Citations

Clear

3035 citation(s) found for "Ma, Kevin".

014 Prevalence of Ejaculatory Dysfunction Following Rezūm Prostate Ablation
Andrews, Jack R. , Avant, R., Gopalakrishna, A., Ziegelmann, Matthew , Köhler, Tobias , Yang, David Y. , Hebert, Kevin , Gopalakrishna, A., Helo, Sevann

Mayo Clinic

The Journal of Sexual Medicine | March 29, 2019 | Volume: 16 | Issue: Supplement_1 | Pages: S7-S8

10.1016/j.jsxm.2019.01.026 Get It

007 The Impact of Sexual Dysfunction on Relationships
Andrews, Jack R. , Ziegelmann, M., Boswell, Timothy , Trost, Landon , Hebert, Kevin , Yang, David Y. , Boswell, T.

Mayo Clinic

The Journal of Sexual Medicine | March 29, 2019 | Volume: 16 | Issue: Supplement_1 | Pages: S4-S5

10.1016/j.jsxm.2019.01.020 Get It

165 Impact of Penile Traction Therapy on Erectile Dysfunction in a Cohort of Men with Peyronie's Disease
Wymer, Kevin , Köhler, Tobias , Trost, L., Yang, David Y. , Meng, Yifan , Savage, Joshua S.

Mayo Clinic

The Journal of Sexual Medicine | March 29, 2019 | Volume: 16 | Issue: Supplement_1 | Pages: S83-S84

10.1016/j.jsxm.2019.01.174 Get It

035 Should Continuation of Antithrombotics at Time of Inflatable Penile Prosthesis Surgery be Standard of Care?
Ziegelmann, M., Andrews, Jack R. , Wymer, Kevin , Manka, Madeleine, Trost, L., Köhler, Tobias , Hebert, Kevin , Yang, David Y.

Mayo Clinic

The Journal of Sexual Medicine | March 29, 2019 | Volume: 16 | Issue: Supplement_1 | Pages: S17-S17

10.1016/j.jsxm.2019.01.046 Get It

015 Patient Decision-Making and Predictors of Genital Satisfaction Associated with Testicular Prostheses after Radical Orchiectomy: a Questionnaire-Based Study of Men with Germ Cell Tumors of the Testicle
Nichols, Paige , Manka, Madeleine, Harris, Kevin, Haney, Nora M. , Harris, K., Brant, Aaron , Pierorazio, Phillip

Mayo Clinic

The Journal of Sexual Medicine | March 29, 2019 | Volume: 16 | Issue: Supplement_1 | Pages: S8-S8

10.1016/j.jsxm.2019.01.027 Get It

MEDIAL AND LATERAL POSTERIOR TIBIAL SLOPE IN THE SKELETALLY IMMATURE: A HUMAN CADAVERIC STUDY
Anchustegui, Nicolas G., Rustad, Audrey , Shea, Cooper, Troyer, Stockton , Dingel, Aleksei , Ganley, Theodore J. , Shea, Kevin P., Milbrandt, Todd A.

Mayo Clinic

Orthopaedic Journal of Sports Medicine | March 29, 2019 | Volume: 7 | Issue: 3_suppl | Pages: No page available

10.1177/2325967119s00130 Get It

Background: Recent research has identified posterior tibial slope as a risk factor for anterior cruciate ligament (ACL) injury, due to increased forces on the ACL with this tibial anatomy. Biomechanical studies suggest that altering a patient’s posterior tibial slope may lower the risk of ACL injury. Due to the presence of an open physis, guided growth may be used to reduce the posterior tibia slope in this high risk skeletally immature population. The primary purpose of this study was to quantify and measure the posterior tibial slope in pediatric knees. Methods: Forty-four pediatric knee CT scans were analyzed using OsiriX, an imaging software. Specimens analyzed were between the ages of 2 and 12 years of age. The proximal tibial slope for each specimen was measured on CT scan sagittal slices at 2 locations: 1) At the medial tibial plateau at the mid region of the medial femoral condyle, as determined on a coronal slice through the femoral condyle; 2) At the lateral tibial plateau at the mid region of the lateral femoral condyle, as determined on the coronal slice through the femoral condyle. The measurement of the posterior tibial slope was determined by placing two lines parallel to the diaphysis of the tibia, one located in the middle of the diaphysis and one located at the most posterior aspect of the diaphysis. The most proximal aspect of both the medial and lateral tibial plateau were then identified and angle measurements were taken in reference to the parallel lines. The angle measurements were plotted graphically by age in order to account for variability in development within age groups. The anterior medial and lateral tibia plateau widths were measured by identifying the mid region of the respective plateaus. From this point, the distance between the top of the tibial plate and the physis was measured. Results: The average posterior tibial slope angle for the medial and lateral tibial plateau were (5.53° ± 4.17°) and (5.95° ± 3.96°) respectively. Independent samples t-test and ANOVA indicate the difference between the posterior tibial slope angle of the medial and lateral tibial plateau were not statistically significant (p < 0.05). When plotted graphically by age, a slight negative trend between age and posterior tibial slope was identified. As age increases, the medial and lateral posterior tibial slope decreases. The mean anterior medial tibial plateau width and lateral tibial plateau width were .99 cm and 1.19 cm respectively. Discussion/Conclusion: ACL primary and secondary injury occur at very high rates in the skeletally immature, especially in females at age 11 and older, and in males at age 13 and older. This data set offers some preliminary values for posterior tibial slope in patients without a history of ACL injury, allowing for comparisons to patients with ACL Injury. Increased tibial slope is a risk factor for ACL injury. In the skeletally immature, one option to alter the tibial slope is the use of guided growth with implants to slow the anterior growth of the proximal tibia, reducing the posterior slope of the tibia, and possibly lower the risk of ACL injury in this high-risk population. [Figure: see text][Figure: see text][Figure: see text][Figure: see text][Figure: see text][Table: see text][Table: see text]
MPFL SURGICAL SIMULATION WITH FEMORAL DRILL HOLE ALLOWING FOR ADJUSTABLE GRAFT TENSION
Shea, Cooper, Rustad, Audrey , Anchustegui, Nicolas G., Troyer, Stockton , Dingel, Aleksei , Ganley, Theodore J. , Milbrandt, Todd A. , Shea, Kevin G.

Mayo Clinic

Orthopaedic Journal of Sports Medicine | March 29, 2019 | Volume: 7 | Issue: 3_suppl | Pages: No page available

10.1177/2325967119s00044 Get It

Background: In skeletally immature patients, the MPFL femoral origin as near or below the physis in most age groups. Although MPFL reconstruction procedures that employ patella drill holes facilitate graft tension adjustment, recent research demonstrates significant risk of patella fractures if patella drill holes are utilized. For this reason, the use of patella drill holes may be best avoided, but this technical alteration makes graft tension fixation more challenging during MPFL reconstruction in the skeletally immature. The purpose of this study was to evaluate the feasibility of developing a physeal respecting femoral drill for the MPFL origin with surgical model simulation, which allows for graft tensioning during MPFL reconstruction. Methods: Pediatric cadaveric specimens (n=5) were dissected by a group of fellowship trained pediatric and/or sports orthopaedic surgeons, and these specimens were then subject to CT Scans for the creation of 3D models. Specimens, aged 7, 9, 10, 11 and 11 years, were used to develop surgical simulations. CT Scans were loaded into Osyrix, converted to appropriate file structure, and then 3D models were loaded into Blender (Stichting Blender Foundation, Buikslotermeerplein 161, 1025 ETAmsterdam, the Netherlands). These models were used to evaluate 3D models of the knee, with placement of medial femoral condyle drill holes starting at the MPFL femoral origin, and entering the joint just anterior to the PCL femoral origin. The anatomic goals of the surgical simulation include: 1. Place drill hole at the MPFL origin on the femur. 2 Enter the intercondylar notch region of the femur anterior to the PCL origin allowing for arthroscopic visualization. 3. avoiding the articular cartilage on the medial femoral condyle. 4. Avoid the femoral physis throughout the course of drilling from the femoral MPFL Origin point to the entry location into the intercondylar notch. In the specimens, a full length drill hole was placed with either a 4 or 5 mm drill hole. Results: All specimens were subject to the surgical modeling and simulated drill hole placement. In each case, a drill hole was successfully placed meeting all the goals of the simulation: 1. Starting Point at MPFL, 2. Exit point anterior the PCL origin, 3. Exit point posterior to the articular cartilage, and 4. Avoidance of direct physeal injury. Figures 1 and 2. Conclusion: Setting graft tension during MPFL reconstruction is one of the significant technical challenges during MPFL reconstruction, and appropriate graft position and tension may be the most critical elements of successful MPFL reconstruction. Historically, graft tension has been set on the patella, using drill holes for the MPFL attachment point on the patella, but this technique has been associated with patella fractures. In order to allow for adjustment of graft tension on the femoral side of the MPFL graft during surgical reconstruction, a surgical simulation was developed to confirm the anatomic appropriateness and safety of placement of femoral drill holes which allow for adjustment of graft tension. This surgical simulation model confirms that MPFL femoral origin anatomy can be reproduced with injury to the physis, the PCL, or the articular cartilage of the femoral condyle. This drill hole and graft can be visualized arthroscopically and allow for appropriate graft tensioning during the procedure. [Figure: see text][Figure: see text]
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, Martin , Andronesi, Ovidiu C. , Barker, Peter B. , Bartha, Robert , Bizzi, Alberto , Bolan, Patrick J. , Cudalbu, Cristina , Dydak, Ulrike , Emir, Uzay E. , González, R. Gilberto , Gruber, Stephan , Gupta, Rakesh K. , Henning, A , Hetherington, Hoby P. , Hüppi, Petra S. , Hurd, Ralph E. , Kantarci, Kejal , Kauppinen, Risto A. , Klomp, Dennis W. J. , Kreis, Roland , Kruiskamp, Marijn J., Leach, Martin O. , Lin, Alexander , Luijten, Peter R. , Marjańska, Małgorzata , Meyerhoff, Dieter J. , Mountford, Carolyn E. , Mullins, Paul G. , Murdoch, James B. , Nelson, Sarah J. , Noeske, Ralph , Öz, Gülin , Pan, Julie W., Poptani, Harish , Posse, Stefan , Ratai, Eva‐Maria , Salibi, Nouha , Scheenen, Tom W. J. , Soher, Brian J. , Tkáč, Ivan , Vigneron, Daniel B. , Howe, Franklyn A. , Choi, In‐Young , Kreis, Roland , Maudsley, Andrew A , Howe, Franklyn A , Öz, Gülin , Marjańska, Małgorzata , Kantarci, Kejal , Brindle, Kevin Michael , Choi, In‐Young, Gruetter, Rolf , Heerschap, Arend , Peet, Andrew C. , Smith, Ian C. P.

Mayo Clinic

Magnetic Resonance in Medicine | March 28, 2019 | Volume: 82 | Issue: 2 | Pages: 527-550

10.1002/mrm.27742 | PMID 30919510 Get It

Proton MRS (1H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research support. Widespread adoption has been slow for several reasons, and technical challenges toward obtaining reliable good‐quality results have been identified as a contributing factor. Considerable progress has been made by the research community to address many of these challenges, and in this paper a consensus is presented on deficiencies in widely available MRS methodology and validated improvements that are currently in routine use at several clinical research institutions. In particular, the localization error for the PRESS localization sequence was found to be unacceptably high at 3 T, and use of the semi‐adiabatic localization by adiabatic selective refocusing sequence is a recommended solution. Incorporation of simulated metabolite basis sets into analysis routines is recommended for reliably capturing the full spectral detail available from short TE acquisitions. In addition, the importance of achieving a highly homogenous static magnetic field (B0) in the acquisition region is emphasized, and the limitations of current methods and hardware are discussed. Most recommendations require only software improvements, greatly enhancing the capabilities of clinical MRS on existing hardware. Implementation of these recommendations should strengthen current clinical applications and advance progress toward developing and validating new MRS biomarkers for clinical use.
Targeting FER Kinase Inhibits Melanoma Growth and Metastasis
Ivanova, Iordanka A. , Arulanantham, Shinthujah, Barr, Kevin , Cepeda, Mario , Parkins, Katie M. , Hamilton, Amanda M. , Johnston, Danielle , Peñuela, Silvia , Hess, David A. , Ronald, John A. , Dagnino, Lina

Mayo Clinic

Cancers | March 27, 2019 | Volume: 11 | Issue: 3 | Pages: 419

10.3390/cancers11030419 | PMID 30909648 Get It

Melanoma is one of the most aggressive types of tumors and exhibits high metastatic potential. Fes-related (FER) kinase is a non-receptor tyrosine kinase that has been implicated in growth and metastasis of various epithelial tumors. In this study, we have examined the role that FER kinase plays in melanoma at the molecular level. FER-depleted melanoma cells exhibit impaired Wnt/β-catenin pathway activity, as well as multiple proteomic changes, which include decreased abundance of L1-cell adhesion molecule (L1-CAM). Consistent with the pro-metastatic functions of these pathways, we demonstrate that depletion of FER kinase decreases melanoma growth and formation of distant metastases in a xenograft model. These findings indicate that FER is an important positive regulator of melanoma metastasis and a potential target for innovative therapies.