Citations

Clear

30 citation(s) found for "McCrady-Spitzer, Shelly".

Longitudinal Observation of Insulin Use and Glucose Sensor Metrics in Pregnant Women with Type 1 Diabetes Using Continuous Glucose Monitors and Insulin Pumps: The LOIS-P Study
O’Malley, Grenye , Özaslan, Başak , Levy, Carol J. , Castorino, Kristin , Desjardins, Donna, Levister, Camilla, McCrady-Spitzer, Shelly , Church, Mei Mei , Kaur, Ravinder Jeet , Reid, Corey, Kremers, Walter K. , Trinidad, Mari Charisse, Rosenn, Barak, Pinsker, Jordan E. , Kudva, Yogish C. , Dassau, Eyal , Doyle, Francis J , Pinsker, Jordan E , Kudva, Yogish C. , Dassau, Eyal , Levy, Carol J , Kremers, Walter K , Castorino, Kristin , Doyle, Francis J.

Mayo Clinic

Diabetes Technology & Therapeutics | July 16, 2021 | Volume: 23 | Issue: 12 | Pages: 807-817

10.1089/dia.2021.0112 | PMID 34270347 Get It

Background: Suboptimal glycemic control is associated with maternal and neonatal morbidity and mortality in pregnancy complicated by type 1 diabetes (T1D). Prospective analysis of continuous glucose monitoring (CGM) metrics, insulin pump settings, and insulin delivery can better characterize the changes in glycemic levels and insulin use throughout pregnancy with T1D. Materials and Methods: Prescribed parameters, insulin delivery, carbohydrate intake, and CGM data for 25 pregnant women with T1D from three U.S. sites were collected. Participants enrolled before 17 weeks gestation and used personal insulin pumps and study CGM. Mean daily total, basal, and bolus insulin doses (units/kg), CGM time in range (TIR: 63–140 mg/dL), and pump-entered carbohydrates were analyzed for every 2-week gestational interval. Linear mixed-effects regression models were used to evaluate changes across gestational ages compared to 12–14 weeks. Results: Basal insulin was higher during weeks 6–12 and 24–40. Daily bolus and total insulin were higher during weeks 20–40. Pump parameters were adjusted to intensify insulin therapy from 22 weeks onward. Average TIR across pregnancy was 59% ± 14%. Between 18 and 30 weeks, TIR was significantly lower, and time above range was significantly higher compared to the reference biweek. Time below target was lower between 22 and 34 weeks. Seven participants achieved >70% recommended TIR for pregnancy. Participants with maternal complications or infant neonatal intensive care unit admissions had lower TIR. Conclusion: While insulin dosing changed significantly with advancing gestation, most participants did not achieve >70% TIR. Customized anticipatory pump setting adjustments and automated systems aimed toward the designated TIR are needed to improve outcomes for this population. NCT03761615
Patient-Reported Outcomes in a Randomized Trial of Closed-Loop Control: The Pivotal International Diabetes Closed-Loop Trial
Kudva, Yogish C. , Laffel, Lori M. , Brown, Sue A. , Raghinaru, Dan, Pinsker, Jordan E. , Ekhlaspour, Laya , Messer, Laurel H. , Kovatchev, Boris , Lum, John W. , Gonder‐Frederick, Linda , Anderson, Stacey M. , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Ambler-Osborn, Louise, Flint, Emily, Kim, Kenny, Roethke, Lindsay, Church, Mei Mei , André, Camille , Piper, Molly, Lam, David W. , O’Malley, Grenye , Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Forlenza, Gregory P. , Alonso, G. Todd, Slover, Robert H., Jost, Emily , Berget, Cari , Towers, Lindsey, Rossick-Solis, Alex, Buckingham, Bruce A. , Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Dassau, Eyal , Passman, Samantha, Campos, Tiffany, Kollman, Craig, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreaza-Rubín, Guillermo , Green, Neal, Reznik, Yves , Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Eggerman, Thomas L., Messer, Laurel H , Lum, John , Forlenza, Gregory P , Kovatchev, Boris , Buckingham, Bruce , Levy, Carol J. , Beck, Roy W. , Oliveri, Mary Clancy , Isganaitis, Elvira , Kumari, Kanchan, Wadwa, R Paul , Doyle, Francis J. , Kollman, Craig , Renard, Eric , Cobelli, Claudio , Green, Jennifer Greif , Willi, Steven Matthew

Mayo Clinic

Diabetes Technology & Therapeutics | June 11, 2021 | Volume: 23 | Issue: 10 | Pages: 673-683

10.1089/dia.2021.0089 | PMID 34115959 Get It

Background: Closed-loop control (CLC) has been shown to improve glucose time in range and other glucose metrics; however, randomized trials >3 months comparing CLC with sensor-augmented pump (SAP) therapy are limited. We recently reported glucose control outcomes from the 6-month international Diabetes Closed-Loop (iDCL) trial; we now report patient-reported outcomes (PROs) in this iDCL trial. Methods: Participants were randomized 2:1 to CLC ( N = 112) versus SAP ( N = 56) and completed questionnaires, including Hypoglycemia Fear Survey, Diabetes Distress Scale (DDS), Hypoglycemia Awareness, Hypoglycemia Confidence, Hyperglycemia Avoidance, and Positive Expectancies of CLC (INSPIRE) at baseline, 3, and 6 months. CLC participants also completed Diabetes Technology Expectations and Acceptance and System Usability Scale (SUS). Results: The Hypoglycemia Fear Survey Behavior subscale improved significantly after 6 months of CLC compared with SAP. DDS did not differ except for powerless subscale scores, which worsened at 3 months in SAP. Whereas Hypoglycemia Awareness and Hyperglycemia Avoidance did not differ between groups, CLC participants showed a tendency toward improved confidence in managing hypoglycemia. The INSPIRE questionnaire showed favorable scores in the CLC group for teens and parents, with a similar trend for adults. At baseline and 6 months, CLC participants had high positive expectations for the device with Diabetes Technology Acceptance and SUS showing high benefit and low burden scores. Conclusion: CLC improved some PROs compared with SAP. Participants reported high benefit and low burden with CLC. Clinical Trial Identifier: NCT03563313.
Prospective Longitudinal Study Evaluating Comprehensive Metabolic and Life Style Characteristics of Pancreas Transplantation Recipients
Kaur, Ravinder Jeet , Rizvi, Shafaq R., Reid, Corey, McCrady-Spitzer, Shelly , Dean, Patrick G. , Kukla, Aleksandra , Kudva, Yogish C. , Rizvi, Shafaq, Stegall, Mark D.

Mayo Clinic

Journal of the Endocrine Society | May 3, 2021 | Volume: 5 | Issue: Supplement_1 | Pages: A461-A461

10.1210/jendso/bvab048.941 Get It

Abstract Introduction: Pancreas Transplantation (PT) improves quality of life in Type 1 Diabetes (T1D) patients but limited longitudinal data are available regarding comprehensive metabolic assessment and lifestyle. Our objective was to comprehensively assess T1D patients who underwent PT (PTA and SPK) ≥ 1 year prior on two separate visits 1 year apart. Methodology: We studied 12 PT recipients ≥1 year post PT. Two assessments 1 year apart included comprehensive assessment of graft function using standard mixed meal tolerance test (MMTT), Continuous Glucose Monitoring (CGM) for 1 week, body composition using DEXA scan, physical activity using ActiGraph for 1 week and dietary assessment by VIOCARE®. Results: PT recipients (9F) were 55.5± 9.7 years old, 91.7 % Caucasian with 34.9 ± 12.3 years of diabetes, 6.7 ± 5.2 years (range-1.3–17.6 years) after PT. Ten participants underwent Pancreas Transplantation alone and two received Simultaneous Pancreas Kidney transplantation. Visit 1(V1) showed HbA1c 5.5 ± 0.7%, Fructosamine 238.4 ± 25.6 mcmol/L, BMI 31.2 ± 6.7 kg/m2, fasting plasma glucose (FPG) 95.2 ± 19.4mg/dL and C-peptide 2.6 ± 1.0 ng/ml and visit 2 (V2) HbA1c 5.5 ± 0.6%, Fructosamine 244.4 ± 41.3 mcmol/L, BMI 29.9 ± 5.1kg/m2, FPG 95.4 ± 27.7mg/dL, and C-peptide 2.5 ± 0.8 ng/ml (p-value not significant). One week CGM (n=9) showed excellent glucose control at both visits with mean glucose 117.8 ± 7.0 vs.112 ± 6.2 mg/dl and 96.3 ± 3.6 vs. 96.9±2.8 % time in target range (70-180mg/dl). Time >180mg/dl and >250mg/dl were 2.7 ± 3.0 vs. 1.3±1.7 % (p=0.0413) and 0.2 ± 0.6 vs. 0.1 ± 0.1 % respectively. Mild CGM hypoglycemia (<70 mg/dl) was observed during both visits (1.0 ± 1.0 vs. 1.7± 2 %). CV was 21.1 ± 5.5 and 20.1 ± 4.8 %. Eight recipients underwent MMTT and showed excellent response to Boost® with no significant difference between visits with exception of insulin concentrations at 60 mins (increased from V1) and 90 mins (decreased from V1) (p=0.0424 and 0.0235). DEXA (n=10) revealed similar total % mean fat, and fat distribution in arms, legs and trunk. ActiGraph (n=10) showed similar physical activity during both visits with 16761 ± 5176 and 14499 ± 4192 average steps/day respectively. Mean MET score was 1.6 ± 0.4 and 1.6 ± 0.2 indicating light intensity activity during both periods. Total mean sedentary bouts increased over 1 year (49.6 ± 39.1 vs. 60.8 ± 43.7, p=0.0038). Dietary assessment in 11 recipients showed no significant difference in dietary intake with calories intake 1.3± 0.4 vs. 1.2±0.5 daily Harris-Benedict and macronutrient intake with fat of 36.7 ± 4.3 % and 36.5 ± 5.7 %, CHO of 45.7 ± 5.5 % and 45.7 ± 5.5 % and Omega-3 of 0.1 ± 0.1 g and 0.05 ± 0.1 g respectively. Conclusion: PT recipients have excellent glucose control and pancreas graft function 1 or more years after PT when assessed over successive 2 years with suboptimal body composition and dietary intake and above average physical activity.
Closed-Loop Insulin Therapy Improves Glycemic Control in Adolescents and Young Adults: Outcomes from the International Diabetes Closed-Loop Trial
Isganaitis, Elvira , Raghinaru, Dan, Ambler-Osborn, Louise, Pinsker, Jordan E. , Buckingham, Bruce A. , Ekhlaspour, Laya , Kudva, Yogish C., Forlenza, Gregory P. , Beck, Roy W., Kollman, Craig, Lum, John W. , Brown, Sue A. , Laffel, Lori M. , Kovatchev, Boris, Anderson, Stacey, Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc, Flint, Emily, Kim, Kenny, Roethke, Lindsay, Church, Mei Mei , André, Camille , Piper, Molly, Lam, David , O’Malley, Grenye , Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Alonso, G. Todd, Slover, Robert H., Jost, Emily , Berget, Cari, Towers, Lindsey, Rossick-Solis, Alex, Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Dassau, Eyal , Passman, Samantha, Campos, Tiffany, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreaza-Rubín, Guillermo , Green, Neal, Laffel, Lori, Pinsker, Jordan, Doyle, Francis, Renard, Eric, Reznik, Yves , Lum, John, Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Green, Jennifer , Legault, Laurent , Wysham, Carol , Eggerman, Thomas, Forlenza, Gregory P , Buckingham, Bruce , Wadwa, R Paul , Kudva, Yogish C. , Levy, Carol J. , Kollman, Craig , Kovatchev, Boris , Anderson, Stacey M. , Oliveri, Mary Clancy , Kumari, Kanchan , Messer, Laurel H , Jacobson, Tali, Doyle, Francis J. , Patibandla, Nandan, Laffel, Lori M. , Cobelli, Claudio , Beck, Roy W. , Willi, Steven Matthew

Mayo Clinic

Diabetes Technology & Therapeutics | November 20, 2020 | Volume: 23 | Issue: 5 | Pages: 342-349

10.1089/dia.2020.0572 | PMID 33216667 Get It

Objective: To assess the efficacy and safety of closed-loop control (CLC) insulin delivery system in adolescents and young adults with type 1 diabetes. Research Design and Methods: Prespecified subanalysis of outcomes in adolescents and young adults aged 14–24 years old with type 1 diabetes in a previously published 6-month multicenter randomized trial. Participants were randomly assigned 2:1 to CLC (Tandem Control-IQ) or sensor augmented pump (SAP, various pumps+Dexcom G6 CGM) and followed for 6 months. Results: Mean age of the 63 participants was 17 years, median type 1 diabetes duration was 7 years, and mean baseline HbA1c was 8.1%. All 63 completed the trial. Time in range (TIR) increased by 13% with CLC versus decreasing by 1% with SAP (adjusted treatment group difference = +13% [+3.1 h/day]; 95% confidence interval [CI] 9–16, P < 0.001), which largely reflected a reduction in time >180 mg/dL (adjusted difference −12% [−2.9 h/day], P < 0.001). Time <70 mg/dL decreased by 1.6% with CLC versus 0.3% with SAP (adjusted difference −0.7% [−10 min/day], 95% CI −1.0% to −0.2%, P = 0.002). CLC use averaged 89% of the time for 6 months. The mean adjusted difference in HbA1c after 6 months was 0.30% in CLC versus SAP (95% CI −0.67 to +0.08, P = 0.13). There was one diabetic ketoacidosis episode in the CLC group. Conclusions: CLC use for 6 months was substantial and associated with improved TIR and reduced hypoglycemia in adolescents and young adults with type 1 diabetes. Thus, CLC has the potential to improve glycemic outcomes in this challenging age group. The clinical trial was registered with ClinicalTrials.gov (NCT03563313).
Clinical Management and Pump Parameter Adjustment of the Control-IQ Closed-Loop Control System: Results from a 6-Month, Multicenter, Randomized Clinical Trial
O’Malley, Grenye , Messer, Laurel H. , Pinsker, Jordan E. , Forlenza, Gregory P. , Isganaitis, Elvira , Kudva, Yogish C. , Ekhlaspour, Laya , Raghinaru, Dan, Lum, John W. , Brown, Sue A. , Kovatchev, Boris, Anderson, Stacey M. , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Laffel, Lori M. , E.I., Ambler-Osborn, Louise, Flint, Emily, Kim, Kenny, Roethke, Lindsay, J.E.P., Church, Mei Mei , André, Camille , Piper, Molly, C.J.L., Lam, David W. , G.O., Levister, Camilla, Ogyaadu, Selassie, Lovett, Jessica, Simha, Vinaya , Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Wadwa, R. Paul, Alonso, G. Todd, Slover, Robert H., Jost, Emily , L.H.M., Berget, Cari, Towers, Lindsey, Rossick-Solis, Alex, Buckingham, Bruce, L.E., Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Paulson, John A., Beck, Jan-Philipp, Passman, Samantha, Campos, Tiffany, Kollman, D.R. Craig, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreza-Rubin, Guillermo, Eggerman, Thomas L., Green, Neal, Kovatchev, Boris, Arreza-Rubin, Guillermo, J.E.P., C.J.L., Y.C.K., Wadwa, R. Paul, Reznik, Yves , Arreza-Rubin, Guillermo, Buckingham, Bruce A. , Forlenza, Gregory P , Messer, Laurel H , Buckingham, Bruce , Levy, Carol J. , Pinsker, Jordan E. , Kovatchev, Boris , Kovatchev, Boris, Oliveri, Mary Clancy , E.I., J.E.P., C.J.L., G.O., Wadwa, R Paul , Kumari, Kanchan , Wadwa, R. Paul, L.H.M., L.E., Town, Marissa, Paulson, John A., Patibandla, Nandan, Arreza-Rubin, Guillermo, Kovatchev, Boris, Arreza-Rubin, Guillermo, J.E.P., C.J.L., Y.C.K., Wadwa, R. Paul, Renard, Eric , Cobelli, Claudio , Arreza-Rubin, Guillermo

Mayo Clinic

Diabetes Technology & Therapeutics | November 6, 2020 | Volume: 23 | Issue: 4 | Pages: 245-252

10.1089/dia.2020.0472 | PMID 33155824 Get It

Background: Data are limited on the need for and benefits of pump setting optimization with automated insulin delivery. We examined clinical management of a closed-loop control (CLC) system and its relationship to glycemic outcomes. Materials and Methods: We analyzed personal parameter adjustments in 168 participants in a 6-month multicenter trial of CLC with Control-IQ versus sensor-augmented pump (SAP) therapy. Preset parameters (BR = basal rates, CF = correction factors, CR = carbohydrate ratios) were optimized at randomization, 2 and 13 weeks, for safety issues, participant concerns, or initiation by participants' usual diabetes care team. Time in range (TIR 70–180 mg/dL) was compared in the week before and after parameter changes. Results: In 607 encounters for parameter changes, there were fewer adjustments for CLC than SAP (3.4 vs. 4.1/participant). Adjustments involved BR (CLC 69%, SAP 80%), CR (CLC 68%, SAP 50%), CF (CLC 44%, SAP 41%), and overnight parameters (CLC 62%, SAP 75%). TIR before and after adjustments was 71.2% and 71.3% for CLC and 61.0% and 62.9% for SAP. The highest baseline HbA 1c CLC subgroup had the largest TIR improvement (51.2% vs. 57.7%). When a CR was made more aggressive in the CLC group, postprandial time >180 mg/dL was 43.1% before the change and 36.0% after the change. The median postprandial time <70 mg/dL before making CR less aggressive was 1.8%, and after the change was 0.7%. Conclusions: No difference in TIR was detected with parameter changes overall, but they may have an effect in higher HbA 1c subgroups or following user-directed boluses, suggesting that changes may matter more in suboptimal control or during discrete periods of the day. Clinical Trials Registration number: NCT03563313.
Use of the Interoperable Artificial Pancreas System for Type 1 Diabetes Management During Psychological Stress
Pinsker, Jordan E. , McCrady-Spitzer, Shelly , Church, Mei Mei , Kaur, Ravinder Jeet , Pérez, Jimena, Desjardins, Donna, Piper, Molly, Reid, Corey, Kudva, Yogish C. , Dassau, Eyal , Dassau, Eyal , Deshpande, Sunil , Perez, Jimena, Doyle, Francis J.

Mayo Clinic

Journal of Diabetes Science and Technology | August 12, 2020 | Volume: 15 | Issue: 1 | Pages: 184-185

10.1177/1932296820948566 | PMID 32783473 Get It

Glycemic Outcomes of Use of CLC Versus PLGS in Type 1 Diabetes: A Randomized Controlled Trial
Brown, Sue A. , Beck, Roy W. , Raghinaru, Dan, Buckingham, Bruce A. , Laffel, Lori M. , Kudva, Yogish C. , Pinsker, Jordan E. , Dassau, Eyal , Ambler-Osborn, Louise, Anderson, Stacey M. , Church, Mei Mei , Ekhlaspour, Laya , Forlenza, Gregory P. , Levister, Camilla, Simha, Vinaya , Breton, Marc D. , Kollman, Craig, Lum, John W. , Kovatchev, Boris , Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Gondor-Fredrick, Linda, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Isganaitis, Elvira , Flint, Emily, Kim, Kenny, Roethke, Lindsay, André, Camille , Piper, Molly, Lam, David W. , O’Malley, Grenye , Ogyaadu, Selassie, Lovett, Jessica, Dadlani, Vikash, McCrady-Spitzer, Shelly , Reid, Corey, Slover, Robert H., Jost, Emily , Berget, Cari , Towers, Lindsey, Rossick-Solis, Alex, Jacobson, Tali, Town, Marissa, Tabatabai, Ideen , Keller, Jordan, Salas, Evalina, Passman, Samantha, Campos, Tiffany, Murphy, Carlos, Patibandla, Nandan, Borgman, Sarah, Arreza-Rubin, Guillermo, Eggerman, Thomas L., Green, Neal, Reznik, Yves , Janicek, Robert, Gabrielson, Deanna, Belle, Steven H., Castle, Jessica R. , Legault, Laurent , Wysham, Carol , Kudva, Yogish C. , Pinsker, Jordan E , Dassau, Eyal , Doyle, Francis J , Ekhlaspour, Laya , Forlenza, Gregory P , Breton, Marc D , Lum, John , Kovatchev, Boris , Buckingham, Bruce , Beck, Roy W , Wadwa, R Paul , Levy, Carol J. , Doyle, Francis J. , Kollman, Craig , Oliveri, Mary Clancy , Kumari, Kanchan , Alonso, G. Todd , Messer, Laurel H , Renard, Eric , Cobelli, Claudio , Green, Jennifer Greif , Willi, Steven Matthew

Mayo Clinic

Diabetes Care | May 30, 2020 | Volume: 43 | Issue: 8 | Pages: 1822-1828

10.2337/dc20-0124 | PMID 32471910 Get It

OBJECTIVE Limited information is available about glycemic outcomes with a closed-loop control (CLC) system compared with a predictive low-glucose suspend (PLGS) system. RESEARCH DESIGN AND METHODS After 6 months of use of a CLC system in a randomized trial, 109 participants with type 1 diabetes (age range, 14–72 years; mean HbA1c, 7.1% [54 mmol/mol]) were randomly assigned to CLC (N = 54, Control-IQ) or PLGS (N = 55, Basal-IQ) groups for 3 months. The primary outcome was continuous glucose monitor (CGM)-measured time in range (TIR) for 70–180 mg/dL. Baseline CGM metrics were computed from the last 3 months of the preceding study. RESULTS All 109 participants completed the study. Mean ± SD TIR was 71.1 ± 11.2% at baseline and 67.6 ± 12.6% using intention-to-treat analysis (69.1 ± 12.2% using per-protocol analysis excluding periods of study-wide suspension of device use) over 13 weeks on CLC vs. 70.0 ± 13.6% and 60.4 ± 17.1% on PLGS (difference = 5.9%; 95% CI 3.6%, 8.3%; P &lt; 0.001). Time &gt;180 mg/dL was lower in the CLC group than PLGS group (difference = −6.0%; 95% CI −8.4%, −3.7%; P &lt; 0.001) while time &lt;54 mg/dL was similar (0.04%; 95% CI −0.05%, 0.13%; P = 0.41). HbA1c after 13 weeks was lower on CLC than PLGS (7.2% [55 mmol/mol] vs. 7.5% [56 mmol/mol], difference −0.34% [−3.7 mmol/mol]; 95% CI −0.57% [−6.2 mmol/mol], −0.11% [1.2 mmol/mol]; P = 0.0035). CONCLUSIONS Following 6 months of CLC, switching to PLGS reduced TIR and increased HbA1c toward their pre-CLC values, while hypoglycemia remained similarly reduced with both CLC and PLGS.
SAT-641 Self-Reported Psychological Stress and Glucose Variability in Type 1 Diabetes on Sensor Augmented Pump over 5 Weeks
Kaur, Ravinder Jeet , Pinsker, Jordan E. , Dadlani, Vikash, Thapa, Prabin , Batthula, Sreedhar, Church, Mei Mei , Reid, Corey, Spitzer, Shelly McCrady, Dassau, Eyal , Kudva, Yogish C. , Kremers, Walter K.

Mayo Clinic

Journal of the Endocrine Society | May 8, 2020 | Volume: 4 | Issue: Supplement_1 | Pages: No page available

10.1210/jendso/bvaa046.1879 Get It

Abstract Introduction: Patients and their families and medical providers have assumed that psychologic stress impacts glucose control in T1D (Type 1 Diabetes) though studies providing confirmatory evidence in real world settings are, to our knowledge, lacking. We hypothesized that self-reported psychologic stress worsens glucose control in T1D. Method: We studied 20 adults with T1D on continuous glucose monitor (CGM), sensor augmented insulin pump (SAP) prospectively at 2 clinical research centers. Patients reported psychological stress through stress diaries for 5 weeks on a severity scale of 1-7 using hard copy logs including time of onset and offset of stress and severity. For analytic purpose, grades 1-4 are classified as mild and grades 5-7 as severe. Results: Baseline characteristics were age 44.9±15.0 years, F/M 12/8, HbA1c 6.8 ± 0.7%, and diabetes duration of 22.9±15.9 years. We analyzed glucose variability during days of stress versus days without stress. During a 24 hour period, patients experienced less hypoglycemia during days with stress versus days without stress (p value 0.03). During the 5 week period, patients reported 23 ± 19.5 events. We analyzed the impact of self-reported stress on CGM data streams after excluding stress events associated with missing CGM data, nocturnal events (from 12 MN to 6 AM, too few events) and events for which subjects did not provide duration of stress. Thus, we analyzed 19.5 ± 17 events per patient from 6AM to 12MN. From 6 AM to 12 MN, the episodes lasted 179 ± 255 minutes with 83 % episodes being mild/moderate and 17% moderate/ severe. Number of CGM readings during daytime stress episodes were 717± 1120 compared to 8768± 1238 during non-stress periods. Impact of stress from 6 AM to 12 MN (Mid-Night) on CGM glucose was analyzed using matched paired t test. Mean glucose (160.6±41.9 vs 148.3± 28.6) and SD (53.2 ±17.7 vs 56.1±14.6) did not show a difference; however % of time spent below 70 mg/dl was less (4 ± 5) in patients during stressful periods compared to times without stress (6.3± 5.5, P value 0.02). Conclusions: To our knowledge, this is the first study attempting to analyze the impact of self-reported stress using daily stress diaries on CGM data streams in T1D patients on SAP. The study revealed significant challenges experienced by patients in reporting adequate data. Self-reported stress was not associated with hyperglycemia. However, days of self-reported stress and periods during patients reported stress were characterized by less hypoglycemia on CGM data streams.
Randomized Controlled Trial of Mobile Closed-Loop Control
Kovatchev, Boris , Anderson, Stacey M. , Raghinaru, Dan, Kudva, Yogish C. , Laffel, Lori M. , Pinsker, Jordan E. , Buckingham, Bruce A. , Doyle, Francis J. , Brown, Sue A. , Church, Mei Mei , Dadlani, Vikash, Dassau, Eyal , Ekhlaspour, Laya , Forlenza, Gregory P. , Isganaitis, Elvira , Lam, David W. , Lum, John W. , Group, iDCL Study, Emory, Emma, Voelmle, Mary, Conshafter, Katie, Morris, Kim, Mitchell, Harry, Calvo, Kayla, Wakeman, Christian, Breton, Marc D. , Ambler-Osborn, Louise, Flint, Emily, Schultz, Alan , Kim, Kenny, Church, Mei Mei, André, Camille , Lam, David W., O’Malley, Grenye , Levister, Camilla, Ogyaadu, Selassie, Simha, Vinaya , McCrady-Spitzer, Shelly , Reid, Corey, Jost, Emily , Berget, Cari , Towers, Lindsey, Buckingham, Bruce, Ekhlaspour, Laya, Hsu, Liana, Loebner, Sarah E., Doyle, Francis J., Campos, Tiffany, Passman, Samantha, Murphy, Carlos, Patibandla, Nandan, Kollman, Craig, Pinsker, Jordan E , Doyle, Francis J , Dassau, Eyal , Ekhlaspour, Laya , Forlenza, Gregory P , Lum, John , Kovatchev, Boris , Buckingham, Bruce , Levy, Carol J. , Wadwa, R Paul , Beck, Roy W. , Group, iDCL Study, Oliveri, Mary Clancy , Church, Mei Mei, Lam, David W., Messer, Laurel H , Buckingham, Bruce, Ekhlaspour, Laya, Doyle, Francis J., Kollman, Craig

Mayo Clinic

Diabetes Care | January 15, 2020 | Volume: 43 | Issue: 3 | Pages: 607-615

10.2337/dc19-1310 | PMID 31937608 Get It

OBJECTIVE Assess the efficacy of inControl AP, a mobile closed-loop control (CLC) system. RESEARCH DESIGN AND METHODS This protocol, NCT02985866, is a 3-month parallel-group, multicenter, randomized unblinded trial designed to compare mobile CLC with sensor-augmented pump (SAP) therapy. Eligibility criteria were type 1 diabetes for at least 1 year, use of insulin pumps for at least 6 months, age ≥14 years, and baseline HbA1c &lt;10.5% (91 mmol/mol). The study was designed to assess two coprimary outcomes: superiority of CLC over SAP in continuous glucose monitor (CGM)–measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L. RESULTS Between November 2017 and May 2018, 127 participants were randomly assigned 1:1 to CLC (n = 65) versus SAP (n = 62); 125 participants completed the study. CGM time below 3.9 mmol/L was 5.0% at baseline and 2.4% during follow-up in the CLC group vs. 4.7% and 4.0%, respectively, in the SAP group (mean difference −1.7% [95% CI −2.4, −1.0]; P &lt; 0.0001 for superiority). CGM time above 10 mmol/L was 40% at baseline and 34% during follow-up in the CLC group vs. 43% and 39%, respectively, in the SAP group (mean difference −3.0% [95% CI −6.1, 0.1]; P &lt; 0.0001 for noninferiority). One severe hypoglycemic event occurred in the CLC group, which was unrelated to the study device. CONCLUSIONS In meeting its coprimary end points, superiority of CLC over SAP in CGM-measured time below 3.9 mmol/L and noninferiority in CGM-measured time above 10 mmol/L, the study has demonstrated that mobile CLC is feasible and could offer certain usability advantages over embedded systems, provided the connectivity between system components is stable.
Accuracy of Accelerometers for Measuring Physical Activity and Levels of Sedentary Behavior in Children: A Systematic Review
Lynch, Brian , Kaufman, Tara K. , Rajjo, Tamim , Mohammed, Khaled , Kumar, Seema, Murad, M. Hassan , Gentile, Natalie, Koepp, Gabriel A., McCrady-Spitzer, Shelly , Levine, James A. , Lynch, Brian A , Rajjo, Tamim I, Gentile, Natalie E, Murad, M Hassan

Mayo Clinic

Journal of Primary Care & Community Health | September 11, 2019 | Volume: 10 | Issue: No issue available | Pages: No page available

10.1177/2150132719874252 | PMID 31509061 Get It

Objectives: This systematic review evaluated the accuracy of triaxial and omnidirectional accelerometers for measuring physical activity and sedentary behavior in children. Design: Systematic review of the literature. Methods: We comprehensively searched several databases for studies published from January 1996 through June 2018 that reported diagnostic accuracy measures in children and adolescents (age 3-18 years) and compared accelerometers with energy expenditure using indirect calorimetry. Results: We included 11 studies that enrolled 570 participants. All studies used indirect calorimetry as the reference standard. Across the studies, median sensitivity ranged from 46% to 96% and median specificity ranged from 71% to 96%. Median area under the curve ranged from 69% to 98%. Conclusions: Accuracy measures were greatest when detecting sedentary behavior and lowest when detecting light physical activity. Accuracy was higher when the accelerometer was placed on the hip compared with the wrist. The current evidence suggests that triaxial and omnidirectional accelerometers are accurate in measuring sedentary behavior and physical activity levels in children.