ventricular arrhythmia 7371 9 0.0012 0.0004 0.0006 0.0022 Oversensing 4981 17 0.0034 0.0008 0.0020 0.0053 Inhibition of pacing 7371 6 0.0008 0.0003 0.0003 0.0016 Lead Failure/Generator Failure 7475/7475 2/8 0.0002/0.0011 0.0001/0.0004 0.0001/0.0005 0.0009/0.002 Power on Reset 1388 105 0.0131 0.0014 0.0107 0.0161 Did not complete scan 6851 13 0.0019 0.0005 0.0011 0.0031 Chest pain 7080 11 0.0021 0.0004 0.0008 0.0027. Lead threshold rise (>0.5v/>50%-A/V) 5076/6246 12/16 0.0024/0.0026 0.0007/0.0006 0.0013/0.0015 0.0040/0.0041 Change in Battery voltage >0.04V 7132 42 0.0061 0.0009 0.0043 0.0079 Sensing decrease >50%-A/V 5087/5834 17/9 0.0033/0.0015 0.0008/0.0005 0.0020/0.0008 0.0052/0.0028 Impedance changes >50ohms/>50% 5810 22 0.0038 0.0008 0.0024 0.0057 Rise in cardiac enzymes 1703 26 0.0152 0.0030 0.0102 0.0219 A, atrial; V, ventricular; SE, standard Error; LL, lower limit; UL, upper limit; CI, Confidence intervals. Conclusions MRI in patients with non-conditional CIEDs can be performed with high degree of safety and low rate of clinical events when performed under standardized protocols Acknowledgement/Funding None
Stellate ganglion block and cardiac sympathetic denervation in patients with inappropriate sinus tachycardia
Cha, Yong‐Mei , Li, Xuping , Yang, Mei , Han, Jie , Wu, Gang , Noseworthy, Peter A. , Mulpuru, Siva K. , Asirvatham, Samuel J. , Brady, Peter A. , Rho, Richard H., Friedman, Paul A. , Lee, Hon‐Chi, Tian, Ying , Zhou, Shenghua , Munger, Thomas M. , Ackerman, Michael J. , Shen, Win‐Kuang , Kapa, Suraj , Noseworthy, Peter A , Mulpuru, Siva K , Asirvatham, Samuel J , Friedman, Paul A , Zhou, Shenghua , Kapa, Suraj , McLeod, Christopher J. , Zhou, Shenghua

Mayo Clinic

Journal of Cardiovascular Electrophysiology | October 18, 2019 | Volume: 30 | Issue: 12 | Pages: 2920-2928

10.1111/jce.14233 | PMID 31625219 Get It

AbstractBackgroundInappropriate sinus tachycardia (IST) remains a clinical challenge because patients often are highly symptomatic and not responsive to medical therapy.ObjectiveTo study the safety and efficacy of stellate ganglion (SG) block and cardiac sympathetic denervation (CSD) in patients with IST.MethodsTwelve consecutive patients who had drug‐refractory IST (10 women) were studied. According to a prospectively initiated protocol, five patients underwent an electrophysiologic study before and after SG block (electrophysiology study group). The subsequent seven patients had ambulatory Holter monitoring before and after SG block (ambulatory group). All patients underwent SG block on the right side first, and then on the left side. Selected patients who had heart rate reduction ≥15 beats per minute (bpm) were recommended to consider CSD.ResultsThe mean (SD) baseline heart rate (HR) was 106 (21) bpm. The HR significantly decreased to 93 (20) bpm (P = .02) at 10 minutes after right SG block and remained significantly slower at 97(19) bpm at 60 minutes. Left SG block reduced HR from 99 (21) to 87(16) bpm (P = .02) at 60 minutes. SG block had no significant effect on blood pressure or HR response to isoproterenol or exercise (all P > .05). Five patients underwent right (n = 4) or bilateral (n = 1) CSD. The clinical outcomes were heterogeneous: one patient had complete and two had partial symptomatic relief, and two did not have improvement.ConclusionSG blockade modestly reduces resting HR but has no significant effect on HR during exercise. Permanent CSD may have a modest role in alleviating symptoms in selected patients with IST.
Sudden cardiac arrest and ventricular arrhythmias following first type I myocardial infarction in the contemporary era
Amin, Mustapha, Kella, Danesh , Killu, Ammar M. , Padmanabhan, Deepak , Hodge, David O. , Golafshar, Michael A. , Chamberlain, Alanna M. , Lee, Justin Z. , Shen, Win‐Kuang , Friedman, Paul A. , Asirvatham, Samuel J. , Roger, Véronique L. , Mulpuru, Siva K. , Mulpuru, Siva K , Asirvatham, Samuel J , Kella, Danesh K , Chamberlain, Alanna M , Golafshar, Michael , Gersh, Bernard J.

Mayo Clinic

Journal of Cardiovascular Electrophysiology | October 7, 2019 | Volume: 30 | Issue: 12 | Pages: 2869-2876

10.1111/jce.14218 | PMID 31588605 Get It

AbstractIntroductionMyocardial infarction (MI) is associated with an increase in subsequent heart failure (HF), recurrent ischemic events, sudden cardiac arrest, and ventricular arrhythmias (SCA‐VA). The primary objective of the study to determine the role of intercurrent HF and ischemic events on the development of SCA‐VA following first type I MI.Methods and resultsA retrospective cohort study of patients experiencing first type 1 MI in Olmsted County, Minnesota (2002‐2012) was conducted by identifying patients using the medical records linkage system (Rochester epidemiology project). Patients aged ≥18 years were followed from the time of MI till death or 31 July, 2017. Intercurrent HF and ischemic events were the primary exposures following MI and their association with outcome SCA‐VA was assessed. Eight hundred and sixty‐seven patients (mean age was 63 ± 14.5 years; 69% male; 49.8% ST‐elevation myocardial infarction) who had their first type I MI during the study period were included. Majority of acute MI patients were revascularized using percutaneous coronary intervention and bypass surgery (628 [72.43%] and 87 [10.03%] respectively). During a mean follow‐up of 7.69 ± 4.17 years, HF, recurrent ischemic events and SCA‐VA occurred in 155 (17.9%), 245 (28.3%), and 40 (4.61%) patients respectively. Low ejection fraction (adjusted hazard ratio [HR] 0.95; 95% confidence interval [CI], 0.93‐0.98; P < .001), intercurrent HF (adjusted HR 3.11; 95% CI, 1.39‐6.95; P = .006) and recurrent ischemic events (adjusted HR 3.47; 95% CI, 1.68‐7.18; P < .001) were associated with subsequent SCA‐VA.ConclusionSCA‐VA occurred in a small proportion of patients after MI and is associated with intercurrent HF and recurrent ischemic events.
Effective Use of Percutaneous Stellate Ganglion Blockade in Patients With Electrical Storm
Tian, Ying , Wittwer, Erica D. , Xiao, Peilin , Mulpuru, Siva K. , Deshmukh, Abhishek , Lee, Hon-Chi, Ackerman, Michael J. , Asirvatham, Samuel J. , Munger, Thomas M. , Liu, Xing-Peng , Friedman, Paul A. , Cha, Yong‐Mei , Asirvatham, Samuel J , Kapa, Suraj , McLeod, Christopher J. , Noseworthy, Peter A.

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | September 13, 2019 | Volume: 12 | Issue: 9 | Pages: No page available

10.1161/circep.118.007118 | PMID 31514529 Get It

Background: Percutaneous stellate ganglion blockade (SGB) has been used for drug-refractory electrical storm due to ventricular arrhythmia (VA); however, the effects and long-term outcomes have not been well studied. Methods: This study included 30 consecutive patients who had drug-refractory electrical storm and underwent percutaneous SGB between October 1, 2013, and March 31, 2018. Bupivacaine, alone or combined with lidocaine, was injected into the neck with good local anesthetic spread in the vicinity of the left stellate ganglion (n=15) or both stellate ganglia (n=15). Data were collected for patient clinical characteristics, immediate and long-term outcomes, and procedure-related complications. Results: Clinical characteristics included age, 58±14 years; men, 73.3%; and left ventricular ejection fraction, 34±16%. At 24 hours, 60% of patients were free of VA. Patients whose VA was controlled had a lower hospital mortality rate than patients whose VA continued (5.6% versus 50.0%; P =0.009). Implantable cardioverter-defibrillator interrogation showed a significant 92% reduction in VA episodes from 26±41 to 2±4 in the 72 hours after SGB ( P <0.001). Patients who died during the same hospitalization (n=7) were more likely to have ischemic cardiomyopathy (100% versus 43.5%; P =0.03) and recurrent VA within 24 hours (85.7% versus 26.1%; P =0.009). There were no procedure-related major complications. Conclusions: SGB effectively attenuated electrical storm in more than half of patients without procedure-related complications. Percutaneous SGB may be considered for stabilizing ventricular rhythm in patients for whom other therapies have failed.
Age and Sex Estimation Using Artificial Intelligence From Standard 12-Lead ECGs
Friedman, Paul A. , Ladewig, Dorothy J., Satam, Gaurav, Pellikka, Patricia A. , Munger, Thomas M. , Asirvatham, Samuel J. , Carter, Rickey E. , Asirvatham, Samuel J , Pellikka, Patricia A , Carter, Rickey E , Attia, Zachi I. , Noseworthy, Peter A. , López-Jiménez, Francisco , Scott, Christopher G. , Kapa, Suraj

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | August 27, 2019 | Volume: 12 | Issue: 9 | Pages: No page available

10.1161/circep.119.007284 | PMID 31450977 Get It

Background: Sex and age have long been known to affect the ECG. Several biologic variables and anatomic factors may contribute to sex and age-related differences on the ECG. We hypothesized that a convolutional neural network (CNN) could be trained through a process called deep learning to predict a person’s age and self-reported sex using only 12-lead ECG signals. We further hypothesized that discrepancies between CNN-predicted age and chronological age may serve as a physiological measure of health. Methods: We trained CNNs using 10-second samples of 12-lead ECG signals from 499 727 patients to predict sex and age. The networks were tested on a separate cohort of 275 056 patients. Subsequently, 100 randomly selected patients with multiple ECGs over the course of decades were identified to assess within-individual accuracy of CNN age estimation. Results: Of 275 056 patients tested, 52% were males and mean age was 58.6±16.2 years. For sex classification, the model obtained 90.4% classification accuracy with an area under the curve of 0.97 in the independent test data. Age was estimated as a continuous variable with an average error of 6.9±5.6 years (R-squared =0.7). Among 100 patients with multiple ECGs over the course of at least 2 decades of life, most patients (51%) had an average error between real age and CNN-predicted age of <7 years. Major factors seen among patients with a CNN-predicted age that exceeded chronologic age by >7 years included: low ejection fraction, hypertension, and coronary disease ( P <0.01). In the 27% of patients where correlation was >0.8 between CNN-predicted and chronologic age, no incident events occurred over follow-up (33±12 years). Conclusions: Applying artificial intelligence to the ECG allows prediction of patient sex and estimation of age. The ability of an artificial intelligence algorithm to determine physiological age, with further validation, may serve as a measure of overall health.
Association between the Charlson comorbidity index and outcomes after implantable cardioverter defibrillator generator replacement
Amin, Mustapha M., Witt, Chance M. , Waks, Jonathan W. , Mehta, Ramila A. , Friedman, Paul A. , Kramer, Daniel B. , Buxton, Alfred E. , Mulpuru, Siva K. , Hodge, David O. , Frey, Rebecca J., Frederick, Nicolette K., Cha, Yong‐Mei , Brenes-Salazar, Jorge A., Madhavan, Malini , Brenes-Salazar, Jorge

Mayo Clinic

Pacing and Clinical Electrophysiology | July 29, 2019 | Volume: 42 | Issue: 9 | Pages: 1236-1242

10.1111/pace.13762 | PMID 31355952 Get It

AbstractBackgroundRecipients of implantable cardioverter defibrillator (ICD) generator replacement with multiple medical comorbidities may be at higher risk of adverse outcomes that attenuate the benefit of ICD replacement. The aim of this investigation was to study the association between the Charlson comorbidity index (CCI) and outcomes after ICD generator replacement.MethodsAll patients undergoing first ICD generator replacement at Mayo Clinic, Rochester and Beth Israel Deaconess Medical Center, Boston between 2001 and 2011 were identified. Outcomes included: (a) all‐cause mortality, (b) appropriate ICD therapy, and (c) death prior to appropriate therapy. Multivariable Cox regression analysis was performed to assess association between CCI and outcomes.ResultsWe identified 1421 patients with mean age of 69.6 ± 12.1 years, 81% male and median (range) CCI of 3 (0‐18). During a mean follow‐up of 3.9 ± 3 years, 52% of patients died, 30.6% experienced an appropriate therapy, and 23.6% died without experiencing an appropriate therapy. In multivariable analysis, higher CCI score was associated with increased all‐cause mortality (Hazard ratio, HR 1.10 [1.06‐1.13] per 1 point increase in CCI, P < .001), death without prior appropriate therapy (HR 1.11 [1.07‐1.15], P < .0001), but not associated with appropriate therapy (HR 1.01 [0.97‐1.05], P = .53). Patients with CCI ≥5 had an annual risk of death of 12.2% compared to 8.7% annual rate of appropriate therapy.ConclusionsCCI is predictive of mortality following ICD generator replacement. The benefit of ICD replacement in patients with CCI score ≥5 should be investigated in prospective studies.