MOMENT ARMS OF THE ARM MUSCLES AT THE GLENOHUMERAL JOINT USING THE TENDON EXCURSION METHOD

Journal of Musculoskeletal Research | September 15, 2008 | Volume: 11 | Issue: 02 | Pages: 45-53

10.1142/s0218957708001973

Muscle moment arm defines the function of the muscle. To date, moment arms of the arm muscles at the glenohumeral joint using the tendon excursion method have not been reported. As the functions of these muscles at the shoulder joint are controversial, this study was undertaken to determine the moment arms of the long and short heads of the biceps (LHB, SHB), the coracobrachialis, and the long head of the triceps muscles. The moment arms were determined in 10 cadaveric shoulders by measuring the tendon excursion when the arm was rotated by 1 radian (57.3°) in 22 different motions. The LHB was a flexor, horizontal flexor, and abductor. The SHB and coracobrachialis were flexors, horizontal flexors, and adductors. The long head of the triceps was an extensor and adductor. Arm rotation significantly affected the function of the LHB only: it was an internal rotator in flexion and an external rotator in abduction. This study clarifies the individual function of the arm muscles at the glenohumeral joint.
AUTOMATED RANGE-OF-MOTION DEVICE FOR TOTAL HIP ARTHROPLASTY PROSTHESIS

Journal of Musculoskeletal Research | April 5, 2007 | Volume: 10 | Issue: 03 | Pages: 151-155

10.1142/s0218957706001790

Hip simulators are regularly used by researchers to assess total hip arthroplasty (THA) implants, range of motion, stability, and alignment of acetabular cup and stem. Previous papers have described three types of simulators: three-dimensional protractors, biaxial rocking motion (BRM) protractors, and single-axis prosthetic range-of-motion (PROM) devices. We have developed a new hip simulator in which the ROM device is completely automated in three independent axes (elevation, internal/external rotation, and plane of elevation). Coupled with the simulator, we used a FaroArm Gold Series coordinate measuring machine (CMM) to accurately align the implant components. The results show that the methodology and alignment setup are accurate and repeatable. With this simulator and digitizer, we are able to study the characteristics of numerous THA implants at various orientations of the pelvis, acetabular cup, stem, and femur.
Dynamic Pressure Transmission Through Agarose Gels

Tissue Engineering | July 26, 2002 | Volume: 6 | Issue: 5 | Pages: 531-537

10.1089/107632700750022170 | PMID 11074939