Correcting the dynamic response of a commercial esophageal balloon-catheter
Cross, Troy J. , Beck, Kenneth C., Johnson, Bruce D. , Cross, Troy James

Mayo Clinic

Journal of Applied Physiology | July 12, 2016 | Volume: 121 | Issue: 2 | Pages: 503-511

10.1152/japplphysiol.00155.2016 | PMID 27402558 Get It

It is generally recommended that an esophageal balloon-catheter possess an adequate frequency response up to 15 Hz, such that parameters of respiratory mechanics may be quantified with precision. In our experience, however, we have observed that some commercially available systems do not display an ideal frequency response (<8-10 Hz). We therefore investigated whether the poor frequency response of a commercially available esophageal catheter may be adequately compensated using two numerical techniques: 1) an exponential model correction, and 2) Wiener deconvolution. These two numerical techniques were performed on a commercial balloon-catheter interfaced with 0, 1, and 2 lengths of extension tubing (90 cm each), referred to as configurations L0, L90, and L180, respectively. The frequency response of the balloon-catheter in these configurations was assessed by empirical transfer function analysis, and its “working” range was defined as the frequency beyond which more than 5% amplitude and/or phase distortion was observed. The working frequency range of the uncorrected balloon-catheter extended up to only 10 Hz for L0, and progressively worsened with additional tubing length (L90 = 3 Hz, L180 = 2 Hz). Although both numerical methods of correction adequately enhanced the working frequency range of the balloon-catheter to beyond 25 Hz for all length configurations (L0, L90, and L180), Wiener deconvolution consistently provided more accurate corrections. Our data indicate that Wiener deconvolution provides a superior correction of the balloon-catheter's dynamic response, and is relatively more robust to extensions in catheter tube length compared with the exponential correction method.
The Impact of Averaging Window Length on the “Desaturation” Indexes Obtained Via Overnight Pulse Oximetry at High Altitude
Cross, Troy J. , Keller‐Ross, Manda L. , Issa, Amine, Wentz, Robert J., Taylor, Bryan J. , Johnson, Bruce D. , Keller-Ross, Manda, Wentz, Robert, Cross, Troy James , Taylor, Bryan J , Keller-Ross, Manda

Mayo Clinic

Sleep | July 31, 2015 | Volume: 38 | Issue: 8 | Pages: 1331-1334

10.5665/sleep.4920 | PMID 25581919 Get It

Response characteristics of esophageal balloon catheters handmade using latex and nonlatex materials
Lalande, Sophie , Hyatt, Robert E., Johnson, Bruce D. , Cross, Troy J.

Mayo Clinic

Physiological Reports | June 16, 2015 | Volume: 3 | Issue: 6 | Pages: e12426

10.14814/phy2.12426 | PMID 26077619 Get It

Cardiorespiratory effects of inelastic chest wall restriction
Miller, Jordan D. , Beck, Kenneth C., Brice, A. G., Johnson, Bruce D., Joyner, Michael J. , Miller, Jordan

Mayo Clinic

Journal of Applied Physiology | March 3, 2015 | Volume: 92 | Issue: 6 | Pages: 2419-2428

10.1152/japplphysiol.00394.2001 | PMID 12015356 Get It

We examined the effects of chest wall restriction (CWR) on cardiorespiratory function at rest and during exercise in healthy subjects in an attempt to approximate the cardiorespiratory interactions observed in clinical conditions that result in restrictive lung and/or chest wall changes and a reduced intrathoracic space. Canvas straps were applied around the thorax and abdomen so that vital capacity was reduced by >35%. Data were acquired at rest and during cycle ergometry at 25 and 45% of peak workloads. CWR elicited significant increases in the flow-resistive work performed on the lung (160%) and the gastric pressure-time integral (>400%) at the higher workload, but it resulted in a decrease in the elastic work performed on the lung (56%) compared with control conditions. With CWR, heart rate increased and stroke volume (SV) fell, resulting in >10% fall in cardiac output at rest and during exercise at matched workloads ( P < 0.05). Blood pressure and catecholamines were significantly elevated during CWR exercise conditions ( P < 0.05). We conclude that CWR significantly impairs SV during exercise and that a compensatory increase in heart rate does not prevent a significant reduction in cardiac output. O2consumption appears to be maintained via increased extraction and a redistribution of blood flow via sympathetic activation.
The Psychological and Physiological Effects of Acute Occupational Stress in New Anesthesiology Residents
Eisenach, John H., Clark, Matthew M. , Johnson, Bruce D. , Kruse, Timothy N., Chantigian, Daniel P. , Carter, Jason R. , Long, Timothy R. , Šprung, Juraj , Shanafelt, Tait D. , Carter, Jason R

Mayo Clinic

Anesthesiology | August 5, 2014 | Volume: 121 | Issue: 4 | Pages: 878-893

10.1097/aln.0000000000000397 | PMID 25093592 Get It

Abstract Background: Occupational stress in resident physicians has profound implications for wellness, professionalism, and patient care. This observational pilot trial measured psychological and physiological stress biomarkers before, during, and after the start of anesthesia residency. Methods: Eighteen physician interns scheduled to begin anesthesia residency were recruited for evaluation at three time points: baseline (collected remotely before residency in June 2013); first-month visit 1 (July); and follow-up visit 2 (residency months 3 to 5, September–November). Validated scales were used to measure stress, anxiety, resilience, and wellness at all three time points. During visits 1 and 2, the authors measured resting heart-rate variability, responses to laboratory mental stress (hemodynamic, catecholamine, cortisol, and interleukin-6), and chronic stress indices (C-reactive protein, 24-h ambulatory heart rate and blood pressure, 24-h urinary cortisol and catecholamines, overnight heart-rate variability). Results: Thirteen interns agreed to participate (72% enrollment). There were seven men and six women, aged 27 to 33 yr. The mean ± SD of all study variables are reported. Conclusion: The novelty of this report is the prospective design in a defined cohort of residents newly exposed to the similar occupational stress of the operating environment. Because of the paucity of literature specific to the measures and stress conditions in this investigation, no data were available to generate a priori definition of primary outcomes and a data analytic plan. These findings will allow power analysis for future design of trials examining occupational stress and stress-reducing interventions. Given the importance of physician burnout in our country, the impact of chronic stress on resident wellness requires further study.
Importance of the Kidney, Vessels, and Heart with Administration of β2 Adrenergic Receptor Agonists in Patients Susceptible to Acute Respiratory Distress Syndrome
Snyder, Eric M., Johnson, Bruce D.

Mayo Clinic

American Journal of Respiratory and Critical Care Medicine | June 1, 2014 | Volume: 189 | Issue: 11 | Pages: 1445-1447

10.1164/rccm.201404-0610le | PMID 24881947 Get It

Influence of locomotor muscle afferent inhibition on the ventilatory response to exercise in heart failure
Olson, Thomas P. , Joyner, Michael J. , Eisenach, John H., Curry, Timothy B. , Johnson, Bruce D. , Joyner, Michael J

Mayo Clinic

Experimental Physiology | October 26, 2013 | Volume: 99 | Issue: 2 | Pages: 414-426

10.1113/expphysiol.2013.075937 | PMID 24163425 Get It

New FindingsWhat is the central question of this study?Patients with heart failure often develop ventilatory abnormalities at rest and during exercise, but the mechanisms underlying these abnormalities remain unclear. This study investigated the influence of inhibiting afferent neural feedback from locomotor muscles on the ventilatory response during exercise in heart failure patients.What is the main finding and its importance?Our results suggest that inhibiting afferent feedback from locomotor muscle via intrathecal opioid administration significantly reduces the ventilatory response to exercise in heart failure patients.Patients with heart failure (HF) develop ventilatory abnormalities at rest and during exercise, but the mechanism(s) underlying these abnormalities remain unclear. We examined whether the inhibition of afferent neural feedback from locomotor muscles during exercise reduces exercise ventilation in HF patients. In a randomized, placebo‐controlled design, nine HF patients (age, 60 ± 2 years; ejection fraction, 27 ± 2%; New York Heart Association class 2 ± 1) and nine control subjects (age, 63 ± 2 years) underwent constant‐work submaximal cycling (65% peak power) with intrathecal fentanyl (impairing the cephalad projection of opioid receptor‐sensitive afferents) or sham injection. The hypercapnic ventilatory response was measured to determine whether cephalad migration of fentanyl occurred. There were no differences in hypercapnic ventilatory response within or between groups in either condition. Despite a lack of change in ventilation, tidal volume or respiratory rate, HF patients had a mild increase in arterial carbon dioxide () and a decrease in oxygen (;P< 0.05 for both) at rest. The control subjects demonstrated no change in,, ventilation, tidal volume or respiratory rate at rest. In response to fentanyl during exercise, HF patients had a reduction in ventilation (63 ± 6versus44 ± 3 l min−1,P< 0.05) due to a lower respiratory rate (30 ± 1versus26 ± 2 breaths min−1,P< 0.05). The reduced ventilation resulted in lower(97.6 ± 2.5versus79.5 ± 3.0 mmHg,P< 0.05) and increased(37.3 ± 0.9versus43.5 ± 1.1 mmHg,P< 0.05), with significant improvement in ventilatory efficiency (reduction in the ventilatory equivalent for carbon dioxide;P< 0.05 for all). The control subjects had no change in ventilation or measures of arterial blood gases. These data suggest that inhibition of afferent feedback from locomotor muscle significantly reduces the ventilatory response to exercise in HF patients.
Use of Noninvasive Gas Exchange to Track pulmonary Vascular Responses to exercise in Heart Failure
Taylor, Bryan J. , Olson, Thomas P. , Chul-Ho-Kim, MacCarter, Dean, Johnson, Bruce D. , Taylor, Bryan J

Mayo Clinic

Clinical Medicine Insights: Circulatory, Respiratory and Pulmonary Medicine | September 22, 2013 | Volume: 7 | Issue: No issue available | Pages: CCRPM.S12178

10.4137/ccrpm.s12178 | PMID 24093002 Get It

We determined whether a non-invasive gas exchange based estimate of pulmonary vascular (PV) capacitance [PV CAP = stroke volume (SV) x pulmonary arterial pressure (Ppa)] (GX CAP ) tracked the PV response to exercise in heart-failure (HF) patients. Pulmonary wedge pressure (Ppw), Ppa, PV resistance (PVR), and gas exchange were measured simultaneously during cycle exercise in 42 HF patients undergoing right-heart catheterization. During exercise, P ET CO 2 and V E /VCO 2 were related to each other ( r= -0.93, P < 0.01) and similarly related to mean Ppa (mPpa) ( r = -0.39 and 0.36; P < 0.05); P ET CO 2 was subsequently used as a metric of mPpa. Oxygen pulse (O 2 pulse) tracked the SV response to exercise (r = 0.91, P < 0.01). Thus, GX CAP was calculated as O 2 pulse x P ET CO 2 . During exercise, invasively determined PV CAP and non-invasive GX CAP were related (r = 0.86, P < 0.01), and GX CAP correlated with mPpa and PVR (r = -0.46 and -0.54; P < 0.01). In conclusion, noninvasive gas exchange measures may represent a simple way to track the PV response to exercise in HF.
Energy Expenditure and Intensity Levels During a 6170-m Summit in the Karakoram Mountains
Taylor, Bryan J. , Johnson, Bruce D. , Miller, Andrew David , Taylor, Bryan J

Mayo Clinic

Wilderness & Environmental Medicine | September 13, 2013 | Volume: 24 | Issue: 4 | Pages: 337-344

10.1016/j.wem.2013.06.009 | PMID 24041623 Get It

Objective Although the majority of high altitude studies have used doubly labeled water to assess energy expenditure (EE), minimal research has examined variation in intensity levels while participating in such an expedition. The purpose of this study was to use ambulatory monitoring technology to assess EE and time spent in moderate (3.0–6.0 METS), vigorous (6.0–9.0 METS), and very vigorous (>9.0 METS) intensities during an expedition to summit a 6170-m peak in Northern Pakistan. Methods Twelve men and 2 women were studied. Their EE was determined from galvanic skin response, heat flux, and biaxial accelerometry using a multisensor armband. Lake Louise Scores for altitude illness assessment were obtained each morning. Results Average daily total EE and number of steps taken was 4173 ± 848 kcal/d (range, 3332 to 4838 kcal/d) and 26,232 ± 7210 steps/d (range, 11,788 to 34,979 steps/d), respectively. On average, subjects spent approximately 7.7 h/d performing physical activity (>3.0 METS). Of this, subjects spent 399 ± 107, 61 ± 77, and 3 ± 10 min/d at moderate, vigorous, and very vigorous intensity levels, respectively, corresponding to 88%, 11%, and 1% of total physical activity time. During summit day, subjects climbed at an intensity equivalent to approximately 42% of their high altitude predicted maximal oxygen consumption at 5100 m). Conclusions During a high altitude expedition, subjects predominantly exercise at a moderate intensity, with limited time spent at higher intensity levels. Use of accelerometer-based technology may provide more cost-effective and logistically easier means of assessing EE in extreme environments.