Citations

Showing 10 of 107966 citations.

Technical Competency Assessment of Peripheral Blood Smears: Tools and Trends Learned From 2 College of American Pathologists Q-Probes Studies
Vos, Jeffrey A., Jiang, Liuyan , Blond, Barbara J., Coulter, Suzanne, Souers, Rhona J., Jiang, Liuyan Jennifer, Venkataraman, Girish , Souers, Rhona J.

Mayo Clinic

Archives of Pathology & Laboratory Medicine | December 24, 2024 | Volume: 149 | Issue: 9 | Pages: 797-804

10.5858/arpa.2024-0259-cp | PMID 39716877 Get It

Context.— Morphologic evaluation of peripheral blood smears provides valuable information to diagnose and manage a variety of hematologic disorders. Objective.— To measure the competency of the technical staff in the morphologic evaluation of peripheral blood smears and provide performance trends. Design.— Participating technologists accessed 10 whole slide–imaged peripheral blood smears through a web-based imaging tool in 2 separate studies. Participants performed a 100-cell differential and morphologic evaluation for each slide image. Grading criteria, determined by 3 hematopathologists, were weighted according to their clinical significance (score range, 0–100 for each case). Each institution and participant answered a questionnaire to assess the impact of current practices and educational programs on competency scores. Results.— A total of 776 technologists from 92 institutions participated in study 1 and 1495 technologists from 179 institutions participated in study 2. Median performance scores for institutions were 78.9 and 87.6 for studies 1 and 2, respectively, encompassing a range of hematologic disorders. Based on results of the questionnaire for study 1, higher performance scores were seen when institutions required a specific number of continuing education credits per year through an agency ( P = .005). In study 2, institutions with remediation procedures following a failed competency demonstrated higher performance scores ( P = .03). Conclusions.— Medical technologist competency of peripheral blood smears improves with level of experience and is positively impacted through attending educational programs. Whole slide images offer a convenient means of assessing technical competence and provide data to allow institutions to appropriately focus their procedures and educational efforts.
Laser Ablation of an Isolated External Auditory Canal Skin Wedge
Lakpa, Koffi L. , Eyassu, Daniel G. , Wiedermann, Joshua P.

Mayo Clinic

Annals of Otology, Rhinology & Laryngology | December 24, 2024 | Volume: 134 | Issue: 5 | Pages: 366-369

10.1177/00034894241309219 | PMID 39716813 Get It

Introduction: External ear malformations represent a spectrum of congenital anomalies that may involve the external auditory canal (EAC), tympanic membrane (TM), or associated structures. A rare anomaly, the EAC skin wedge, results from incomplete canalization during embryologic development. This report presents the clinical presentation, diagnostic evaluation, and surgical management of this condition. Objective: To detail the successful surgical management of an isolated EAC skin wedge and demonstrate the applicability of argon laser in treating these congenital anomalies. Methods: A 13-month-old female presented with recurrent otitis media and mild bilateral conductive hearing loss. Physical examination revealed a fan-like skin wedge spanning the EAC to the TM. Imaging with temporal bone computed tomography confirmed the extent of the anomaly. Under general anesthesia, the skin wedge was ablated using an argon laser, followed by antibiotic-soaked packing to prevent scarring and recurrence. Follow-up audiometry and endoscopic evaluations assessed outcomes. Results: The procedure was well-tolerated, with no intraoperative complications. At 3 weeks and 3 months postoperatively, no recurrence of the skin wedge was observed, and audiometry normalized. The patient demonstrated improved middle ear ventilation and resolution of conductive hearing loss. Conclusions: This case demonstrates the successful use of argon laser in the management of a rare congenital EAC anomaly. Argon lasers offer precise ablation and excellent hemostasis, making them a valuable option for similar cases. This report emphasizes the importance of tailored surgical approaches for rare pediatric ear malformations.
The Intraosseous Subarcuate Loop of Anterior Inferior Cerebellar Artery: Anatomic Management Guide, Single-Center MRI Study, and Scoping Review
Plou, Pedro , Athanasoulis, Filippos , Kollia, Sofia , Leonel, Luciano, Carlson, Matthew L. , Link, Michael J. , Peris‐Celda, Maria , De Bonis, Alessandro, Torregrossa, Fábio , Serioli, Simona , Leonel, Luciano César P C, Carlson, Matthew, Bonis, Alessandro De, Bauman, Megan M. J.

Mayo Clinic

Operative Neurosurgery | December 24, 2024 | Volume: 29 | Issue: 3 | Pages: 389-398

10.1227/ons.0000000000001474 | PMID 39716468 Get It

BACKGROUND AND OBJECTIVES: The intraosseous subarcuate loop (SL) is a unique variant of the anterior inferior cerebellar artery (AICA), where a loop of the artery is trapped in the petrous bone's subarcuate fossa (SF). Recognizing this variant is crucial for planning cerebellopontine angle (CPA) surgeries; however, data regarding its frequency and management vary in the published literature. A cohort from a single center was studied using MRI to assess its prevalence, and the findings were compared with the existing literature. In addition, an intraoperative guide for mobilizing the intraosseous AICA's SL was provided through a detailed step-by-step cadaveric dissection. METHODS: Two hundred fifty-eight patients who had undergone MRI scans of the CPA (516 sides) were retrospectively reviewed. MRIs displaying vascular loops visible in the axial view were analyzed using multiplanar reconstruction, and the intraosseous loop frequency was evaluated. A scoping review was undertaken to provide an overview of previously published data on its prevalence. One embalmed and latex-injected specimen with intraosseous AICA's SL was dissected through a retrosigmoid approach, and 1 surgical case was detailed, describing the procedure to release it. RESULTS: Intraosseous AICA's SL mobilization involves the identification of its entry and exit points within the petrous bone, dural incision to expose the SF, SF drilling, subarcuate artery division, and detaching the vascular loop. Preservation of a dural cuff is crucial to prevent vascular injury. We analyzed 258 brain MRIs (mean age 55 years, 42% male). The intraosseous AICA's SL was present in 4 of 516 evaluated CPAs (0.8%). The prevalence of the vascular anomaly in the reviewed literature using different radiological modalities ranged from 0.2% to 1.6%. CONCLUSION: The intraosseous AICA's SL is an uncommon anatomic variation detectable by MRI, posing an added risk in CPA surgery. Identifying and properly mobilizing it is crucial for safe vascular preservation.
Outcomes of DCD Liver Transplant Using Sequential Normothermic Regional Perfusion and Normothermic Machine Perfusion or NRP Alone Versus Static Cold Storage
Croome, Kristopher P. , Subramanian, Vijay , Mathur, Amit K. , Aqel, Bashar , Clendenon, Jacob N. , Perry, Dana K. , Dhanireddy, Kiran, Clendenon, Jacob , Taner, C. Burcin , Croome, Kris P , Aqel, Bashar A. , Mao, Shennen A.

Mayo Clinic

Transplantation | December 24, 2024 | Volume: 109 | Issue: 7 | Pages: 1184-1190

10.1097/tp.0000000000005301 | PMID 39716357 Get It

Background. The availability of in situ normothermic regional perfusion (NRP) or ex situ normothermic machine perfusion (NMP) has revolutionized donation after circulatory death (DCD) liver transplant (LT). While some have suggested that NRP and NMP may represent competing technologies for DCD LT, there are many scenarios where these technologies can function in a complementary manner. Methods. Between January 2022 and March 2024, 83 DCD LTs were performed using NRP (62 NRP alone and 21 NRP + NMP) and were compared with 297 static cold storage (SCS) DCD LTs. NRP + NMP was used in scenarios with (1) long travel distances, (2) complicated transplant recipients, or (c) the need for additional liver graft recovery in “marginal” cases. Results. Ischemic cholangiopathy was lower in the NRP alone group (0%) and the NRP + NMP group (0%) compared with the SCS group (16.8; P < 0.001 and P = 0.04, respectively). In addition, early allograft dysfunction, number of packed red blood cells transfused, and acute kidney injury were lower in the NRP alone and NRP + NMP groups compared with the SCS group. Graft survival was higher in cases where NRP was used than in cases where SCS was used ( P = 0.016). In all the cases where lactate remained elevated at the end of NRP (mean 8.2 ± 2.0), it ultimately normalized at the end of NMP (0.92 ± 0.56). Conclusions. The present study demonstrates lower rates of ischemic cholangiopathy and improved graft survival with NRP alone or NRP + NMP compared with SCS when using liver grafts from DCD donors. It also demonstrates that excellent outcomes can be achieved with sequential NRP + NMP in cases with prolonged travel distances, complicated recipients, or when there is a need for additional liver recovery in “marginal” cases.
Bulto dorsoradial de la muñeca: Desaparición de la tabaquera anatómica como un signo de “SLAC”
Oliveira, Ricardo Kaempf de , Colombelli, Luna Hussein , Kakar, Sanjeev , Atzei, Andrea , Baixauli, Vicente Carratalá , Delgado, Pedro J. , Kakar, Sanjeev

Mayo Clinic

Revista Iberoamericana de Cirugía de la Mano | December 23, 2024 | Volume: 52 | Issue: 02 | Pages: e131-e134

10.1055/s-0044-1793923 Get It

ResumenLa tabaquera anatómica, una región triangular en la porción dorso-radial de la muñeca, es un punto de referencia anatómico clave. Está delimitada por los tendones del extensor largo del pulgar, extensor corto del pulgar y abductor largo del pulgar, y alberga la arteria radial y ramas nerviosas. Patologías como quistes sinoviales, fracturas y osteofitos pueden alterar su apariencia. Estudios sobre lesiones del ligamento escafolunar (SLL) muestran que el daño crónico provoca el desplazamiento dorso-radial del escafoides, iniciando un proceso degenerativo conocido como colapso avanzado escafolunar (SLAC). Esto a menudo resulta en la "desaparición" de la tabaquera anatómica, lo que facilita la identificación de pacientes con muñeca SLAC junto con síntomas como dolor y rigidez. La afección es impulsada por la formación de osteofitos, subluxación del escafoides y sinovitis, lo que conduce a inestabilidad articular y deformidad. Los tratamientos tradicionales, como la estiloidectomía, pueden no resolver completamente la inestabilidad. Nuevos enfoques que consideran la dinámica tridimensional de la muñeca podrían ser más efectivos para manejar el SLAC. Estudios biomecánicos sugieren que las lesiones del SLL, junto con la pérdida de estabilizadores secundarios, provocan que el escafoides se pronuncie y flexione, resultando en una proyección dorso-radial dentro de la fosa del escafoides. Sin tratamiento, esto puede progresar a SLAC, frecuentemente caracterizado por el "bulto dorso-radial de la muñeca".
AI-Enabled Fusion of Electrocardiograph and Demographics for Prediction of Acute Kidney Injury Onset
Damodaran, Vasundhara , Sanchez, Jose , Gupta, Tushar , Bikkina, Phaneendra , Mikkola, Esko, Haidar, Abdul-Muhsin, Mikkola, Esko, Banerjee, Imon , Sanyal, Arindam

Mayo Clinic

2024 IEEE Biomedical Circuits and Systems Conference (BioCAS) | December 23, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-5

10.1109/biocas61083.2024.10798304 Get It

Mixed-Signal Classifier Chip on Flexible Substrate for Cardiovascular Health Monitoring
Bhanushali, Sumukh Prashant , Sadasivuni, Sudarsan , Sanchez, Jose, Banerjee, Imon , Sanyal, Arindam

Mayo Clinic

2024 IEEE Biomedical Circuits and Systems Conference (BioCAS) | December 23, 2024 | Volume: No volume available | Issue: No issue available | Pages: 1-5

10.1109/biocas61083.2024.10798218 Get It

Development of an automated CBCT‐based simulation‐free platform for expedited palliative radiotherapy on a conventional linear accelerator
Tegtmeier, Riley C. , Clouser, Edward , Chen, Quan , Buckey, C, Chungbin, Suzanne J., Kutyreff, Christopher J. , Labbe, Amber L., Horning, Brooke L., Rule, William G., Vora, Sujay A., Chen, Quan , Clouser, Edward L, Buckey, Courtney R, Aguilar, Jose S, Rong, Yi , Kutyreff, Christopher J , Clouser, Edward Lee , Aguilar, Jose S., Labbe, Amber L., Rong, Yi

Mayo Clinic

Journal of Applied Clinical Medical Physics | December 23, 2024 | Volume: 26 | Issue: 4 | Pages: No page available

10.1002/acm2.14612 | PMID 39715307 Get It

AbstractBackgroundConventional approaches for emergent or expedited palliative radiotherapy (RT) involve the application of cumbersome vendor‐provided solutions and/or multiple patient appointments to complete the RT workflow within a compressed timeframe.PurposeThis report delineates the clinical development of an in‐house, semi‐automated Cone‐beam computed tomography (CBCT)‐based simulation‐free platform for expedited palliative RT on conventional linacs, intended to supplant existing techniques employed at this institution.MethodsThe internal software, termed SimFree Wizard (SFW), was engineered utilizing a C#‐based application programming interface integrated within the treatment planning system (TPS). Generated scripts were compiled as stand‐alone executables, with a graphical user interface (GUI) customized via an integrated development environment. The platform was conceived as a framework for accelerated CBCT‐based RT, bypassing the requirement for standard simulation imaging. SFW employs full automation where feasible to minimize user intervention, supplemented by graphical instructions for tasks requiring manual execution. During development, relevant temporal metrics from 10 end‐to‐end tests for palliative spine RT were quantified. User feedback was solicited via a simple questionnaire assessing the overall platform usability. Automated in‐house secondary verification software was developed for validation of the TPS‐calculated monitor units (MUs).ResultsThe mean duration for workflow execution was 41:42 ± 3:18 [mm:ss] (range ∼37–46 min). SFW satisfactorily generated simple, multi‐field CBCT‐based 3D treatment plans within seconds following delineation of the desired treatment area. User feedback indicated enhanced usability compared to previously employed solutions. Validation of the secondary verification software demonstrated accurate results for palliative spine RT and other simple cases wherein the dose calculation point resides in a predominantly homogenous medium.ConclusionA novel in‐house solution for expedited CBCT‐based RT was successfully developed, facilitating completion of the entire workflow within approximately 1‐hour or less for simple palliative/emergent scenarios. Overall, this application is expected to improve the quality and safety of palliative RT while greatly reducing workflow duration, thereby improving access to palliative care.