Citations

Clear

252 citation(s) found for "Stuart, Michael J".

CT and MRI Measurements of Tibial Tubercle–Trochlear Groove Distances Are Not Equivalent in Patients With Patellar Instability
Camp, Christopher L. , Krych, Aaron J. , Levy, Bruce A. , Bond, Jeffrey R., Collins, Mark S., Dahm, Diane L., Camp, Christopher L. , Stuart, Michael J. , Krych, Aaron J

Mayo Clinic

The American Journal of Sports Medicine | July 15, 2013 | Volume: 41 | Issue: 8 | Pages: 1835-1840

10.1177/0363546513484895 | PMID 23857884 Get It

Background: Tibial tubercle–trochlear groove distance (TT-TG) is a commonly used measurement for surgical decision making in patients with patellofemoral malalignment and instability. This measurement has historically been performed utilizing axial computed tomography (CT). More recently, magnetic resonance imaging (MRI) has been proposed as an equivalent method, but this has not yet been fully validated. Purpose: To determine the reliability of TT-TG distance measurements on both MRI and CT and to determine whether the measurements are interchangeable with one another. Study Design: Cohort study (diagnosis); Level of evidence, 2. Methods: All patients with patellar instability who underwent both CT and MRI of the knee from 2003 to 2011 were included (n = 59 knees in 54 patients). Two fellowship-trained musculoskeletal radiologists measured the TT-TG distances for each patient by CT and MRI in a randomized, blinded fashion. Interobserver reliability was calculated between radiologists for both imaging modalities, and intermethod reliability was calculated between the 2 imaging modalities. The results are reported using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. Results: The 59 knees had a mean TT-TG distance of 16.9 mm (range, 8.3-25.8 mm) by CT and 14.7 mm (range, 1.5-25.1 mm) by MRI. Interobserver reliability between the radiologists was considered excellent for both CT and MRI (ICC = 0.777 and 0.843, respectively). When comparing CT to MRI, the ICC was considered only fair for each of the raters (0.532 and 0.539). Eleven patients (19%) had a TT-TG distance of ≥20 mm on CT preoperatively and underwent distal realignment by tibial tubercle osteotomy. In this surgical subgroup, the mean TT-TG distance was 22.5 mm (range, 19.8-25.8 mm) by CT and only 18.7 mm (range, 14.4-22.8 mm) by MRI for a mean difference of 3.80 mm ( P < .001). Conclusion: The TT-TG distance can be measured with excellent interrater reliability on both MRI and CT; however, the values derived from these 2 tests may not be interchangeable. This observation should be taken into consideration when MRI is used for surgical planning because MRI may underestimate the TT-TG distance when compared with CT.
Outcomes of Repeat Revision Anterior Cruciate Ligament Reconstruction
Griffith, Timothy B. , Allen, B J, Levy, Bruce A. , Dahm, Diane L., Griffith, Timothy Bryan , Stuart, Michael J.

Mayo Clinic

The American Journal of Sports Medicine | April 19, 2013 | Volume: 41 | Issue: 6 | Pages: 1296-1301

10.1177/0363546513482568 | PMID 23605223 Get It

Background: As anterior cruciate ligament (ACL) reconstruction is performed increasingly in the United States, the rate of revision ACL reconstruction continues to rise. A paucity of literature exists with respect to repeat ACL revision surgery. Purpose: To evaluate the functional outcomes of patients who had undergone at least 2 revision ACL reconstructions. Study Design: Case series; Level of evidence, 4. Methods: The records of all patients who had undergone repeat revision ACL reconstructions between 1998 and 2009 were retrospectively reviewed. Data collected included patient demographics, operative findings, pre- and postoperative physical examination findings, radiographs, and Tegner, Lysholm, and International Knee Documentation Committee (IKDC) subjective scores. Results: Fifteen patients had undergone repeat revision ACL reconstruction during the study period. Mean age was 27 years (range, 18-57 years). Mean follow-up was 5 years (range, 2-10 years). At the time of repeat revision surgery, new tunnels were drilled in 9 of 15 (60%) cases. Of those, 8 of 9 (89%) were drilled because femoral tunnels were deemed “too anterior.” During repeat revision, 11 of 15 (73%) patients were noted to have a meniscal tear, and 9 of 15 (67%) had International Cartilage Repair Society (ICRS) grade 3 or 4 chondral lesions. Mean Lysholm score was 60 preoperatively and increased to 82 postoperatively ( P < .001). Mean preoperative IKDC score was 59, which increased to 80 postoperatively ( P < .001). Mean preoperative Tegner score was 6.0. Mean postoperative Tegner score was 4.5, with only 4 of 15 (27%) patients having returned to their prior activity level ( P < .001). Two patients (13%) sustained a traumatic rerupture. Presence of grade 3 or 4 chondral lesions and body mass index greater than 28 at the time of repeat revision were associated with a “fair” or “poor” outcome by Lysholm score ( P = .007 and P = .03, respectively) and IDKC subjective scoring ( P = .04 and P = .007, respectively). Conclusion: Repeat revision ACL reconstruction may improve the functional outcomes of patients who have failed revision ACL reconstruction. Most patients do not return to prior activity level following repeat revision. Presence of grade 3 or 4 chondral lesions and body mass index greater than 28 were associated with worse outcomes.
Treatment of PCL, ACL, and Lateral-Side Knee Injuries: Acute and Chronic
Stuart, Michael, Levy, Bruce A.

Mayo Clinic

Journal of Knee Surgery | September 20, 2012 | Volume: 25 | Issue: 04 | Pages: 295-306

10.1055/s-0032-1324813 | PMID 23150157 Get It

Allograft Versus Autograft in Posterior Cruciate Ligament Reconstruction: An Evidence-Based Systematic Review
Hudgens, Joshua L., Gillette, Blake P., Krych, Aaron J. , May, Jedediah H., Levy, Bruce A. , Stuart, Michael J. , Krych, Aaron J

Mayo Clinic

Journal of Knee Surgery | June 29, 2012 | Volume: 26 | Issue: 02 | Pages: 109-116

10.1055/s-0032-1319778 | PMID 23288765 Get It

Reliability of the dial test using a handheld inclinometer
Levy, Bruce A. , Shah, Jay P. , Hollman, John H. , Dahm, Diane L., Krause, David A. , Stuart, Michael J. , Hollman, John

Mayo Clinic

Knee Surgery, Sports Traumatology, Arthroscopy | January 16, 2012 | Volume: 21 | Issue: 5 | Pages: 1011-1016

10.1007/s00167-011-1873-6 | PMID 22246546 Get It

AbstractPurposeThe primary purpose of this study was to investigate the intra‐tester and inter‐tester reliability of the dial test using a handheld digital inclinometer. Additionally, we examined the responsiveness of the test, and side‐to‐side differences for meaningful comparison.Materials/methodsTwenty‐four healthy subjects (22.5 ± 2.8 years) participated in the study. The dial test was performed on both knees at 30° and 90° of knee flexion with the subject supine. While maintaining a neutral position of the ankle, an inclinometer was positioned parallel to the medial border of the foot to quantify external rotation of the tibia. Two examiners performed the dial test in a blinded manner. The minimal detectable change across repeated measures and side‐to‐side difference was calculated.ResultsIntra‐tester reliability for examiner 1 (E1) was 0.83 at 30° knee flexion and 0.89 at 90° knee flexion. Reliability values for examiner 2 (E2) were 0.86 at 30° and 0.87 at 90° knee flexion. Inter‐tester reliability was 0.74 at 30° and 0.83 at 90°. The minimal detectable change (MDC) for E1 at 30° was ±9.4° and ±7.4° at 90°. For E2, the MDC value was ±9.1° at 30° and ±8.3° at 90°. Ninety‐five percent limits of agreement for side‐to‐side difference was 16.1° and 11.3° ° for E1 at 30° and 90° and for E2 13.9° at 30° and 14.1° at 90°.ConclusionsThis instrumented dial test using a handheld digital inclinometer to measure external rotation can be performed with acceptable reliability in the clinical setting. A difference of 10° between two measurements on the same knee suggests that a meaningful change has occurred. For right to left comparison, differences greater than 15° suggest clinical significance.Level of evidenceIII.
Delta screw versus RetroScrew tibial fixation for ACL reconstruction
Rhee, Peter C. , Dahm, Diane L., Thoreson, Andrew R. , An, Kai‐Nan , Levy, Bruce A. , Stuart, Michael J.

Mayo Clinic

Knee Surgery, Sports Traumatology, Arthroscopy | May 17, 2011 | Volume: 19 | Issue: S1 | Pages: 94-100

10.1007/s00167-011-1543-8 | PMID 22080349 Get It

AbstractPurposeThe purpose of this study is to determine whether the RetroScrew tibial fixation system offers a biomechanical advantage over the Delta screw for anterior cruciate ligament (ACL) reconstruction in cadaveric tibias with low bone mineral density (BMD).MethodsTen matched pairs of osteoporotic cadaveric tibiae underwent simulated ACL reconstruction using quadrupled hamstring grafts with one of the two tibial fixation constructs. Group 1 was fixed with the Delta screw (DS; 35‐mm antegrade biointerference screw), and group 2 was fixed with the RetroScrew system (RSS; 20‐mm retrograde and 17‐mm antegrade biointerference screws). Each construct was cyclically loaded (50–200 N, 1 Hz, 500 cycles) and subsequently loaded to failure (20 mm/s).ResultsAll specimens were osteoporotic without significant segmental (proximal, middle, and distal) BMD differences between groups by quantitative computed tomography (P = n.s.). A trend was noted for more construct failures due to graft slippage in the DS group (n = 3) over the RSS group (n = 1). There were no significant differences in cyclic displacement (P = n.s.), maximum cyclic stiffness (P = n.s.), maximum load at failure (P = n.s.), or pullout stiffness (P = n.s.) between groups.ConclusionsIn an osteoporotic cadaveric model, there was no significant biomechanical advantage of the RetroScrew system versus the Delta screw for tibial fixation in soft tissue graft ACL reconstruction. However, a trend toward lower graft fixation failure to cyclic loading was noted with the RetroScrew system.Level of evidenceBiomechanical comparative study, Level II.
A biomechanical comparison of the Delta screw and RetroScrew tibial fixation on initial intra‐articular graft tension
Rhee, Peter C. , Levy, Bruce A. , Thoreson, Andrew R. , An, Kai-Nan, Dahm, Diane L., Stuart, Michael J. , An, Kai‐Nan

Mayo Clinic

Knee Surgery, Sports Traumatology, Arthroscopy | January 21, 2011 | Volume: 19 | Issue: 5 | Pages: 781-786

10.1007/s00167-010-1366-z | PMID 21258782 Get It

AbstractPurposeThe purpose of this study is to determine the effect of bioabsorbable interference screw (BIS) tibial fixation with the Delta screw (antegrade) and RetroScrew (retrograde) on initial (time zero) intra‐articular graft tension in soft tissue anterior cruciate ligament (ACL) reconstruction in a cadaveric model.MethodsTen matched pairs of cadaveric tibias received one of two tibial fixation constructs using quadrupled hamstring grafts, Delta screw (antegrade) or the RetroScrew (retrograde). Each specimen was mounted to the materials testing device with the displacement force vector in line with the tibial tunnel. The construct was pre‐tensioned (10–30 N, 0.1 Hz, 10 cycles), a baseline tension of 25 N was introduced, and the change in intra‐articular graft tension before and after screw insertion was recorded.ResultsSegmental (proximal, middle, distal) BMD was utilized to assess BMD using quantitative computed tomography (qCT). The Delta screw had a higher maximum insertion torque (P = 0.03) and exhibited a larger increase in intra‐articular graft tension as compared to the RetroScrew (38.3 ± 17.9 N, 7.6 N ± 14.4, P = 0.004), respectively. There were no significant correlations between intra‐articular graft tension increase to maximum insertion torque (P = NS) or corresponding segmental BMD (P = NS).ConclusionsDelta screw tibial fixation (antegrade) in soft tissue ACL reconstruction significantly increases the initial intra‐articular graft tension as compared to RetroScrew screw fixation (retrograde) in this cadaveric model. Delta screw (antegrade) tibial fixation may increase initial quadrupled hamstring graft intra‐articular tension with currently accepted insertion techniques.
Erratum to: Surgical treatment of peroneal nerve palsy after knee dislocation
Giuseffi, Steven A., Shin, Alexander Y. , Dahm, Diane L., Levy, Bruce A. , Bishop, Allen T. , Stuart, Michael J. , Shin, Alexander Y

Mayo Clinic

Knee Surgery, Sports Traumatology, Arthroscopy | September 14, 2010 | Volume: 18 | Issue: 11 | Pages: 1626-1626

10.1007/s00167-010-1261-7 Get It

Medial Patellofemoral Ligament Repair for Recurrent Patellar Dislocation
Camp, Christopher L. , Krych, Aaron J. , Dahm, Diane L., Levy, Bruce A. , Camp, Christopher L. , Stuart, Michael J. , Krych, Aaron J

Mayo Clinic

The American Journal of Sports Medicine | August 17, 2010 | Volume: 38 | Issue: 11 | Pages: 2248-2254

10.1177/0363546510376230 | PMID 20716682 Get It

Background The medial patellofemoral ligament (MPFL) is the primary restraint to extreme lateral displacement and is typically disrupted with an acute lateral patellar dislocation. Patients who fail a comprehensive nonoperative program and experience recurrent lateral patellar instability episodes are candidates for surgical treatment. Current surgical procedures include a variety of proximal realignment techniques, including repair or reconstruction of the MPFL along with distal realignment of the tibial tubercle when indicated. Purpose The objective of this study was to review the clinical, functional, and radiographic outcomes of isolated MPFL repair for recurrent lateral patellar dislocation. Study Design Case series; Level of evidence, 4. Methods The records of all patients undergoing MPFL repair for recurrent patellar dislocation at the Mayo Clinic from 2001 to 2006 were retrospectively reviewed. Twenty-seven patients (29 knees) with an average age of 19 years (range, 11-32 years) were included in this study. Clinical, functional, and radiographic outcomes were assessed at an average of 4 years after surgery (range, 2-7 years), using recurrent instability as the primary end point. Results The success rate of MPFL repair for preventing recurrent dislocations was 72% (21 of 29 knees). Eight patients (28%) experienced a recurrent lateral patellar dislocation. Five of these patients required a reoperation, including two MPFL reconstructions, 1 tibial tubercle osteotomy with MPFL reconstruction, 1 tibial tubercle osteotomy with revision MPFL repair, and 1 revision MPFL repair. At final follow-up, the mean Lysholm and Kujala scores were 86 (range, 42-100) and 92 (range, 57-105), respectively. Postoperative radiographs revealed a mean patellofemoral congruence angle improvement of 27° (range, 5°-44°). The only statistically significant risk factor for failure was nonanatomical MPFL repair at the medial femoral condyle (P = .004). Conclusion Isolated repair of the MPFL for recurrent patellar instability is associated with a relatively high failure rate, but remains a viable surgical option if surgical technique principles are followed. The clinical success of this operation depends on restoration of the anatomical origin of the MPFL and careful patient selection.