Citations

Clear

15 citation(s) found for "Khalil, Fouad".

Response to Letter to the Editor regarding ‘Characteristics and outcomes of ventricular tachycardia and premature ventricular contractions ablation in patients with prior mitral valve surgery’
Khalil, Fouad , Killu, Ammar M. , Khalil, Fouad

Mayo Clinic

No container title available | April 6, 2022 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.164922306.68091730/v1 Get It

We would like to thank the authors for their letter and interest in our manuscript. We appreciate their valuable comments. The authors have raised the following important points: 1. The heterogenicity of our cohort with mitral valve surgery (MVS) 2. Elucidating the characteristics and causes of ventricular arrhythmias (VA) in patients with primary versus secondary mitral disease as well as in those with ischemic versus non-ischemic heart disease 3. The paucity of cardiac magnetic resonance imaging (MRI) as a limitation of the study 4. The need for careful evaluation of patients prior to ablation since most arrhythmias did not originate from the perimitral area.
Characteristics and outcomes of ventricular tachycardia and premature ventricular contractions ablation in patients with prior mitral valve surgery
Khalil, Fouad , Madhavan, Malini , Ahmad, Ali , Mulpuru, Siva K. , Siontis, Konstantinos C. , Deshmukh, Abhishek , Cha, Yong‐Mei , Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Killu, Ammar M. , Madhavan, Malini , Kapa, Suraj , Mulpuru, Siva K , Siontis, Konstantinos C , Deshmukh, Abhishek J , Friedman, Paul A , Munger, Thomas, Asirvatham, Samuel J , Killu, Ammar M , Khalil, Fouad , Toya, Takumi , Badawy, Mohamed, Kapa, Suraj , DeSimone, Christopher V.

Mayo Clinic

Journal of Cardiovascular Electrophysiology | December 15, 2021 | Volume: 33 | Issue: 2 | Pages: 274-283

10.1111/jce.15331 | PMID 34911151 Get It

AbstractBackgroundData regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following mitral valve surgery (MVS) is limited. Catheter ablation (CA) can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves.ObjectiveTo investigate the characteristics, safety, and outcomes of radiofrequency CA in patients with prior MVS and ventricular arrhythmias (VA).MethodsWe identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013 and December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri‐operative complications, and outcomes.ResultsIn our cohort, 31 patients (77% men, mean age 62.3 ± 10.8 years, left ventricular ejection fraction 39.2 ± 13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans‐septal approach in one patient. Heterogenous scar regions were present in 94% of VT patients and scar‐related reentry was the dominant mechanism of VT. Forty‐seven percent of PVC patients had abnormal substrate at the site targeted for ablation. Clinical VA substrates involved the peri‐mitral area in six patients with VT and five patients with PVC ablation. No procedure‐related complications were reported. The overall recurrence‐free rate at 1‐year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia‐related death was documented on long‐term follow‐up.ConclusionCA of VAs can be performed safely and effectively in patients with MVS.
Characteristics and Outcomes of Ventricular Tachycardia and Premature Ventricular Contractions Ablation in Patients with Prior Mitral Valve Surgery
Khalil, Fouad , Madhavan, Malini , Badawy, Mohammed, Kapa, Suraj , Mulpuru, Siva K. , Siontis, Konstantinos C. , DeSimone, Christopher V. , Deshmukh, Abhishek , Cha, Young-mei, Friedman, Paul A. , Munger, Thomas M. , Killu, Ammar M. , Khalil, Fouad , Kapa, Suraj , DeSimone, Christopher V , Toya, Takumi , Badawy, Mohammed, Asirvatham, Samuel J.

Mayo Clinic

No container title available | July 2, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.162524921.19356960/v1 Get It

Background: Data regarding ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation following MVS is limited.) CA can be challenging given perivalvular substrate in the setting of mitral annuloplasty or prosthetic valves. Objective: To investigate the characteristics, safety, and outcomes of radiofrequency catheter ablation (CA) in patients with prior mitral valve surgery (MVS) and ventricular arrhythmias (VA). Methods: We identified consecutive patients with prior MVS who underwent CA for VT or PVC between January 2013- December 2018. We investigated the mechanism of arrhythmia, ablation approach, peri-operative complications, and outcomes. Results: In our cohort of 31 patients (77% men, mean age 62.3±10.8 years, left ventricular ejection fraction 39.2±13.9%) with prior MVS underwent CA (16 VT; 15 PVC). Access to the left ventricle was via transseptal approach in 17 patients, and a retrograde aortic approach was used in 13 patients. A combined transseptal and retrograde aortic approach was used in one patient, and a percutaneous epicardial approach was combined with trans-septal approach in 1patient. Heterogenous scar regions were present in 94% of VT patients and scar-related reentry was the dominant mechanism of VT. Clinical VA substrates involved the peri-mitral area in 6 patients with VT and 5 patients with PVC ablation. No procedure-related complications were reported. The overall recurrence-free rate at 1-year was 72.2%; 67% in the VT group and 78% in the PVC group. No arrhythmia-related death was documented on long-term follow-up. Conclusion: CA of VAs can be performed safely and effectively in patients with MVS
Utilization and procedural adverse outcomes associated with Watchman device implantation
Khalil, Fouad , Arora, Shilpkumar , Killu, Ammar M. , Egbe, Alexander C. , Kapa, Suraj , Mulpuru, Siva K. , Mohamad, Alkhouli, Friedman, Paul A. , Holmes, David R. , Deshmukh, Abhishek , Mulpuru, Siva, Khalil, Fouad , Kapa, Suraj , Tripathi, Byomesh , DeSimone, Christopher V. , Noseworthy, Peter A. , Gersh, Bernard J.

Mayo Clinic

EP Europace | August 9, 2020 | Volume: 23 | Issue: 2 | Pages: 247-253

10.1093/europace/euaa219 | PMID 32929501 Get It

AbstractAims The Food and Drug Administration (FDA) approval of the Watchman device [percutaneous left atrial appendage occlusion (LAAO)] has resulted in the widespread use of this procedure in many centres across the USA. We sought to estimate the nationwide utilization and frequency of adverse outcomes associated with Watchman device implantation. The objective of this study was to evaluate the Watchman device implantation peri-procedural complications and comparison of the results with the previous studies.Methods and results The National Inpatient Sample (NIS) was queried for all hospitalizations with a primary diagnosis of atrial fibrillation or atrial flutter during the year 2016 with percutaneous LAAO during the same admission (ICD-10 code—02L73DK). The frequency of peri-procedural complications, including mortality, procedure-related stroke, major bleeding requiring blood transfusion, and pericardial effusion, was assessed. We compared the complication rates with the published randomized controlled trials and the European Watchman registry. An estimated 5175 LAAO procedures were performed in 2016. The majority of procedures was performed in males (59.1%), age ≥75 years (58.7%), and White (83.1%). The overall complication rate was 1.9%. The in-hospital mortality was 0.29%. Pericardial effusion requiring pericardiocentesis was the most frequent complication (0.68%). Bleeding requiring transfusion was noted in 0.1% of device implants. The rates of post-procedure stroke and systemic embolism were 0% and 0.29%, respectively.Conclusion Percutaneous LAAO with the Watchman device in the USA is associated with low in-hospital complications and a similar safety profile to a recently published EWOLUTION cohort. The complication rates were lower than those reported in the major randomized clinical trials (RCTs). We report the frequency of peri-procedural complications of the LAAO using the Watchman device from the NIS database. We also compare the frequency of peri-procedural complications with the previously published RCTs and EWOLUTION cohort. Our findings are in concordance with findings from EWOLUTION cohort and compare favourably with RCTs.
Left ventricular pacing induced polymorphic ventricular tachycardia via the adaptive left ventricle pacing algorithm
Khalil, Fouad , Munoz, Freddy Del‐Carpio , Deshmukh, Abhishek , Killu, Ammar M. , Del-Carpio Munoz, Freddy , Khalil, Fouad

Mayo Clinic

Clinical Case Reports | May 27, 2020 | Volume: 8 | Issue: 8 | Pages: 1511-1516

10.1002/ccr3.2940 | PMID 32884785 Get It

AbstractProviders should be aware of the possibility of cardiac resynchronization therapy‐related proarrhythmia which could be life‐threatening. His‐bundle pacing may serve as an alternative, more physiological, option in the management as it preserves the normal sequence of depolarization from the septum to the lateral wall, and from endocardium to epicardium.