Systemic vasculitides are a rare and complex group of diseases that can affect multiple organ systems. Clinically, presentation may be vague and non-specific and as such, diagnosis and subsequent management are challenging. These entities are typically classified by the size of vessel involved, including large-vessel vasculitis (giant cell arteritis, Takayasu’s arteritis, and clinically isolated aortitis), medium-vessel vasculitis (including polyarteritis nodosa and Kawasaki disease), and small-vessel vasculitis (granulomatosis with polyangiitis and eosinophilic granulomatosis with polyangiitis). There are also other systemic vasculitides that do not fit in to these categories, such as Behcet’s disease, Cogan syndrome, and IgG4-related disease. Advances in medical imaging modalities have revolutionized the approach to diagnosis of these diseases. Specifically, color Doppler ultrasound, computed tomography and angiography, magnetic resonance imaging, positron emission tomography, or invasive catheterization as indicated have become fundamental in the work up of any patient with suspected systemic or localized vasculitis. This review presents the key diagnostic imaging modalities and their clinical utility in the evaluation of systemic vasculitis.
Atrial Shunt Device Effects on Cardiac Structure and Function in Heart Failure With Preserved Ejection Fraction
Importance Although the results of A Study to Evaluate the Corvia Medical Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure (REDUCE LAP-HF II) trial were neutral overall, atrial shunt therapy demonstrated potential efficacy in responders (no latent pulmonary vascular disease and no cardiac rhythm management device). Post hoc analyses were conducted to evaluate the effect of shunt vs sham stratified by responder status. Objective To evaluate the effect of atrial shunt vs sham control on cardiac structure/function in the overall study and stratified by responder status. Design, Setting, and Participants This was a sham-controlled randomized clinical trial of an atrial shunt device in heart failure with preserved ejection fraction (HFpEF)/HF with mildly reduced EF (HFmrEF). Trial participants with evaluable echocardiography scans were recruited from 89 international medical centers. Data were analyzed from April 2023 to January 2024. Interventions Atrial shunt device or sham control. Main Outcome Measures Changes in echocardiographic measures from baseline to 1, 6, 12, and 24 months after index procedure. Results The modified intention-to-treat analysis of the REDUCE LAP-HF II trial included 621 randomized patients (median [IQR] age, 72.0 [66.0-77.0] years; 382 female [61.5%]; shunt arm, 309 [49.8%]; sham control arm, 312 [50.2%]). Through 24 months, 212 of 217 patients (98%) in the shunt arm with evaluable echocardiograms had patent shunts. In the overall trial population, the shunt reduced left ventricular (LV) end-diastolic volume (mean difference, −5.65 mL; P <.001), left atrial (LA) minimal volume (mean difference, −2.8 mL; P =.01), and improved LV systolic tissue Doppler velocity (mean difference, 0.69 cm/s; P <.001) and LA emptying fraction (mean difference, 1.88 percentage units; P =.02) compared with sham. Shunt treatment also increased right ventricular (RV; mean difference, 9.58 mL; P <.001) and right atrial (RA; mean difference, 9.71 mL; P <.001) volumes but had no effect on RV systolic function, pulmonary artery pressure, or RA pressure compared with sham. In the shunt arm, responders had smaller increases in RV end-diastolic volume (mean difference, 5.71 mL vs 15.18 mL; interaction P =.01), RV end-systolic volume (mean difference, 1.58 mL vs 7.89 mL; interaction P =.002), and RV/LV ratio (mean difference, 0.07 vs 0.20; interaction P <.001) and larger increases in transmitral A wave velocity (mean difference, 5.08 cm/s vs −1.97 cm/s; interaction P =.02) compared with nonresponders randomized to the shunt, suggesting greater ability to accommodate shunted blood through the pulmonary circulation enabling LA unloading. Conclusions and Relevance In this post hoc analysis of the REDUCE LAP-HF II trial, over 2 years of follow-up, atrial shunting led to reverse remodeling of left-sided chambers and increases in volume of right-sided chambers consistent with the shunt flow but no change in RV systolic function compared with sham. Changes in cardiac structure/function were more favorable in responders compared with nonresponders treated with the shunt, supporting the previously identified responder group hypothesis and mechanism, although further evaluation with longer follow-up is needed. Trial Registration ClinicalTrials.gov Identifier: NCT03088033
5-Year Follow-Up of a Physician Performance Feedback Report Intervention to Reduce Overuse and Excess Cost: A National Cohort Study
BACKGROUND Mohs micrographic surgery efficiently treats skin cancer through staged resection, but surgeons' varying resection rates may lead to higher medical costs. OBJECTIVE To evaluate the cost savings associated with a quality improvement. MATERIALS AND METHODS The authors conducted a retrospective cohort study using 100% Medicare fee-for-service claims data to identify the change of mean stages per case for head/neck (HN) and trunk/extremity (TE) lesions before and after the quality improvement intervention from 2016 to 2021. They evaluated surgeon-level change in mean stages per case between the intervention and control groups, as well as the cost savings to Medicare over the same time period. RESULTS A total of 2,014 surgeons performed Mohs procedures on HN lesions. Among outlier surgeons who were notified, 31 surgeons (94%) for HN and 24 surgeons (89%) for TE reduced their mean stages per case with a median reduction of 0.16 and 0.21 stages, respectively. Reductions were also observed among outlier surgeons who were not notified, reducing their mean stages per case by 0.1 and 0.15 stages, respectively. The associated total 5-year savings after the intervention was 92 million USD. CONCLUSION The implementation of this physician-led benchmarking model was associated with broad reductions of physician utilization and significant cost savings.
Semaglutide in Patients with Obesity-Related Heart Failure and Type 2 Diabetes
Cardiovascular Effects of Oral Ketone Ester Treatment in Patients With Heart Failure With Reduced Ejection Fraction: A Randomized, Controlled, Double-Blind Trial
BACKGROUND: Heart failure triggers a shift in myocardial metabolic substrate utilization, favoring the ketone body 3-hydroxybutyrate as energy source. We hypothesized that 14-day treatment with ketone ester (KE) would improve resting and exercise hemodynamics and exercise capacity in patients with heart failure with reduced ejection fraction. METHODS: In a randomized, double-blind cross-over study, nondiabetic patients with heart failure with reduced ejection fraction received 14-day KE and 14-day isocaloric non-KE comparator regimens of 4 daily doses separated by a 14-day washout period. After each treatment period, participants underwent right heart catheterization, echocardiography, and blood sampling at plasma trough levels and after dosing. Participants underwent an exercise hemodynamic assessment after a second dosing. The primary end point was resting cardiac output (CO). Secondary end points included resting and exercise pulmonary capillary wedge pressure and peak exercise CO and metabolic equivalents. RESULTS: We included 24 patients with heart failure with reduced ejection fraction (17 men; 65±9 years of age; all White). Resting CO at trough levels was higher after KE compared with isocaloric comparator (5.2±1.1 L/min versus 5.0±1.1 L/min; difference, 0.3 L/min [95% CI, 0.1–0.5), and pulmonary capillary wedge pressure was lower (8±3 mm Hg versus 11±3 mm Hg; difference, −2 mm Hg [95% CI, −4 to −1]). These changes were amplified after KE dosing. Across all exercise intensities, KE treatment was associated with lower mean exercise pulmonary capillary wedge pressure (−3 mm Hg [95% CI, −5 to −1] ) and higher mean CO (0.5 L/min [95% CI, 0.1–0.8]), significantly different at low to moderate steady-state exercise but not at peak. Metabolic equivalents remained similar between treatments. In exploratory analyses, KE treatment was associated with 18% lower NT-proBNP (N-terminal pro-B-type natriuretic peptide; difference, −98 ng/L [95% CI, −185 to −23]), higher left ventricular ejection fraction (37±5 versus 34±5%; P =0.01), and lower left atrial and ventricular volumes. CONCLUSIONS: KE treatment for 14 days was associated with higher CO at rest and lower filling pressures, cardiac volumes, and NT-proBNP levels compared with isocaloric comparator. These changes persisted during exercise and were achieved on top of optimal medical therapy. Sustained modulation of circulating ketone bodies is a potential treatment principle in patients with heart failure with reduced ejection fraction. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT05161650.
Cardiac Allograft Vasculopathy: Challenges and Advances in Invasive and Non-Invasive Diagnostic Modalities
Cardiac allograft vasculopathy (CAV) is a distinct form of coronary artery disease that represents a major cause of death beyond the first year after heart transplantation. The pathophysiology of CAV is still not completely elucidated; it involves progressive circumferential wall thickening of both the epicardial and intramyocardial coronary arteries. Coronary angiography is still considered the gold-standard test for the diagnosis of CAV, and intravascular ultrasound (IVUS) can detect early intimal thickening with improved sensitivity. However, these tests are invasive and are unable to visualize and evaluate coronary microcirculation. Increasing evidence for non-invasive surveillance techniques assessing both epicardial and microvascular components of CAV may help improve early detection. These include computed tomography coronary angiography (CTCA), single-photon emission computed tomography (SPECT), positron emission tomography (PET), and vasodilator stress myocardial contrast echocardiography perfusion imaging. This review summarizes the current state of diagnostic modalities and their utility and prognostic value for CAV and also evaluates emerging tools that may improve the early detection of this complex disease.
Role of Genetics in Diagnosis and Management of Hypertrophic Cardiomyopathy: A Glimpse into the Future
Hypertrophic cardiomyopathy (HCM) is the most common inherited cardiomyopathy. It follows an autosomal dominant inheritance pattern in most cases, with incomplete penetrance and heterogeneity. It is familial in 60% of cases and most of these are caused by pathogenic variants in the core sarcomeric genes (MYH7, MYBPC3, TNNT2, TNNI3, MYL2, MYL3, TPM1, ACTC1). Genetic testing using targeted disease-specific panels that utilize next-generation sequencing (NGS) and include sarcomeric genes with the strongest evidence of association and syndrome-associated genes is highly recommended for every HCM patient to confirm the diagnosis, identify the molecular etiology, and guide screening and management. The yield of genetic testing for a disease-causing variant is 30% in sporadic cases and up to 60% in familial cases and in younger patients with typical asymmetrical septal hypertrophy. Genetic testing remains challenging in the interpretation of results and classification of variants. Therefore, in 2015 the American College of Medical Genetics and Genomics (ACMG) established guidelines to classify and interpret the variants with an emphasis on the necessity of periodic reassessment of variant classification as genetic knowledge rapidly expands. The current guidelines recommend focused cascade genetic testing regardless of age in phenotype-negative first-degree relatives if a variant with decisive evidence of pathogenicity has been identified in the proband. Genetic test results in family members guide longitudinal clinical surveillance. At present, there is emerging evidence for genetic test application in risk stratification and management but its implementation into clinical practice needs further study. Promising fields such as gene therapy and implementation of artificial intelligence in the diagnosis of HCM are emerging and paving the way for more effective screening and management, but many challenges and obstacles need to be overcome before establishing the practical implications of these new methods.
Prevalence and drivers of nurse and physician distress in cardiovascular and oncology programmes at a Canadian quaternary hospital network during the COVID-19 pandemic: a quality improvement initiative
Objectives To assess the prevalence and drivers of distress, a composite of burnout, decreased meaning in work, severe fatigue, poor work–life integration and quality of life, and suicidal ideation, among nurses and physicians during the COVID-19 pandemic. Design Cross-sectional design to evaluate distress levels of nurses and physicians during the COVID-19 pandemic between June and August 2021. Setting Cardiovascular and oncology care settings at a Canadian quaternary hospital network. Participants 261 nurses and 167 physicians working in cardiovascular or oncology care. Response rate was 29% (428 of 1480). Outcome measures Survey tool to measure clinician distress using the Well-Being Index (WBI) and additional questions about workplace-related and COVID-19 pandemic-related factors. Results Among 428 respondents, nurses (82%, 214 of 261) and physicians (62%, 104 of 167) reported high distress on the WBI survey. Higher WBI scores (≥2) in nurses were associated with perceived inadequate staffing (174 (86%) vs 28 (64%), p=0.003), unfair treatment, (105 (52%) vs 11 (25%), p=0.005), and pandemic-related impact at work (162 (80%) vs 22 (50%), p<0.001) and in their personal life (135 (67%) vs 11 (25%), p<0.001), interfering with job performance. Higher WBI scores (≥3) in physicians were associated with perceived inadequate staffing (81 (79%) vs 32 (52%), p=0.001), unfair treatment (44 (43%) vs 13 (21%), p=0.02), professional dissatisfaction (29 (28%) vs 5 (8%), p=0.008), and pandemic-related impact at work (84 (82%) vs 35 (56%), p=0.001) and in their personal life (56 (54%) vs 24 (39%), p=0.014), interfering with job performance. Conclusion High distress was common among nurses and physicians working in cardiovascular and oncology care settings during the pandemic and linked to factors within and beyond the workplace. These results underscore the complex and contextual aspects of clinician distress, and the need to develop targeted approaches to effectively address this problem.
Brepocitinib, Zimlovisertib, and Ropsacitinib in Hidradenitis Suppurativa
Exposure to high altitude results in hypobaric hypoxia, leading to physiological changes in the cardiovascular system that may result in limiting symptoms, including dyspnea, fatigue, and exercise intolerance. However, it is still unclear why some patients are more susceptible to high-altitude symptoms than others. Hypoxic simulation testing (HST) simulates changes in physiology that occur at a specific altitude by asking the patients to breathe a mixture of gases with decreased oxygen content. This study aimed to determine whether the use of transthoracic echocardiography (TTE) during HST can detect the rise in right-sided pressures and the impact of hypoxia on right ventricle (RV) hemodynamics and right to left shunts, thus revealing the underlying causes of high-altitude signs and symptoms. A retrospective study was performed including consecutive patients with unexplained dyspnea at high altitude. HSTs were performed by administrating reduced FiO2 to simulate altitude levels specific to patients’ history. Echocardiography images were obtained at baseline and during hypoxia. The study included 27 patients, with a mean age of 65 years, 14 patients (51.9%) were female. RV systolic pressure increased at peak hypoxia, while RV systolic function declined as shown by a significant decrease in the tricuspid annular plane systolic excursion (TAPSE), the maximum velocity achieved by the lateral tricuspid annulus during systole (S’ wave), and the RV free wall longitudinal strain. Additionally, right-to-left shunt was present in 19 (70.4%) patients as identified by bubble contrast injections. Among these, the severity of the shunt increased at peak hypoxia in eight cases (42.1%), and the shunt was only evident during hypoxia in seven patients (36.8%). In conclusion, the use of TTE during HST provides valuable information by revealing the presence of symptomatic, sustained shunts and confirming the decline in RV hemodynamics, thus potentially explaining dyspnea at high altitude. Further studies are needed to establish the optimal clinical role of this physiologic method.