Citations

Clear

635 citation(s) found for "Holmes, D R".

Earlier CRS identification with continuous wearable monitoring in outpatient CAR T-cell therapy.
Paludo, Jonas, Pettinati, Michael, Guo, Christine, Ruff, Michael W. , Holmes, Lucy , Haugen, Kelsey L., Amundson, Michelle, Khurana, Arushi , Bennani, Nabila Nora, Wang, Yucai, Kourelis, T., Kumar, Shaji, Kapoor, Prashant , Abdallah, Nadine, Ansell, Stephen M., Haddad, Tufia C. , Lin, Yi, Paludo, Jonas , Pettinati, Michael J. , Pritchett, Joshua C. , Holmes, Lucy M., Haugen, Kelsey, Kourelis, Taxiarchis , Kumar, Shaji , Binder, Moritz , Abdallah, Nadine , Ansell, Stephen M. , Routman, David M.

Mayo Clinic

Journal of Clinical Oncology | May 27, 2026 | Volume: 44 | Issue: 16_suppl | Pages: 1633-1633

10.1200/jco.2026.44.16_suppl.1633 Get It

1633 Background: CAR-T cell therapy has transformed outcomes of hematologic malignancies and is poised to expand into solid malignancies. However, broader use of CAR-T remains constrained by the need for timely cytokine release syndrome (CRS) detection. Current episodic monitoring may miss early physiologic changes. Wearable digital health technologies (DHTs), offering continuous monitoring and real-time alerts, could enable earlier CRS detection, further support outpatient delivery, and expand access to CAR-T and potentially other immunotherapies associated with CRS. Methods: This single-center observational study (NCT05018208) enrolled patients receiving FDA-approved CAR-T products in the outpatient setting at Mayo Clinic, Rochester MN. Management of post-CAR-T complications (e.g. CRS) followed the institution’s standard of care. Patients were monitored from day -5 to day +30 post infusion with intermittent remote patient monitoring (SoC) and an arm-worn wearable device for continuous monitoring (DHT). Patients were included in this analysis if DHT data were available for ≥ 5h of data/day or ≥ 2h of data/night on ≥2 days or nights for baseline and ≥1 day or night within 72h prior to CRS, or at least 2h within 4h of CRS onset, or if DHT was available for ≥7 days/nights post infusion with no CRS event. CRS detection time by DHT was defined as the onset of pyrexia or threshold-based deviation from an individual’s baseline pulse distributions. Results: 32 patients were included in this report (median age 64 years, gender 12 F/20 M, diagnoses 18 MM/14 NHL). 25 patients experienced a CRS event, with maximum CRS grades ranging from 1-3 (16 G1, 8 G2, 1 G3). 24/25 patients with CRS required tocilizumab/steroid. Median CRS onset time was 3.4 days (range 0.4-18.4). 12/32 patients had sufficient DHT data (7 CRS, 5 no CRS) for analysis. 5 patients with CRS had a DHT detection time in advance of the SoC by a median of 13h (range 2.8 - 69.2). The DHT prediction of CRS by baseline HR change was earlier than the first episodic fever by a median of 14.5h (range 13-77.5). The remaining 2/7 patients who did not have CRS detected by the DHT had missing DHT data for more than 45h before a treated CRS event. DHT detected CRS in 2/5 patients without CRS according to SoC. One patient had fever caught with intermittent monitoring. The other was treated for neutropenia fever with suspicion of CRS and/or infection. Conclusions: These results offer evidence that continuous DHT can identify CRS events earlier than intermittent monitoring (SoC). Despite limitations related to compliance with wearable device use and data missingness, and variability in clinical management of CRS, we highlight the usability of DHT and its potential for future studies with optimized strategies to address these limitations. Clinical trial information: NCT05018208 .
Noisy probing dose facilitated dose prediction for pencil beam scanning proton therapy: Physics enhances generalizability
Zhang, Lian , Zhang, Xiao, Li, Mingzhu, Vargas, Carlos , Keole, Sameer R., Stützer, Kristin , Liu, Tianming , Wong, William W. , Vora, Sujay A., Feng, Hongying , Holmes, Jason , Zhang, Xiao, Liu, Zhengliang , Li, Mingzhu, Sio, Terence T. , Li, Sheng , Shen, Jiajian , Liu, Wei

Mayo Clinic

Medical Physics | May 27, 2026 | Volume: 53 | Issue: 5 | Pages: No page available

10.1002/mp.70509 | PMID 42192246 Get It

Abstract Background Accurate and efficient dose calculation is essential for online adaptive planning in proton therapy. Deep learning (DL) has shown promising dose prediction results for pencil beam scanning proton therapy (PBSPT) in recent years, but existing DL‐based dose prediction methods still suffer from limited generalizability and an inability to effectively handle outlier clinical cases. This may lead to inaccurate dose delivery to targets or excessive irradiation to organs at risk (OARs), thereby compromising the safety and efficacy of online adaptive proton therapy. Purpose To design a physics‐aware and generalizable AI‐based PBSPT dose prediction method that incorporates underlying physics to enhance generalizability, particularly in handling outlier clinical cases. Methods This study analyzed PBSPT plans of 103 prostate (93 for training and 10 for testing) and 78 lung cancer patients (68 for training and 10 for testing) from our institution, with each case comprising CT images and structure sets. Using the doses generated by our Monte Carlo‐based dose engine as the reference standard, we compared three methods: the region of interest (ROI)‐based method, the beam mask and sliding window method, and the proposed noisy probing dose method, which rapidly generates a low‐statistics dose via uniformly weighted spots on an expanded spot‐placement target volume without optimization. To evaluate the generalizability of these methods to rare treatment planning scenarios, 12 cases with uncommon beam angles or prescription doses were used to assess their performance, which was evaluated using dose‐volume histogram (DVH) indices, 3D Gamma passing rates (3%/2 mm/10%), and Dice coefficients for dose agreement, while prediction times were measured to gauge model efficiency. Results The proposed noisy probing dose method consistently outperformed the ROI‐based and beam mask baselines across all evaluated metrics, with more accurate dose agreement and superior generalizability. For DVH indices, the noisy probing dose method achieved the smallest deviation in clinical target volume (CTV) dose coverage: in prostate cancer, CTV D98 deviation was reduced by 45% (from 0.53 ± 0.22 Gy [RBE] for ROI‐based) and 29% (from 0.41 ± 0.28 Gy [RBE] for beam mask) to 0.29 ± 0.06 Gy [RBE]; in lung cancer, similar improvements were observed, with CTV D98 deviations reduced to 0.34 ± 0.12 Gy [RBE]. The 3D Gamma passing rates improved to 99.65% ± 1.15% for prostate targets and 97.04% ± 1.17% for lung targets. The dice coefficients of the 90% iso‐dose lines were also the highest with the noisy probing dose method (prostate: 0.983 ± 0.005; lung: 0.967 ± 0.01). For the 12 outlier cases, the noisy probing dose method maintained superior generalizability, yielding higher 3D Gamma passing rates (prostate targets: 96.79% ± 0.83%, OARs: 94.29% ± 1.01%; lung targets: 93.38% ± 1.34%, OARs: 93.95% ± 1.32%), demonstrating robust generalizability to rare clinical scenarios. The dose predictions for all testing cases were completed within 0.3 seconds. Conclusions A novel noisy probing dose method was proposed for PBSPT dose prediction in prostate and lung cancer patients. By embedding more proton‐specific physics, this method demonstrated an improvement in the generalizability of dose prediction.
Preventing and reducing burnout globally: a six continent thematic assessment
Linzer, Mark , Sullivan, Erin E, Nguyen, Trung Anh , Herco, Fiona, Holmes, Jennifer, Lovaton, Paula Gabriela Ponce de Leon, Sara, Jaskanwal Deep Singh , Goelz, Elizabeth , Hooper, Vallire, McWilliams, Jordan, Poplau, Sara , O’Brien, Emily, Sullivan, Erin E. , Hoare, Jacqueline , Lovaton, Paula Ponce de Leon, Alexandrou, Michaella , Hooper, Vallire D. , Porta, Carolyn M. , Montori, Víctor M.

Mayo Clinic

Research Connections | May 9, 2026 | Volume: 1 | Issue: 2 | Pages: No page available

10.1093/rescon/vmag064 | PMID 42358796 Get It

Abstract Background and Aims Burnout affects millions of healthcare workers worldwide, from food service and nurses to physicians and leaders, impairing worklives and threatening health system stability. Methods An international collaborative, PREVAIL, was created to reduce burnout globally. Leaders from six continents shared structured insights into the local state of wellness and burnout contributors and mitigators, which were then subjected to a formal thematic (qualitative) analysis to identify common and region-specific themes. Results Across continents, findings showed the global state of well-being was in danger, though threats varied by region: long shifts in Africa, heavy workloads in Asia, austerity-prone environments in Europe and financially driven care in North America. Vulnerable worker groups included women, nurses, and primary care. Mitigators included workload and schedule adjustments (Africa), shift policies with fair pay (Asia), leader support and regular well-being assessments (Australia), improved psychosocial services (Europe), organizational wellness support and career development (North America), and trainee support (South America). Conclusions A proposed “common pathway” framework explains shared drivers of poor workforce well-being and provides actionable steps for promoting compassionate, supportive environments worldwide. Implications/Learning Points Adopting a coordinated international approach may prevent devastating workforce shortages over the comingdecades. Burnout assessment and reduction in the global workforce is a high priority.
Web-Based Amblyopia Decision Support Tool
Summers, Allison I. , Hatch, S.W., Wiecek, Emily , Hribar, Michelle R. , Robinson, Julianne L., Chen, Angela M., Kulp, Marjean T., Chen, Debora M. Lee, Repka, Michael X., Roberts, Tawna L. , Wallace, David K. , Vricella, Marilyn, Chang, Steven, Stutz, Kathleen M., Beaulieu, Wesley T., Kraker, Raymond T., Cotter, Susan A., Holmes, Jonathan M., Weise, Katherine K., Pineles, Stacy L., (PEDIG), Pediatric Eye Disease Investigator Group, Hatt, Sarah R. , Chen, Angela M. , Kulp, Marjean Taylor , Repka, Michael X. , Wang, Jingyun, Beaulieu, Wesley T , Kraker, Raymond T. , Cotter, Susan A. , Holmes, Jonathan M.

Mayo Clinic

JAMA Ophthalmology | May 7, 2026 | Volume: 144 | Issue: 6 | Pages: 545

10.1001/jamaophthalmol.2026.1095 | PMID 42096234 Get It

Importance Amblyopia is the leading cause of monocular decreased best-corrected vision in children. Early detection and intervention are key for optimal treatment outcomes; however, limited access to pediatric eye specialists may hinder timely care and affect visual outcomes. Given the shortage of specialty-trained eye care professionals in the US, there is need to support comprehensive eye care professionals who are willing to examine and treat children with amblyopia. Objective A panel from the Pediatric Eye Disease Investigator Group synthesized relevant literature and incorporated consensus opinion where direct evidence was lacking to create the Amblyopia Navigator Decision-Support Instrument, a free, web-based amblyopia decision support tool for eye care professionals. Evidence Review The decisions related to optimal diagnostic measures, pass/refer criteria, and management recommendations were informed by 147 publications. In areas where direct evidence was lacking, guidance was supplemented with clinical trial protocols or existing professional guidelines. When data were conflicting or unavailable, recommendations were established through committee consensus. A single reviewer independently performed standardized (though not systematic) literature reviews to avoid missing pertinent recent publications. Findings Presented are the process used, supporting evidence, and recommendations for testing methods, refractive correction, amblyopia treatment options, treatment adjustments, and monitoring schedules. Conclusions and Relevance Because amblyopia is common and typically responds well to treatment, decision support tools that optimize its management could increase access to pediatric eye care by facilitating earlier detection, enabling broader participation of primary eye care professionals, and ultimately improving visual outcomes. Through this work and the development of the forthcoming free, web-based application version, Amblyopia Navigator Decision-Support Instrument, the Pediatric Eye Disease Investigator Group has created decision support tools designed to assist optometrists and ophthalmologists in the care of children aged 3 to 17 years with amblyopia.
Crowdsourced educational resource to distinguish Translational Science (TS) from Translational Research (TR)
Hafer, Nathaniel , Cielo, Karen, Duguid, Paul , Dunn, Mendy , Gholami, Maryam , Hunt, Joe, Kane, Cathleen , Moussatche, Patricia , Navarro, Christy , Patterson, Brittney Jackson, Vitale, Alfred , Kane, Cathleen , Moussatche, Patricia , Vitale, Alfred , Croker, Jennifer A. , Hafer, Nathaniel , Duguid, Paul , Gholami, Maryam , Holmes, Kristi , Hunt, Joe

Mayo Clinic

Journal of Clinical and Translational Science | May 6, 2026 | Volume: 10 | Issue: 1 | Pages: No page available

10.1017/cts.2026.10747 | PMID 42238987 Get It

At‐home visual acuity in children using a custom iPhone application compared with standardized in‐office visual acuity testing
Roberts, Tawna L. , Bothun, Erick D. , Zhu, Yufeng, Henderson, Robert J. , Boyle, Nicole M, Leske, David A. , Wernimont, Suzanne M., Marino, Carrie E, Manh, Vivian M. , Youngerman, Jillian M, Qayum, Jennifer N, Srinivasan, Gayathri , Titelbaum, Jenna R. , Crouch, Eric R. , Colburn, Jeffrey, Esposito, Christina , Zeto, V Lori, Connolly, Katie, Bhakta, Rita M, Lorenzana, Ingryd J., McDowell, Paula, Beaulieu, Wesley T, Kraker, Raymond T, Holmes, Jonathan M, Pineles, Stacy L., Weise, Katherine K., Cotter, Susan A, Group, Pediatric Eye Disease Investigator, Beaulieu, Wesley T , Kraker, Raymond T , Hatt, Sarah R. , Raghuram, Aparna , McDowell, Paula S., Kraker, Raymond T. , Holmes, Jonathan M. , Cotter, Susan A.

Mayo Clinic

Optometry and Vision Science | May 1, 2026 | Volume: 103 | Issue: 4 | Pages: No page available

10.1002/ovs2.70040 | PMID 42062237 Get It

ABSTRACT Purpose To validate a custom smartphone application for at‐home visual acuity (VA) measurement in children. Methods A total of 452 children aged 3–17.5 years participated. Certified examiners measured in‐office test–retest VA (logMAR) using gold‐standard Amblyopia Treatment Study HOTV (3‐to‐6‐year‐olds, younger cohort) or electronic Early Treatment of Diabetic Retinopathy Study (7‐to‐17.5‐year‐olds, older cohort) protocols at 3–4.5 m and app‐based VA at 1.5 m. Caregivers measured at‐home app‐based VA at 1.5 m. Results Comparing at‐home app‐based with gold‐standard VA, in eyes 20/40 or better, 95% (143/151) and 93% (91/98) of the younger and older cohorts were within 2 lines, respectively (mean differences: younger = −0.03, older = −0.04; 95% limits‐of‐agreement half‐width (LOA): younger = ±0.26, older = ±0.22). In eyes 20/50 or worse, 66% (42/64) and 75% (76/101) of the younger and older cohorts were within 2 lines, respectively (mean differences: younger = 0.11, older = 0.13, LOA: younger = ±0.50, older = ±0.51). Comparing in‐office app‐based VA with gold‐standard VA, in eyes 20/40 or better, 98% (160/164) and 94% (99/105) of the younger and older cohorts were within 2 lines, respectively (mean differences: younger = −0.03, older = −0.03; LOA: younger = ±0.22; older = ±0.24). In eyes 20/50 or worse, 85% (60/71) and 91% (101/111) of the younger and older cohorts were within 2 lines, respectively (mean differences: younger = 0.04; older = 0.04; LOA: younger = ±0.39; older = ±0.24). For gold‐standard test–retest, in eyes 20/40 or better, 99% (163/164) and 99% (104/105) of the younger and older cohorts had retest within 2 lines, respectively (mean differences: younger = 0.00; older = 0.01; LOA: younger = ±0.17; older = ±0.11). For 20/50 or worse, 92% (66/72) and 100% (111/111) in the younger and older cohorts were within 2 lines, respectively (mean differences: younger = 0.01; older = 0.02; LOA: younger = ±0.35; older = ±0.15). Conclusions Our app demonstrated good concordance with the gold standard at home and in the office for eyes with VA of 20/40 or better. However, concordance decreased considerably for eyes with VA 20/50 or worse, particularly at home.
COMPARISON OF CROWDED HOTV AND CROWDED ETDRS VA PROTOCOLS IN CHILDREN.
Rice, Melissa , Holmes, Jonathan M.

Mayo Clinic

Optometry and Vision Science | April 7, 2026 | Volume: 79 | Issue: S12 | Pages: 295-295

10.1002/j.1538-9235.2002.tb04439.x Get It

THE ELECTRONIC ETDRS TESTING PROTOCOL: RELIABILITY IN 7‐12 YEARS OLD CHILDREN.
Chu, Raymond, Kang, Felicia, Tran, Kevin, Cotter, Susan A. , Tran, Kevin, Beck, Roy W., Chandler, Danielle L, Moke, Pamela S., Holmes, Jonathan M., Rice, Melissa L., Hertle, Richard W., Birch, Eileen E.

Mayo Clinic

Optometry and Vision Science | April 7, 2026 | Volume: 79 | Issue: S12 | Pages: 232-232

10.1002/j.1538-9235.2002.tb04121.x Get It

Abstract 2740: Applications of large language models to CAR-T cell therapy clinical data using Google cloud computing.
Jankowski, Matthew, Corraes, Andre de Menezes Silva, Gupta, Malvika , Shaw, Monica, Iqbal, Madiha , Chhabra, Saurabh, McLean, Jody, Riester, Kim R., Joseph, Kayla, Tan, Melinda, Ross, Holly, Barnett, Cleyonia, Carter, Sylvia L., Girmay, Semy, Wolan, Rachel M., Ramsey, Milana, Downhour, Christian, Morgan, Kristy, Sibley, Shae, Rushing, Erica C., Holmes, Lucy , Burgstahler, Allison R., Ansell, Stephen M., Hathcock, Matthew, Bruno, Ramona L., Johnston, Patrick B., Paludo, J., Lin, Yi, Guzman, Emmanuel Contreras , Jankowski, Matthew, Corraes, Andre De Menezes Silva , Hilal, Talal , Chhabra, Saurabh , Parrondo, Ricardo D , Riester, Kimberly, Tan, Melinda, Holmes, Lucy, Ansell, Stephen M. , Alkhateeb, Hassan B. , Hathcock, Matthew , Rosenthal, Allison , Murthy, Hemant S. , Johnston, Patrick B, Paludo, Jonas

Mayo Clinic

Cancer Research | April 3, 2026 | Volume: 86 | Issue: 7_Supplement | Pages: 2740-2740

10.1158/1538-7445.am2026-2740 Get It

Abstract Large Language Models (LLM) are being widely adopted into the medical field for their impressive ability to analyze and summarize large amounts of text data. These models enable clinicians and researchers to extract meaningful insights from complex datasets and may assist with decision making. Here we present our workflows and application of LLM for the interpretation and summarization of clinical data related to CAR-T cell therapy. Using an LLM (Gemini 2.5 pro) in the Google Cloud Computing (GCP) environment, two applications were developed to analyze CAR-T cell therapy clinical data: 1) extracting and summarizing CRS and ICANS event-related data to streamline the compliance team workflow, and 2) identifying features available at time of CAR-T infusion able to classify patients into high- or low-monitoring needs 14 days post CAR-T. Patient data (vitals, labs, hematology notes, and EKGs) were extracted from the electronic medical record (EMR) using Google BigQuery into SQL tables in GCP. For each application, relevant data fields were retrieved, formatted into JSON objects, and embedded in the LLM prompt for context-aware processing. Both applications have undergone iterative prompt engineering after analyzing the LLM output against ground truth data in the EMR. For the application extracting and summarizing CRS and ICANS events, the LLM was optimized on Mayo Clinic Rochester data. When compared to the IEC compliance database, the LLM achieved 100% accuracy and F1 score for CRS events, and 96% accuracy and 82% F1 score for ICANS events. The match rate for CRS and ICANS grades were 83% and 89% respectively. We applied the same LLM to Mayo Clinic Arizona (MCA) and Mayo Clinic Florida (MCF) cases, who document clinical notes and toxicity flowsheet differently, and achieved an accuracy (MCA: 93%, MCF:93%) and F1 score (MCA: 96%, MCF: 96%) for CRS and accuracy (MCA: 81%, MCF:82%) and F1 score (MCA: 76%, MCF: 75%) for ICANS. LLM was able to capture events missed by manual reviews. For most of the discrepancies where compliance team final adjudication is needed, LLM will be updated to flag discrepancies for review by the compliance team. For the application related to the monitoring needs 14 days post CAR-T, the LLM identified 5 categories predictive of high or low monitoring needs post CAR-T infusion (disease status, inflammatory and tumor burden markers, hematologic status, renal function and performance status). Our model achieved a sensitivity of 85.7%, specificity of 23.8%, and F1 score of 65.5% for our first cohort, compared with data extracted by the LLM from the EMR. For our second cohort, with demographics statistically similar to cohort 1 and using the same 5 categories, the LLM achieved a sensitivity of 83.3%, a specificity of 28.6%, and F1 score of 65.4%. Our workflow and applications of LLM’s provide examples and guidance to others interested in applying LLM’s for clinical and research applications. Citation Format: Emmanuel Contreras Guzman, Matthew Jankowski, Andre De Menezes Silva Corraes, Malvika Gupta, Monica L. Shaw, Madiha Iqbal, Talal Hilal, Saurabh Chhabra, Ricardo Daniel Parrondo, Jody K. Mclean, Kim R. Riester, Kayla Joseph, Melinda Tan, Holly Ross, Cleyonia Barnett, Sylvia Carter, Semy Girmay, Rachel Wolan, Milana Ramsey, Christian Downhour, Kristy Morgan, Shae Sibley, Erica Rushing, Lucy Holmes, Allison Burgstahler, Stephen M. Ansell, Hassan Alkhateeb, Matthew Hathcock, Ramona Bruno, Allison C. Rosenthal, Hemant Murthy, Patrick B. Johnston, Jonas Paludo, Yi Lin. Applications of large language models to CAR-T cell therapy clinical data using Google cloud computing [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 2740.