Citations

Clear

2117 citation(s) found for "Mayo, Steven".

Practical Immunocytochemical Identification of Human Blood Cells
Li, Chin‐Yang, Ziesmer, Steven C., Yam, Lung T., English, Mary C., Janckila, Anthony J.

Mayo Clinic

American Journal of Clinical Pathology | March 18, 2016 | Volume: 81 | Issue: 2 | Pages: 204-212

10.1093/ajcp/81.2.204 | PMID 6230002 Get It

Long‐term outcome of patients with POEMS syndrome: An update of the Mayo Clinic experience
Kourelis, Taxiarchis , Kumar, Shaji , Lacy, Martha Q. , Dingli, David , Go, Ronald S. , Kapoor, Prashant , Lust, John A., Hayman, Suzanne R. , Hwa, Yi L. , Zeldenrust, Steven R., Russell, Stephen J. , Lin, Yi , Kyle, Robert A. , Dispenzieri, Angela , Kourelis, Taxiarchis V, Buadi, Francis K. , Go, Ronald S , Hwa, Yi, Gertz, Morie A. , Rajkumar, S. Vincent , Leung, Nelson , Gonsalves, Wilson I. , Dispenzieri, Angela , Russell, Stephen J , Dingli, David , Lin, Yi

Mayo Clinic

American Journal of Hematology | March 14, 2016 | Volume: 91 | Issue: 6 | Pages: 585-589

10.1002/ajh.24356 | PMID 26972803 Get It

Over the past decade, a number of changes have occurred in the diagnostic evaluation, management, and long‐term follow‐up of patients with POEMS syndrome at our institution. This study included 291 patients with POEMS syndrome diagnosed at the Mayo Clinic between 1974 and 2014. Patients diagnosed after 2003 had more features of the syndrome identified at diagnosis and were more likely to receive an autologous transplant (49% versus 8%, P < 0.0001) and to have achieved a hematologic complete response (CR) to treatment (41% vs 25%, P < 0.0001). With 2273 person‐years of follow‐up, 10‐year overall survival (OS) was 62% (95% C.I., 56%, 67%). On multivariate analysis, the three factors associated with superior OS were younger age (RR 0.98 [0.96–1.00]), albumin greater‐than 3.2 g/dL (RR 0.5 [0.32–0.89]) and attainment of complete hematologic response (RR 0.4 [0.2, 0.9]). This study confirms the very good long‐term outcomes of patients with POEMS syndrome and identifies two new prognostic risk factors: albumin at diagnosis and attainment of complete hematologic response. Am. J. Hematol. 91:585–589, 2016. © 2016 Wiley Periodicals, Inc.
Reduction in C‐reactive protein indicates successful targeting of the IL‐1/IL‐6 axis resulting in improved survival in early stage multiple myeloma
Lust, John A., Lacy, Martha Q. , Zeldenrust, Steven R., Moon‐Tasson, Laurie L., Dinarello, Charles A. , Donovan, Kathleen A., Moon-Tasson, Laurie L, Witzig, Thomas E.

Mayo Clinic

American Journal of Hematology | March 6, 2016 | Volume: 91 | Issue: 6 | Pages: 571-574

10.1002/ajh.24352 | PMID 26945843 Get It

We report the long‐term follow‐up results of a phase II trial of IL‐1 receptor antagonist and low‐dose dexamethasone for early stage multiple myeloma (MM). Patients were eligible if they had smoldering multiple myeloma (SMM) or indolent multiple myeloma (IMM) without the need for immediate therapy. Forty seven patients were enrolled and subsequently treated with IL‐1Ra; in 25/47 low‐dose dexamethasone (20 mg weekly) was added. The primary endpoint was progression‐free survival (PFS). In the clinical trial, three patients achieved a minor response (MR) to IL‐1Ra alone; five patients a partial response (PR) and four patients an MR after addition of dexamethasone. Seven patients showed a decrease in the plasma cell labeling index (PCLI) which paralleled a decrease in the high sensitivity C‐reactive protein (hs‐CRP). The median PFS for the 47 patients was 1116 days (37.2 months). The median PFS for patients without (n = 22) and with (n = 25) a decrease in their baseline hs‐CRP was 326 days (11 months) vs. 3139 days (104 months) respectively (P <0.0001). The median overall survival (OS) for the 47 patients was 3482 days (9.5 years). The median OS for patients without and with a decrease in their baseline hs‐CRP was 2885 days (7.9 years) vs. median not reached, respectively (P = 0.001). In SMM/IMM patients at risk for progression to active myeloma, reduction in the hs‐CRP indicates successful targeting of the IL‐1/IL‐6 axis resulting in improved PFS and OS.(Clinical Trials.gov Identifier: NCT00635154) Am. J. Hematol. 91:571–574, 2016. © 2016 Wiley Periodicals, Inc.
Tailoring through Technology: A Retrospective Review of a Single Surgeon's Experience with Implant-Based Breast Reconstruction before and after Implementation of Laser-Assisted Indocyanine Green Angiography
Harless, Christin A., Jacobson, Steven R.

Mayo Clinic

The Breast Journal | February 22, 2016 | Volume: 22 | Issue: 3 | Pages: 274-281

10.1111/tbj.12576 | PMID 26899399 Get It

Development and Validation of HealthImpact: An Incident Diabetes Prediction Model Based on Administrative Data
Nori, Vijay S. , Smith, Steven A., Hane, Christopher A. , McCoy, Rozalina G.

Mayo Clinic

Health Services Research | February 21, 2016 | Volume: 51 | Issue: 5 | Pages: 1896-1918

10.1111/1475-6773.12461 | PMID 26898782 Get It

Objective To develop and validate a model of incident type 2 diabetes based solely on administrative data. Data Sources/Study Setting Optum Labs Data Warehouse (OLDW), a national commercial administrative dataset. Study Design HealthImpact model was developed and internally validated using nested case–control study design; n = 473,049 in training cohort and n = 303,025 in internal validation cohort. HealthImpact was externally validated in 2,000,000 adults followed prospectively for 3 years. Only adults ≥18 years were included. Data Collection/Extraction Methods Patients with incident diabetes were identified using HEDIS rules. Control subjects were sampled from patients without diabetes. Medical and pharmacy claims data collected over 3 years prior to index date were used to build the model variables. Principal Findings HealthImpact, scored 0–100, has 48 variables with c‐statistic 0.80815. We identified HealthImpact threshold of 90 as identifying patients at high risk of incident diabetes. HealthImpact had excellent discrimination in external validation cohort (c‐statistic 0.8171). The sensitivity, specificity, positive predictive value, and negative predictive value of HealthImpact >90 for new diagnosis of diabetes within 3 years were 32.35, 94.92, 22.25, and 96.90 percent, respectively. Conclusions HealthImpact is an efficient and effective method of risk stratification for incident diabetes that is not predicated on patient‐provided information or laboratory tests.
Determinants of Early Mortality Among 37,568 Patients With Colon Cancer Who Participated in 25 Clinical Trials From the Adjuvant Colon Cancer Endpoints Database
Renfro, Lindsay A. , Kerr, David , Gramont, Aimery de , André, Thierry , Guthrie, Katherine A. , Labianca, Roberto , Francini, Guido, Seitz, J. F., O’Callaghan, Chris J. , Twelves, Chris , Haller, Daniel G. , Yothers, Greg , Cheung, Winson Y, de Gramont, Aimery, Saltz, Leonard B. , O'Callaghan, Chris, van Cutsem, Eric, Cheung, Winson Y. , Grothey, Axel , Alberts, Steven R. , Cutsem, Eric Van , Sargent, Daniel J. , André, Thierry , Yothers, Greg

Mayo Clinic

Journal of Clinical Oncology | February 9, 2016 | Volume: 34 | Issue: 11 | Pages: 1182-1189

10.1200/jco.2015.65.1158 | PMID 26858337 Get It

Purpose Factors associated with early mortality after surgery and treatment with adjuvant chemotherapy in colon cancer are poorly understood. We aimed to characterize the determinants of early mortality in a large cohort of colon cancer trial participants. Methods A pooled analysis of 37,568 patients in 25 randomized trials of adjuvant systemic therapy was conducted. Multivariable logistic regression models with several definitions of early mortality (30, 60, and 90 days, and 6 months) were constructed, adjusting for clinically and statistically significant variables. A nomogram for 6-month mortality was developed and validated. Results Median age among patients was 61 years, patient demographics included 54% men and 90% White, 29% and 71% had stage II and III disease, respectively, and 79%, 20%, and 1% had an Eastern Cooperative Oncology Group performance status (PS) of 0, 1, and ≥ 2, respectively. Early mortality was low: 0.3% at 30 days, 0.6% at 60 days, 0.8% at 90 days, and 1.4% at 6 months. Of those patients who died by 6 months post–random assignment, 40% had documented disease recurrence prior to death. Early disease recurrence was associated with a markedly increased risk of death during the first 6 months post-treatment (hazard ratio, 82.6; 95%CI, 66.9 to 102.1). In prognostic analyses, advanced age, male sex, poorer PS, increasing ratio of positive to examined lymph nodes, earlier decade of enrollment, and higher tumor stage and grade predicted a greater likelihood of early mortality, whereas treatment received was not strongly predictive. A multivariable model for 6-month mortality showed strong optimism-adjusted discrimination (concordance index, 0.73) and calibration. Conclusion Early mortality was infrequent but more prevalent in patients with advanced age and a PS of ≥ 2, underscoring the need to carefully consider the risk-to-benefit ratio when making treatment decisions in these subgroups.
Clinical characteristics and outcomes in biclonal gammopathies
Mullikin, Trey C. , Dispenzieri, Angela , Lacy, Martha Q. , Lin, Yi , Dingli, David , Go, Ronald S. , Hayman, Suzanne R. , Zeldenrust, Steven R., Russell, Stephen J. , Lust, John A., Kapoor, Prashant , Kyle, Robert A. , Kumar, Shaji , Buadi, Francis K. , Rajkumar, S. Vincent , Leung, Nelson , Gertz, Morie A. , Go, Ronald S , Dispenzieri, Angela , Russell, Stephen J , Dingli, David , Lin, Yi

Mayo Clinic

American Journal of Hematology | February 3, 2016 | Volume: 91 | Issue: 5 | Pages: 473-475

10.1002/ajh.24319 | PMID 26840395 Get It

A single monoclonal protein typically characterizes monoclonal gammopathies, but a small proportion may have more than one M protein identifiable. In the setting of symptomatic multiple myeloma (MM), the development of a new monoclonal protein following therapy is associated with better outcomes. As for the precursor conditions, monoclonal gammopathy undetermined significance (MGUS) and smoldering multiple myeloma (SMM), there is limited information on the impact of a second monoclonal protein on the disease course, including progression and response to treatment. The outcomes of patients with MGUS and SMM with more than one monoclonal protein, after identifying 539 patients with biclonal proteins on electrophoresis and/or immunofixation, were reported. About 22 of 393 patients with MGUS/biclonal gammopathy of undetermined significance (BGUS) progressed to SMM (6), MM (11), AL (3), or WM (2), and 5 of 16 patients with biclonal SMM progressed to MM. The rate of progression for BGUS was approximately 1% per year, which is similar to MGUS with one monoclonal protein. The median estimated time of progression of biclonal SMM was 2.6 years; similar to monoclonal SMM. For patients with biclonal MM, both M spikes responded to treatment and, upon relapse, the original dominant M protein remained dominant as the disease progressed. In conclusion, the presence of a second monoclonal protein does not appear to affect the progression of precursor states and suggests multiple monoclonal proteins do not clinically impact one another in the course of the disease. Am. J. Hematol. 91:473–475, 2016. © 2016 Wiley Periodicals, Inc.
Evaluation of conventional imaging performance in a research whole-body CT system with a photon-counting detector array
Yu, Zhicong , Jorgensen, Steven M., Li, Zhoubo , Gutjahr, Ralf , Chen, Baiyu , Halaweish, Ahmed F., Kappler, S. , Yu, Lifeng , Ritman, Erik L., Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H.

Mayo Clinic

Physics in Medicine & Biology | February 2, 2016 | Volume: 61 | Issue: 4 | Pages: 1572-1595

10.1088/0031-9155/61/4/1572 | PMID 26835839 Get It

Abstract This study evaluated the conventional imaging performance of a research whole-body photon-counting CT system and investigated its feasibility for imaging using clinically realistic levels of x-ray photon flux. This research system was built on the platform of a 2nd generation dual-source CT system: one source coupled to an energy integrating detector (EID) and the other coupled to a photon-counting detector (PCD). Phantom studies were conducted to measure CT number accuracy and uniformity for water, CT number energy dependency for high-Z materials, spatial resolution, noise, and contrast-to-noise ratio. The results from the EID and PCD subsystems were compared. The impact of high photon flux, such as pulse pile-up, was assessed by studying the noise-to-tube-current relationship using a neonate water phantom and high x-ray photon flux. Finally, clinical feasibility of the PCD subsystem was investigated using anthropomorphic phantoms, a cadaveric head, and a whole-body cadaver, which were scanned at dose levels equivalent to or higher than those used clinically. Phantom measurements demonstrated that the PCD subsystem provided comparable image quality to the EID subsystem, except that the PCD subsystem provided slightly better longitudinal spatial resolution and about 25% improvement in contrast-to-noise ratio for iodine. The impact of high photon flux was found to be negligible for the PCD subsystem: only subtle high-flux effects were noticed for tube currents higher than 300 mA in images of the neonate water phantom. Results of the anthropomorphic phantom and cadaver scans demonstrated comparable image quality between the EID and PCD subsystems. There were no noticeable ring, streaking, or cupping/capping artifacts in the PCD images. In addition, the PCD subsystem provided spectral information. Our experiments demonstrated that the research whole-body photon-counting CT system is capable of providing clinical image quality at clinically realistic levels of x-ray photon flux.
Dual-Energy CT for Evaluation of Intra- and Extracapsular Silicone Implant Rupture
Glazebrook, Katrina N. , Jacobson, Steven R., McCollough, Cynthia M., Leng, Shuai

Mayo Clinic

Case Reports in Radiology | January 28, 2016 | Volume: 2016 | Issue: No issue available | Pages: 1-4

10.1155/2016/6323709 | PMID 26942031 Get It

Silicone implants are commonly used for both breast augmentation and breast reconstruction. With aging of the implant, the silicone envelope may become weak or may rupture. The technique of choice for evaluation of implant integrity is breast MRI; however this may be contraindicated in some patients or the cost may be prohibitive. Dual-energy CT allows determination of density and atomic number of tissue and can provide material composition information. We present a case of extracapsular implant rupture with MRI and dual-energy CT imaging and surgical correlation.
Human Imaging With Photon Counting–Based Computed Tomography at Clinical Dose Levels
Gutjahr, Ralf , Halaweish, Ahmed F., Yu, Zhicong , Yu, Lifeng , Li, Zhoubo , Jorgensen, Steven M., Ritman, Erik L., Kappler, S. , Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H.

Mayo Clinic

Investigative Radiology | January 27, 2016 | Volume: 51 | Issue: 7 | Pages: 421-429

10.1097/rli.0000000000000251 | PMID 26818529 Get It

Objectives The purpose of this work was to measure and compare the iodine contrast-to-noise ratio (CNR) between a commercial energy-integrating detector (EID) computed tomography (CT) system and a photon-counting detector (PCD) CT scanner capable of human imaging at clinical dose rates, as well as to determine clinical feasibility using human cadavers. Materials and Methods A research dual-source PCD-CT scanner was used, where the “A” tube/detector subsystem used an EID and the “B” tube/detector subsystem used a PCD. Iodine CNR was measured in 4 anthropomorphic phantoms, simulating 4 patient sizes, at 4 tube potential settings. After biospecimen committee approval, PCD scans were performed on a fresh-frozen human head and a whole-body cadaver using clinical dose rates. Scans were repeated using the EID and identical parameters, and qualitative side-by-side comparisons were performed. Results For the same photon fluence, phantom measurements demonstrated a mean increase in CNR of 11%, 23%, 31%, 38% for the PCD system, relative to the EID system, at 80, 100, 120, and 140 kV, respectively. Photon-counting detector CT additionally provided energy-selective imaging, where low- and high-energy images reflected the energy dependence of the iodine signal. Photon-counting detector images of cadaveric anatomy demonstrated decreased beam hardening and calcium blooming in the high-energy bin images and increased contrast in the low-energy bins images relative to the EID images. Threshold-based PCD images were qualitatively deemed equivalent in other aspects. Conclusions The evaluated research PCD-CT system was capable of clinical levels of image quality at clinical dose rates. It further provided improved CNR relative to state-of-the-art EID-CT. The energy-selective bin images provide further opportunity for dual-energy and multienergy analyses.