Citations

Showing 10 of 107854 citations.

Automated AI-Based Aortic Measurements From Attenuation Correction CT as an Adjunctive Cardiovascular Risk Biomarker: An International Multicenter Study
Marcinkiewicz, Anna M , Shanbhag, Aakash , Chareonthaitawee, Panithaya , Zhang, Wenhao, Jilaihawi, Hasan , Zaid, Ryan , Cadet, Sebastien , Ramirez, Giselle , Lemley, Mark , Yi, Jirong , Hijazi, Waseem , Liang, Joanna X. , Fehér, Attila , Mason, Steve, Alexanderson, Erick, Carvajal-Juarez, Isabel , Travin, Mark I. , Rosamond, Thomas, Wopperer, Samuel , Berman, Daniel S. , Carli, Marcelo F. Di , Al-Jilaihawi, Hasanian , Builoff, Valerie , Calsavara, Vinicius F , Einstein, Andrew Jeffrey , Miller, Edward J , Feher, Attila , Ruddy, Terrence D , Le, Viet T , Knight, Stacey , Carvajal-Juarez, Isabel , Slipczuk, Leandro , Rosamond, Thomas L , Wopperer, Samuel , Berman, Daniel , Dey, Damini , Di Carli, Marcelo F , Miller, Robert J H , Slomka, Piotr J , Chareonthaitawee, Panithaya , Lemley, Mark , Ramirez, Giselle , Shanbhag, Aakash , Zaid, Ryan , Miller, Edward J. , Le, Viet T. , Mason, Steve, Knight, Stacey , Alexanderson, Erick , Slipczuk, Leandro , Dey, Damini , Miller, Robert J.H.

Mayo Clinic

Circulation: Cardiovascular Imaging | July 2, 2026 | Volume: 19 | Issue: 7 | Pages: No page available

10.1161/circimaging.125.019726 | PMID 42389791 Get It

BACKGROUND: Aortic enlargement is a powerful predictor of dissection and rupture, yet it is rarely evaluated during routine myocardial perfusion imaging, despite the widespread availability of computed tomography (CT) attenuation correction scans. The aim of this study was to determine whether fully automated, opportunistically derived, artificial intelligence-based aortic measurements from myocardial perfusion imaging CT attenuation correction scans are associated with adverse outcomes in a large multicenter cohort. METHODS: CT attenuation correction scans from patients undergoing positron emission tomography/CT and single-photon emission CT/CT myocardial perfusion imaging across 10 centers were included. A deep learning model automatically segmented the thoracic aorta, and a postprocessing algorithm extracted maximum ascending and descending diameters. The aortic size index was calculated by indexing the diameter to body surface area. RESULTS: A total of 29 339 patients (56% men; median age, 66 years [interquartile range, 58–75 years]) were included. Over a median follow-up of 3.5 years (interquartile range, 1.9–5.0 years), 5083 (17.3%) patients died. Median ascending and descending aortic size index values were 1.8 cm/m 2 (interquartile range, 1.6–2.0) and 1.5 cm/m 2 (interquartile range, 1.4–1.6), respectively, with an increase with age and higher values in females. Elevated aortic size index thresholds (ascending >2.2 cm/m 2 ; descending >1.6 cm/m 2 ) were significantly associated with increased all-cause mortality (ascending: adjusted hazard ratio, 1.16 [95% CI, 1.07–1.26], P <0.001; descending: adjusted hazard ratio, 1.23 [95% CI, 1.14–1.31]; P <0.001). Notably, the prognostic value of an abnormal aortic size index persisted independent of age, sex, and perfusion abnormalities. CONCLUSIONS: Artificial intelligence can unlock previously unused information within routine myocardial perfusion imaging CT attenuation correction scans by rapidly and automatically quantifying aortic size at scale. Opportunistic aortic measurements derived from CT attenuation correction may serve as an adjunctive risk biomarker and could add prognostic value to standard myocardial perfusion imaging without additional imaging or radiation.
Effects of Acoramidis on Kidney Function in Transthyretin Amyloid Cardiomyopathy
Testani, Jeffrey M. , Judge, Daniel P. , Borlaug, Barry A. , Cherney, David Z.I. , Gillmore, Julian D. , Lewis, Julia B. , Adler, Scott, Cao, Xiaofan , Castaño, Adam , Fox, Jonathan C. , Katz, Leonid , Mathur, V, Xiong, Kuangnan, Masri, Ahmad , Cherney, David , Cox, Zachary L , Gillmore, Julian D , Lewis, Julia B , Adler, Scott H , Cao, Xiaofan , Castaño, Adam , Fox, Jonathan C , Xiong, Kuangnan , Butler, Javed , Masri, Ahmad , Borlaug, Barry A , Testani, Jeffrey M , Judge, Daniel P , Mathur, Vandana S. , Butler, Javed

Mayo Clinic

Circulation: Heart Failure | July 2, 2026 | Volume: 19 | Issue: 8 | Pages: No page available

10.1161/circheartfailure.126.014656 | PMID 42389794 Get It

BACKGROUND: Acoramidis achieves near-complete (≥90%) transthyretin stabilization and is approved to reduce cardiovascular-related mortality and hospitalization in transthyretin amyloid cardiomyopathy. Its effects on kidney function are not well characterized. METHODS: Data from randomized phase 2 (N=49) and phase 3 (N=632) studies in transthyretin amyloid cardiomyopathy were included. The estimated glomerular filtration rate (eGFR) slope was generated using a linear spline mixed-effects model. The urinary albumin-to-creatinine ratio was measured longitudinally. Relationships between changes in kidney function and clinical outcomes were explored using Cox proportional hazards models. RESULTS: Acoramidis initiation resulted in a modest acute dip in eGFR that was dose-dependent, reversible, and not associated with adverse kidney-related events. At Day 28, the mean (±SE) dip in eGFR from baseline with acoramidis was 8.5±0.48 mL/min per 1.73 m 2 ; the placebo-corrected reduction in the urinary albumin-to-creatinine ratio was 15.5% (95% CI, 0.4%–28.4%; P =0.044). The rate of decline in kidney function (chronic eGFR slope) was significantly improved with acoramidis versus placebo (−1.01 versus −3.48 mL/min per 1.73 m 2 per year; P <0.001), and the reduction in the urinary albumin-to-creatinine ratio was sustained (13.7% [95% CI, 1.7%–24.2%]; P =0.026) over time. Concomitant tafamidis use did not influence the chronic eGFR slope in either arm. Comparing acoramidis versus placebo subgroups with acute eGFR dips ≥ the median (4.89 mL/min per 1.73 m 2 ) favored acoramidis for all-cause mortality or cardiovascular-related hospitalization (hazard ratio, 0.42 [95% CI, 0.22–0.78]; P =0.006; P interaction=0.043) and cardiovascular-related hospitalization (hazard ratio, 0.34 [95% CI, 0.17–0.66]; P =0.002, P interaction=0.025). Within the placebo arm, eGFR dips portended worse outcomes. CONCLUSIONS: Acoramidis initiation resulted in an acute dip in eGFR and reductions in both the chronic eGFR slope and urinary albumin-to-creatinine ratio versus placebo without adverse kidney-related events. Acoramidis effects on kidney function may be mediated through direct kidney-protective hemodynamic effects. Importantly, the acute dip in eGFR was associated with a reduced risk of adverse clinical outcomes within the first year. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifiers: NCT03458130, NCT03536767, NCT03860935, NCT04988386.
Beyond fluorescence intensity: a Minimum acquisition and reporting standard and emerging technologies for colorectal indocyanine green fluorescence angiography studies
Chhetri, Parvat Kuwar , Bhan, Anmol, Rumer, Kristen K., Larson, D. W., Kuwar Chhetri, Parvat, Bhan, Anmol, Rumer, Kristen K. , Larson, David W.

Mayo Clinic

Frontiers in Surgery | July 2, 2026 | Volume: 13 | Issue: No issue available | Pages: No page available

10.3389/fsurg.2026.1864848 | PMID 42465862 Get It

Background Intraoperative indocyanine green fluorescence angiography (ICG-FA) is increasingly utilized to assess bowel perfusion during colorectal anastomosis. Although recent multicenter randomized trials have yielded mixed findings, pooled randomized evidence and 2025 SAGES guidance indicate an overall benefit, particularly in left-sided and rectal surgery. However, acquisition protocols, interpretation criteria, and reported endpoints remain heterogeneous. Main message ICG-FA reflects the dynamics of an intravascular dye signal and is affected by injection technique, hemodynamic status, camera geometry, display mode, and platform-specific processing. Visual interpretation shows substantial interobserver variability. Thus, single fluorescence-intensity snapshots are unstable for comparison. In contrast, time-intensity kinetics and spatial heterogeneity measures are more reproducible and physiologically meaningful. Among reported kinetic metrics, the time ratio (TR = T1/2Max/Tmax) is promising. However, current evidence is preliminary and needs multicenter validation. Proposal We propose a practical minimum acquisition and reporting standard for colorectal ICG-FA studies as an expert-opinion framework for future consensus development. This includes consistent reporting of ICG administration, physiological status at assessment, imaging conditions, camera geometry, analysis methodology, measured outcomes, decision impact, and software/version details. We also describe other relevant approaches, such as laser speckle contrast imaging (LSCI), hyperspectral imaging (HSI), and artificial intelligence (AI)-assisted interpretation. Conclusions The key question is no longer only whether ICG-FA should be used, but how its signal should be acquired, quantified, interpreted, and reported. Better standardization should improve comparability, support multicenter validation, and clarify where perfusion imaging adds the greatest clinical value.
Counterfactual Dermatology With Generative Models
Bahari, Rose , Goldust, Mohamad , Aristizabal Torres, Miguel A, Goldust, Mohamad , Aristizabal, Miguel

Mayo Clinic

International Journal of Dermatology | July 2, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/ijd.70567 | PMID 42387814 Get It

Caregiver Reports of Lucid Episodes in Alzheimer’s Dementia and Lewy Body Dementias
Bangerter, Lauren R. , Kim, Kyungmin , Liu, Yin, Radford, Jonathan Graff, Liu, Yin, Lapid, Maria I. , Griffin, Joan M.

Mayo Clinic

Journal of Geriatric Psychiatry and Neurology | July 2, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/08919887261464594 | PMID 42387273 Get It

Purpose of Research Lucidity is the transient recovery of abilities and communication that were seemingly lost among people living with dementia (PLWD). This study describes lucid episodes reported by Alzheimer’s dementia (AD) and Lewy Body Dementias (LBD) caregivers. We analyzed survey data from 212 current AD ( n = 191) and LBD caregivers who reported the frequency, duration, and characteristics of 653 lucid episodes witnessed in the past month. Major Findings Most AD caregivers (67%) and LBD caregivers (81%) witnessed a lucid episode within the past month. LBD caregivers reported lucid episodes with greater changes in awareness and communication, compared to AD caregivers. LBD caregivers reported longer lucid episodes and that the PLWD knew about their change in lucidity, compared to AD caregivers. Conclusions Findings suggest that differences in lucid episode intensity, timing, and meta-awareness between AD and LBD are possible and may inform care strategies for PLWD.
Accuracy of Palpation‐Guided Versus First Attempt at Ultrasound‐Guided Electromyography Needle Placement for the Extensor Carpi Radialis Longus and Brevis by Trainees
Meiling, James B. , Wu, Kitty Y., Boon, Andrea J. , Luetmer, Marianne T. , Meiling, James B

Mayo Clinic

Muscle & Nerve | July 2, 2026 | Volume: 74 | Issue: 3 | Pages: 709-713

10.1002/mus.70333 | PMID 42386491 Get It

ABSTRACT Introduction/Aims Ultrasound (US) guidance may be essential for accurate electromyography (EMG) needle placement in less‐commonly evaluated muscles, such as the extensor carpi radialis longus (ECRL) and brevis (ECRB), and particularly for identifying suitable donor muscles prior to tendon transfers to restore upper extremity function. Our primary aim was to compare the accuracy of trainee palpation‐guided versus first‐attempt US‐guided needle placement. Our secondary aim was to describe the locations of inaccurate needle placement. Methods Seven subjects each performed four needle placements (ECRL and ECRB, both palpation‐guided and US‐guided), totaling 28 placements into a cadaveric specimen. US‐guided needle placement was performed with one attempt after one live demonstration. Results No palpation‐guided ECRL attempts were accurate while only two of the palpation‐guided ECRB attempts were accurate. First‐attempt US‐guided needle placement was significantly more accurate overall (64.3% vs. 14.2%, p = 0.020), and specifically for ECRL (71.4% vs. 0%, p = 0.025). Combining palpation‐guided ECRL and ECRB attempts, the needle was inadvertently placed in the extensor digitorum communis (50%), extensor carpi ulnaris (16.7%), and brachioradialis (16.7%). Both US‐guided ECRL‐intended errors involved placing the needle into the adjacent ECRB. Discussion This study suggests that EMG needle placement into ECRL and ECRB by trainees may be more accurate with US guidance. Accurate preoperative individual needle assessments of both wrist extensors are essential for patients with tetraplegia considering reconstructive surgery to restore functional grasp and should be performed with US guidance.
A Second Report of a Missense Variant in AMMECR1 Causing Midface Hypoplasia, Hearing Impairment, Elliptocytosis, and Nephrocalcinosis: Case Report and Lit
Tan, Jia W., Wilke, Matheus Vernet Machado Bressan , Panwar, Deepak , Kahn, Eva S., Figueiral, Marta , Xiao, Yao , Sas, David J. , Lanpher, Brendan C. , Vairo, Filippo Pinto e, Klee, Eric W. , Pinto E Vairo, Filippo, Wilke, Matheus V M B , Panwar, Deepak , Dikilitas, Ozan

Mayo Clinic

Clinical Genetics | July 2, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/cge.70209 | PMID 42386221 Get It

ABSTRACT Pathogenic variants in AMMECR1 have been associated with a rare multisystem disorder characterized by midface hypoplasia, hearing impairment, elliptocytosis, and nephrocalcinosis (MFHIEN). To date, most reported cases involve copy number variants or presumed loss‐of‐function alterations, with only a single prior report describing a missense variant supported by functional studies. Here, we report a patient with a heterozygous de novo AMMECR1 missense variant, NM_015365.3:c.649G>A p.(Val217Met) presenting with clinical features consistent with MFHIEN, including midface hypoplasia, partial hearing impairment, nephrocalcinosis, and elliptocytosis identified on peripheral blood smear. Comparative review of the literature highlights that while previously reported missense variants in AMMECR1 demonstrated altered intranuclear protein distribution and reduced expression in functional assays, clinical evidence supporting pathogenicity of non‐truncating variants remains limited. The phenotypic overlap between our patient and prior report strengthens the association between missense variations and the MFHIEN phenotype. Our findings support the pathogenic relevance of missense variation in AMMECR1 and emphasize the importance of integrating detailed phenotyping, including hematologic evaluation, with genomic data in the diagnosis of rare multisystem disorders. Additional cases and functional studies are needed to clarify genotype–phenotype correlations and underlying disease mechanisms.
In Response
Pai, Sher‐Lu , Harbell, Monica W. , Pai, Sher-Lu , Harbell, Monica W

Mayo Clinic

Anesthesia & Analgesia | July 1, 2026 | Volume: 143 | Issue: 2 | Pages: e28-e29

10.1213/ane.0000000000008152 | PMID 42385731 Get It

Growing Heart Valves in Congenital Cardiac Surgery: Mechanisms and Considerations for Tissue-Engineered Heart Valves, Noncryopreserved Homografts, and Partial Heart Transplantation
Lee, Deng Siang , Alexander, Vincent, Vogel, Andrew, Vogel, Andrew D. , Rajab, Taufiek Konrad

Mayo Clinic

Cardiology in Review | July 1, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1097/crd.0000000000001384 | PMID 42385140 Get It

Abstract: Heart valve abnormalities are present in 30% of congenital heart defects. Additionally, there are acquired conditions like rheumatic heart disease. They often require surgery, and in complex cases, valve replacement becomes unavoidable. The current valve replacement options, either mechanical, bioprosthetic, homografts, or autografts, lack key properties for pediatric patient needs: availability, durability, and the ability to grow. Our goal is to review 2 clinically relevant innovations: tissue-engineered heart valves (TEHVs) and partial heart transplantation (PHT). We conducted searches in electronic databases covering the past 25 years using the terms “partial heart transplantation,” “tissue-engineered heart valves,” and their combinations. Decellularized pulmonary homografts outperform cryopreserved homografts and bovine jugular vein conduits in pulmonary valve replacement, showing less stenosis and no infective endocarditis. The European Clinical Study for the Application of Regenerative Heart Valves trial confirmed decellularized pulmonary homograft safety, demonstrating 97.5% freedom from explantation at 5 years. Decellularized aortic homografts showed excellent 97.8% 5-year survival and low endocarditis rates, though increases in transvalvular gradient and regurgitation occurred. Partial heart transplantation uses living valves from donor hearts and accommodates somatic growth. Postoperative immunosuppression in PHT is required but may be limited, as children and valve tissues may possess immune privilege, as evidenced by limited valve injury even in failed orthotopic heart transplants. In a pilot study of 19 infants, with a median follow-up of 26 weeks, increases in annular diameter and leaflet length were observed. Both PHT and TEHVs are promising valve replacement options. While PHT provides a growth-adaptive capability, TEHVs hold the potential for off-the-shelf solutions with minimal immunogenicity.
Surgical Management of Non‐Allergic Rhinitis—An EAACI Task Force Position Paper
Lundberg, Marie , Waterschoot, Julie van , Moyaert, Mathilde, Chaker, Adam, Gevaert, Philippe , Hagemann, Jan , Hox, Valérie, Kleijwegt, Maarten, Klimek, Ludger , Lal, Devyani, Maza‐Solano, J. , Pfaar, Oliver, Ryser, Fabio S. , Silva, Diana, Toppila‐Salmi, Sanna , Wikstén, Johanna , Reitsma, Sietze, Gerven, Laura Van , van Waterschoot, Julie , Ryser, Fabio Simon , Shiappoli, Michele , Toppila-Salmi, Sanna , Wikstén, Johanna , Van Gerven, Laura , Hox, Valérie , Kleijwegt, Maarten C. , Lal, Devyani , Pfaar, Oliver , Reitsma, Sietze

Mayo Clinic

Allergy | July 1, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/all.70424 | PMID 42385211 Get It

ABSTRACT Non‐allergic rhinitis is a frequent yet underdiagnosed cause of chronic nasal symptoms, including nasal congestion, rhinorrhoea, and upper airway hyperreactivity. Its pathophysiology involves neurogenic dysregulation, leading to excessive mucus production and vasodilation. While medical therapy remains first‐line, some patients experience persistent symptoms requiring surgical intervention. This review outlines key surgical options for refractory non‐allergic rhinitis: inferior turbinate (IT) reduction, vidian neurectomy, and posterior nasal nerve (PNN) ablation. IT reduction—performed using cold instruments, radiofrequency, laser, coblation, or microdebrider—remains the cornerstone treatment for nasal obstruction, offering durable symptom relief with low complication rates. Vidian neurectomy effectively reduces rhinorrhoea but carries risks of ocular dryness and transient facial numbness, limiting its indication to severe, refractory cases. PNN interventions, including cryotherapy, cold‐instrument techniques, and radiofrequency, provide a minimally invasive, outpatient alternative that selectively targets nasal parasympathetic and sensory fibers while sparing lacrimal innervation, yielding significant and lasting symptom improvement. Surgical management of non‐allergic rhinitis is effective and safe when tailored to symptom profile, anatomy, and prior medical treatment response. Advances in endoscopic and minimally invasive approaches have reduced complications, establishing these procedures as integral options in comprehensive non‐allergic rhinitis care.