Validation of a Commercial Reagent for the Depletion of Biotin from Serum/Plasma: A Rapid and Simple Tool to Detect Biotin Interference with Immunoassay Testing
Katzman, Brooke M. , Hain, Erin A, Baumann, N, Baumann, Nikola A, Donato, Leslie J.

Mayo Clinic

The Journal of Applied Laboratory Medicine | March 22, 2021 | Volume: 6 | Issue: 4 | Pages: 992-997

10.1093/jalm/jfab022 | PMID 33907809 Get It

Abstract Background It is important for clinical laboratories to have protocols for investigating suspected biotin interference in patient samples. VeraPrep Biotin™ is a commercial product used to rapidly deplete biotin from serum/plasma samples. The objectives of this study were to verify that VeraPrep Biotin™: (a) does not impact immunoassay analyte recovery in control samples and (b) can effectively deplete biotin from samples (both biotin-spiked and samples from donors who ingested biotin supplements). Methods De-identified residual waste serum/plasma samples were combined to create 9 pools for each immunoassay. Plasma/serum samples (n = 23) were obtained from 6 healthy donors at varying times following ingestion of biotin (20 mg, 100 mg, or 200 mg). Nine Elecsys immunoassays were evaluated using the e 602 (Roche Diagnostics Inc.). Control, biotin-spiked (n = 10, ∼400 ng/mL), and donor samples were assayed pre- and post-VeraPrep treatment. Percentage analyte recovery [(posttreatment/pretreatment) × 100] was calculated for control samples. A laboratory-developed LC–MS/MS method was used to quantify biotin. Results In control samples (n = 81), 90–110% analyte recovery was observed post-VeraPrep treatment in over 95% of samples (77/81). The pre- and post-VeraPrep treatment biotin concentration [mean ± standard deviation (SD)] for specimens spiked with up to 500 ng/mL biotin was 357 ± 47 ng/mL and 1.0 ± 0.6 ng/mL, respectively. The mean (range) biotin concentration for the donor samples pre- and post-treatment was 166 (15–1029) ng/mL and 0.2 (<0.1–3) ng/mL, respectively (P = 0.004). Conclusions These data demonstrate that treatment with VeraPrep Biotin™ does not affect analyte recovery in biotin-negative samples and effectively depletes both spiked and endogenous biotin in serum/plasma.
Effect of pH on the Quantification of Common Chemistry Analytes in Body Fluid Specimens Using the Roche cobas Analyzer for Clinical Diagnostic Testing
Nandakumar, Vijayalakshmi, Dolan, Christopher, Baumann, N, Block, Darci R , Dolan, Christopher T, Baumann, Nikola A

Mayo Clinic

American Journal of Clinical Pathology | March 10, 2021 | Volume: 156 | Issue: 5 | Pages: 722-727

10.1093/ajcp/aqab025 | PMID 34075393 Get It

Abstract Objectives To determine the influence of pH on recovery of analytes in body fluids (BFs), investigate the mechanism of pH interference, measure the frequency of abnormal-pH BFs received, and compare pH measured by meter and paper. Methods We performed pH titration in residual BFs. A low-pH BF was spiked and neutralized to investigate pH interference. We measured analytes on a Roche cobas c501 analyzer (Roche Diagnostics) and calculated the percent recovery. Measurement of pH using a meter and paper was conducted on 122 BF samples received in the laboratory. Results Enzyme activity in BFs was unaffected when pH = 7.4-8.5 lactate dehydrogenase, pH = 7.3-10.2 amylase, pH = 6.0-9.9 lipase, and pH = 1.3-11.7 all other analytes. BFs had mean (range) pH of 8.0 (5.1-8.9), with a mean (range) difference (paper ‒ meter) of ‒0.4 (‒0.6 to 1.1). Conclusions Irreversible loss of enzyme activity occurs in BFs at low pH. Few clinical BFs have pH < 7.0, but laboratories should incorporate pH measurement in BF workflows.
Global FT4 immunoassay standardization: an expert opinion review
Kratzsch, Jüergen, Baumann, N, Ceriotti, Ferruccio , Lu, Zhong X. , Herwaarden, Antonius E. van , Kasapic, Dusanka , Baumann, Nikola A, Giovanella, Luca , Schott, Matthias , Vieira, José Gilberto H. , Giovanella, Luca

Mayo Clinic

Clinical Chemistry and Laboratory Medicine (CCLM) | January 13, 2021 | Volume: 59 | Issue: 6 | Pages: 1013-1023

10.1515/cclm-2020-1696 | PMID 33554525 Get It

Abstract Objectives Results can vary between different free thyroxine (FT4) assays; global standardization would improve comparability of results between laboratories, allowing development of common clinical decision limits in evidence-based guidelines. Content We summarize the path to standardization of FT4 assays, and challenges associated with FT4 testing in special populations, including the need for collaborative efforts toward establishing population-specific reference intervals. The International Federation of Clinical Chemistry and Laboratory Medicine Committee for Standardization of Thyroid Function Tests has undertaken FT4 immunoassay method comparison and recalibration studies and developed a reference measurement procedure that is currently being validated. Further studies are needed to establish common reference intervals/clinical decision limits. Standardization of FT4 assays will change test results substantially; therefore, a major education program will be required to ensure stakeholders are aware of the benefits of FT4 standardization, planned transition procedure, and potential clinical impact of the changes. Assay recalibration by manufacturers and approval process simplification by regulatory authorities will help minimize the clinical impact of standardization. Summary Significant progress has been made toward standardization of FT4 testing, but technical and logistical challenges remain. Outlook Collaborative efforts by manufacturers, laboratories, and clinicians are required to achieve successful global standardization of the FT4 assays.
Human chorionic gonadotropin suspected heterophile interference investigations in immunoassays: a recommended approach
Jara-Aguirre, Jose C., Baumann, N, Block, Darci R , Baumann, Nikola A, Algeciras‐Schimnich, Alicia

Mayo Clinic

Clinical Chemistry and Laboratory Medicine (CCLM) | July 6, 2019 | Volume: 57 | Issue: 8 | Pages: 1192-1196

10.1515/cclm-2018-1142 | PMID 30753153 Get It

Abstract Background Heterophile antibody (HAb) interferences in immunoassays can cause falsely elevated hCG concentrations leading to incorrect diagnosis and treatments options. When results are not consistent with the clinical findings, hCG HAb interference investigation may be requested by the physician. A retrospective evaluation of the frequency of HAb interference was performed among cases of physician-requested investigations and the effectiveness of commercially available blocking reagents to detect HAb interference in two immunoassay systems was evaluated. Methods One hundred and thirteen physician requests for hCG HAb investigation from 2008 to 2017 were reviewed. The primary method used to measure hCG was the Beckman Coulter Access Total βhCG (2008–2010) and the Roche Elecsys HCG+β (2014–2017). HAb investigation included measurement by two immunoassays before and after treatment of samples with heterophile blocking reagents and serial dilution studies. Results Five cases of HAb and HAb-like interference were identified. The interference frequency was 6.7% for the Beckman assay and 2.9% for the Roche assay. The presence of HAb was detected using heterophile blocking reagents and an alternative method in three cases. The other two cases were detected due to discrepant results with an alternative method and non-linear serial dilutions (HAb-like). Conclusions HAb interference was observed in the Beckman and the Roche assays. The heterophile blocking reagents failed to detect 40% of interference cases. Blocking reagents should not solely be used for these investigations. Multiple strategies including the use of serial dilutions and using an alternative platform are critical when troubleshooting interferences in hCG immunoassays.
The Importance of Effective Communication: Some Food for Thought
Baumann, N, Baumann, Nikola A

Mayo Clinic

The Journal of Applied Laboratory Medicine | July 23, 2018 | Volume: 1 | Issue: 4 | Pages: 460-461

10.1373/jalm.2016.021865 | PMID 33636815 Get It

Reference Intervals
Klee, George G., Ichihara, Kiyoshi , Özarda, Yeşim , Baumann, N, Straseski, Joely A., Bryant, Sandra C. , Wood‐Wentz, Christina M. , Baumann, Nikola A

Mayo Clinic

American Journal of Clinical Pathology | July 16, 2018 | Volume: 150 | Issue: 6 | Pages: 545-554

10.1093/ajcp/aqy082 | PMID 30169553 Get It

Assessing Quality Control Strategies for HbA1c Measurements From a Patient Risk Perspective
Parvin, Curtis A., Baumann, N, Baumann, Nikola A

Mayo Clinic

Journal of Diabetes Science and Technology | February 16, 2018 | Volume: 12 | Issue: 4 | Pages: 786-791

10.1177/1932296818758768 | PMID 29451017 Get It

Background: Current laboratory risk management principles emphasize the importance of assessing laboratory quality control (QC) practices in terms of the risk of patient harm. Limited practical guidance or examples on how to do this are available. Methods: The patient risk model described in a published laboratory risk management guideline was combined with a recently reported approach to computing the predicted probability of patient harm to produce a risk management index (RMI) that compares the predicted probability of patient harm for a QC strategy to the acceptable probability of patient harm based on the expected severity of harm caused by an erroneously reported patient result. Results: Measurement procedure capability and quality control performance for two instruments measuring HbA1c in a laboratory were assessed by computing the RMI for each instrument individually and for the laboratory as a whole. Conclusions: This assessment provides a concrete example of how laboratory QC practices can be directly correlated to the risk of patient harm from erroneously reported patient results.
Biotin-Induced Biochemical Graves Disease
Sharma, Anu , Baumann, N, Shah, Pankaj, Baumann, Nikola A

Mayo Clinic

JAMA Internal Medicine | February 13, 2017 | Volume: 177 | Issue: 4 | Pages: 571

10.1001/jamainternmed.2016.9295 | PMID 28192572 Get It

Implementation of Clinical Decision Support Rules to Reduce Repeat Measurement of Serum Ionized Calcium, Serum Magnesium, and N-Terminal Pro-B-Type Natriuretic Peptide in Intensive Care Unit Inpatients
Moyer, Ann M. , Saenger, Amy K., Baumann, N, Block, Darci R , Botz, Chad M. , Jaffe, Allan S. , Hanson, Curtis A. , Karon, Brad S. , Willrich, Maria, Donato, Leslie J. , Baumann, Nikola A, Khan, Munawwar A., Willrich, Maria Alice V. , Khan, Munawwar Ali , Jaffe, Allan S.

Mayo Clinic

Clinical Chemistry | March 28, 2016 | Volume: 62 | Issue: 6 | Pages: 824-830

10.1373/clinchem.2015.250514 | PMID 27022069 Get It

Abstract BACKGROUND We assessed the impact of clinical decision support (CDS) rules within the electronic health record for ionized calcium (iCa), serum magnesium (Mg), and N-terminal pro-B-type natriuretic peptide (NT-proBNP) in intensive care unit (ICU) inpatients at a large academic center. METHODS A repeat order for measurement of iCa or Mg placed within 24 (iCa) or 48 (Mg) h of a previously nonactionable result, or additional orders for NT-proBNP beyond 1 within a single hospitalization, triggered a CDS pop-up alert showing the prior result and offering the opportunity to cancel the order or to place the order after entering an indication for repeat testing. The number of tests performed for each of these analytes and incidence of adverse clinical outcomes potentially associated with hypocalcemia or hypomagnesemia were compared between the 90-day period before CDS implementation and two 90-day periods immediately following. RESULTS iCa test volumes decreased by 48%, Mg by 39%, and NT-proBNP by 28% in the 90-day period immediately following implementation and remained decreased by 54%, 49%, and 22%, respectively, during the following 90-day period (all P values <0.0002). Adverse clinical outcomes potentially associated with hypocalcemia or hypomagnesemia did not increase (all P-values >0.17). CONCLUSIONS Implementation of CDS dramatically decreased repeat testing of iCa, Mg, and NT-proBNP without adversely impacting clinical outcomes in the ICU. Expansion of the rules from the ICU units to include the entire hospitalized patient population and expansion to additional analytes is expected to lead to further reductions in testing.