Abstract Eosinophils are multifunctional cells of the innate immune system linked to allergic inflammation. Asthmatics were more likely to be hospitalized but less likely to suffer severe morbidity and mortality during the 2009 influenza pandemic. These epidemiologic findings were recapitulated in a mouse model of fungal asthma wherein infection during heightened allergic inflammation was protective against influenza A virus (IAV) infection and disease. Our goal was to delineate a mechanism(s) by which allergic asthma may alleviate influenza disease outcome, focused on the hypothesis that pulmonary eosinophilia linked with allergic respiratory disease is able to promote antiviral host defenses against the influenza virus. The transfer of eosinophils from the lungs of allergen-sensitized and challenged mice into influenza virus–infected mice resulted in reduced morbidity and viral burden, improved lung compliance, and increased CD8+ T cell numbers in the airways. In vitro assays with primary or bone marrow–derived eosinophils were used to determine eosinophil responses to the virus using the laboratory strain (A/PR/08/1934) or the pandemic strain (A/CA/04/2009) of IAV. Eosinophils were susceptible to IAV infection and responded by activation, piecemeal degranulation, and upregulation of Ag presentation markers. Virus- or viral peptide–exposed eosinophils induced CD8+ T cell proliferation, activation, and effector functions. Our data suggest that eosinophils promote host cellular immunity to reduce influenza virus replication in lungs, thereby providing a novel mechanism by which hosts with allergic asthma may be protected from influenza morbidity.
Echocardiographic diagnosis of total or left congenital pericardial absence with positional change
Objectives Congenital absence of the pericardium (CAP) is often confused with other conditions presenting with right ventricular dilatation and usually warrants CT or cardiac MR (CMR) to confirm. It would be desirable to have more specific echocardiographic criteria to provide a conclusive diagnosis. Methods 11 patients who were diagnosed with CAP (four patients with total CAP) based on CT/CMR were consecutively enrolled. Thirteen patients with atrial septal defect (ASD) and 16 normal subjects served as controls. To investigate spatial changes of heart in the thoracic cavity in CAP, following echocardiographic measurements were made in the left and right decubitus positions: the angle between the ultrasound beam and the left ventricular posterior wall (Angle-PW) in end-diastole at the parasternal long axis, and the distance between the chest wall and the most distal part of the left ventricular posterior wall (Distance-PW) at the parasternal mid-ventricular short axis. Results Angle-PW in patients with CAP were significantly greater than in those with ASD (100.1±12.5° vs 74.5±8.6°, p<0.017) or in normal subjects (100.1±12.5° vs 69.9±7.6°, p<0.017) at the left decubitus, and the difference in Angle-PW according to posture (left vs right) was significantly greater in CAP compared with the other groups (CAP 20.7±12.7°, ASD 0.31±1.80°, normal 0.31±1.40°, all p<0.017). The differences in Distance-PW according to patient position (CAP 2.43±0.77°, ASD 0.42±0.45°, normal 0.26±0.55°) or cardiac cycle in each position (left: CAP 1.60±0.76°, ASD 0.41±0.27°, normal 0.17±0.12°; right: CAP 0.70±0.32°, ASD 0.22±0.19°, normal 0.22±0.13°) were significantly higher in the CAP group than in the other groups (all p<0.017). Conclusions Patients with CAP have dynamic alteration in cardiac position depending on posture, which is not observed in ASD or in normal controls. Hence, total or left-sided CAP can be reliably diagnosed with positional changes during routine echocardiography.
A multi-reader in vitro study using porcine kidneys to determine the impact of integrated circuit detectors and iterative reconstruction on the detection accuracy, size measurement, and radiation dose for small (
Background Detection of small renal calculi has benefitted from recent advances in computed tomography (CT) scanner design. Information regarding observer performance when using state-of-the-art CT scanners for this application is needed. Purpose To assess observer performance and the impact of radiation dose for detection and size measurement of <4 mm renal stones using CT with integrated circuit detectors and iterative reconstruction. Material and Methods Twenty-nine <4 mm calcium oxalate stones were randomly placed in 20 porcine kidneys in an anthropomorphic phantom. Four radiologists used a workstation to record each calculus detection and size. JAFROC Figure of Merit (FOM), sensitivity, false positive detections, and calculus size were calculated. Results Mean calculus size was 2.2 ± 0.7 mm. The CTDI vol values corresponding to the automatic exposure control settings of 160, 80, 40, 25, and 10 Quality Reference mAs (QRM) were 15.2, 7.9, 4.2, 2.7, and 1.3 mGy, respectively. JAFROC FOM was ≥ 0.97 at ≥ 80 QRM, ≥ 0.89 at ≥ 25 QRM, and was inferior to routine dose (160 QRM) at 10 QRM (0.72, P < 0.05). Per-calculus sensitivity remained ≥ 85% for every reader at ≥ 25 QRM. Mean total false positive detections per reader were ≤ 3 at ≥ 80 QRM, but increased substantially for two readers ( ≥ 12) at ≤ 40 QRM. Measured calculus size significantly decreased at ≤ 25 QRM ( P ≤ 0.01). Conclusion Using low dose renal CT with iterative reconstruction and ≥ 25 QRM results in high sensitivity, but false positive detections increase for some readers at very low dose levels (≤ 40 QRM). At very low doses with iterative reconstruction, measured calculus size will artifactually decrease.
Skin Cancer Screening: Recommendations for Data-Driven Screening Guidelines and a review of the US Preventive Services Task Force Controversy
Abstract B25: The critical importance of the blood-brain barrier in modulating the response to otherwise highly effective targeted therapies in patient-derived orthotopic glioblastoma xenografts
Abstract Clinical data indicate that certain regions within glioblastoma (GBM) have a relatively intact blood-brain barrier (BBB), but controversy surrounds whether associated heterogeneous delivery may limit efficacy for otherwise highly active drugs with poor brain distribution. In this study, the efficacy of molecularly targeted therapies was compared in relevant GBM patient-derived xenograft (PDX) models grown either as heterotopic or orthotopic tumors. The impact of further disrupting BBB integrity in non-responsive orthotopic tumors was evaluated by over-expressing vascular endothelial growth factor (VEGF) and measuring drug distribution by matrix-assisted laser desorption ionization mass spectrometry imaging (MALDI-MSI). The brain:plasma ratio for five targeted agents was determined by LC-MSMS and treatment efficacy was evaluated in target-relevant GBM PDX lines: erlotinib (brain:plasma = 0.02 ± 0.02; efficacy tested in GBM6), palbociclib (brain:plasma = 0.06; efficacy tested in GBM22), AZD1775 (brain:plasma = 0.05; efficacy tested in GBM22), SAR405838 (brain:plasma = 0.01 ± 0.003; efficacy tested in GBM108), and AZD4547 (brain:plasma = 0.045 ± 0.02; efficacy tested in GBM150). Each of these drugs was effective in relevant GBM PDX flank tumor models with a 27% to 218% prolongation in the median time to exceed their pre-specified endpoint compared to placebo treatment (p≤0.02 for each drug). In contrast, none of these drugs were effective in prolonging survival in the same target-relevant orthotopic tumor models (-6% to 8% extension in median survival; p>0.05 for each drug). Consistent with partial and heterogeneous disruption of the BBB, MALDI-MSI of erlotinib, AZD1775 or SAR405838 distribution within orthotopic tumors demonstrated highly heterogeneous drug levels with large regions within each tumor approaching the low drug levels observed within surrounding normal brain. To further evaluate whether heterogenous drug distribution in orthotopic tumors could account for poor treatment efficacy, GBM108 was transduced with lentiviral constructs encoding for VEGF or empty vector (EV). While both GBM108-sublines were readily detectable with gadolinium-enhanced magnetic resonance imaging (MRI), the GBM108-VEGF tumors had a significantly more disrupted BBB, as evidenced by a more uniform and intense distribution of a brain-impenetrant TexasRed-dextran vascular marker. Similarly, the distribution of SAR405838, measured by MALDI-MSI, was markedly higher and more uniform in the GBM108-VEGF tumors when compared to the GBM108-EV tumors. Enhanced delivery of SAR405838 into orthotopic GBM108-VEGF models translated into a marked enhancement in treatment efficacy in comparison to GBM108-EV with a median survival prolongation of 37 vs. 4 days, respectively (p=0.0055). Collectively, these data highlight the importance of testing novel therapeutic agents in orthotopic tumor models and suggest that limited brain penetration for many molecules may significantly limit their efficacy in brain tumors that have a partially intact BBB. In the face of continued failure to develop effective targeted agents for GBM, these in vivo results highlight the importance of re-evaluating the dogma in neuro-oncology that the BBB is fully disrupted in GBM and, therefore, drug delivery across the BBB is not a major factor limiting treatment efficacy. Citation Format: Jann N. Sarkaria, David Calligaris, Daniel Ma, Karen Parrish, Ann C. Mladek, Janice Laramy, Minjee Kim, Shuangling Zhang, Mark Schroeder, Brett L. Carlson, Katrina Bakken, Aaron Johnson, Nathalie Agar, William Elmquist. The critical importance of the blood-brain barrier in modulating the response to otherwise highly effective targeted therapies in patient-derived orthotopic glioblastoma xenografts. [abstract]. In: Proceedings of the AACR Special Conference: Patient-Derived Cancer Models: Present and Future Applications from Basic Science to the Clinic; Feb 11-14, 2016; New Orleans, LA. Philadelphia (PA): AACR; Clin Cancer Res 2016;22(16_Suppl):Abstract nr B25.
Abstract P1-02-08: Provista-002: A prospective, multi-center study to determine the effectiveness of a biomarker assay to distinguish benign from invasive breast cancer in women with BI-RADS 3, 4 and 5 imaging reports
The purpose of this study was to introduce a planning strategy for dynamic conformal arc therapy (DCAT), named negative margin technique (NMT), and evaluate its dosimetric gain in lung stereotactic body radiation therapy (SBRT). In DCAT, the field aperture is continuously conformed to the planning target volume (PTV) with an aperture margin (AM) to compensate for the penumbra effect with gantry rotation. It is a common belief the AM should be positive (or at least ‘zero'). However, the radial penumbra width becomes significantly wider because of continuously overlapped beams in arc delivery. Therefore, we hypothesize if the ‘negative margin’ is applied in the radial direction, it would improve the PTV dose conformation while reducing normal tissue dose. For verification, trial plans were made using the NMT and compared with ‘zero margin (ZM)’ plans for five lung SBRT cases representing different situations depending on the location of the PTV and organs at risk. All plans met 95% PTV coverage with the prescription dose and spared the spinal cord below the tolerance. Two conventional conformation indices (the ratio of prescription isodose volume to the PTV (CI100) and the ratio of 50% prescription isodose volume to the PTV (CI50)) and a modified conformation index were investigated. The maximum dose at 2 cm from the PTV and the percent of lung volume receiving 20 Gy were also evaluated. Another planning simulation was performed with a total of ten randomly selected lung SBRT cases to mimic actual practice. In this simulation, optimization with ZM was first performed and further optimization using the NMT was processed for cases that could not meet a goal of with the ZM optimization. In all cases, both the and values were significantly reduced (overall, and for and , respectively). The modified conformation index values also showed similar improvement (overall, increase). Reduction of was also observed in all cases . values decreased in all cases but one (, excluding the increased case). In the random group simulation, it was possible to achieve the goal with just one NMT trial for five out of six cases that did not meet the goal in the ZM optimization. Interestingly, however, one case needed as many as six iterations to get the goal. The NMT turned out to be an effective planning strategy that could bring significant improvement of dose conformation. The NMT can be easily implemented in most clinics with no prerequisite.PACS number: 87.55.D‐
A static multi‐slit collimator system for scatter reduction in cone‐beam CT
A multiple‐slit collimator (MSC) design was introduced for scatter reduction in cone‐beam computed tomography (CBCT). Unlike most other collimators, the open and closed septa of the proposed MSC are placed in an equi‐angular interval on a circular track of the central sagittal plane. Therefore, one gantry rotation provides only the half of necessary dataset and two gantry rotations are needed to obtain full information. During the first gantry rotation, the MSC position relative to the source is fixed. For the second rotation, the MSC is rotated by the equi‐angle interval. We assume signals under the closed septa are totally attributed to scatter radiation. Then, scatter contributions under open septa are determined by interpolating them.Monte Carlo (MC) simulations for two virtual phantoms (one with a simple geometry and the other with two heterogeneities simulating the bone and the lung) were performed to evaluate the effectiveness of the system. Using the method developed, we could obtain images with significant scatter reduction. Contrast ratio (CR) improvement factors were 1.165 in a 2D projection view, and 1.210 and 1.223 at the central and peripheral slice of the reconstructed CBCT image of the simple geometry phantom.This preliminary study demonstrated that the proposed MSC, together with the imaging process technique, had a great potential to reduce scatter contribution in CBCT. Further studies will be performed to investigate the effect of various factors, such as reducing the detector size, increasing the number of history of MC simulation, and including many structures with different densities.PACS number: 87.57.C
An organ and effective dose study of XVI and OBI cone‐beam CT systems
The main purpose of this work was to quantify patient organ doses from the two kilovoltage cone beam computed tomography (CBCT) systems currently available on medical linear accelerators, namely the X‐ray Volumetric Imager (XVI, Elekta Oncology Systems) and the On‐Board Imager (OBI, Varian Medical Systems). Organ dose measurements were performed using a fiber‐optic coupled (FOC) dosimetry system along with an adult male anthropomorphic phantom for three different clinically relevant scan sites: head, chest, and pelvis. The FOC dosimeter was previously characterized at diagnostic energies by Hyer et al. [Med Phys 2009;36(5):1711–16] and a total uncertainty of approximately 4% was found for in‐phantom dose measurements. All scans were performed using current manufacturer‐installed clinical protocols and appropriate bow‐tie filters. A comparison of image quality between these manufacturer‐installed protocols was also performed using a Catphan 440 image quality phantom. Results indicated that for the XVI, the dose to the lens of the eye (1.07 mGy) was highest in a head scan, thyroid dose (19.24 mGy) was highest in a chest scan, and gonad dose (29 mGy) was highest in a pelvis scan. For the OBI, brain dose (3.01 mGy) was highest in a head scan, breast dose (5.34 mGy) was highest in a chest scan, and gonad dose (34.61 mGy) was highest in a pelvis scan. Image quality measurements demonstrated that the OBI provided superior image quality for all protocols, with both better spatial resolution and low‐contrast detectability. The measured organ doses were also used to calculate a reference male effective dose to allow further comparison of the two machines and imaging protocols. The head, chest, and pelvis scans yielded effective doses of 0.04, 7.15, and 3.73 mSv for the XVI, and 0.12, 1.82, and 4.34 mSv for the OBI, respectively.PACS number: 87.57.uq