Citations

Clear

44 citation(s) found for "Watson, Robert".

Prospective evaluation of the utility of magnetic resonance imaging in patients with non‐MRI‐conditional pacemakers and defibrillators
Padmanabhan, Deepak , Kella, Danesh , Isath, Ameesh , Tandon, Nidhi , Mulpuru, Siva K. , Deshmukh, Abhishek , Mehta, Ramila A. , Dalzell, Connie, Olson, Nora E., Felmlee, Joel P. , Jondal, Mary Lou, Asirvatham, Samuel J. , Watson, Robert E. , Cha, Yong‐Mei , Friedman, Paul A. , Mulpuru, Siva K , Kapa, Suraj , Mehta, Ramila, Olson, Nora, Felmlee, Joel, Jondal, Mary L, Asirvatham, Samuel J , Cha, Yong-Mei , Friedman, Paul A , Kella, Danesh K , Kapa, Suraj

Mayo Clinic

Journal of Cardiovascular Electrophysiology | August 5, 2020 | Volume: 31 | Issue: 11 | Pages: 2931-2939

10.1111/jce.14705 | PMID 32757438 Get It

AbstractBackgroundMagnetic resonance imaging (MRI) in patients with legacy cardiovascular implantable electronic devices (CIEDs) in situ is likely underutilized. We hypothesized the clinical benefit of MRI would outweigh the risks in legacy CIED patients.MethodsThis is a single‐center retrospective study that evaluated and classified the utility of MRI using a prospectively maintained database. The outcomes were classified as aiding in diagnosis, treatment, or both for the patients attributable to the MRI. We then assessed the incidence of adverse effects (AE) when the MRI was performed.ResultsIn 668, MRIs performed on 479 patients, only 13 (1.9%) MRIs did not aid in the diagnosis or treatment of the patient. Power‐on reset events without clinical sequelae in three scans (0.45%) were the only AE. The probability of an adverse event happening without any benefit from the MRI scan was 1.1 × 10−4. A maximum benefit in diagnosis using MRI was obtained in ruling out space‐occupying lesions (121/185 scans, 65.4%). Scans performed in patients for elucidating answers to queries in treatment were most frequently done for disease staging at long term follow‐up (167/470 scans, 35.5%). Conservative treatment (184/470 scans, 39%) followed by medication changes (153/470 scans, 28.7%) were the most common treatment decisions made.ConclusionsThe utility of MRI in patients with non‐MRI‐conditional CIEDs far outweighs the risk of adverse events when imaging is done in the context of a multidisciplinary program that oversees patient safety.
Factors Associated With Large Improvements in Health-Related Quality of Life in Patients With Atrial Fibrillation
Holmes, DaJuanicia N. , Pieper, Karen S. , Ezekowitz, Michael D. , Fonarow, Gregg C. , Gersh, Bernard J. , Kowey, Peter R. , Mahaffey, Kenneth W. , Reiffel, James A. , Singer, Daniel E. , Piccini, Jonathan P. , Mendelson, R. A., NEUTEL, J, Pan, Dengji, Poock, James J., Raffetto, J.D., Greengold, R., Roan, P G, Saba, F., Sackett, Melanie K., Schneider, R., Seymour, Zachary , Shanes, Jeffrey G., Smiley, Nasser, Smith, David H. , Snipes, C., Sotolongo, Rodolfo, Staniloae, Cezar , Stoltz, S., Suresh, D.P. , Tak, Tahir , Tannenbaum, A., Turk, Samir, Vora, Kishor, Randhawa, P., Zebrack, James S., Silva, Eduardo , Riley, Edward T., Weinstein, D., Vasiliauskas, Tomas, Goldbarg, Seth , Yarlagadda, Chakri, Laurion, D., Osunkoya, A., Burns, Richéal , Castor, Tatsiana , Luttman, C., Anton, Stephen D. , McGarvey, Jeremy R., Guthrie, Robert D., Deriso, George T., Flood, Raymond, Fleischer, L H, Fierstein, J.S., Jacobs, George B., Adjei, Nasser, Akyea-Djamson, Ayim, Bacon, Jenny , Bedwell, Noel W., Berger, PB, Berry, Joni I., Bhagwat, Ravi, Boccalandro, Fernando , Capó, Jaïr Dilmé, Kapadia, Sumit, Casanova, Rene, Morriss, J.E., Elsen, J., Farsad, Ramin, Fox, David J. , Frandsen, Brad, Gelernt, M., Hall, Cassandra L. , Hotchkiss, David R. , Ip, J., Jaffrani, Naseem, Kazmierski, John F., Waxman, F., Kneller, G. Larsen, Labroo, Ajay, Jaffe, Bernard M., Lebenthal, Mark, Lillestol, Michael, Leclerc, Kenneth M. , Maccaro, Paul, Mayer, Nolan, Kozłowski, J , Benjamin, Sanford P., Detweiler, Robert, Igic, Petar, Jackson, Tatum, Pappas, Janine, Littlefield, Ryan , Frey, Anna , Vranian, Robert B., Long, W., Grena, Paul, Arouni, Amy , Quinn, John , Blonder, Ronald, Snyder, H., Slabic, S., Cohen, Kenneth D., Walthall, W. W., Snoddy, Brian, Alvarado, Olga Franco, Leach, Corinne L., Rothman, Steven A., Olatidoye, Abiodun G, Almahameed, Soufian , Rosenthal, Shelly, Reiter, William M., Thompson, T., Thew, Stephen, Kobayashi, Junji , Williams, M., Kramer, Joel H. , Latif, Sidrah , Rhee, B., Ruiz-Serrano, D., Stringam, Stanley, Wolok, K., Focil, Augusto, Butman, Samuel, Ingersoll, Henry, Borge, R. P., Al-Saghir, Y., Farris, Neil, Shore, Karen, Gornick, C., Eilat, P., Paliwal, Y., Mitra, Rito , Jingo, Ahmad, Aslam, Asma , Watson, Robert, Voyce, Stephen , Turakhia, Mintu P. , Goytia-Leos, D., Lurie, Miriam, Mallis, G., Strobel, John, Fisher, D M, Atieh, Mutaz I., Drabick, Andrew, Harman, Ece, Ashcraft, B., Krista, M., Videlefsky, A., Zayas, E. Rivera, Tan, A.E., Gersh, Bernard J , Turakhia, Mintu P , Steinberg, Benjamin A. , Allen, Larry A. , Chan, Paul S. , Freeman, James V. , Hylek, Elaine M. , Naccarelli, Gerald V. , Peterson, Eric D. , Mendelson, R., AL-NAHHAS, ADIL M. , Padanilam, B., Pan, D., Raffetto, J., Roan, P., Sackett, M., Seymour, Z., Shoemaker, J. Kevin , Simms, V., Tak, T., Riley, E., Weinstein, D., Hayward, D., Burns, R., Spiller, D., McGarvey, J., Guthrie, R., Flood, R., Aggarwal, R., Jacobs, G., Alfieri, A., Bacon, J., Berger, P., Berry, J., Bloom, S., Kapadia, S., Casanova, R., Christensen, T., Fox, D., Gill, S., Grubb, Søren , Hall, C., Harris, H., Hotchkiss, D., Jones, A., Lee, David S. , Kozlowski, J., Benjamin, S., Detweiler, R., Jackson, T., Littlefield, R., Long, W., Quinn, J., Browne, Kevin D. , Forman, Steven L. , Ebinger, Martin , Williams, David Michael , Stein, R., Kirkland, S., Cohen, K., Walthall, W., Davis, Keith L. , Alvarado, O., Leach, C., Sharma, Anand , Sutter, G., Reiter, W., Kobayashi, J., Kramer, J., Latif, S.A., Adler, Alma J , Butman, Samuel M. , Coats, Paul , Shore, K., Schwartz, M.B., Quinlan, E., Mitra, R., Aslam, A.A., Lurie, M., Atwater, Brett D. , Murray, John M. , Fisher, D., Landes, Reid D. , Harman, E., Zayas, E. Rivera

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | April 16, 2020 | Volume: 13 | Issue: 5 | Pages: No page available

10.1161/circep.119.007775 | PMID 32298144 Get It

Background: Atrial fibrillation (AF) adversely impacts health-related quality of life (hrQoL). While some patients demonstrate improvements in hrQoL, the factors associated with large improvements in hrQoL are not well described. Methods: We assessed factors associated with a 1-year increase in the Atrial Fibrillation Effect on Quality-of-Life score of 1 SD (≥18 points; 3× clinically important difference), among outpatients in the Outcomes Registry for Better Informed Treatment of Atrial Fibrillation I registry. Results: Overall, 28% (181/636) of patients had such a hrQoL improvement. Compared with patients not showing large hrQoL improvement, they were of similar age (median 73 versus 74, P =0.3), equally likely to be female (44% versus 48%, P =0.3), but more likely to have newly diagnosed AF at baseline (18% versus 8%; P =0.0004), prior antiarrhythmic drug use (52% versus 40%, P =0.005), baseline antiarrhythmic drug use (34.8% versus 26.8%, P =0.045), and more likely to undergo AF-related procedures during follow-up (AF ablation: 6.6% versus 2.0%, P =0.003; cardioversion: 12.2% versus 5.9%, P =0.008). In multivariable analysis, a history of alcohol abuse (adjusted OR, 2.41; P =0.01) and increased baseline diastolic blood pressure (adjusted OR, 1.23 per 10-point increase and >65 mm Hg; P =0.04) were associated with large improvements in hrQoL at 1 year, whereas patients with prior stroke/transient ischemic attack, chronic obstructive pulmonary disease, and peripheral arterial disease were less likely to improve ( P <0.05 for each). Conclusions: In this national registry of patients with AF, potentially treatable AF risk factors are associated with large hrQoL improvement, whereas less reversible conditions appeared negatively associated with hrQoL improvement. Understanding which patients are most likely to have large hrQoL improvement may facilitate targeting interventions for high-value care that optimizes patient-reported outcomes in AF. Registration: URL: http://www.clinicaltrials.gov . Unique identifier: NCT01165710.
P4126Safety of magnetic resonance imaging in patients with non-conditional cardiac implantable electronic devices: A systematic review and meta-analysis
Padmanabhan, Deepak , Izath, A, Al‐Masry, Anas Abudan , Gamero, Sonia Fortin, Barout, Ahmad, Assaf, Yazan , Shetty, Devi Prasad , Asirvatham, S, Felmlee, Joel P. , Watson, Robert E. , Cha, Y, Friedman, Paul A. , Farwati, Medhat , Al-Masry, A, Kella, Danesh

Mayo Clinic

European Heart Journal | October 21, 2019 | Volume: 40 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehz745.0698 Get It

Abstract Recent guideline statements approve the performance of magnetic resonance imaging (MRI) in patients with non-conditional cardiac implantable electronic devices (CIEDs) under certain closely monitored conditions. Data from current registries may have lower power to discern changes that may occur in the CIED after the MRI. Objective We aimed to systematically review the literature to identify the adverse events and significance of changes in device function associated with performing MRI in patients with CIEDs Methods A comprehensive literature search of the databases was performed between 1980- 2017. Two independent reviewers selected studies and extracted data. A random-effects model was used for meta-analysis. Results A total of 7,422 patients underwent 8,865 MRI studies. No death occurred post MRI. Clinical adverse events were extremely rare (mostly less than 1%) and are summarized in Table 1. No significant changes in the pooled mean effect size estimate was noted for the changes in the lead parameters (pacing threshold, sensing and impedance) Binary outcomes post magnetic resonance imaging in patients with non-conditional cardiac implantable electronic devices Outcome Sample size Number of patients Rate SE LL of CI UL of CI Death 7401 0 0 0 0 0 Atrial arrhythmia 7173 10 0.001 0.0004 0.0007 0.0024 Ventricular arrhythmia 7371 9 0.0012 0.0004 0.0006 0.0022 Oversensing 4981 17 0.0034 0.0008 0.0020 0.0053 Inhibition of pacing 7371 6 0.0008 0.0003 0.0003 0.0016 Lead Failure/Generator Failure 7475/7475 2/8 0.0002/0.0011 0.0001/0.0004 0.0001/0.0005 0.0009/0.002 Power on Reset 1388 105 0.0131 0.0014 0.0107 0.0161 Did not complete scan 6851 13 0.0019 0.0005 0.0011 0.0031 Chest pain 7080 11 0.0021 0.0004 0.0008 0.0027. Lead threshold rise (>0.5v/>50%-A/V) 5076/6246 12/16 0.0024/0.0026 0.0007/0.0006 0.0013/0.0015 0.0040/0.0041 Change in Battery voltage >0.04V 7132 42 0.0061 0.0009 0.0043 0.0079 Sensing decrease >50%-A/V 5087/5834 17/9 0.0033/0.0015 0.0008/0.0005 0.0020/0.0008 0.0052/0.0028 Impedance changes >50ohms/>50% 5810 22 0.0038 0.0008 0.0024 0.0057 Rise in cardiac enzymes 1703 26 0.0152 0.0030 0.0102 0.0219 A, atrial; V, ventricular; SE, standard Error; LL, lower limit; UL, upper limit; CI, Confidence intervals. Conclusions MRI in patients with non-conditional CIEDs can be performed with high degree of safety and low rate of clinical events when performed under standardized protocols Acknowledgement/Funding None
Image Artifact Management for Clinical Magnetic Resonance Imaging on a 7 T Scanner Using Single-Channel Radiofrequency Transmit Mode
Fagan, Andrew , Welker, Kirk M. , Amrami, Kimberly K. , Frick, Matthew A., Watson, Robert E. , Kollasch, Peter , Chebrolu, Venkata V. , Felmlee, Joel P. , Fagan, Andrew J

Mayo Clinic

Investigative Radiology | September 10, 2019 | Volume: 54 | Issue: 12 | Pages: 781-791

10.1097/rli.0000000000000598 | PMID 31503079 Get It

Objectives The aim of this work was to devise mitigation strategies for addressing a range of image artifacts on a clinical 7 T magnetic resonance imaging scanner using the regulatory-approved single-channel radiofrequency transmit mode and vendor-supplied radiofrequency coils to facilitate clinical scanning within reasonable scan times. Materials and Methods Optimized imaging sequence protocols were developed for routine musculoskeletal knee and neurological imaging. Sources of severe image nonuniformities were identified, and mitigation strategies were devised. A range of custom-made high permittivity dielectric pads were used to compensate for B1 + and B1 − inhomogeneities, and also for magnetic susceptibility-induced signal dropouts particularly in the basal regions of the temporal lobes and in the cerebellum. Results Significant improvements in image uniformity were obtained using dielectric pads in the knee and brain. A combination of small voxels, reduced field of view B0 shimming, and high in-plane parallel imaging factors helped to minimize signal loss in areas of high susceptibility-induced field distortions. The high inherent signal-to-noise ratio at 7 T allowed for high receiver bandwidths and thin slices to minimize chemical shift artifacts. Intermittent artifacts due to radiofrequency inversion pulse limitations (power, bandwidth) were minimized with dielectric pads. A patient with 2 implanted metallic cranial fixation devices located within the radiofrequency transmit field was successfully imaged, with minimal image geometric distortions. Conclusions Challenges relating to severe image artifacts at 7 T using single-channel radiofrequency transmit functionality in the knee and brain were overcome using the approaches described in this article. The resultant high diagnostic image quality paves the way for incorporation of this technology into the routine clinical workflow. Further developmental efforts are required to expand the range of applications to other anatomical areas, and to expand the evidence- and knowledge-base relating to the safety of scanning patients with implanted metallic devices.
Segmentation errors and intertest reliability in automated and manually traced hippocampal volumes
Brinkmann, Benjamin H. , Kenney‐Jung, Daniel , Mandrekar, Jay , Watson, Robert E. , Welker, Kirk M. , Witte, Robert J. , Guragain, Hari, Watson, Robert E , Brinkmann, Benjamin H , Guragain, Hari, Britton, Jeffrey W.

Mayo Clinic

Annals of Clinical and Translational Neurology | September 6, 2019 | Volume: 6 | Issue: 9 | Pages: 1807-1814

10.1002/acn3.50885 | PMID 31489797 Get It

AbstractObjectiveTo rigorously compare automated atlas‐based and manual tracing hippocampal segmentation for accuracy, repeatability, and clinical acceptability given a relevant range of imaging abnormalities in clinical epilepsy.MethodsForty‐nine patients with hippocampal asymmetry were identified from our institutional radiology database, including two patients with significant anatomic deformations. Manual hippocampal tracing was performed by experienced technologists on 3T MPRAGE images, measuring hippocampal volume up to the tectal plate, excluding the hippocampal tail. The same images were processed using NeuroQuant and FreeSurfer software. Ten subjects underwent repeated manual hippocampal tracings by two additional technologists blinded to previous results to evaluate consistency. Ten patients with two clinical MRI studies had volume measurements repeated using NeuroQuant and FreeSurfer.ResultsFreeSurfer raw volumes were significantly lower than NeuroQuant (P < 0.001, right and left), and hippocampal asymmetry estimates were lower for both automatic methods than manual tracing (P < 0.0001). Differences remained significant after scaling volumes to age, gender, and scanner matched normative percentiles. Volume reproducibility was fair (0.4–0.59) for manual tracing, and excellent (>0.75) for both automated methods. Asymmetry index reproducibility was excellent (>0.75) for manual tracing and FreeSurfer segmentation and fair (0.4–0.59) for NeuroQuant segmentation. Both automatic segmentation methods failed on the two cases with anatomic deformations. Segmentation errors were visually identified in 25 NeuroQuant and 27 FreeSurfer segmentations, and nine (18%) NeuroQuant and six (12%) FreeSurfer errors were judged clinically significant.InterpretationAutomated hippocampal volumes are more reproducible than hand‐traced hippocampal volumes. However, these methods fail in some cases, and significant segmentation errors can occur.
Gadolinium Administration in Undetected Pregnancy: Cause for Alarm?
Kallmes, David F. , Watson, Robert E.

Mayo Clinic

Radiology | August 20, 2019 | Volume: 293 | Issue: 1 | Pages: 201-202

10.1148/radiol.2019191634 | PMID 31433265 Get It

ACR guidance document on MR safe practices: Updates and critical information 2019
Greenberg, Todd D., Hoff, Michael N. , Gilk, Tobias , Och, Joseph, Rampulla, Tina L., Rogg, Jeffrey M. , Shellock, Frank G. , Watson, Robert E. , Weinreb, Jeffrey C. , Hernandez, Dina , Jackson, Edward F. , Kanal, Emanuel , McKinney, Alexander M. , Pedrosa, Iván , Reeder, Scott B.

Mayo Clinic

Journal of Magnetic Resonance Imaging | July 29, 2019 | Volume: 51 | Issue: 2 | Pages: 331-338

10.1002/jmri.26880 | PMID 31355502 Get It

The need for a guidance document on MR safe practices arose from a growing awareness of the MR environment's potential risks and adverse event reports involving patients, equipment, and personnel. Initially published in 2002, the American College of Radiology White Paper on MR Safety established de facto industry standards for safe and responsible practices in clinical and research MR environments. The most recent version addresses new sources of risk of adverse events, increases awareness of dynamic MR environments, and recommends that those responsible for MR medical director safety undergo annual MR safety training. With regular updates to these guidelines, the latest MR safety concerns can be accounted for to ensure a safer MR environment where dangers are minimized.Level of Evidence: 1Technical Efficacy Stage: 5J. Magn. Reson. Imaging 2020;51:331–338.
Patient-oriented education and visual-aid intervention are inadequate to identify patients with potential capsule retention: a prospective randomized study
Al‐Bawardy, Badr , Kamboj, Amrit K. , Desai, Shiv, Gorospe, Emmanuel C., Bruining, David H. , Gostout, Christopher J., Larson, Mark V., Nehra, Vandana, Leggett, Cadman L. , Szarka, Lawrence A., Watson, Robert E. , Rajan, Elizabeth , Gorospe, Emmanuel, Hansel, Stephanie L. , Leggett, Cadman L , Murray, Joseph A.

Mayo Clinic

Scandinavian Journal of Gastroenterology | April 30, 2019 | Volume: 54 | Issue: 5 | Pages: 662-665

10.1080/00365521.2019.1608465 | PMID 31034255 Get It

An unusual presentation of late-onset Alexander’s disease with slow orthostatic tremor and a novel GFAP variant
Stitt, Derek , Gavrilova, Ralitza H. , Watson, Robert E. , Hassan, Anhar , Stitt, Derek W, Watson, Robert

Mayo Clinic

Neurocase | February 13, 2019 | Volume: 24 | Issue: 5-6 | Pages: 266-268

10.1080/13554794.2019.1580749 | PMID 30755139 Get It

Augmenting MRI Safety Screening Processes: Reliable Identification of Cardiac Implantable Electronic Devices by a Ferromagnetic Detector System
Watson, Robert E. , Walsh, S., Felmlee, Joel P. , Friedman, Paul A. , Keene, Mark N., Walsh, Suson M

Mayo Clinic

Journal of Magnetic Resonance Imaging | September 26, 2018 | Volume: 49 | Issue: 7 | Pages: No page available

10.1002/jmri.26277 | PMID 30257050 Get It

Level of Evidence: 1Technical Efficacy Stage: 5 J. Magn. Reson. Imaging 2019;49:e297–e299.