Citations

Clear

3058 citation(s) found for "Cd, Johnson".

Use of Mate-Pair Sequencing (MPseq) to Elucidate a Complex BCR-ABL1 Rearrangement Observed in a Newly Diagnosed Case of Chronic Myeloid Leukemia
Aguirre, Jose Jara, Hoppman, Nicole L., Vasmatzis, George , Smadbeck, James B. , Johnson, Sarah H. , Smoley, Stephanie A., Pitel, Beth A. , Pitel, Beth A , Baughn, Linda B. , Greipp, Patricia T. , Ketterling, Rhett P. , Peterson, Jess F.

Mayo Clinic

American Journal of Clinical Pathology | September 21, 2018 | Volume: 150 | Issue: suppl_1 | Pages: S131-S132

10.1093/ajcp/aqy102.314 Get It

Interspace between Popliteal Artery and posterior Capsule of the Knee (IPACK) Injectate Spread: A Cadaver Study
Niesen, Adam D. , Johnson, Christopher , Stoike, David E., Smith, Hugh M. , Jacob, Adam K. , Amundson, Adam W. , Pawlina, Wojciech, Martin, David P., Harris, David J. , Johnson, Christopher S , Harris, David J.

Mayo Clinic

Journal of Ultrasound in Medicine | September 19, 2018 | Volume: 38 | Issue: 3 | Pages: 741-745

10.1002/jum.14761 | PMID 30232819 Get It

Objectives Local anesthetic injection into the interspace between the popliteal artery and the posterior capsule of the knee (IPACK) has the potential to provide motor‐sparing analgesia to the posterior knee after total knee arthroplasty. The primary objective of this cadaveric study was to evaluate injectate spread to relevant anatomic structures with IPACK injection. Methods After receipt of Institutional Review Board Biospecimen Subcommittee approval, IPACK injection was performed on fresh‐frozen cadavers. The popliteal fossa in each specimen was dissected and examined for injectate spread. Results Ten fresh‐frozen cadaver knees were included in the study. Injectate was observed to spread in the popliteal fossa at a mean ± SD of 6.1 ± 0.7 cm in the medial‐lateral dimension and 10.1 ± 3.2 cm in the proximal‐distal dimension. No injectate was noted to be in contact with the proximal segment of the sciatic nerve, but 3 specimens showed injectate spread to the tibial nerve. In 3 specimens, the injectate showed possible contact with the common peroneal nerve. The middle genicular artery was consistently surrounded by injectate. Conclusions This cadaver study of IPACK injection demonstrated spread throughout the popliteal fossa without proximal sciatic involvement. However, the potential for injectate to spread to the tibial or common peroneal nerve was demonstrated. Consistent surrounding of the middle genicular artery with injectate suggests a potential mechanism of analgesia for the IPACK block, due to the predictable relationship between articular sensory nerves and this artery. Further study is needed to determine the ideal site of IPACK injection.
Population health challenges in primary care: What are the unfinished tasks and who should do them?
North, Frederick , Tulledge‐Scheitel, Sidna M. , Matulis, John C. , Pecina, Jennifer L. , Franqueira, Andrew , Johnson, Sarah S, Chaudhry, Rajeev , Franqueira, Andrew M, Pecina, Jennifer

Mayo Clinic

SAGE Open Medicine | September 18, 2018 | Volume: 6 | Issue: No issue available | Pages: No page available

10.1177/2050312118800209 | PMID 30245819 Get It

Background: There are numerous recommendations from expert sources that help guide primary care providers in cancer screening, infectious disease screening, metabolic screening, monitoring of drug levels, and chronic disease management. Little is known about the potential effort needed for a healthcare system to address these recommendations, or the patient effort needed to complete the recommendations. Methods: For 73 recommended population healthcare items, we examined each of 28,742 patients in a primary care internal medicine practice to determine whether they were up-to-date on recommended screening, immunizations, counseling, and chronic disease management goals. We used a rule-based software tool that queries the medical record for diagnoses, dates, laboratory values, pathology reports, and other information used in creating the individualized recommendations. We counted the number of uncompleted recommendations by age groups and examined the healthcare staff needed to address the recommendations and the potential patient effort needed to complete the recommendations. Results: For the 28,742 patients, there were 127,273 uncompleted recommendations identified for population health management (mean recommendations per patient 4.36, standard deviation of 2.65, range of 0–17 recommendations per patient). The age group with the most incomplete recommendations was age of 50–65 years with 5.5 recommendations per patient. The 18–35 years age group had the fewest incomplete recommendations with 2.6 per patient. Across all age groups, initiation of these recommendations required high-level input (physician, nurse practitioner, or physician’s assistant) in 28%. To completely adhere to recommended services, a 1000-patient cross-section cohort would require a total of 464 procedures and 1956 lab tests. Conclusion: Providers and patients face a daunting number of tasks necessary to meet guideline-generated recommendations. We will need new approaches to address the burgeoning numbers of uncompleted recommendations.
Concise Review: Molecular Cytogenetics and Quality Control: Clinical Guardians for Pluripotent Stem Cells
Rohani, Leili , Johnson, Adiv A. , Naghsh, Pooyan, Rancourt, Derrick E. , Holland, Heidrun , Johnson, Adiv A , Ulrich, Henning

Mayo Clinic

Stem Cells Translational Medicine | September 16, 2018 | Volume: 7 | Issue: 12 | Pages: 867-875

10.1002/sctm.18-0087 | PMID 30218497 Get It

Abstract Now that induced pluripotent stem cell (iPSC)-based transplants have been performed in humans and organizations have begun producing clinical-grade iPSCs, it is imperative that strict quality control standards are agreed upon. This is essential as both ESCs and iPSCs have been shown to accumulate genomic aberrations during long-term culturing. These aberrations can include copy number variations, trisomy, amplifications of chromosomal regions, deletions of chromosomal regions, loss of heterozygosity, and epigenetic abnormalities. Moreover, although the differences between iPSCs and ESCs appear largely negligible when a high enough n number is used for comparison, the reprogramming process can generate further aberrations in iPSCs, including copy number variations and deletions in tumor-suppressor genes. If mutations or epigenetic signatures are present in parental cells, these can also be carried over into iPSCs. To maximize patient safety, we recommend a set of standards to be utilized when preparing iPSCs for clinical use. Reprogramming methods that do not involve genomic integration should be used. Cultured cells should be grown using feeder-free and serum-free systems to avoid animal contamination. Karyotyping, whole-genome sequencing, gene expression analyses, and standard sterility tests should all become routine quality control tests. Analysis of mitochondrial DNA integrity, whole-epigenome analyses, as well as single-cell genome sequencing of large cell populations may also prove beneficial. Furthermore, clinical-grade stem cells need to be produced under accepted regulatory good manufacturing process standards. The creation of haplobanks that provide major histocompatibility complex matching is also recommended to improve allogeneic stem cell engraftment.
FA02.07: BARRIER STRUCTURE AND FUNCTION OF THE NEO-SQUAMOUS EPITHELIUM FOLLOWING SUCCESSFUL BARRETT’S ENDOTHERAPY IS IMPAIRED
Ravindran, Adharsh, Blevins, Christopher H. , Johnson, Michele L., Lansing, Ramona, Katzka, David A. , Iyer, P. K. R., Wang, Kenneth , Iyer, Prasad

Mayo Clinic

Diseases of the Esophagus | September 14, 2018 | Volume: 31 | Issue: Supplement_1 | Pages: 5-5

10.1093/dote/doy089.fa02.07 Get It

Abstract Background The neo-squamous epithelium that replaces columnar epithelium after successful endoscopic ablation of Barrett's esophagus (BE) has not been fully characterized in regard to its structural and functional integrity. Intercellular space is a surrogate marker for epithelial structural integrity and mucosal impedance (MI) is a surrogate for transepithelial resistance and thus epithelial functional integrity. Impairment of the structural and functional integrity may influence recurrence following successful ablation. We aimed to measure the esophageal epithelial intercellular space diameter and MI in the neo-squamous and normal squamous epithelium of patients who underwent successful radiofrequency ablation for dysplastic BE. Methods Forty patients with complete remission of intestinal metaplasia (CRIM) (defined as two negative surveillance endoscopies for intestinal metaplasia) were prospectively recruited. Patients were excluded if they had endoscopic evidence of esophagitis. MI measurements were taken at 1 cm above the GE junction and 2 cm above the prior BE segment (targeting uninvolved squamous epithelium), using a novel through the scope MI probe. Endoscopic biopsies were also taken at these corresponding sites to assess intercellular space diameter using transmission electron microscopy (TEM) using standard techniques. Results 80% of patients were male with a mean age of 69 years. Mean follow since achieving CRIM was 30 months. 39 patients underwent RFA for dysplasia. The mean intercellular space diameter was higher in the neo-squamous epithelium (1.01 μm) when compared to the untreated native squamous epithelium (0.96 μm) [Difference of 0.056 μm, 95% CI of -0.036 to 0.148, P = 0.228]. The mean MI was significantly lower in the neosquamous epithelium (4001.3 Ω) when compared to the untreated native epithelium (5168.1 Ω) [Difference of 1166.7 Ω, 95% CI 418.8 to 1914.6, P = 0.003]. Conclusion Neo-squamous epithelium that replaces BE epithelium following successful endoscopic therapy for BE appears to be functionally and likely structurally deficient with regards to acid reflux barrier function, when compared to native squamous esophageal epithelium. This impairment may be associated with recurrence following successful ablation. Disclosure All authors have declared no conflicts of interest.
Breast Cancer Screening: Women's Attitudes and Beliefs in Light of Updated United States Preventive Services Task Force and American Cancer Society Guidelines
Mehta, Jaya , MacLaughlin, Kathy L. , Millstine, Denise , Wallace, Mark R. , Shah, Amit , Fields, Heather , Ruddy, Barbara E., Bryan, Michael , Patel, Bhavika , Temkit, M’hamed , Buras, Matthew , Golafshar, Michael A. , Kling, Juliana M. , Mehta, Jaya M, Millstine, Denise M, Shah, Amit A, Fields, Heather E, Bryan, Michael J, Patel, Bhavika K , Buras, Matthew R , Golafshar, Michael , Kling, Juliana M , Shah, Amit A , Faubion, Stephanie S.

Mayo Clinic

Journal of Women's Health | September 11, 2018 | Volume: 28 | Issue: 3 | Pages: 302-313

10.1089/jwh.2017.6885 | PMID 30204537 Get It

A Monte‐Carlo‐based and GPU‐accelerated 4D‐dose calculator for a pencil beam scanning proton therapy system
Pepin, M. , Tryggestad, E., Tseung, Hok Seum Wan Chan, Johnson, J. , Herman, Michael , Beltran, Chris , Pepin, Mark D, Tryggestad, Erik, Wan Chan Tseung, Hok Seum, Johnson, Jedediah E, Herman, Michael G., Beltran, Chris J , Pepin, Mark D

Mayo Clinic

Medical Physics | September 11, 2018 | Volume: 45 | Issue: 11 | Pages: 5293-5304

10.1002/mp.13182 | PMID 30203550 Get It

PurposeThe presence of respiratory motion during radiation treatment leads to degradation of the expected dose distribution, both for target coverage and healthy tissue sparing, particularly for techniques like pencil beam scanning proton therapy which have dynamic delivery systems. While tools exist to estimate this degraded four‐dimensional (4D) dose, they typically have one or more deficiencies such as not including the particular effects from a dynamic delivery, using analytical dose calculations, and/or using nonphysical dose‐accumulation methods. This work presents a clinically useful 4D‐dose calculator that addresses each of these shortcomings.MethodsTo quickly compute the 4D dose, the three main tasks of the calculator were run on graphics processing units (GPUs). These tasks were (a) simulating the delivery of the plan using measured delivery parameters to distribute the plan amongst 4DCT phases characterizing the patient breathing, (b) using an in‐house Monte Carlo simulation (MC) dose calculator to determine the dose delivered to each breathing phase, and (c) accumulating the doses from the various breathing phases onto a single phase for evaluation. The accumulation was performed by individually transferring the energy and mass of dose‐grid subvoxels, a technique that models the transfer of dose in a more physically realistic manner. The calculator was run on three test cases, with lung, esophagus, and liver targets, respectively, to assess the various uncertainties in the beam delivery simulation as well as to characterize the dose‐accumulation technique.ResultsFour‐dimensional doses were successfully computed for the three test cases with computation times ranging from 4–6 min on a server with eight NVIDIA Titan X graphics cards; the most time‐consuming component was the MC dose engine. The subvoxel‐based dose‐accumulation technique produced stable 4D‐dose distributions at subvoxel scales of 0.5–1.0 mm without impairing the total computation time. The uncertainties in the beam delivery simulation led to moderate variations of the dose–volume histograms for these cases; the variations were reduced by implementing repainting or phase‐gating motion mitigation techniques in the calculator.ConclusionsA MC‐based and GPU‐accelerated 4D‐dose calculator was developed to estimate the effects of respiratory motion on pencil beam scanning proton therapy treatments. After future validation, the calculator could be used to assess treatment plans and its quick runtime would make it easily usable in a future 4D‐robust optimization system.
Effect of premorbid body mass index on mortality in patients with lung cancer: A systematic review and meta-analysis.
Arora, Nivedita , Singh, Siddharth , Johnson, David H. , Gupta, Arjun , Majumder, Kaustav, Mayo, Helen , Singh, Preet Paul , Halm, Ethan A.

Mayo Clinic

Journal of Clinical Oncology | September 6, 2018 | Volume: 34 | Issue: 15_suppl | Pages: 8523-8523

10.1200/jco.2016.34.15_suppl.8523 Get It