Citations

Clear

88 citation(s) found for "Sio, Terence".

The effective normal tissue non-complication probability (E0): a probabilistic methodology in the representation of the stochastic health safety effects of low levels of ionizing radiation on the human tissues or organs
Frometa-Castillo, Terman , Pyakuryal, Anil, Narayanasamy, G. , Sio, Terence T.

Mayo Clinic

International Journal of Radiation Biology | February 3, 2025 | Volume: 101 | Issue: 4 | Pages: 422-426

10.1080/09553002.2025.2459098 | PMID 39898896 Get It

Systemic Therapy for Stage I-III Anal Squamous Cell Carcinoma: ASCO Guideline
Morris, Van K. , Kennedy, Erin B. , Amin, Manik , Aranha, Olivia , Benson, Al B. , Dorth, Jennifer A. , Horowitz, David P. , Kennecke, Hagen F. , Kim, Stéfano , Kreppel, Lillian, Rajdev, Lakshmi , Mettu, Niharika B , Riechelmann, Rachel , Sio, Terence T , Eng, Cathy , Riechelmann, Rachel P. , Sio, Terence T. , Eng, Cathy

Mayo Clinic

Journal of Clinical Oncology | December 16, 2024 | Volume: 43 | Issue: 5 | Pages: 605-615

10.1200/jco-24-02120 | PMID 39680825 Get It

ASCO Guidelines provide recommendations with comprehensive review and analyses of the relevant literature for each recommendation, following the guideline development process as outlined in the ASCO Guidelines Methodology Manual . ASCO Guidelines follow the ASCO Conflict of Interest Policy for Clinical Practice Guidelines . Clinical Practice Guidelines and other guidance (“Guidance”) provided by ASCO is not a comprehensive or definitive guide to treatment options. It is intended for voluntary use by clinicians and should be used in conjunction with independent professional judgement. Guidance may not be applicable to all patients, interventions, diseases or stages of diseases. Guidance is based on review and analysis of relevant literature and is not intended as a statement of the standard-of-care. ASCO does not endorse third-party drugs, devices, services, or therapies and assumes no responsibility for any harm arising from or related to the use of this information. See complete disclaimer in Appendix 1 and 2 (online only). PURPOSE To provide evidence-based guidance for clinicians who treat patients with stage I-III anal cancer. METHODS A systematic review of the literature conducted by the Minnesota Evidence-based Practice Center provided the evidence base for this guideline. An ASCO Expert Panel reviewed this evidence and came to consensus on a set of evidence-based recommendations. RESULTS The systematic review contained three randomized controlled trials and three nonrandomized studies of interventions that were relevant to the guideline topic and informed the recommendations. RECOMMENDATIONS Mitomycin-C (MMC) with a fluoropyrimidine (fluorouracil [FU] or capecitabine) is recommended as the radiosensitizing component of chemoradiation (CRT) for anal cancer; the Expert Panel recognizes that capecitabine is often used as an orally administered alternative to FU and is currently being used in ongoing clinical trials. Cisplatin with FU is an additional chemotherapy combination that may be recommended as radiosensitizing chemotherapy. Because of the myelosuppression associated with MMC, the preferable regimen for patients with immunosuppression is cisplatin and FU. Cisplatin is not recommended for patients with renal dysfunction, significant neuropathy, or hearing loss, and there is no evidence to recommend substituting carboplatin for cisplatin. Dose and schedule options for recommended chemotherapy agents are included within the full text of the guideline. Routine induction chemotherapy before CRT and additional chemotherapy after CRT are not recommended for patients with localized anal cancer. Additional information is available at www.asco.org/gastrointestinal-cancer-guidelines .
Results from METIS (EF-25), an international, multicenter phase III randomized study evaluating the efficacy and safety of tumor treating fields (TTFields) therapy in NSCLC patients with brain metastases.
Gondi, Vinai , Ilić, Rosanda , Muanza, Thierry , Krpan, Ana Mišir , Ramakrishna, Naren , Fiveash, John B. , Métellus, Philippe , Wang, Chiachien Jake, Feuvret, L. , Csőszi, Tibor , Brown, Paul D. , Zhu, Zhengfei, Yu, Jinming , Mehta, Minesh P. , Ahluwalia, Manmeet S. , Roberge, David , Sio, Terence T. , Trifiletti, Daniel M. , Freyschlag, Christian Franz , Zhu, Zhengfei , Harat, Maciej

Mayo Clinic

Journal of Clinical Oncology | June 4, 2024 | Volume: 42 | Issue: 16_suppl | Pages: 2008-2008

10.1200/jco.2024.42.16_suppl.2008 Get It

2008 Background: For non-small cell lung cancer (NSCLC) with brain metastases (BM) stereotactic radiosurgery (SRS) is the current preferred therapy. Due to frequent intracranial failures, there is a high unmet need for salvage therapies. Whole brain radiotherapy (WBRT) reduces intracranial failure but used less frequently due to cognitive consequences. Tumor Treating Fields (TTFields) are electric fields that disrupt cancer cell division and have shown improved survival and safety in patients with glioblastoma and metastatic NSCLC. Phase 3 METIS trial [NCT02831959] aimed to evaluate the efficacy and safety of TTFields therapy in NSCLC patients with BM treated with SRS, specifically in terms of lengthening time to intracranial progression without cognitive decline. Methods: Mutation negative (M-) NSCLC patients with 1–10 BM were randomized 1:1 to receive stereotactic radiosurgery (SRS) followed by Tumor Treating Fields (TTFields; 150 kHz) therapy with best supportive care (BSC) or SRS followed by BSC. Patients with Karnofsky Performance Status (KPS) ≥70, newly diagnosed with one inoperable or 2–10 supra-/infratentorial brain metastases suitable for SRS and receiving optimal extracranial disease therapy were included. Exclusions were prior WBRT and single operable or recurrent brain metastases. Primary endpoint was time to first intracranial progression (RANO-BM) based on cumulative risk. Patients were followed every two months until second intracranial progression. Cognition and patient quality of life (QoL) were evaluated. Results: Between July 2016 and September 2022, 298 patients were randomized. Baseline characteristics were balanced: median age was 63.5 (range 37-84) years, 37.6% females, majority of patients had a KPS ≥ 80, median time from initial NSCLC diagnosis was 1.8 months (range: 0.2-55.7), 77% had adenocarcinoma. Median treatment duration of TTFields was 16 weeks, with a median usage time of 67%. Primary endpoint, time to intracranial progression from SRS, was significantly prolonged with SRS followed by TTFields therapy with BSC vs. BSC alone arm (median of 21.9 vs. 11.3 months); HR=0.67 [0.48-0.93], p=0.02. TTFields-related AEs were mainly dermatological, and Grade ≤2. TTFields therapy also improved deterioration-free survival of global health status, physical functioning, and fatigue according to QoL, and did not negatively impact cognition. Conclusion: METIS study met its primary endpoint, demonstrating that TTFields therapy following SRS in mutation negative NSCLC patients with BM, significantly prolongs time to intracranial progression and could postpone WBRT, without QoL and cognition decline. Clinical trial information: NCT02831959 .
B-cell acute lymphoblastic leukemia associated with hypereosinophilia: a case report and brief literature review
Khosravi, Sahar , Mousavi‐Fatemi, Khatereh, Barary, Mohammad , Sio, Terence T., Pirzaman, Ali Tavakoli , Tavakoli Pirzaman, Ali , Barary, Mohammad , Ebrahimi, Pouyan

Mayo Clinic

SAGE Open Medical Case Reports | January 31, 2024 | Volume: 12 | Issue: No issue available | Pages: No page available

10.1177/2050313x241229592 | PMID 38304855 Get It

Few cases of B-cell acute lymphoblastic leukemia (B-ALL)-eosinophilia (ALL-eo) association have been reported. The lack or absence of blasts in the peripheral blood smear (PBS) along with urticarial rash, fever, arthralgia, myalgia, sweating, and dyspnea are common features of this condition. Herein, we report a 16-year-old male patient admitted to the emergency department with urticaria and generalized itching. PBS was examined, and eosinophils (90%) were seen in different fields. However, blast cells were not seen in PBS. In a bone marrow examination, terminal deoxynucleotidyl transferase-positive and CD20-positive lymphoid blasts were reported along with eosinophilia. Eventually, the B-ALL diagnosis was confirmed for the patient, and he was started on the Berlin-Frankfurt-Münster chemotherapy regimen. The association of B-ALL with hypereosinophilia is a rare condition. We hope this case report and literature review can help clinicians to manage this rare condition properly.
Breakthrough SARS-CoV-2 infections after vaccination: A critical review
Afshar, Zeinab Mohseni, Barary, Mohammad , Mansouri, Feizollah , Ebrahimpour, Soheil , Nazary, Kosar, Carson‐Chahhoud, Kristin , Barary, Mohammad , Carson-Chahhoud, Kristin , Afshar, Zeinab Mohseni , Sio, Terence T. , Sullman, Mark J. M. , Babazadeh, Arefeh

Mayo Clinic

No container title available | January 31, 2024 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.170668473.38426771/v1 Get It

At the beginning of the current pandemic, it was believed that severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection would induce lifelong immunity and that reinfections would be unlikely. However, after several cases of reinfection were documented in previously infected patients, this was understood to be a false assumption, and this waning humoral immunity has raised significant concerns. Accordingly, long-term and durable vaccine-induced antibody protection against infection have also become a challenge, as several breakthroughs of COVID-19 infection have been identified in individuals who were fully vaccinated. This review discusses the current evidence on breakthrough COVID-19 infections occurring after vaccination.
RADT-25. IMPACT OF 18F-DOPA PET ON RADIATION TREATMENT PLANNING FROM PHASE II STUDY OF SHORT COURSE HYPOFRACTIONATED PROTON BEAM THERAPY FOR ELDERLY PATIENTS WITH GLIOBLASTOMA
Laughlin, Brady, Pafundi, Deanna, Ashman, Jonathan B. , Breen, William G. , Ruff, Michael W. , Mahajan, Anita , Mrugała, Maciej M. , Uhm, Joon H. , Brinkmann, Debra H. , Brown, Paul D. , Hu, Leland , Vora, Sujay A., Buras, Matthew , Bendok, Bernard R. , Laack, Nadia N. , Sio, Terence T. , Yang, Ming

Mayo Clinic

Neuro-Oncology | November 11, 2023 | Volume: 25 | Issue: Supplement_5 | Pages: v54-v54

10.1093/neuonc/noad179.0214 Get It

Abstract PURPOSE 18F-DOPA is sensitive/specific for identifying areas of biologically aggressive disease for glioblastoma. We report the impact of 18F-DOPA on radiation treatment planning from a phase II study. METHODS Gross target volume (GTV) was defined by the boolean of high-risk PET (tumor/normal brain SUV > 2.0) and MRI T1 contrast enhancement (MRI-CE) including surgical cavity. The clinical target volume (CTV) included the GTV with 1cm margin. Using proton beam therapy, GTV ≤ 65 cc was treated with 25 (CTV), 30 (MRI-CE), and 35 (PET) GyE over 5 fractions with a simultaneous integrated boost. GTV > 65 cc received 30 (CTV), 35 (MRI-CE), and 40 (PET) GyE over 10 fractions. Radiation field design was compared to traditional 1.5cm CTV margin on MRI-CE. RESULTS Between May 2019 and October 2021, 39 patients were treated. The median MRI-CE tumor diameter was 5.2cm. The median PET volume was 7.9cc (range 0–64.9cc). The median MRI-CE volume was 35.1cc (range 8.6–114cc). High-risk PET was contained within: MRI-CE 18/39 (46%), MRI-CE + T2W FLAIR 13/39 (33%), MRI-CE + T2W FLAIR + outside GTV 4/39 (10%), outside GTV 2/39 (5%) and no uptake 2/39 (5%). Utilizing this planning technique, there was a 26% volume reduction in CTV to traditional 1.5 cm margin on MRI-CE. PET imaging in treatment planning allowed inclusion of high-risk disease that would have been excluded on traditional CTV in 23% of cases (range 1.6-33.8cc). PET was more predictive [HR 1.03 (95% CI 1.01, 1.05) p = 0.002] than MRI [HR 1.01 (95% CI 1.00, 1.03) p = 0.02] for death with each cc increasing risk of death by 3.1%. CONCLUSIONS The incorporation of 18F-DOPA in treatment planning yields a more targeted approach with reductions in both normal brain treated and risk of geographic miss compared to traditional CTV margins.
Modelling small block aperture in an in-house developed GPU-accelerated Monte Carlo-based dose engine for pencil beam scanning proton therapy
Feng, Hongying , Holmes, Jason , Vora, Sujay A., Stoker, J. , Bues, Martin , Wong, William W. , Sio, Terence S., Foote, Robert L. , Patel, Samir H. , Holmes, Jason M , Stoker, Joshua B., Shen, Jiajian , Liu, Wei , Bues, Martin , Shen, Jiajian , Liu, Wei

Mayo Clinic

Physics in Medicine & Biology | November 9, 2023 | Volume: 69 | Issue: 3 | Pages: 035003

10.1088/1361-6560/ad0b64 | PMID 37944480 Get It

Abstract Purpose . To enhance an in-house graphic-processing-unit accelerated virtual particle (VP)-based Monte Carlo (MC) proton dose engine (VPMC) to model aperture blocks in both dose calculation and optimization for pencil beam scanning proton therapy (PBSPT)-based stereotactic radiosurgery (SRS). Methods and materials . A module to simulate VPs passing through patient-specific aperture blocks was developed and integrated in VPMC based on simulation results of realistic particles (primary protons and their secondaries). To validate the aperture block module, VPMC was first validated by an opensource MC code, MCsquare, in eight water phantom simulations with 3 cm thick brass apertures: four were with aperture openings of 1, 2, 3, and 4 cm without a range shifter, while the other four were with same aperture opening configurations with a range shifter of 45 mm water equivalent thickness. Then, VPMC was benchmarked with MCsquare and RayStation MC for 10 patients with small targets (average volume 8.4 c.c. with range of 0.4–43.3 c.c.). Finally, 3 typical patients were selected for robust optimization with aperture blocks using VPMC. Results . In the water phantoms, 3D gamma passing rate (2%/2 mm/10%) between VPMC and MCsquare was 99.71 ± 0.23%. In the patient geometries, 3D gamma passing rates (3%/2 mm/10%) between VPMC/MCsquare and RayStation MC were 97.79 ± 2.21%/97.78 ± 1.97%, respectively. Meanwhile, the calculation time was drastically decreased from 112.45 ± 114.08 s (MCsquare) to 8.20 ± 6.42 s (VPMC) with the same statistical uncertainties of ~0.5%. The robustly optimized plans met all the dose–volume-constraints (DVCs) for the targets and OARs per our institutional protocols. The mean calculation time for 13 influence matrices in robust optimization by VPMC was 41.6 s and the subsequent on-the-fly ‘trial-and-error’ optimization procedure took only 71.4 s on average for the selected three patients. Conclusion . VPMC has been successfully enhanced to model aperture blocks in dose calculation and optimization for the PBSPT-based SRS.
Beam mask and sliding window‐facilitated deep learning‐based accurate and efficient dose prediction for pencil beam scanning proton therapy
Zhang, Lian , Vora, Sujay A., Vargas, Carlos , Yu, Nathan Y. , Keole, Sameer R., Liu, Tianming , Shen, Jiajian , Wong, William W. , Holmes, Jason M, Schild, Steven E. , Shen, Jiajian , Holmes, Jason , Liu, Zhengliang , Sio, Terence T. , Bues, Martin , Li, Sheng , Liu, Wei

Mayo Clinic

Medical Physics | September 25, 2023 | Volume: 51 | Issue: 2 | Pages: 1484-1498

10.1002/mp.16758 | PMID 37748037 Get It

AbstractBackgroundAccurate and efficient dose calculation is essential for on‐line adaptive planning in proton therapy. Deep learning (DL) has shown promising dose prediction results in photon therapy. However, there is a scarcity of DL‐based dose prediction methods specifically designed for proton therapy. Successful dose prediction method for proton therapy should account for more challenging dose prediction problems in pencil beam scanning proton therapy (PBSPT) due to its sensitivity to heterogeneities.PurposeTo develop a DL‐based PBSPT dose prediction workflow with high accuracy and balanced complexity to support on‐line adaptive proton therapy clinical decision and subsequent replanning.MethodsPBSPT plans of 103 prostate cancer patients (93 for training and the other 10 for independent testing) and 83 lung cancer patients (73 for training and the other 10 for independent testing) previously treated at our institution were included in the study, each with computed tomography scans (CTs), structure sets, and plan doses calculated by the in‐house developed Monte‐Carlo dose engine (considered as the ground truth in the model training and testing). For the ablation study, we designed three experiments corresponding to the following three methods: (1) Experiment 1, the conventional region of interest (ROI) (composed of targets and organs‐at‐risk [OARs]) method. (2) Experiment 2, the beam mask (generated by raytracing of proton beams) method to improve proton dose prediction. (3) Experiment 3, the sliding window method for the model to focus on local details to further improve proton dose prediction. A fully connected 3D‐Unet was adopted as the backbone. Dose volume histogram (DVH) indices, 3D Gamma passing rates with a criterion of 3%/3 mm/10%, and dice coefficients for the structures enclosed by the iso‐dose lines between the predicted and the ground truth doses were used as the evaluation metrics. The calculation time for each proton dose prediction was recorded to evaluate the method's efficiency.ResultsCompared to the conventional ROI method, the beam mask method improved the agreement of DVH indices for both targets and OARs and the sliding window method further improved the agreement of the DVH indices (for lung cancer, CTV D98 absolute deviation: 0.74 ± 0.18 vs. 0.57 ± 0.21 vs. 0.54 ± 0.15 Gy[RBE], ROI vs. beam mask vs. sliding window methods, respectively). For the 3D Gamma passing rates in the target, OARs, and BODY (outside target and OARs), the beam mask method improved the passing rates in these regions and the sliding window method further improved them (for prostate cancer, targets: 96.93% ± 0.53% vs. 98.88% ± 0.49% vs. 99.97% ± 0.07%, BODY: 86.88% ± 0.74% vs. 93.21% ± 0.56% vs. 95.17% ± 0.59%). A similar trend was also observed for the dice coefficients. This trend was especially remarkable for relatively low prescription isodose lines (for lung cancer, 10% isodose line dice: 0.871 ± 0.027 vs. 0.911 ± 0.023 vs. 0.927 ± 0.017). The dose predictions for all the testing cases were completed within 0.25 s.ConclusionsAn accurate and efficient deep learning‐augmented proton dose prediction framework has been developed for PBSPT, which can predict accurate dose distributions not only inside but also outside ROI efficiently. The framework can potentially further reduce the initial planning and adaptive replanning workload in PBSPT.
Anticoagulant therapy in COVID ‐19: A narrative review
Afshar, Zeinab Mohseni , Pirzaman, Ali Tavakoli , Hosseinzadeh, Rezvan , Moghadam, Mohamad Ali Taghizadeh, Miri, Seyed Rouhollah , Sio, Terence T. , Sullman, Mark J. M. , Barary, Mohammad , Ebrahimpour, Soheil , Mohseni Afshar, Zeinab , Tavakoli Pirzaman, Ali , Babazadeh, Arefeh , Miri, Seyed Rouhollah , Sio, Terence T , Sullman, Mark J M , Barary, Mohammad , Ebrahimpour, Soheil

Mayo Clinic

Clinical and Translational Science | June 16, 2023 | Volume: 16 | Issue: 9 | Pages: 1510-1525

10.1111/cts.13569 | PMID 37326220 Get It

Abstract Coronavirus disease 2019 (COVID‐19), caused by the severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2), can manifest itself in several ways, including coagulopathy and thrombosis. These complications can be the first and sometimes only manifestations of SARS‐CoV‐2 infection and can occur early or late in the course of the disease. However, these symptoms are more prevalent in hospitalized patients with venous thromboembolism, particularly those admitted to intensive care units. Moreover, various forms of arterial and venous thrombosis, or micro‐ or macro‐vasculature embolisms, have been reported during the current pandemic. They have led to harmful consequences, such as neurological and cardiac events, nearly all resulting from the hypercoagulable state caused by this viral infection. The severe hypercoagulability observed in patients with COVID‐19 accounts for most cases of the disease that become critical. Therefore, anticoagulants seem to be one of the most vital therapeutics for treating this potentially life‐threatening condition. In the current paper, we present a thorough review of the pathophysiology of COVID‐19‐induced hypercoagulable state and the use of anticoagulants to treat SARS‐CoV‐2 infections in different patient groups, as well as their pros and cons.
Deep‐learning based fast and accurate 3D CT deformable image registration in lung cancer
Ding, Yuzhen , Feng, Hongying , Yang, Yunze, Wong, William W. , Yu, Nathan Y. , Schild, Steven E. , Holmes, Jason , Liu, Zhengliang , Liu, David M. , Sio, Terence T. , Li, Baoxin , Liu, Wei

Mayo Clinic

Medical Physics | June 8, 2023 | Volume: 50 | Issue: 11 | Pages: 6864-6880

10.1002/mp.16548 | PMID 37289193 Get It

AbstractBackgroundDeformable Image Registration (DIR) is an essential technique required in many applications of radiation oncology. However, conventional DIR approaches typically take several minutes to register one pair of 3D CT images and the resulting deformable vector fields (DVFs) are only specific to the pair of images used, making it less appealing for clinical application.PurposeA deep‐learning‐based DIR method using CT images is proposed for lung cancer patients to address the common drawbacks of the conventional DIR approaches and in turn can accelerate the speed of related applications, such as contour propagation, dose deformation, adaptive radiotherapy (ART), etc.MethodsA deep neural network based on VoxelMorph was developed to generate DVFs using CT images collected from 114 lung cancer patients. Two models were trained with the weighted mean absolute error (wMAE) loss and structural similarity index matrix (SSIM) loss (optional) (i.e., the MAE model and the M+S model). In total, 192 pairs of initial CT (iCT) and verification CT (vCT) were included as a training dataset and the other independent 10 pairs of CTs were included as a testing dataset. The vCTs usually were taken 2 weeks after the iCTs. The synthetic CTs (sCTs) were generated by warping the vCTs according to the DVFs generated by the pre‐trained model. The image quality of the synthetic CTs was evaluated by measuring the similarity between the iCTs and the sCTs generated by the proposed methods and the conventional DIR approaches, respectively. Per‐voxel absolute CT‐number‐difference volume histogram (CDVH) and MAE were used as the evaluation metrics. The time to generate the sCTs was also recorded and compared quantitatively. Contours were propagated using the derived DVFs and evaluated with SSIM. Forward dose calculations were done on the sCTs and the corresponding iCTs. Dose volume histograms (DVHs) were generated based on dose distributions on both iCTs and sCTs generated by two models, respectively. The clinically relevant DVH indices were derived for comparison. The resulted dose distributions were also compared using 3D Gamma analysis with thresholds of 3 mm/3%/10% and 2 mm/2%/10%, respectively.ResultsThe two models (wMAE and M+S) achieved a speed of 263.7±163 / 265.8±190 ms and a MAE of 13.15±3.8 / 17.52±5.8 HU for the testing dataset, respectively. The average SSIM scores of 0.987±0.006 and 0.988±0.004 were achieved by the two proposed models, respectively. For both models, CDVH of a typical patient showed that less than 5% of the voxels had a per‐voxel absolute CT‐number‐difference larger than 55 HU. The dose distribution calculated based on a typical sCT showed differences of ≤2cGy[RBE] for clinical target volume (CTV) D95 and D5, within ±0.06% for total lung V5, ≤1.5cGy[RBE] for heart and esophagus Dmean, and ≤6cGy[RBE] for cord Dmax compared to the dose distribution calculated based on the iCT. The good average 3D Gamma passing rates (> 96% for 3 mm/3%/10% and > 94% for 2 mm/2%/10%, respectively) were also observed.ConclusionA deep neural network‐based DIR approach was proposed and has been shown to be reasonably accurate and efficient to register the initial CTs and verification CTs in lung cancer.