Citations

Clear

196 citation(s) found for "Schultz, M".

AUTOMATED RANGE-OF-MOTION DEVICE FOR TOTAL HIP ARTHROPLASTY PROSTHESIS
Prabhakar, Prashanth P., Chen, Qingshan , Schultz, Fredrick M., Lazennec, Jean Yves , An, Kai‐Nan

Mayo Clinic

Journal of Musculoskeletal Research | April 5, 2007 | Volume: 10 | Issue: 03 | Pages: 151-155

10.1142/s0218957706001790 Get It

Hip simulators are regularly used by researchers to assess total hip arthroplasty (THA) implants, range of motion, stability, and alignment of acetabular cup and stem. Previous papers have described three types of simulators: three-dimensional protractors, biaxial rocking motion (BRM) protractors, and single-axis prosthetic range-of-motion (PROM) devices. We have developed a new hip simulator in which the ROM device is completely automated in three independent axes (elevation, internal/external rotation, and plane of elevation). Coupled with the simulator, we used a FaroArm Gold Series coordinate measuring machine (CMM) to accurately align the implant components. The results show that the methodology and alignment setup are accurate and repeatable. With this simulator and digitizer, we are able to study the characteristics of numerous THA implants at various orientations of the pelvis, acetabular cup, stem, and femur.
Primary Central Nervous System Lymphoma: The Memorial Sloan-Kettering Cancer Center Prognostic Model
Abrey, Lauren E. , Ben‐Porat, Leah, Panageas, Katherine S. , Curran, Walter J. , Schultz, Christopher J. , Leibel, Steven A., Nelson, Diana F., Mehta, Minesh P. , DeAngelis, Lisa M. , Price, Leah , Yahalom, Joachim , Berkey, Brian A. , Mehta, Minesh P , Price, Leah

Mayo Clinic

Journal of Clinical Oncology | November 21, 2006 | Volume: 24 | Issue: 36 | Pages: 5711-5715

10.1200/jco.2006.08.2941 | PMID 17116938 Get It

Purpose The purpose of this study was to analyze prognostic factors for patients with newly diagnosed primary CNS lymphoma (PCNSL) in order to establish a predictive model that could be applied to the care of patients and the design of prospective clinical trials. Patients and Methods Three hundred thirty-eight consecutive patients with newly diagnosed PCNSL seen at Memorial Sloan-Kettering Cancer Center (MSKCC; New York, NY) between 1983 and 2003 were analyzed. Standard univariate and multivariate analyses were performed. In addition, a formal cut point analysis was used to determine the most statistically significant cut point for age. Recursive partitioning analysis (RPA) was used to create independent prognostic classes. An external validation set obtained from three prospective Radiation Therapy Oncology Group (RTOG) PCNSL clinical trials was used to test the RPA classification. Results Age and performance status were the only variables identified on standard multivariate analysis. Cut point analysis of age determined that patients age ≤ 50 years had significantly improved outcome compared with older patients. RPA of 282 patients identified three distinct prognostic classes: class 1 (patients < 50 years), class 2 (patients ≥50; Karnofsky performance score [KPS] ≥ 70) and class 3 (patients ≥ 50; KPS < 70). These three classes significantly distinguished outcome with regard to both overall and failure-free survival. Analysis of the RTOG data set confirmed the validity of this classification. Conclusion The MSKCC prognostic score is a simple, statistically powerful model with universal applicability to patients with newly diagnosed PCNSL. We recommend that it be adopted for the management of newly diagnosed patients and incorporated into the design of prospective clinical trials.
Impact of electronic faculty evaluation on resident return rates and faculty teaching performance
Natt, Neena, Dupras, Denise M. , Schultz, Henry J., Mandrekar, Jay

Mayo Clinic

Medical Teacher | May 16, 2006 | Volume: 28 | Issue: 2 | Pages: No page available

10.1080/01421590600603608 Get It

Choristoma of the Optic Nerve: Case Report
Reynolds, Carol, Leavitt, Jacqueline A., Schultz, Gregory A., Garrity, James A., Ebersold, Michael J., Scheithauer, Bernd W., Salomão, Diva R. , Giannini, Caterina

Mayo Clinic

Neurosurgery | July 30, 2004 | Volume: 50 | Issue: 5 | Pages: 1125-1128

10.1097/00006123-200205000-00032 | PMID 11987274 Get It

Abstract OBJECTIVE AND IMPORTANCE: Optic nerve choristoma is a rare lesion composed of adipose tissue and smooth muscle involving the optic nerve. Few cases have been reported. CLINICAL PRESENTATION: A 20-year-old woman presented with a history of slowly progressive visual loss in the left eye. On T1-weighted magnetic resonance imaging studies, after frequency-selective fat saturation, an optic nerve mass was detected at the level of the optic canal with signal characteristics suggesting the diagnosis of optic nerve lipoma. INTERVENTION: At left frontotemporal craniotomy, the intracranial optic nerve appeared thin and atrophic proximally and was covered by abundant adipose tissue distally. Because no cleavage plane could be identified between the fatty lesion and the optic nerve, which appeared splayed within the adipose tissue, the nerve was resected after an intraoperative biopsy. The presence of two heterotopic mesodermal elements, a rim of adipose tissue admixed with bundles of mature smooth muscle, extending into the nerve septa, warranted a diagnosis of optic nerve choristoma. CONCLUSION: Optic nerve choristoma is an uncommon optic nerve lesion. Even if imaging studies are highly suggestive of the diagnosis, pathological confirmation is required because of the high adipose tissue content in the majority of cases. The lesion, most likely malformative and nonneoplastic in nature, can be the cause of progressive visual loss.
STRUCTURAL PROPERTIES OF THE SUPRASPINATUS TENDON IN TWO JOINT POSITIONS
Halder, Andreas M. , Zobitz, Mark E., Schultz, Fred M., An, Kai‐Nan

Mayo Clinic

Journal of Musculoskeletal Research | April 22, 2003 | Volume: 05 | Issue: 02 | Pages: 105-112

10.1142/s0218957701000489 Get It

The supraspinatus tendon is frequently involved in rotator cuff tears. It has been suggested that joint position affects the structural mechanics of the tendon–bone complex. The purpose of this study was to determine regional variations in structural properties of the supraspinatus tendon in two glenohumeral positions. Supraspinatus tendons from 17 fresh frozen cadavers were divided into three strips of equal width and tested with a material-testing machine. The arm orientation was either in hanging position or 60 degrees glenohumeral abduction corresponding to 90 degrees arm abduction assuming 30 degrees scapular rotation. Tensile force, tendon elongation and failure mode were recorded. Overall, there was no significant difference in structural properties between hanging arm position and 60 degrees of glenohumeral abduction (p>0.05). However, the mean ultimate load (385 N, SD 56 N) and mean ultimate stress (14 MPa, SD 3 MPa) of the anterior tendon section with the arm in glenohumeral abduction were lower in 60 degrees abduction than in the hanging arm position (611 N, SD 276 N; 24 MPa, SD 10 MPa). In hanging arm position, the anterior tendon portion had a significantly greater ultimate load and stiffness than the middle and posterior portions (p<0.05). The regional variation in structural properties substantiates the clinical finding that rotator cuff ruptures easily extend posteriorly. Our study suggests that glenohumeral abduction reduces the failure strength of the supraspinatus tendon, specifically of its anterior portion. In our study, the maximum load of the anterior portion was substantially higher than predicted maximum loads transmitted physiologically through the entire tendon.
Dynamic Pressure Transmission Through Agarose Gels
Saris, Daniël B.F. , Mukherjee, Nilay, Berglund, Lawrence J., Schultz, Fredrick M., An, Kai‐Nan, O’Driscoll, Shawn W. , Fitzsimmons, James S

Mayo Clinic

Tissue Engineering | July 26, 2002 | Volume: 6 | Issue: 5 | Pages: 531-537

10.1089/107632700750022170 | PMID 11074939 Get It