Factors associated with severe neurological sequelae of COVID-19: findings from the multicenter COVID-BRAIN imaging cohort

Frontiers in Human Neuroscience | March 19, 2026 | Volume: 20 | Issue: No issue available | Pages: No page available

10.3389/fnhum.2026.1754342 | PMID 41939224

Introduction Neurological post-acute sequelae of COVID-19 (neuroPASC) are associated with persistent cognitive dysfunction and quality-of-life decline. We aimed to identify clinical, behavioral and sociodemographic factors associated with neuroPASC symptom burden two years after COVID-19 among individuals without prior neurological disease. Methods In this prospective, observational study, individuals with neuroPASC ( n = 102) and controls without symptomatic COVID-19 ( n = 74), all without prior neurological, psychiatric, or post-viral conditions, were enrolled between February 2022 and June 2024 across five academic sites. An unsupervised algorithm identified clusters with differing self-reported neurological symptom burden within the neuroPASC group. Functional differences between clusters were evaluated using quality-of-life, neurological and cognitive evaluations. Demographics, behavioral history, comorbidities, and blood biomarkers were compared across clusters and controls. Multivariable logistic regression assessed predictors of neuroPASC severity, including demographics, body-mass-index, Charlson Comorbidity Index, Framingham Risk Score, pre-existing endocrine/metabolic and/or gastrointestinal/hepatobiliary conditions, COVID-19 vaccination prior to infection, hospitalization during acute infection, and cumulative alcohol use. Results Two clusters emerged based on neurological symptom burden, labeled “high-burden” and “low-burden” neuroPASC, reflecting differences in the number and frequency of symptoms. Both clusters had deficits in quality-of-life and cognitive function compared to controls, with greater impairment in high-burden than low-burden neuroPASC. The clusters did not differ by sex, education, tobacco and cannabis use, blood pressure, body-mass-index, HbA1C, days since infection, hospitalization during COVID-19, pre-COVID vaccination rate, antibody-positivity, inflammation, and neurodegeneration biomarkers. The high-burden cluster was older and exhibited higher comorbidity burden and greater cumulative alcohol use compared with the low-burden cluster and controls. Pre-existing endocrine/metabolic and gastrointestinal/hepatobiliary conditions were more common in high-burden (63%) than in low-burden neuroPASC (35%). After adjusting for clinical and demographic factors, these pre-existing conditions remained the only independent predictor of severity, conferring a 3.5-fold increase in the odds of high-burden versus low-burden neuroPASC. Discussion Older age, higher comorbidity burden, greater cumulative alcohol use, and endocrine/metabolic and gastrointestinal conditions, rather than acute COVID-19 severity, were observed in the high-burden neuroPASC cluster. After multivariable adjustment, only pre-existing endocrine/metabolic and/or gastrointestinal/hepatobiliary conditions remained independently associated with high-burden neuroPASC, conferring a 3.5-fold increase in odds and highlighting the need for targeted post-infection monitoring in at-risk patients.
Across‐vendor standardization of semi‐LASER for single‐voxel MRS at 3T

NMR in Biomedicine | December 19, 2019 | Volume: 34 | Issue: 5 | Pages: No page available

10.1002/nbm.4218 | PMID 31854045

Abstract The semi‐adiabatic localization by adiabatic selective refocusing (sLASER) sequence provides single‐shot full intensity signal with clean localization and minimal chemical shift displacement error and was recommended by the international MRS Consensus Group as the preferred localization sequence at high‐ and ultra‐high fields. Across‐vendor standardization of the sLASER sequence at 3 tesla has been challenging due to the B 1 requirements of the adiabatic inversion pulses and maximum B 1 limitations on some platforms. The aims of this study were to design a short‐echo sLASER sequence that can be executed within a B 1 limit of 15 μT by taking advantage of gradient‐modulated RF pulses, to implement it on three major platforms and to evaluate the between‐vendor reproducibility of its perfomance with phantoms and in vivo. In addition, voxel‐based first and second order B 0 shimming and voxel‐based B 1 adjustments of RF pulses were implemented on all platforms. Amongst the gradient‐modulated pulses considered (GOIA, FOCI and BASSI), GOIA‐WURST was identified as the optimal refocusing pulse that provides good voxel selection within a maximum B 1 of 15 μT based on localization efficiency, contamination error and ripple artifacts of the inversion profile. An sLASER sequence (30 ms echo time) that incorporates VAPOR water suppression and 3D outer volume suppression was implemented with identical parameters (RF pulse type and duration, spoiler gradients and inter‐pulse delays) on GE, Philips and Siemens and generated identical spectra on the GE ‘Braino’ phantom between vendors. High‐quality spectra were consistently obtained in multiple regions (cerebellar white matter, hippocampus, pons, posterior cingulate cortex and putamen) in the human brain across vendors (5 subjects scanned per vendor per region; mean signal‐to‐noise ratio > 33; mean water linewidth between 6.5 Hz to 11.4 Hz). The harmonized sLASER protocol is expected to produce high reproducibility of MRS across sites thereby allowing large multi‐site studies with clinical cohorts.
Methodological consensus on clinical proton MRS of the brain: Review and recommendations

Magnetic Resonance in Medicine | March 28, 2019 | Volume: 82 | Issue: 2 | Pages: 527-550

10.1002/mrm.27742 | PMID 30919510

Proton MRS (1H MRS) provides noninvasive, quantitative metabolite profiles of tissue and has been shown to aid the clinical management of several brain diseases. Although most modern clinical MR scanners support MRS capabilities, routine use is largely restricted to specialized centers with good access to MR research support. Widespread adoption has been slow for several reasons, and technical challenges toward obtaining reliable good‐quality results have been identified as a contributing factor. Considerable progress has been made by the research community to address many of these challenges, and in this paper a consensus is presented on deficiencies in widely available MRS methodology and validated improvements that are currently in routine use at several clinical research institutions. In particular, the localization error for the PRESS localization sequence was found to be unacceptably high at 3 T, and use of the semi‐adiabatic localization by adiabatic selective refocusing sequence is a recommended solution. Incorporation of simulated metabolite basis sets into analysis routines is recommended for reliably capturing the full spectral detail available from short TE acquisitions. In addition, the importance of achieving a highly homogenous static magnetic field (B0) in the acquisition region is emphasized, and the limitations of current methods and hardware are discussed. Most recommendations require only software improvements, greatly enhancing the capabilities of clinical MRS on existing hardware. Implementation of these recommendations should strengthen current clinical applications and advance progress toward developing and validating new MRS biomarkers for clinical use.
AutoVOI: real‐time automatic prescription of volume‐of‐interest for single voxel spectroscopy

Magnetic Resonance in Medicine | April 6, 2018 | Volume: 80 | Issue: 5 | Pages: 1787-1798

10.1002/mrm.27203 | PMID 29624727

PurposeTo develop a fast and automated volume‐of‐interest (VOI) prescription pipeline (AutoVOI) for single‐voxel MRS that removes the need for manual VOI placement, allows flexible VOI planning in any brain region, and enables high inter‐ and intra‐subject consistency of VOI prescription.MethodsAutoVOI was designed to transfer pre‐defined VOIs from an atlas to the 3D anatomical data of the subject during the scan. The AutoVOI pipeline was optimized for consistency in VOI placement (precision), enhanced coverage of the targeted tissue (accuracy), and fast computation speed. The tool was evaluated against manual VOI placement using existing T1‐weighted data sets and corresponding VOI prescriptions. Finally, it was implemented on 2 scanner platforms to acquire MRS data from clinically relevant VOIs that span the cerebrum, cerebellum, and the brainstem.ResultsThe AutoVOI pipeline includes skull stripping, non‐linear registration of the atlas to the subject's brain, and computation of the VOI coordinates and angulations using a minimum oriented bounding box algorithm. When compared against manual prescription, AutoVOI showed higher intra‐ and inter‐subject spatial consistency, as quantified by generalized Dice coefficients (GDC), lower intra‐ and inter‐subject variability in tissue composition (gray matter, white matter, and cerebrospinal fluid) and higher or equal accuracy, as quantified by GDC of prescribed VOI with targeted tissues. High quality spectra were obtained on Siemens and Philips 3T systems from 6 automatically prescribed VOIs by the tool.ConclusionRobust automatic VOI prescription is feasible and can help facilitate clinical adoption of MRS by avoiding operator dependence of manual selection.