Citations

Clear

4610 citation(s) found for "Lu, Brian".

Genomewide Association Studies of LRRK2 Modifiers of Parkinson's Disease
Lai, Dongbing , Fontanillas, Pierre , Aasly, Jan , Beecham, Gary W. , Berg, Daniela , Bressman, Susan , Brockmann, Kathrin , Clark, Lorraine N. , Cookson, Mark , Das, Sayantan , Farrer, Matthew J. , Trinh, Joanne , Gasser, Thomas , Gustavsson, Emil K. , Klein, Christine , Langston, J. William, Lynch, Timothy , Marder, Karen, Martin, Eden R. , Mejia‐Santana, Helen, Molho, Eric , Nuytemans, Karen , Ozelius, Laurie J. , Raymond, Deborah , Ross, Owen A. , Samii, Ali, Saunders‐Pullman, Rachel , Schüle, Birgitt , Tolosa, Eduardo , Tomkins, James E. , Vilas, Dolores , Trojanowski, John Q. , Uitti, Ryan J. , Zabetian, Cyrus P. , Urtreger, Avi Orr, Cannon, P. F. , Fiske, Brian , Brockman, Kathrin , Klein, Christine , Ross, Owen A , Uitti, Ryan, Visanji, Naomi P , Zabetian, Cyrus P , Mirelman, Anat , Alipanahi, Babak , Schwantes-An, Tae-Hwi Linus , Alcalay, Roy N. , Brice, Alexis , Deerlin, Vivianna M. Van , Follett, Jordan , Goldwurm, Stefano , Lang, Anthony E. , Latourelle, Jeanne C. , Marras, Connie , McLean, Cory Y. , Myers, Richard H. , Payami, Haydeh , Rogaeva, Ekaterina A. , Rogers, Michael P. , Schulte, Claudia , Scott, William K. , Tanner, Caroline M. , Vance, Jeffery M. , Visanji, Naomi P. , Wszołek, Zbigniew K. , Giladi, Nir , Foroud, Tatiana

Mayo Clinic

Annals of Neurology | May 3, 2021 | Volume: 90 | Issue: 1 | Pages: 76-88

10.1002/ana.26094 | PMID 33938021 Get It

Objective The aim of this study was to search for genes/variants that modify the effect of LRRK2 mutations in terms of penetrance and age‐at‐onset of Parkinson's disease. Methods We performed the first genomewide association study of penetrance and age‐at‐onset of Parkinson's disease in LRRK2 mutation carriers (776 cases and 1,103 non‐cases at their last evaluation). Cox proportional hazard models and linear mixed models were used to identify modifiers of penetrance and age‐at‐onset of LRRK2 mutations, respectively. We also investigated whether a polygenic risk score derived from a published genomewide association study of Parkinson's disease was able to explain variability in penetrance and age‐at‐onset in LRRK2 mutation carriers. Results A variant located in the intronic region of CORO1C on chromosome 12 (rs77395454; p value = 2.5E‐08, beta = 1.27, SE = 0.23, risk allele: C) met genomewide significance for the penetrance model. Co‐immunoprecipitation analyses of LRRK2 and CORO1C supported an interaction between these 2 proteins. A region on chromosome 3, within a previously reported linkage peak for Parkinson's disease susceptibility, showed suggestive associations in both models (penetrance top variant: p value = 1.1E‐07; age‐at‐onset top variant: p value = 9.3E‐07). A polygenic risk score derived from publicly available Parkinson's disease summary statistics was a significant predictor of penetrance, but not of age‐at‐onset. Interpretation This study suggests that variants within or near CORO1C may modify the penetrance of LRRK2 mutations. In addition, common Parkinson's disease associated variants collectively increase the penetrance of LRRK2 mutations. ANN NEUROL 2021;90:82–94
Carotid Stenting: Flow Reversal Technique: 2-Dimensional Operative Video
Domingo, Ricardo A. , Ravindran, Krishnan , Tawk, Rabih G. , Bain, Mark, Bendock, Bernard, Binning, Mandy J., Boulos, Alan S. , Crowley, Webster, Fessler, Richard D., Guterman, Lee R., Hoit, Daniel , Hopkins, L. Nelson , Howington, Jay U., James, Robert F. , Jankowitz, Brian T. , Kan, Peter , Khalessi, Alex A, Kim, Louis J. , Langer, David J. , Mack, William J. , Mericle, Robert A., Ogilvy, Chris, Replogle, Robert, Riina, Howard A. , Saugaveau, Eric, Schirmer, Clemens M. , Spiotta, Alex, Turner, Raymond D , Veznedaroglu, Erol, Welch, Babu G. , Tawk, Rabih G , Schirmer, Clemens M , Domingo, Ricardo A , Arthur, Adam Stephen , Grande, Andrew Walker , Hanel, Ricardó A. , Kim, Louis J. , Lanzino, Giuseppe , Levitt, Michael R. , Levy, Elad I. , Lopes, Demetrius K. , Mocco, J , Pandey, Aditya S , Ringer, Andrew J. , Rodriguez, Rafael, Siddiqui, Adnan H. , Aziz‐Sultan, Mohammad Ali , Thomas, Ajith J , White, Jonathan Samuel

Mayo Clinic

Operative Neurosurgery | April 30, 2021 | Volume: 21 | Issue: 2 | Pages: E111-E112

10.1093/ons/opab119 | PMID 33929024 Get It

Abstract Management options for carotid stenosis include medical management, carotid endarterectomy, carotid stenting with distal filter protection, or stenting with either flow arrest or flow reversal techniques. 1 Flow reversal with transcarotid artery revascularization (TCAR) technique represents a hybrid approach with surgical access to the common carotid for endovascular placement of a stent in the internal carotid artery. This direct access to the carotid artery avoids navigating the challenging anatomy of the aortic arch with endovascular devices. 2 Compared to transfemoral stenting, TCAR possesses lower risk of transient ischemic attack and stroke, and compared to carotid endarterectomy, there is less risk of cranial neuropathy. 3,4 We present the case of an 87-yr-old man with recurrent severe stenosis (85%) of the right internal carotid artery. The patient had a remote history of bilateral endarterectomies for asymptomatic stenosis and was found with recurrence and progression of right internal carotid artery stenosis. Options were discussed and decision was made to proceed with TCAR after he consented for the procedure. The patient tolerated the procedure well with satisfactory revascularization. Exam remained unremarkable prior to discharge on postoperative day 1 and during follow-up at 1 mo. Patient consented to the publication of their image.
Promoting Neuronal Outgrowth Using Ridged Scaffolds Coated with Extracellular Matrix Proteins
Siddiqui, Ahad M. , Brunner, Rosa, Harris, Greg M. , Miller, A. Lee , Waletzki, Brian E., Schmeichel, Ann M., Schwarzbauer, Jean E. , Yaszemski, Michael J. , Windebank, Anthony J. , Madigan, Nicolas N. , Harris, Gregory M , Miller, Alan Lee , Madigan, Nicolas N , Schwartz, Jeffrey

Mayo Clinic

Biomedicines | April 27, 2021 | Volume: 9 | Issue: 5 | Pages: 479

10.3390/biomedicines9050479 | PMID 33925613 Get It

Spinal cord injury (SCI) results in cell death, demyelination, and axonal loss. The spinal cord has a limited ability to regenerate, and current clinical therapies for SCI are not effective in helping promote neurologic recovery. We have developed a novel scaffold biomaterial that is fabricated from the biodegradable hydrogel oligo(poly(ethylene glycol)fumarate) (OPF). We have previously shown that positively charged OPF scaffolds (OPF+) in an open spaced, multichannel design can be loaded with Schwann cells to support axonal generation and functional recovery following SCI. We have now developed a hybrid OPF+ biomaterial that increases the surface area available for cell attachment and that contains an aligned microarchitecture and extracellular matrix (ECM) proteins to better support axonal regeneration. OPF+ was fabricated as 0.08 mm thick sheets containing 100 μm high polymer ridges that self-assemble into a spiral shape when hydrated. Laminin, fibronectin, or collagen I coating promoted neuron attachment and axonal outgrowth on the scaffold surface. In addition, the ridges aligned axons in a longitudinal bipolar orientation. Decreasing the space between the ridges increased the number of cells and neurites aligned in the direction of the ridge. Schwann cells seeded on laminin coated OPF+ sheets aligned along the ridges over a 6-day period and could myelinate dorsal root ganglion neurons over 4 weeks. This novel scaffold design, with closer spaced ridges and Schwann cells, is a novel biomaterial construct to promote regeneration after SCI.
Clinical and Radiological Safety of Retained Implantable Doppler Devices Used for Free Flap Monitoring
Kreutz‐Rodrigues, Lucas , Carlsen, Brian T. , Frick, Matthew A., Bakri, Karim , Gibreel, Waleed , Mardini, Samir

Mayo Clinic

Plastic Surgery | April 27, 2021 | Volume: 30 | Issue: 1 | Pages: 20-24

10.1177/22925503211006537 | PMID 35096688 Get It

Introduction: Implantable Doppler devices are reliable adjuncts used for free flap monitoring. Occasionally, the probe/wire is not removed and remains in the soft tissues. The clinical safety of the retained probes and safety and compatibility with magnetic resonance imaging (MRI) have not been studied. We present a series of retained implantable Doppler probes examining clinic outcomes, safety and compatibility with MRI, and effect on MRI image quality. Methods: A retrospective review was conducted of patients who had an implantable Doppler device for free flap monitoring between July 2007 and August 2018. Routine post-operative imaging was reviewed for all patients to identify incidental findings of a retained probe. A subset of patients with retained implantable Doppler probes who underwent MRI was identified. Magnetic resonance images were reviewed to detect any degradation of image quality. Results: A total of 323 patients who had an implantable Doppler device placed were reviewed 18 (5.6%) patients were identified with a retained probe and were included in this study. Mean age was 49 years with mean follow-up of 34.4 months. One potential device-related complication occurred in 1 (5.6%) patient. A total of 32 MRI scans were performed in 8 patients with retained devices, including 6 patients who underwent a total of 21 MRIs of the surgical site. There were no complications related to the MRI scans, and we found no significant degradation of image quality. Conclusion: Retained implantable Doppler probes were not associated with substantial adverse clinical outcomes nor affected MRI image quality of the surgical site.
Somatosensory evoked potentials and Hirayama disease
Zubair, Adeel , Crum, Brian, Crum, Brian A.

Mayo Clinic

Surgical Neurology International | April 25, 2021 | Volume: 12 | Issue: No issue available | Pages: 190

10.25259/sni_88_2021 | PMID 34084618 Get It

The Importance of Financial Metrics in Physician Funding and Performance Evaluation
Patrinely, James R. , Walker, Sallie, Glassman, Gabriella E. , Davis, Matthew J. , Khan, Umraz , Drolet, Brian C. , Forte, Antonio J. , Patrinely, J Randall, Walker, Sallie H, Abu-Ghname, Amjed, Perdikis, Galen, Forte, Antonio Jorge , Abu‐Ghname, Amjed , Perdikis, Galen

Mayo Clinic

Plastic & Reconstructive Surgery | April 23, 2021 | Volume: 147 | Issue: 5 | Pages: 1213-1218

10.1097/prs.0000000000007882 | PMID 33890907 Get It

Background: Financial key performance indicators are often used to evaluate performance. Understanding of key performance indicators can be crucial for career advancement and bargaining leverage in resource negotiations. This study aimed to identify the most important key performance indicators used in surgical funding requests and understand how to use these metrics in clinical practice. Methods: In two tertiary medical centers, funding requests for surgeon gap support (2019 to 2020) and equipment (2017 to 2019) within departments of surgery were reviewed. The requesting department, approval status, and amount allotted were recorded. In requests for gap support, projections for contribution margin, operating room volume, charges, collections, and relative value units were tracked. Projected contribution margin and cost savings were recorded for equipment funding requests. Results: There were 40 gap support and 24 equipment requests, and all were approved. Most gap support requests included collections (90.0 percent), charges (87.5 percent), operating room cases (80.0 percent), relative value units (77.5 percent), and hospital contribution margin (77.5 percent). The most represented departments were general surgery (37.5 percent), neurosurgery (22.5 percent), and plastic surgery (15.0 percent). The departments that submitted the most equipment requests were general surgery (28.0 percent) and neurosurgery (28.0 percent). Most requests included projections for contribution margin (95.8 percent) and cost savings (87.4 percent). Projected hospital contribution margin correlated with the amount of funds allotted for surgeon support (r = 0.409; p = 0.022). Conclusions: This multicenter study identified the importance of using key performance indicators for a successful financial outcome in funding requests. In addition, the authors demonstrate the need for surgeons to understand their own key performance indicators. Surgeons should advocate for increased transparency to better understand their financial contributions and performance.
Intracranial Access: Dural Venous Sinus Stenting: 2-Dimensional Operative Video
Domingo, Ricardo A. , Ravindran, Krishnan , Kulakova, Katya, Tawk, Rabih G. , Bain, Mark, Bendock, Bernard, Binning, Mandy J., Boulos, Alan S. , Crowley, Webster, Fessler, Richard D., Guterman, Lee R., Hoit, Daniel , Hopkins, L. Nelson , Howington, Jay U., James, Robert F. , Jankowitz, Brian T. , Kan, Peter , Khalessi, Alex A, Kim, Louis J. , Langer, David J. , Mack, William J. , Mericle, Robert A., Ogilvy, Chris, Replogle, Robert, Riina, Howard A. , Saugaveau, Eric, Schirmer, Clemens M. , Spiotta, Alex, Sultan, Ali, Turner, Raymond D , Veznedaroglu, Erol, Welch, Babu G. , White, Jonathan, Tawk, Rabih G , Schirmer, Clemens M , Domingo, Ricardo A , Arthur, Adam Stephen , Grande, Andrew Walker , Hanel, Ricardó A. , Kim, Louis J. , Lanzino, Giuseppe , Levitt, Michael R. , Levy, Elad I. , Lopes, Demetrius K. , Mocco, J , Pandey, Aditya S , Ringer, Andrew J. , Rodriguez, Rafael, Siddiqui, Adnan H. , Thomas, Ajith J , White, Jonathan A.

Mayo Clinic

Operative Neurosurgery | April 23, 2021 | Volume: 21 | Issue: 2 | Pages: E113-E114

10.1093/ons/opab120 | PMID 33891009 Get It

Abstract Cerebral venous sinus stenting has gained popularity in recent years as a safe and efficacious treatment of selected patients with idiopathic intracranial hypertension (IIH) and focal venous sinus stenosis.1–3 - 3 The main goal of treatment is to prevent visual loss, and often patients report resolution of headache and visual symptoms within 21 mo of mean follow-up.4–8 - 8 We present the case of a 57-yr-old woman with medically refractory IIH, bilateral sinus stenosis, and a mass lesion causing stenosis on the left. Venous angiogram with pressure monitoring was completed with the patient awake, which showed a significant pressure gradient on the right (19 mm Hg) and borderline gradient on the left (8 mm Hg). Options were reviewed and decision was made to proceed with the treatment of the right-sided stenosis with stenting and continue with the observation of the lesion on the left to prevent further visual deterioration. The patient consented for the procedure, and she tolerated the procedure well. Neurological exam remained at baseline, and she was discharged home on post-operative day #1. At 2 mo’s follow-up, the patient reported improvement in headaches and remained intact neurologically.
Global Differences in Heart Failure With Preserved Ejection Fraction
Claggett, Brian , Jackson, Alice M. , Køber, Lars , Chopra, Vijay , Chen, Chen‐Huan , Maggioni, Aldo P. , Martínez, Felipe A. , Pieske, Burkert , Redfield, Margaret M. , Rouleau, Jean L. , Veldhuisen, Dirk J. van , Zannad, Faı̈ez , Rizkala, Adel R. , Inubushi-Molessa, Akiko, Lefkowitz, Martin, Shi, Victor , McMurray, John J.V. , Solomon, Scott D. , Investigators, on behalf of the PARAGON-HF, Maggioni, Aldo P , McMurray, John J V , Køber, Lars , Tromp, Jasper , Liu, Jiankang , Jhund, Pardeep S. , Jr., Jiri Widimsky , Boytsov, S. А. , Anand, Inder S. , Ge, Junbo , Packer, Milton , Pfeffer, Marc Alan , Zile, Michael R. , Solomon, Scott David , Lam, Carolyn S.P. , Investigators, on behalf of the PARAGON-HF

Mayo Clinic

Circulation: Heart Failure | April 19, 2021 | Volume: 14 | Issue: 4 | Pages: No page available

10.1161/circheartfailure.120.007901 | PMID 33866828 Get It

Background: Heart failure with preserved ejection fraction (HFpEF) is a global public health problem with important regional differences. We investigated these differences in the PARAGON-HF trial (Prospective Comparison of Angiotensin Receptor Neprilysin Inhibitor With Angiotensin Receptor Blocker Global Outcomes in HFpEF), the largest and most inclusive global HFpEF trial. Methods: We studied differences in clinical characteristics, outcomes, and treatment effects of sacubitril/valsartan in 4796 patients with HFpEF from the PARAGON-HF trial, grouped according to geographic region. Results: Regional differences in patient characteristics and comorbidities were observed: patients from Western Europe were oldest (mean 75±7 years) with the highest prevalence of atrial fibrillation/flutter (36%); Central/Eastern European patients were youngest (mean 71±8 years) with the highest prevalence of coronary artery disease (50%); North American patients had the highest prevalence of obesity (65%) and diabetes (49%); Latin American patients were younger (73±9 years) and had a high prevalence of obesity (53%); and Asia-Pacific patients had a high prevalence of diabetes (44%), despite a low prevalence of obesity (26%). Rates of the primary composite end point of total hospitalizations for HF and death from cardiovascular causes were lower in patients from Central Europe (9 per 100 patient-years) and highest in patients from North America (28 per 100 patient-years), which was primarily driven by a greater number of total hospitalizations for HF. The effect of treatment with sacubitril-valsartan was not modified by region (interaction P >0.05). Conclusions: Among patients with HFpEF recruited worldwide in PARAGON-HF, there were important regional differences in clinical characteristics and outcomes, which may have implications for the design of future clinical trials. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01920711.
Endovascular Treatment of Basilar Bifurcation Aneurysms With PulseRider-Assisted Coiling: 2-Dimensional Operative Video
Sattur, Mithun G. , Kasab, Sami Al , Spiotta, Alejandro M , Bain, Mark, Bendock, Bernard, Binning, Mandy J., Boulos, Alan S. , Crowley, Webster, Fessler, Richard D., Guterman, Lee R., Hoit, Daniel , Hopkins, L. Nelson , Howington, Jay U., James, Robert F. , Jankowitz, Brian T. , Kan, Peter , Khalessi, Alex A, Kim, Louis J. , Langer, David J. , Mack, William J. , Mericle, Robert A., Ogilvy, Chris, Replogle, Robert, Riina, Howard A. , Saugaveau, Eric, Schirmer, Clemens M. , Spiotta, Alex, Sultan, Ali, Turner, Raymond, Veznedaroglu, Erol, Welch, Babu G. , White, Jonathan, Spiotta, Alejandro M , Schirmer, Clemens M , Porto, Guilherme , Arthur, Adam Stephen , Grande, Andrew Walker , Hanel, Ricardó A. , Kim, Louis J. , Lanzino, Giuseppe , Levitt, Michael R. , Levy, Elad I. , Lopes, Demetrius K. , Mocco, J , Pandey, Aditya S , Ringer, Andrew J. , Rodriguez, Rafael, Siddiqui, Adnan H. , Tawk, Rabih G. , Thomas, Ajith J , White, Jonathan A.

Mayo Clinic

Operative Neurosurgery | April 17, 2021 | Volume: 21 | Issue: 2 | Pages: E109-E110

10.1093/ons/opab102 | PMID 33861344 Get It

Abstract Wide-necked bifurcation aneurysms pose technical and anatomical challenges to endovascular treatment, which make the simpler assisted (balloon or single stent) coiling techniques less effective. 1 Consequently, unique endovascular solutions to treat such aneurysms have been devised. 2,3 One such device is PulseRider (Cerenovus, New Brunswick, New Jersey), which is designed to provide neck support for a coil mass while protecting the bifurcation. 3 The device comprises a body or stem that is deployed in the parent artery and a saddle component that sits at the aneurysm neck to keep the coil mass away from the bifurcation. There are several technical nuances involved in successful use of the device during positioning, deployment, and detachment. 3 We present a surgical video detailing the steps of PulseRider-assisted coiling of unruptured basilar bifurcation (or basilar apex) aneurysms. The first case highlights index treatment at diagnosis and the second showcases treatment of a recurrent basilar apex aneurysm. Both patients provided informed consent to the procedure. We also briefly discuss the rationale for treating basilar apex aneurysms. 4,5