Citations

Showing 10 of 107969 citations.

Utility of 3D-Printed Models in the Surgical Planning for Primary Spine Tumors: A Survey of International Spinal Oncology Experts
Mikula, Anthony L. , Rhines, Laurence D. , Patel, Shalin S. , Pennington, Zach , Karim, S. Mohammed, Alvarez‐Breckenridge, Christopher , North, Robert Y. , Rose, Peter S. , Bird, Justin E. , Alvarez-Breckenridge, Christopher , Pennington, Zach , Morris, Jonathan M. , Tappa, Karthik K. , Tatsui, Claudio Esteves , Clarke, Michelle J.

Mayo Clinic

Global Spine Journal | August 21, 2024 | Volume: 15 | Issue: 4 | Pages: 2004-2013

10.1177/21925682241278323 | PMID 39166967 Get It

Study Design Survey study. Objectives The purpose of this study was to characterize the utility of 3D printed patient specific anatomic models for the planning of complex primary spine tumor surgeries. Methods A survey of individual members of an international study group of spinal oncology surgeons was performed. Participants were provided a clinical vignette, pathologic diagnosis, and pre-operative imaging for three primary spinal oncology cases. Study participants provided a free text surgical plan for resection and were then presented an associated 3D printed model for each case and asked to re-evaluate their surgical plan. Results Ten spinal oncology surgeons participated in the study, representing nine institutions across five countries. Four of the surgeons (40%) made significant changes to their surgical plan after reviewing the 3D models, including sacrifice of an additional nerve root to obtain negative margins, sparing an SI joint that was originally planned for inclusion in the en bloc resection, adjusting the location of osteotomy cuts, changes to the number of surgical stages and/or staging order, and preservation of neurology that was originally planned for sacrifice. The overall impression of the 3D models was positive, with 90% of the participants stating they found the 3D model useful in developing a surgical plan. Conclusions Surgical planning for resection of primary spinal column tumors is challenging and time intensive. 3D printed patient specific surgical models may be an additional tool that can augment surgical planning and execution by improving the chance of accomplishing surgical resection goals and minimizing morbidity.
Background Noise Removal in Non-Contrast- Enhanced Ultrasound Microvasculature Imaging Using Combined Collaborative, Morphological, and Vesselness Filtering
Sabeti, Soroosh , Fatemi, Mostafa , Fatemi, Mostafa , Alizad, Azra , Alizad, Azra

Mayo Clinic

IEEE Access | August 20, 2024 | Volume: 12 | Issue: No issue available | Pages: 116150-116161

10.1109/access.2024.3446531 | PMID 40292271 Get It

Shear-Wave Dispersion for Detecting Hepatic Inflammation in Metabolic Dysfunction–associated Steatotic Liver Disease
Yin, Meng , Yin, Meng

Mayo Clinic

Radiology | August 20, 2024 | Volume: 312 | Issue: 2 | Pages: No page available

10.1148/radiol.241420 | PMID 39162631 Get It

Thrombolysis for Ischemic Stroke Despite Recent Ingestion of Direct Oral Anticoagulants – A Growing Dilemma Also in India
Meinel, Thomas R. , Menon, Bijoy K. , Fischer, Urs , Seiffge, David , Paramasivan, Naveen K, Fischer, Urs , Seiffge, David , Paramasivan, Naveen Kumar

Mayo Clinic

Annals of Indian Academy of Neurology | August 20, 2024 | Volume: 27 | Issue: 4 | Pages: 345-351

10.4103/aian.aian_524_24 | PMID 39196805 Get It

The administration of intravenous thrombolysis (IVT) for patients with acute ischemic stroke who have recently ingested direct oral anticoagulants (DOACs) presents a clinical challenge due to the perceived increased risk of intracranial hemorrhage (ICH). Traditional guidelines from the US and European authorities advise against IVT within 48 h of last DOAC ingestion, unless specific coagulation tests indicate safety. However, emerging observational studies suggest that IVT might be safe in selected patients. A US stroke registry study and a global multicenter cohort study both reported no significant increase in symptomatic ICH among patients on DOACs compared to those not on anticoagulants. A systematic review of all published observational studies further supported these findings, showing comparable bleeding rates and functional outcomes in DOAC-treated patients. Reversal agents like idarucizumab for dabigatran have demonstrated potential in facilitating safer IVT administration, though logistical and cost-related barriers limit their widespread use. The variability in global guidelines reflects differing approaches to risk assessment and resource availability, highlighting the need for individualized treatment decisions. In India, the increasing prevalence of atrial fibrillation and stroke as well as prescription of DOACs necessitate adapted guidelines that consider local health-care infrastructure. Despite the promising observational data, the lack of randomized controlled trials underscores the need for further research to establish robust evidence for IVT use in this context. Collaborative international efforts and inclusion of diverse patient populations in future studies will be crucial to refine treatment protocols and improve outcomes for stroke patients on DOACs.
Anatomical Ablation of the Atrioventricular Node
Katritsis, Demosthenes G. , Siontis, Konstantinos C. , Agarwal, Sharad , Stavrakis, Stavros , Giazitzoglou, Eleftherios, Amin, Hina , Tretter, Justin T. , Calkins, Hugh , Marine, Joseph Edward , Sánchez‐Quintana, Damián , Anderson, Robert Henry

Mayo Clinic

Arrhythmia & Electrophysiology Review | August 20, 2024 | Volume: 13 | Issue: No issue available | Pages: No page available

10.15420/aer.2024.13 | PMID 39221060 Get It

Background: Atrioventricular (AV) conduction ablation has been achieved by targeting the area of penetration of the conduction axis as defined by recording a His bundle potential. Ablation of the His bundle may reduce the possibility of a robust junctional escape rhythm. It was hypothesised that specific AV nodal ablation is feasible and safe. Methods: The anatomical position of the AV node in relation to the site of penetration of the conduction axis was identified as described in dissections and histological sections of human hearts. Radiofrequency (RF) ablation was accomplished based on the anatomical criteria. Results: Specific anatomical ablation of the AV node was attempted in 72 patients. Successful AV nodal ablation was accomplished in 63 patients (87.5%), following 60 minutes (IQR 50–70 minutes) of procedure time, 3.4 minutes (IQR 2.4–5.5 minutes) of fluoroscopy time, and delivery of 4 (IQR 3–6) RF lesions. Αn escape rhythm was present in 45 patients (71%), and the QRS complex was similar to that before ablation in all 45 patients. Atropine was administered in six patients after the 10-min waiting period and did not result in restoration of conduction. In nine patients, AV conduction could not be interrupted, and AV block was achieved with ablation of the His after delivery of 12 (IQR 8–15) RF lesions. No cases of sudden death were encountered, and all patients had persistent AV block during a median 10.5 months (IQR 5–14 months) of follow-up. Conclusion: Anatomical ablation of the AV node is feasible and safe, and results in an escape rhythm similar to that before ablation.
Clinical Applications of Cardiac Magnetic Resonance Parametric Mapping
Muser, Daniele , Selvanayagam, Joseph B. , Nucifora, Gaetano , Chahal, Anwar A, Nucifora, Gaetano , Muser, Daniele , Chahal, C. Anwar A.

Mayo Clinic

Diagnostics | August 20, 2024 | Volume: 14 | Issue: 16 | Pages: 1816

10.3390/diagnostics14161816 | PMID 39202304 Get It

Cardiovascular magnetic resonance (CMR) imaging is widely regarded as the gold-standard technique for myocardial tissue characterization, allowing for the detection of structural abnormalities such as myocardial fatty replacement, myocardial edema, myocardial necrosis, and/or fibrosis. Historically, the identification of abnormal myocardial regions relied on variations in tissue signal intensity, often necessitating the use of exogenous contrast agents. However, over the past two decades, innovative parametric mapping techniques have emerged, enabling the direct quantitative assessment of tissue magnetic resonance (MR) properties on a voxel-by-voxel basis. These mapping techniques offer significant advantages by providing comprehensive and precise information that can be translated into color-coded maps, facilitating the identification of subtle or diffuse myocardial abnormalities. As unlikely conventional methods, these techniques do not require a substantial amount of structurally altered tissue to be visually identifiable as an area of abnormal signal intensity, eliminating the reliance on contrast agents. Moreover, these parametric mapping techniques, such as T1, T2, and T2* mapping, have transitioned from being primarily research tools to becoming valuable assets in the clinical diagnosis and risk stratification of various cardiac disorders. In this review, we aim to elucidate the underlying physical principles of CMR parametric mapping, explore its current clinical applications, address potential pitfalls, and outline future directions for research and development in this field.
HOCl-producing electrochemical bandage is active in murine polymicrobial wound infection
Fleming, Derek , Bozyel, Ibrahim , Koscianski, Christina, Ozdemir, Dilara , Karau, Melissa J. , Cuello, Luz , Anoy, Md Monzurul Islam , Gelston, Suzanne , Schuetz, Audrey N. , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Koscianski, Christina A, Beyenal, H , Patel, Robin , Schuetz, Audrey N , Fleming, Derek , Beyenal, Haluk , Patel, Robin

Mayo Clinic

Microbiology Spectrum | August 20, 2024 | Volume: 12 | Issue: 10 | Pages: No page available

10.1128/spectrum.00626-24 | PMID 39162542 Get It

ABSTRACT Wound infections, exacerbated by the prevalence of antibiotic-resistant bacterial pathogens, necessitate innovative antimicrobial approaches. Polymicrobial infections, often involving Pseudomonas aeruginosa and methicillin-resistant Staphylococcus aureus (MRSA), present challenges due to biofilm formation and antibiotic resistance. Hypochlorous acid (HOCl), a potent antimicrobial agent, holds promise as an alternative therapy. An electrochemical bandage (e-bandage) that generates HOCl in situ via precise polarization controlled by a miniaturized potentiostat was evaluated for the treatment of murine wound biofilm infections containing both P. aeruginosa with “difficult-to-treat” resistance and MRSA. Previously, HOCl-producing e-bandage was shown to reduce murine wound biofilms containing P. aeruginosa alone. Here, in 5-mm excisional skin wounds containing 48-h biofilms comprising MRSA and P. aeruginosa combined, polarized e-bandage treatment reduced MRSA by 1.1 log 10 CFU/g ( P = 0.026) vs non-polarized e-bandage treatment (no HOCl production), and 1.4 log 10 CFU/g (0.0015) vs Tegaderm only controls; P. aeruginosa was similarly reduced by 1.6 log 10 CFU/g ( P = 0.0032) and 1.6 log 10 CFU/g ( P = 0.0015), respectively. For wounds infected with MRSA alone, polarized e-bandage treatment reduced bacterial load by 1.1 log 10 CFU/g ( P = 0.0048) and 1.3 log 10 CFU/g ( P = 0.0048) compared with non-polarized e-bandage and Tegaderm only, respectively. The e-bandage treatment did not negatively impact wound healing or cause tissue toxicity. The addition of systemic antibiotics did not enhance the antimicrobial efficacy of e-bandages. This study provides additional evidence for the HOCl-producing e-bandage as a novel antimicrobial strategy for managing wound infections, including in the context of antibiotic resistance and polymicrobial infections. IMPORTANCE New approaches are needed to combat the rise of antimicrobial-resistant infections. The HOCl-producing electrochemical bandage (e-bandage) leverages in situ generation of HOCl, a natural biocide, for broad-spectrum killing of wound pathogens. Unlike traditional therapies that may exhibit limited activity against biofilms and antimicrobial-resistant organisms, the e-bandage offers a potent, standalone solution that does not contribute to further resistance or require adjunctive antibiotic therapy. Here, we show the ability of the e-bandage to address polymicrobial infection by antimicrobial resistant clinical isolates of Staphylococcus aureus and Pseudomonas aeruginosa , two commonly isolated, co-infecting wound pathogens. Effectiveness of the HOCl-producing e-bandage in reducing pathogen load while minimizing tissue toxicity and avoiding the need for systemic antibiotics underscores its potential as a tool in managing complex wound infections.
Exploring Symptom Management Experiences Among College Students With Type 1 Diabetes Mellitus Using a Theoretical Framework: A Qualitative Study
McFadden, Ny’Nika T. , Chaney, Beth H. , Jaiswal, Jessica , Lovett, Kylie , Carmack, Heather J. , Wilkerson, Amanda H. , Stellefson, Michael

Mayo Clinic

The Science of Diabetes Self-Management and Care | August 20, 2024 | Volume: 50 | Issue: 5 | Pages: 339-351

10.1177/26350106241268412 | PMID 39162332 Get It

Purpose The purpose of this study was to explore symptom management experiences among college students with type 1 diabetes mellitus (T1DM). Limited qualitative data using a theoretical framework exist that explore the self-care behavior processes for symptom management. Methods A qualitative approach was used for this study. The middle-range theory of self care of chronic illness served as a framework for data collection and analysis procedures. Data collection included distributing a survey to collect participants’ demographic and sociodemographic data and utilizing a semi-structured interview guide to conduct one-on-one interviews with 31 participants. Interviews occurred via Zoom (n = 28) and in person (n = 3). Interview transcripts were uploaded in NVivo for data management. The research team created a codebook using theoretical constructs to assist with thematic analysis. Data are representative of a sample whose characteristics include undergraduate students ages 18 to 23 living with T1DM for 2 years or more who attended large, public, 4-year universities located in the southeastern United States. Results Three main themes were created using theoretical constructs: symptom detection experiences, symptom interpretation experiences, and symptom response experiences. Two subthemes were identified for each theme. Participants engaged in symptom management for blood glucose regulation through detecting changes in their blood glucose physiologically and via technology. Additionally, symptom interpretation involved analyzing blood glucose trends and determining common causes of blood glucose changes. Symptom response included immediately addressing hypoglycemia but delayed responses addressing hyperglycemia. Conclusions Challenges were present responding to hypoglycemia; therefore, additional research is warranted to improve symptom response skills.
Deliberations of the Safety Task Force: Risk factors and treatment of adverse events associated with aesthetic injectables
Nikolis, Andreas , Cohen, Joel L. , Enright, Kaitlyn M. , Avelar, Luiz Eduardo Toledo , Beleznay, Katie, Biesman, Brian S. , Cartier, Hugues , Cotofana, Sebastian , Fabi, Sabrina G. , Parada, Meire Brasil, Rzany, Berthold, Wang, Hang, Bromée, Torun, Weiner, Steven C., Avelar, Luiz , Goodman, Greg , Schelke, Leonie , Cotofana, Sebastian , Fitzgerald, Rebecca, Lee, Won , Weiner, Steven

Mayo Clinic

Journal of Cosmetic Dermatology | August 20, 2024 | Volume: 23 | Issue: 11 | Pages: 3551-3564

10.1111/jocd.16476 | PMID 39161297 Get It

AbstractBackgroundThe growing popularity of aesthetic procedures involving fillers, biostimulators, and neurotoxins has prompted concerns about patient safety. To address these concerns, a global Safety Task Force (STF) was formed.AimsThe inaugural STF meeting prioritized vascular compromise prevention and management, guiding clinical trial design and materials for future meetings, and collecting data from experts on current safety methods.MethodsThe STF was formed and consisted of 16 experts from nine different countries, with each possessing distinct expertise in various fields related to aesthetic injectables. Current safety data, protocols, knowledge gaps and future research priorities were discussed and voted upon.ResultsThe establishment of a global database for tracking filler‐related AEs was favored by 93% of participants. Discussions revolved around the database's scope, data standardization, and whether non‐medical contributors should be included. Aspiration as a safety technique garnered support from 73% of participants. Approximately 43% of participants incorporate ultrasound in their injections, with divergent opinions on its impact and potential when used as a standard of practice versus in AE management. Most physicians on the task force incorporated cannula use for some of their injections (93%). There were varying perspectives on treatments for vascular adverse events (VAE), the primary causes, and the adoption of new protocols in the field.ConclusionsThe STF meeting underscored the need for a coordinated effort to address complications related to HA fillers, including VAE management and hyaluronidase protocols. Reliable treatment endpoints were evaluated, but improved measurement methods are needed. Future meetings will focus on addressing delayed complications, furthering safety in this field.
Clues to revising the conventional diagnostic algorithm for endometriosis
Roman, Horace , Chapron, Charles , Golfier, François , Fauvet, R. , Delbos, Léa , Poilblanc, Mathieu, Lavoué, Vincent , Petit, E. , Perotte, Frédérique, Benjoar, Mikhael, Merlot, Benjamin , Dennis, Thomas , Boudy, Anne‐Sophie , Fedida, Benjamin, Lèguevaque, Pierre, Genre, Ludivine, Hennetier, Clothilde, Perrin, Morgane , Lucas, Nicolas, Roger, Claire‐Marie, Chantalat, Élodie , Collinet, Pierre , Descamps, Philippe , Bendifallah, Sofiane , Spiers, Andrew, Wasson, Megan , Rousset, Pascal , Akladios, Cherif Youssef , Crochet, Patrice , Fernandez, Hervé

Mayo Clinic

International Journal of Gynecology & Obstetrics | August 20, 2024 | Volume: 168 | Issue: 1 | Pages: 101-111

10.1002/ijgo.15840 | PMID 39161277 Get It

AbstractEndometriosis is a complex gynecologic disorder characterized primarily by symptoms of pelvic pain, infertility, and altered quality of life. National and international guidelines highlight the diagnostic difficulties and lack of conclusive diagnostic tools for endometriosis. Furthermore, guidelines are becoming questionable at an increasingly rapid rate as new diagnostic techniques emerge. This work aims to provide a knowledge synthesis of the relevance of various diagnostic tools and to assess areas of improvement of conventional algorithms. MEDLINE and Cochrane Library databases were searched from January 2021 to December 2023 using relevant key words. Articles evaluating the diagnostic relevance and performance of various tools were included and independently reviewed by the authors for eligibility. Included studies were assessed using the GRADE and QUADAS‐2 tools. Of the 4204 retrieved articles, 26 were included. While anamnesis and clinical examination do contribute to diagnostic accuracy, their level of evidence and impact on the diagnostic process remains limited. Although imaging techniques are recommended to investigate endometriosis, ultrasonography remains highly operator dependent. Magnetic resonance imaging appears to exhibit higher sensitivities than ultrasound. However, concerns persist with regards to the terminology, anatomical definition of lesions, and accuracies of both ultrasound and magnetic resonance imaging. Recently, several biological markers have been studied and cumulative evidence supports the contribution of noncoding RNAs to the diagnosis of endometriosis. Marginal improvements have been suggested for anamnesis, clinical examination, and imaging examinations. Conversely, some biomarkers, including the saliva microRNA signature for endometriosis, have emerged as diagnostic tools which inspire reflection on the revision of conventional diagnostic algorithms.