Citations

Clear

270 citation(s) found for "Robertson, R".

Genetic and Epigenetic Heterogeneity in Normal Liver Homeostasis and Its Implications for Liver Disease and Hepatocellular Cancer
Hlady, Ryan A. , Robertson, Keith D. , Robertson, Keith D

Mayo Clinic

Seminars in Liver Disease | February 22, 2018 | Volume: 38 | Issue: 01 | Pages: 041-050

10.1055/s-0037-1621712 | PMID 29471564 Get It

AbstractHepatocellular carcinoma (HCC) is the most prevalent primary tumor of the liver, and is steadily becoming one of the most lethal cancers worldwide. Liver resection, which is the recommended procedure for early localized HCC, results in frequent recurrence (50–70%), while the standard of care for late-stage HCC, multikinase inhibitors, only improves survival by a few months. The lack of success for these treatment modalities is attributable, at least in part, to marked phenotypic heterogeneity within the tumor. Intratumoral heterogeneity (ITH) has emerged as a defining characteristic of human tumors, with individual cancer cells displaying distinct differences in properties including growth rate, metastatic capacity, and response to treatment. This heterogeneity, which is unlikely to be captured from a biopsy, impacts outcome because a single treatment targeting one cancer-specific pathway would spare tumor cells having distinct characteristics. Development of effective biomarkers remains a major challenge for similar reasons. Understanding, interpreting, and circumventing the impact of ITH is therefore paramount for developing reliable biomarkers and designing effective individualized treatment strategies for HCC.
Orthostatic heart rate changes in patients with autonomic failure caused by neurodegenerative synucleinopathies
Norcliffe‐Kaufmann, Lucy , Kaufmann, Horacio , Palma, Jose‐Alberto , Shibao, Cyndya A. , Low, Phillip A. , Robertson, David, Kaufmann, Horacio , Palma, Jose-Alberto , Shibao, Cyndya A , Biaggioni, Italo , Peltier, Amanda , Singer, Wolfgang , Goldstein, David S. , Gibbons, Christopher H. , Freeman, Roy L.

Mayo Clinic

Annals of Neurology | February 5, 2018 | Volume: 83 | Issue: 3 | Pages: 522-531

10.1002/ana.25170 | PMID 29405350 Get It

Objective Blunted tachycardia during hypotension is a characteristic feature of patients with autonomic failure, but the range has not been defined. This study reports the range of orthostatic heart rate (HR) changes in patients with autonomic failure caused by neurodegenerative synucleinopathies. Methods Patients evaluated at sites of the U.S. Autonomic Consortium (NCT01799915) underwent standardized autonomic function tests and full neurological evaluation. Results We identified 402 patients with orthostatic hypotension (OH) who had normal sinus rhythm. Of these, 378 had impaired sympathetic activation (ie, neurogenic OH) and based on their neurological examination were diagnosed with Parkinson disease, dementia with Lewy bodies, pure autonomic failure, or multiple system atrophy. The remaining 24 patients had preserved sympathetic activation and their OH was classified as nonneurogenic, due to volume depletion, anemia, or polypharmacy. Patients with neurogenic OH had twice the fall in systolic blood pressure (SBP; −44 ± 25 vs −21 ± 14 mmHg [mean ± standard deviation], p < 0.0001) but only one‐third of the increase in HR of those with nonneurogenic OH (8 ± 8 vs 25 ± 11 beats per minute [bpm], p < 0.0001). A ΔHR/ΔSBP ratio of 0.492 bpm/mmHg had excellent sensitivity (91.3%) and specificity (88.4%) to distinguish between patients with neurogenic from nonneurogenic OH (area under the curve = 0.96, p < 0.0001). Within patients with neurogenic OH, HR increased more in those with multiple system atrophy ( p = 0.0003), but there was considerable overlap with patients with Lewy body disorders. Interpretation A blunted HR increase during hypotension suggests a neurogenic cause. A ΔHR/ΔSBP ratio < 0.5 bpm/mmHg is diagnostic of neurogenic OH. Ann Neurol 2018;83:522–531
Technical Note: An efficient daily QA procedure for proton pencil beam scanning
Younkin, James E. , Shen, Jiajian , Robertson, Daniel , Mundy, Daniel W. , Clouser, Edward , Ding, Xiaoning, Stoker, Joshua B., Bues, Martin , Robertson, Daniel G, Shen, Jiajian , Liu, Wei , Clouser, Edward Lee

Mayo Clinic

Medical Physics | February 2, 2018 | Volume: 45 | Issue: 3 | Pages: 1040-1049

10.1002/mp.12787 | PMID 29394447 Get It

PurposeThe aim of this work was to develop an efficient daily quality assurance (QA) program with strict tolerance levels for pencil beam scanning (PBS) proton radiotherapy featuring simultaneous dosimetric testing on a single, nonuniform field.MethodsA nonuniform field measuring beam output, proton range, and spot position was designed for delivery onto a Sun Nuclear Daily‐QA 3 device. A custom acrylic block permitted simultaneous measurement of low‐ and high‐energy proton ranges in addition to beam output. Sensitivities to output, range, and spot position were evaluated to quantitate the device's response. Reproducibility tests were used to identify and control sources of measurement error as well as to assess the QA procedure's robustness. This procedure was implemented in each of our four treatment rooms independently; 4–6 months of daily QA measurements were collected.ResultsThe 1% output, 0.5 mm range, and 1.5 mm spot position tolerances derived from preliminary tests were tighter overall than tolerances found in the literature and equivalent to the limits used for proton system commissioning. The simplicity and automation of the procedure reduced the time required for daily QA to 10 min per treatment room, and competition for beam between multiple treatment rooms was minimized.ConclusionsAn efficient daily PBS QA procedure can be performed using a single, nonuniform field on a nondedicated QA device. A thorough quantitation of the device's response and careful control of measurement uncertainties allowed daily tolerances to match commissioning standards.
Deficient Glucagon Response to Hypoglycemia During a Mixed Meal in Total Pancreatectomy/Islet Autotransplantation Recipients
Bogachus, Lindsey D., Robertson, R. Paul , Bellin, Melena D. , Vella, Adrian

Mayo Clinic

The Journal of Clinical Endocrinology & Metabolism | January 17, 2018 | Volume: 103 | Issue: 4 | Pages: 1522-1529

10.1210/jc.2017-02182 | PMID 29351616 Get It

Recommendations of the Global Multiple System Atrophy Research Roadmap Meeting
Walsh, Ryan R., Krismer, Florian , Galpern, Wendy R., Wenning, Gregor K. , Low, Phillip A. , Halliday, Glenda M. , Holton, Janice L. , Quinn, Niall , Rascol, Olivier , Shaw, Leslie M. , Eidelberg, David , Bower, Pam, Abler, Victor, Biedenharn, Judy, Bitan, Gal , Brundin, Patrik , Fernandez, Hubert, Fortier, Philip, Gasser, Thomas , Hewitt, Alice, Höglinger, Günter U. , Huentelman, Matt , Jensen, Poul Henning , Jeromin, Andreas, Kang, Un Jung , Kaufmann, Horacio , Kellerman, Lawrence R., Khurana, Vikram , Klockgether, Thomas , Kim, Woojin S. , Langer, Carol B., Masliah, Eliezer , Meissner, Wassilios G. , Ostrowitzki, Susanne, Piantadosi, Steven , Roemer, Cyndi, Schenk, Dale, Schlossmacher, Michael G. , Seppi, Klaus , Shih, Lily, Siderowf, Andrew , Stebbins, Glenn T. , Stefanova, Nadia , Sutton, Sharon Egretta, Zhang, Jing , Halliday, Glenda , Koroshetz, Walter J. , Holton, Janice, Quinn, Niall P, Brooks, David J. , Hewitt, Art, Huentelman, Matt J, Jensen, Poul H, Kellerman, Lawrence, Kim, Woojin Scott, Langer, Carol, LeWitt, Peter, Meissner, Wassilios, Melki, Ronald, Poewe, Werner, Schlossmacher, Michael, Schmahmann, Jeremy D, Tsuji, Shoji , Sutton, Sharon, Kaufmann, Horacio , Meissner, Wassilios G , Höglinger, Günter U , Krismer, Florian , Seppi, Klaus , Cummings, Jeffrey L. , Fortier, P, Freeman, Roy L. , LeWitt, Peter A. , Melki, Ronald , Poewe, Werner H , Robertson, David L. , Schmahmann, Jeremy Dan , Sutton, Sharon

Mayo Clinic

Neurology | December 13, 2017 | Volume: 90 | Issue: 2 | Pages: 74-82

10.1212/wnl.0000000000004798 | PMID 29237794 Get It

Powassan virus postencephalitic parkinsonism
Mittal, Shivam Om , Hassan, Anhar , Sanchez, Joyce L. , Robertson, Carrie E. , Sanchez, Joyce, Robertson, Carrie E , Mittal, Shivam Om

Mayo Clinic

Neurology Clinical Practice | December 11, 2017 | Volume: 7 | Issue: 6 | Pages: 527-530

10.1212/cpj.0000000000000391 | PMID 29431163 Get It

A data-driven approach for addressing the lack of flow waveform data in studies of cerebral arterial flow in older adults*
Durka, Michael J. , Wong, Isaac H, Kallmes, David F. , Pasalic, Dario , Mut, Fernando , Jagani, Manoj, Blanco, Pablo J. , Robertson, Anne M. , Robertson, Anne M , Cebral, Juan R.

Mayo Clinic

Physiological Measurement | December 5, 2017 | Volume: 39 | Issue: 1 | Pages: 015006

10.1088/1361-6579/aa9f46 | PMID 29205172 Get It

Abstract Objective : Blood flow waveforms—essential data for hemodynamic modeling—are often in practice unavailable to researchers. The objectives of this work were to assess the variability among the waveforms for a clinically relevant older population, and develop data-based methods for addressing the missing waveform data for hemodynamic studies. Approach : We analyzed 272 flow waveforms from the internal carotid arteries of older patients (73 ± 13 yr) with moderate cardiovascular disease, and used these data to develop methods to guide new approaches for hemodynamic studies. Main results : Profound variations in waveform parameters were found within the aged population that were not seen in published data for young subjects. Common features in the aged population relative to the young included a larger systole-to-diastole flow rate ratio, increased flow during late systole, and absence of a dicrotic notch. Eight waveforms were identified that collectively represent the range of waveforms in the older population. A relationship between waveform shape and flow rate was obtained that, in conjunction with equations relating flow rate to diameter, can be used to provide individualized waveforms for patient-specific geometries. The dependence of flow rate on diameter was statistically different between male and female patients. Significance : It was shown that a single archetypal waveform cannot well-represent the diverse waveforms found within an aged population, although this approach is frequently used in studies of flow in the cerebral vasculature. Motivated by these results, we provided a set of eight waveforms that can be used to assess the hemodynamic uncertainty associated with the lack of patient-specific waveform data. We also provided a methodology for generating individualized waveforms when patient gender, age, and cardiovascular disease state are known. These data-driven approaches can be used to devise more relevant in vitro or in silico intra-cranial hemodynamic studies for older patients.
A novel and fast method for proton range verification using a step wedge and 2D scintillator
Shen, Jiajian , Allred, Bryce C., Robertson, Daniel , Remmes, Nicholas B. , Keole, Sameer R., Bues, Martin , Robertson, Daniel G, Liu, Wei , Sio, Terence T. , Shen, Jiajian , Bues, Martin

Mayo Clinic

Medical Physics | June 30, 2017 | Volume: 44 | Issue: 9 | Pages: 4409-4414

10.1002/mp.12439 | PMID 28665529 Get It

PurposeTo implement and evaluate a novel and fast method for proton range verification by using a planar scintillator and step wedge.MethodsA homogenous proton pencil beam plan with 35 energies was designed and delivered to a 2D flat scintillator with a step wedge. The measurement was repeated 15 times (3 different days, 5 times per day). The scintillator image was smoothed, the Bragg peak and distal fall off regions were fitted by an analytical equation, and the proton range was calculated using simple trigonometry. The accuracy of this method was verified by comparing the measured ranges to those obtained using an ionization chamber and a scanning water tank, the gold standard. The reproducibility was evaluated by comparing the ranges over 15 repeated measurements. The sensitivity was evaluated by delivering to same beam to the system with a film inserted under the wedge.ResultsThe range accuracy of all 35 proton energies measured over 3 days was within 0.2 mm. The reproducibility in 15 repeated measurements for all 35 proton ranges was ±0.045 mm. The sensitivity to range variation is 0.1 mm for the worst case. This efficient procedure permits measurement of 35 proton ranges in less than 3 min. The automated data processing produces results immediately. The setup of this system took less than 5 min. The time saving by this new method is about two orders of magnitude when compared with the time for water tank range measurements.ConclusionsA novel method using a scintillator with a step wedge to measure the proton range was implemented and evaluated. This novel method is fast and sensitive, and the proton range measured by this method was accurate and highly reproducible.
Restless mouth syndrome
Jung, Youngsin, Hassan, Anhar , Louis, Erik K. St. , Robertson, Carrie E. , St Louis, Erik K, St Louis, E K , Robertson, Carrie E

Mayo Clinic

Neurology Clinical Practice | June 12, 2017 | Volume: 7 | Issue: 3 | Pages: No page available

10.1212/cpj.0000000000000280 | PMID 30107007 Get It