Automation and validation of a MALDI-TOF MS (Mass-Fix) replacement of immunofixation electrophoresis in the clinical lab

Clinical Chemistry and Laboratory Medicine (CCLM) | August 17, 2020 | Volume: 59 | Issue: 1 | Pages: 155-163

10.1515/cclm-2020-0581 | PMID 32745067

Abstract Objectives A matrix assisted laser desorption ionization time of flight mass spectrometry (MALDI-TOF MS) method (Mass-Fix) as a replacement for gel-based immunofixation (IFE) has been recently described. To utilize Mass-Fix clinically, a validated automated method was required. Our aim was to automate the pre-analytical processing, improve positive specimen identification and ergonomics, reduce paper data storage and increase resource utilization without increasing turnaround time. Methods Serum samples were batched and loaded onto a liquid handler along with reagents and a barcoded sample plate. The pre-analytical steps included: (1) Plating immunopurification beads. (2) Adding 10 μl of serum. (3) Bead washing. (4) Eluting the immunoglobulins (Igs), and reducing to separate the heavy and light Ig chains. The resulting plate was transferred to a second low-volume liquid handler for MALDI plate spotting. MALDI-TOF mass spectra were collected. Integrated in-house developed software was utilized for sample tracking, driving data acquisition, data analysis, history tracking, and result reporting. A total of 1,029 residual serum samples were run using the automated system and results were compared to prior electrophoretic results. Results The automated Mass-Fix method was capable of meeting the validation requirements of concordance with IFE, limit of detection (LOD), sample stability and reproducibility with a low repeat rate. Automation and integrated software allowed a single user to process 320 samples in an 8 h shift. Software display facilitated identification of monoclonal proteins. Additionally, the process maintains positive specimen identification, reduces manual pipetting, allows for paper free tracking, and does not significantly impact turnaround time (TAT). Conclusions Mass-Fix is ready for implementation in a high-throughput clinical laboratory.
Free Light Chain Assay Drift: Potential for Misdiagnosis?

The Journal of Applied Laboratory Medicine | June 18, 2020 | Volume: 5 | Issue: 6 | Pages: 1411-1413

10.1093/jalm/jfaa093 | PMID 32829402

Implementation of Clinical Decision Support Rules to Reduce Repeat Measurement of Serum Ionized Calcium, Serum Magnesium, and N-Terminal Pro-B-Type Natriuretic Peptide in Intensive Care Unit Inpatients

Clinical Chemistry | March 28, 2016 | Volume: 62 | Issue: 6 | Pages: 824-830

10.1373/clinchem.2015.250514 | PMID 27022069

Abstract BACKGROUND We assessed the impact of clinical decision support (CDS) rules within the electronic health record for ionized calcium (iCa), serum magnesium (Mg), and N-terminal pro-B-type natriuretic peptide (NT-proBNP) in intensive care unit (ICU) inpatients at a large academic center. METHODS A repeat order for measurement of iCa or Mg placed within 24 (iCa) or 48 (Mg) h of a previously nonactionable result, or additional orders for NT-proBNP beyond 1 within a single hospitalization, triggered a CDS pop-up alert showing the prior result and offering the opportunity to cancel the order or to place the order after entering an indication for repeat testing. The number of tests performed for each of these analytes and incidence of adverse clinical outcomes potentially associated with hypocalcemia or hypomagnesemia were compared between the 90-day period before CDS implementation and two 90-day periods immediately following. RESULTS iCa test volumes decreased by 48%, Mg by 39%, and NT-proBNP by 28% in the 90-day period immediately following implementation and remained decreased by 54%, 49%, and 22%, respectively, during the following 90-day period (all P values <0.0002). Adverse clinical outcomes potentially associated with hypocalcemia or hypomagnesemia did not increase (all P-values >0.17). CONCLUSIONS Implementation of CDS dramatically decreased repeat testing of iCa, Mg, and NT-proBNP without adversely impacting clinical outcomes in the ICU. Expansion of the rules from the ICU units to include the entire hospitalized patient population and expansion to additional analytes is expected to lead to further reductions in testing.