Von Hippel–Lindau disease (VHL) is a multineoplasm inherited disease manifesting with hemangioblastoma of the central nervous system and retina, adrenal pheochromocytoma, renal cell carcinoma, pancreatic neuroendocrine tumors and cysts, and neoplasms/cysts of the ear, broad ligament, and testicles. During 2018‐2020, the VHL Alliance gathered several committees of experts in the various clinical manifestations of VHL to review the literature, gather the available evidence on VHL, and develop recommendations for patient management. The current report details the results of the discussion of a group of experts in the pancreatic manifestations of VHL along with their proposed recommendations for the clinical surveillance and management of patients with VHL. The recommendations subcommittee performed a comprehensive systematic review of the literature and conducted panel discussions to reach the current recommendations. The level of evidence was defined according to the Shekelle variation of the Grading of Recommendations, Assessment, Development, and Evaluation grading system. The National Comprehensive Cancer Network Categories of Evidence and Consensus defined the committee members' interpretation of the evidence and degree of consensus. The recommendations encompass the main aspects of VHL‐related pancreatic manifestations and their clinical management. They are presented in a clinical orientation, including general planning of screening and surveillance for pancreatic neuroendocrine tumors, utility of biochemical biomarkers, the optimal choice for imaging modality, indirect risk stratification, indications for tissue sampling of VHL‐related pancreatic neuroendocrine tumors, and interventions. These recommendations are designed to serve as the reference for all aspects of the screening, surveillance, and management of VHL‐related pancreatic manifestations.
Prostate Artery Embolization—Review of Indications, Patient Selection, Techniques and Results
Lower urinary tract symptoms (LUTS) due to benign prostatic hypertrophy (BPH) are a very common problem in men ranging from mild urinary symptoms to recurrent urinary tract infections or renal failure. Numerous treatment options are available ranging from conservative medical therapies to more invasive surgical options. Prostate artery embolization (PAE) has emerged as a novel treatment option for this common problem with clinical efficacy comparable to the current surgical gold standard, transurethral resection of the prostate (TURP). PAE offers fewer complications and side effects without a need for general anesthesia or hospitalization. This review discusses the indications for prostate artery embolization in addition to LUTS, patient evaluation in patients with LUTS, PAE technique and clinical results, with an emphasis on efficacy and safety.
Activity of Omadacycline in Rat Methicillin-Resistant Staphylococcus aureus Osteomyelitis
Omadacycline, vancomycin, and rifampin, as well as rifampin combination therapies, were evaluated in an experimental rat model of methicillin-resistant Staphylococcus aureus (MRSA) osteomyelitis. All treatment groups had less MRSA recovered than saline-treated animals.
Performance Comparison of Multiplexed Fluorescent Resonance Emission Transfer Hybridization Probes Across Roche LightCycler® Real-Time PCR Systems for the Detection of Bartonella species
Abstract Introduction/Objective Molecular assays for Bartonella species are important in diagnosing infection and expediting patient treatment. Real time polymerase chain reaction (RT-PCR) using fluorescent resonance energy transfer (FRET) hybridization probes can be used to detect Bartonella species in blood and fresh/fixed tissue biopsies in RT-PCR instruments. Over time, new technologies and reagents are introduced and existing PCR primers and FRET probes must be re-validated on new platforms. This study aimed to compare the performance of a Bartonella RT-PCR assay using the sunsetting Roche LightCycler® 2.0 (Roche Diagnostics, Indianapolis, IN) and newer LightCycler® 480 RT- PCR instruments. Methods/Case Report DNA was extracted from 132 historically positive, whole organism spiked, and historically negative whole blood and formalin fixed paraffin embedded (FFPE) samples. Samples were run on the LightCycler® 2.0 using instrument specific LightCycler® FastStart DNA Master HybProbe enzyme and compared to results generated using the LightCycler® 480 and its instrument specific LightCycler® 480 Genotyping Master enzyme. During optimization, MgCl2 concentrations and thermocycling profiles were adjusted. Accuracy, specificity, inclusivity, and limit of detection studies were performed. Crossing point (Cp), melting temperature (Tm), fluorescent peak and fluorescent background values were compared between the two instruments. Results (if a Case Study enter NA) The agreement in accuracy between the LightCycler® 2.0 and the LightCycler® 480 was 100% for whole blood samples. For historically positive FFPE samples, LightCycler® 2.0 sensitivity and LightCycler® 480 sensitivity were 86% and 100%, respectively. Specificity and inclusivity of the assay were identical between the two instruments. The limit of detection in whole blood was 5-fold lower on the LightCycler® 480 (50 copies/µL) compared to the LightCycler® 2.0 (250 copies/µL). Mean Cp and fluorescent peak intensity values increased by 5.1% and 65-fold, respectively. Conclusion The study demonstrates similar performance and improved limit of detection for the Bartonella FRET hybridization probe RT-PCR assay on the LightCycler® 480 compared to the LightCycler® 2.0.
The Effect of Patellar Surface Morphology On Subchondral Bone Alignment When Matching Patellar Osteochondral Allografts (206)
Objectives: Recent research has shown that implanting a patellar osteochondral allograft with a non-matched surface morphology (i.e., Wiberg classification) does not create increased chondral surface deviation or circumferential step-off in the donor plug compared to the native patella. While much of the research on patellar osteochondral allografts has been focused on chondral surface matching, little has been done to determine if the subchondral bone alignment at the donor:native interface plays a role in graft healing, local force distribution, and long term success of the allograft transplant. Previous work in our lab demonstrated that even when the patellar cartilage surface was well matched, notable differences in subchondral bone alignment were observed. The purpose of this study was therefore to use surface contour mapping of subchondral bone to determine if differences in Wiberg classification play a role in the ability of donor patellar osteochondral allograft subchondral bone to align with the native patellar subchondral bone when treating osteochondral defects of the patellar apex. The hypothesis was that patellar surface morphology would have an effect on subchondral bone surface height deviation and circumferential step-off when performing osteochondral allograft transplants of the patellar apex. Methods: Sixty fresh frozen human patellae were acquired from a national donor procurement company. Twenty (10 Wiberg I and 10 Wiberg II/III) patellae were designated as the recipient and then nano-CT scanned. Each recipient was size-matched (within ±2mm tibial width) to both a Wiberg I and a Wiberg II/III patellar donor. A 16mm circular osteochondral “defect” centered on the central ridge of the patella was then created in the recipient patella. A randomly-ordered donor Wiberg I or Wiberg II/III plug was harvested from a homologous location and transplanted into the recipient. The recipient was then nano-CT scanner, digitally reconstructed, and superimposed on the initial nano-CT scan of the native recipient patella. After careful atraumatic removal of the first donor plug, the process was repeated using the other allograft plug. MATLAB was used to determine the root mean square (RMS) surface height deviation between the native and donor subchondral bone surfaces. Dragonfly 3D imaging software was used to measure the RMS subchondral bone step-off height at 3° increments around the circumference of the graft. Surface height deviation and circumferential step-off height were analyzed for the whole surface and by quadrant to determine if there were local differences. ANOVA was used to compare surface deviation and step-off heights between matched and unmatched grafts. Sidak’s multiple comparison test was used to complete sub-analysis between patellar graft quadrants. Comparisons were made between matched and unmatched grafts in terms of the RMS surface height deviation and step-off, as well as in the percentage of measurements that were more than 0.5mm, 1mm, and 2mm proud or sunken relative to the native surface. Results: There were no significant differences in RMS subchondral bone surface height deviation between matched and unmatched Wiberg plugs as a whole or by quadrant (RMS range = 0.69 to 0.97mm, p = 0.45 – 1.0). There was a significant difference in RMS circumferential step-off height between matched (1.14 ± 0.52mm) and unmatched (1.38 ± 0.49mm) Wiberg plugs ( p=0.015). The majority of these increased step-off measurements occurred in the lateral quadrant with lateral quadrant RMS step-off of 0.89 ± 0.43mm in matched grafts and 1.60 ± 0.78mm in unmatched grafts ( p=0.007). There was also a significant difference in the percent of step-off measurements greater than 2mm sunken in the lateral quadrant between matched and unmatched grafts (5.17 ± 20.87% matched, 24.5 ± 36.39% unmatched, p=0.028). There were no significant differences between matched and unmatched grafts for any other comparison using 0.5, 1, or 2mm cut-offs for circumferential step-off or surface height deviation. Combining all allografts, the respective proportion of surface deviation and circumferential step-off height measurements that were above the stated thresholds were as follows: 31% and 34% for a 0.5mm threshold, 15% and 21% for a 1mm threshold, and 2% and 8% for a 2mm threshold. Conclusions: While unmatched Wiberg patella osteochondral allograft implantation did not result in significantly different subchondral bone surface height deviations, there were significant differences in circumferential subchondral bone step-off heights. The majority of step-off height differences between Wiberg matched and unmatched osteochondral allografts occurred in the lateral quadrant. In comparison to previous data evaluating differences in the cartilage surface match in these patellar OCA transplants, the deviations and step-off heights in the subchondral bone identified in the current study were approximately 0.5mm greater than the differences in the cartilage surface. These findings therefore suggest there is greater variability in the alignment of the subchondral bone in these patellar osteochondral allografts than there is in the cartilage surface. Further investigation using finite element analysis modeling will help determine the implications of subchondral bone surface deviation and circumferential step-off on local cartilage:bone compression and shear force distribution. These studies may shed light on the mechanisms of failure in patellar osteochondral transplants and may help to better understand the contribution of subchondral bone alignment in OCA healing and long-term outcome.
Hypochlorous Acid-Generating Electrochemical Catheter Prototype for Prevention of Intraluminal Infection
Catheter-related infections constitute an economic and mortality burden in health care. Several options are available to reduce the risk of infection, but only a few focus on preventing intraluminal infection, which occurs in long-term catheters, most often used for dialysis, prolonged treatment, or chemotherapy.
S3370 Impact of Acute Kidney Injury on In-Hospital Outcomes of Endoscopic Retrograde Cholangiopancreatography
S1046 Predicting Histological Diagnosis After Endoscopic Submucosal Dissection With Demographic Characteristics and Endoscopic Lesion Characteristics: An Analysis of a Large Cohort in North America