Thirty-Day Outcomes of Transcatheter Mitral Valve Replacement for Degenerated Mitral Bioprostheses (Valve-in-Valve), Failed Surgical Rings (Valve-in-Ring), and Native Valve With Severe Mitral Annular Calcification (Valve-in-Mitral Annular Calcification) in
Vemulapalli, Sreekanth , Xiang, Qun, Wang, Dee Dee , Eleid, Mackram F. , Sandhu, Gurpreet S. , Salinger, Michael H., Russell, Hyde M., Kodali, Susheel , Dvir, Danny , Russo, Mark J., Fang, Kenith, Coylewright, Megan , Shah, Pinak , Babaliaros, Vasilis , Khan, Jaffar M. , Tommaso, Carl L. , Saucedo, Jorge , Makkar, Rajj, Mack, Michael J. , Holmes, David R. , Leon, Martin B. , Bapat, Vinayak , Thourani, Vinod H. , Rihal, Charanjit S. , O’Neill, William, Feldman, Ted , Douglas, Pamela S. , Eleid, Mackram, Cabalka, Allison K. , Rihal, Charanjit, Wang, Dee Dee , Douglas, Pamela S , Guerrero, Mayra , Greenbaum, Adam B. , George, Isaac , Whisenant, Brian K. , Pershad, Ashish , Shah, Pinak , Kar, Saibal , Makkar, Raj , Rihal, Charanjit S.

Mayo Clinic

Circulation: Cardiovascular Interventions | March 6, 2020 | Volume: 13 | Issue: 3 | Pages: No page available

10.1161/circinterventions.119.008425 | PMID 32138529 Get It

Background: Transcatheter mitral valve replacement using aortic transcatheter heart valves has recently become an alternative for patients with degenerated mitral bioprostheses, failed surgical repairs with annuloplasty rings or severe mitral annular calcification who are poor surgical candidates. Outcomes of these procedures are collected in the Society of Thoracic Surgeons/American College of Cardiology/Transcatheter Valve Therapy Registry. A comprehensive analysis of mitral valve-in-valve (MViV), mitral valve-in-ring (MViR), and valve-in-mitral annular calcification (ViMAC) outcomes has not been performed. We sought to evaluate short-term outcomes of early experience with MViV, MViR, and ViMAC in the United States. Methods: Retrospective analysis of data from the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. Results: Nine hundred three high-risk patients (median Society of Thoracic Surgeons score 10%) underwent MViV (n=680), MViR (n=123), or ViMAC (n=100) between March 2013 and June 2017 at 172 hospitals. Median age was 75 years, 59.2% female. Technical and procedural success were higher in MViV. Left ventricular outflow tract obstruction occurred more frequently with ViMAC (ViMAC=10%, MViR=4.9%, MViV=0.7%; P <0.001). In-hospital mortality (MViV=6.3%, MViR=9%, ViMAC=18%; P =0.004) and 30-day mortality (MViV=8.1%, MViR=11.5%, ViMAC=21.8%; P =0.003) were higher in ViMAC. At 30-day follow-up, median mean mitral valve gradient was 7 mm Hg, most patients (96.7%) had mitral regurgitation grade ≤1 (+) and were in New York Heart Association class I to II (81.7%). Conclusions: MViV using aortic balloon-expandable transcatheter heart valves is associated with a low complication rate, a 30-day mortality lower than predicted by the Society of Thoracic Surgeons score, and superior short-term outcomes than MViR and ViMAC. At 30 days, patients in all groups experienced improvement of symptoms, and valve performance remained stable. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02245763.
Left ventricular filling pressure and survival following aortic valve replacement for severe aortic stenosis
Thaden, Jeremy J. , Balakrishnan, Mahesh, Sánchez, José Javier, Adigun, Rosalyn , Nkomo, Vuyisile T. , Eleid, Mackram F. , Scott, Christopher G. , Oh, Jae K. , Pellikka, Patricia A. , Sanchez, Jose , Eleid, Mackram, Dahl, Jordi, Scott, Christopher , Pislaru, Sorin, Schaff, Hartzell, Pellikka, Patricia A , Nkomo, Vuyisile T , Balakrishnan, Mahesh, Sanchez, Jose, Dahl, Jordi S. , Pislaru, Sorin V. , Schaff, Hartzell V.

Mayo Clinic

Heart | February 17, 2020 | Volume: 106 | Issue: 11 | Pages: 830-837

10.1136/heartjnl-2019-315908 | PMID 32066613 Get It

Objective To determine whether echocardiography-derived left ventricular filling pressure influences survival in patients with severe aortic stenosis (AS) undergoing aortic valve replacement (AVR). Methods We retrospectively reviewed 1383 consecutive patients with severe AS, normal ejection fraction and interpretable filling pressure undergoing AVR. Left ventricular filling pressure was determined according to current guidelines using mitral inflow, mitral annular tissue Doppler, estimated right ventricular systolic pressure and left atrial volume index. Cox proportional hazards regression was used to assess the influence of various parameters on mortality. Results Age was 75±10 years and 552 (40%) were female. Left ventricular filling pressure was normal in 325 (23%), indeterminate in 463 (33%) and increased in 595 (43%). Mean follow-up was 7.3±3.7 years, and mortality was 1.2%, 4.2% and 18.9% at 30 days and 1 and 5 years, respectively. Compared with patients with normal filling pressure, patients with increased filling pressure were older (78±9 vs 70±12, p<0.001), more often female (45% vs 35%, p=0.002) and were more likely to have New York Heart Association class III–IV symptoms (35% vs 24%, p=0.004), coronary artery disease (55% vs 42%, p<0.001) and concentric left ventricular hypertrophy (63% vs 37%, p<0.001). After correction for other factors, increased left ventricular filling pressure remained an independent predictor of mortality after successful AVR (adjusted HR 1.45 (95% CI 1.16 to 1.81), p=0.005). Conclusions Preoperative increased left ventricular filling pressure is common in patients with AS undergoing AVR and has important prognostic implications, regardless of symptom status. Future prospective studies should consider whether patients with increased filling pressure would benefit from earlier operation.
Hemodynamics rounds: Hemodynamics of mitral valve interventions
Lloyd, James W. , Rihal, Charanjit S. , Eleid, Mackram F. , Lloyd, James , Rihal, Charanjit S.

Mayo Clinic

Catheterization and Cardiovascular Interventions | February 8, 2020 | Volume: 96 | Issue: 3 | Pages: 712-724

10.1002/ccd.28755 | PMID 32034874 Get It

AbstractMitral valvulopathy presents as regurgitation, stenosis, or mixed disease and can occur in both native and prosthetic valves. Such disease develops in conjunction with pathophysiologic changes in the left atrium (LA) and drives changes in LA compliance, pressure, and thus clinical syndromes. With advances in the understanding and treatment of structural heart disease and in the setting of higher‐risk patient populations, less‐invasive transcatheter approaches have become increasingly commonplace in the treatment of mitral valve disease. Over time, transcatheter mitral valve interventions have evolved to include paravalvular leak closure, mitral valve repair, and mitral valve replacement. Parallel to this evolution, advances in invasive intracardiac pressure monitoring, particularly at the level of the LA, have also occurred. These advances emphasize the unique interplay between mitral valve disease and LA function; account for limitations of noninvasive assessment; and guide beneficial outcomes in each area of transcatheter mitral valve intervention. As a result, continuous transseptal LA pressure monitoring has developed into an indispensable instrument in successful percutaneous mitral valve intervention, complementing traditional noninvasive assessment.
Characteristics and outcomes of patients with normal left atrial pressure undergoing transcatheter mitral valve repair
Sims, Jason R. , Reeder, Guy S., Nkomo, Vuyisile T. , Nishimura, Rick A., Rihal, Charanjit S. , Eleid, Mackram F. , Nkomo, Vuyisile T , Nishimura, Rick , Guerrero, Mayra , Alkhouli, Mohamad , Rihal, Charanjit S.

Mayo Clinic

Heart | January 24, 2020 | Volume: 106 | Issue: 12 | Pages: 898-903

10.1136/heartjnl-2019-316133 | PMID 31980440 Get It

Objective A subset of patients at the time of transcatheter mitral valve repair (TMVR) will have normal left atrial pressure (LAP) (<13 mm Hg) despite having severe mitral regurgitation (MR). The goal of this study was to determine clinical characteristics and outcomes in patients with normal LAP undergoing TMVR. Methods A single-centre retrospective cohort of consecutive patients who underwent transcatheter edge-to-edge mitral valve clip and continuous LAP monitoring between 5/1/2014 and 5/1/2018 was analysed. One-year mortality was compared by Kaplan–Meier survival curves. Multivariable analysis was performed to identify predictors of normal LAP and 1 year mortality. Results Of the 204 patients undergoing TMVR, 65% were men and the mean age was 81. Of these patients, 31 (15%) had normal LAP (mean LAP 10.5 mm Hg, mean V wave 16.5 mm Hg) and 173 had elevated LAP (mean LAP 19 mm Hg, mean V wave 32.5 mm Hg). The prevalence of severe MR was not different between groups, although the normal LAP group had significantly lower effective regurgitant orifice area and regurgitant volume. Other notable baseline characteristics including prior cardiac surgery, atrial fibrillation, hypertension, diabetes, congestive heart failure, body mass index, mechanism of MR and ejection fraction were similar between groups. However, there was an increased prevalence of chronic lung disease (CLD) (45.2% vs 17.3%, p<0.001) in the normal LAP group. On multivariate analysis, the only significant predictor of normal LAP was the presence of CLD (OR 4.79 (1.83–12.36), p=0.001) and 1-year mortality was significantly higher in the normal LAP group (32.3% vs 12.7%, p=0.006). After adjustment for comorbidities, normal LAP was no longer a predictor of 1-year mortality (RR 1.62 (0.64–4.06), p=0.32); however, CLD (RR 3.44 (1.37–8.67), p=0.01) remained a statistically significant predictor. Conclusion Normal LAP at the time of TMVR is associated with a higher incidence of CLD which independently predicts increased 1-year mortality. In patients with CLD and apparently severe MR, measurement of LAP may help identify those with lower likelihood of benefit from TMVR.
Temporal Occurrence of Arrhythmic Complications After Alcohol Septal Ablation
El‐Sabawi, Bassim , Barsness, Gregory W. , Cha, Yong‐Mei , Geske, Jeffrey B. , Eleid, Mackram F. , Geske, Jeffrey B , Nishimura, Rick A.

Mayo Clinic

Circulation: Cardiovascular Interventions | January 24, 2020 | Volume: 13 | Issue: 2 | Pages: No page available

10.1161/circinterventions.119.008540 | PMID 31973555 Get It

Background: The temporal occurrence of arrhythmic complications after alcohol septal ablation (ASA) is unclear. As a result, the appropriate time to monitor patients after ASA is controversial. The purpose of this study is to determine the temporal occurrence of complete heart block (CHB) and ventricular tachyarrhythmia (VT) after ASA to better understand when patients can be safely discharged. Methods: Consecutive patients treated with ASA for hypertrophic cardiomyopathy from 2003 to 2019 at a tertiary referral center were reviewed retrospectively. The incidence and timing of CHB or sustained VT within 30 days post-ASA were assessed. Results: A total of 243 patients were included in this study. Mean maximal septal thickness was 19.0±3.9 mm, and total volume of ethanol injected was 1.7±0.6 mL. CHB occurred in 59 (24.3%) patients, including transient CHB in 33 (13.6%) and permanent in 26 (10.7%). The initial episode of CHB occurred within 24 hours post-ASA in 51 (21.0%) patients, between 24 and 48 hours in 3 (1.2%), between 48 and 72 hours in 3 (1.2%), and after 72 hours in 2 (0.8%). New permanent pacemaker was placed in 46 (18.3%). Presence of baseline bundle branch block and age ≥70 were significantly associated with CHB but not CHB presenting after 24 hours. VT occurred in 3 (1.2%) patients, including 1 (0.4%) within 24 hours, 1 (0.4%) between 24 and 48 hours, and 1 (0.4%) after 72 hours. VT required cardioversion in 2 patients and new implantable cardioverter-defibrillator placement in 2. Conclusions: The incidence of CHB or VT presenting after 72 hours post-ASA was low. These findings suggest that timely discharge of patients without evidence of early conduction disturbances after ASA can be considered as a potentially safe management strategy, especially in patients without preexisting conduction abnormalities.
P339 Gradient adjusted cardiac power index does not improve prediction of survival post transcatheter aortic valve replacement compared to cardiac power index alone
Mookadam, Farouk , Venepally, Nithin R. , Wang, P, Khetarpal, Banveet Kaur , Sweeney, Joseph C. , Eleid, M, Pollak, Peter , Fortuin, F. David , Holmes, David R. , Agasthi, Pradyumna , Mookadam, Farouk , Sweeney, J, Arsanjani, Reza

Mayo Clinic

European Heart Journal - Cardiovascular Imaging | January 17, 2020 | Volume: 21 | Issue: Supplement_1 | Pages: No page available

10.1093/ehjci/jez319.192 Get It

Abstract Funding Acknowledgements None Background Cardiac Power Index (CPI) is an integrative hemodynamic measure of cardiac pumping capability and is the product of the simultaneously measured mean arterial pressure (MAP) and cardiac output (CO). In patients with aortic stenosis (AS), MAP is not reflective of mean systolic left ventricular (LV) pressure due to the transvalvular gradient. Non-invasive assessment of mean systolic LV pressure is challenging in severe aortic stenosis. CPI assessed using systemic MAP was previously shown to predict survival post transcatheter aortic valve replacement (TAVR). Purpose We evaluated the utility of a gradient adjusted CPI in predicting survival post TAVR compared to CPI alone Methods A retrospective study was performed including patients undergoing TAVR with 1 year follow-up. Baseline demographics, clinical, and echocardiographic data were abstracted from a cohort of 1,011 patients. CPI was calculated, (CO x MAP)/ (451 x BSA) Watts/m2. Gradient adjusted CPI was calculated using an augmented MAP i) adding aortic valve mean gradient(AVMG) to systolic blood pressure (CPI1); ii) adding aortic valve maximal instantaneous gradient to systolic blood pressure (CPI2) and iii) adding AVMG to MAP (CPI3). Patient survival score was calculated using a step up technique to identify the cut off value for CPI and gradient adjusted CPI to identify, where the maximum difference in mortality occurred. Multivariate cox-regression analysis was performed to adjust for baseline covariates. Receiver operator curves(ROC) for CPI and gradient adjusted CPI were calculated to predict survival post TAVR. Results The mortality rate at 1 yr was 16%. Mean age and AVMG of survivors was 81 +/- 9 yrs and 43 +/-14 mmHg vs 80 +/-9 yrs and 42 +/- 13 mmHg in the deceased group. Proportion of female patients was similar in both groups (p = 0.7). Patients in the deceased group at baseline had a higher prevalence of chronic lung disease, atrial fibrillation, heart failure within 2-weeks of procedure, higher STS-PROM score, lower serum albumin level, higher prevalence of moderate to severe tricuspid regurgitation, higher right ventricular systolic pressure and higher prevalence of dialysis. Both CPI and gradient adjusted CPI were independently associated with survival at 1 year. The area under ROC for CP, CP1, CP2 and CP3 were 0.67 (95% confidence interval [CI] 0.62 - 0.72), 0.65 (95% CI 0.60 – 0.70), 0.66 (95% CI 0.61 – 0.71) and 0.63 (95% CI 0.58 – 0.68) respectively. Conclusion Gradient adjusted CPI did not improve accuracy of predicting post TAVR survival at 1 year compared to CPI alone. Abstract P339 Figure. Area under ROC
P1798 Determinants of increased mitral mean diastolic gradient after transcatheter edge-to-edge mitral valve repair
Oğuz, Didem , Padang, Ratnasari , Pislaru, S V, Nkomo, V T, Mankad, Sunil , Malouf, Joseph F., Guerrero, M, Reeder, Guy S., Eleid, Mackram F. , Rihal, Charanjit S. , Thaden, Jeremy J. , Rihal, Charanjit S.

Mayo Clinic

European Heart Journal - Cardiovascular Imaging | January 17, 2020 | Volume: 21 | Issue: Supplement_1 | Pages: No page available

10.1093/ehjci/jez319.1153 Get It

Abstract Background Transcatheter edge-to-edge mitral valve repair (TMVR; MitraClip, Abbott Vascular) is clinically approved for treatment of severe, symptomatic mitral regurgitation (MR) in high or prohibitive surgical risk patients. Iatrogenic mitral stenosis is a known complication of TMVR, but determinants of increased post-procedure mean diastolic gradient are not well defined. Purpose We aimed to investigate the determinants of increased mitral mean diastolic gradient after TMVR. Methods We retrospectively reviewed 59 patients. 2D and 3D TEE data sets acquired before and immediately after procedure were analyzed. 4D Cardio-View and 4D MV-Assessment (TomTec, Germany) were used for the analysis of the 3D volume data set. Quantitative mitral valve analysis was done at the end of systole. Increased mitral mean diastolic gradient after TMVR was correlated with pre-procedure 2D and 3D echocardiographic data. Results 34 patients had primary MR, 25 patients had mixed/secondary MR. Baseline mean mitral diastolic gradient was 2.0 ± 0.9mmHg and increased to 3.9 ± 1.8mmHg post-TMVR and the mean 3D planimetric mitral valve area decreased from 5.3 ± 1.5cm2 to 2.6 ± 1.0cm2. Implantation of multiple clips was performed less frequently in patients with smaller baseline mitral valve area; 8% vs 47% in the lowest quartile vs all others (p = 0.006). 12(20%) of patients had a mean diastolic gradient &gt;5mmHg post-TMVR and 15(25%) of patients had a post-TMVR mitral valve area &lt;2.0 cm2. There was no significant difference in post-procedure heart rate between patients with mean diastolic gradient ≤5mmHg vs &gt;5mmHg (p = 0.08). Patient characteristics according to post-TMVR mean diastolic gradient are shown in the Table. Post-TMVR mean diastolic gradient &gt;5mmHg was more common in patients with increased pre-procedure mean diastolic gradient(p = 0.006), post-TMVR mitral valve area &lt;2.0 cm2(40% vs 14%, p = 0.03), and ≥moderate residual mitral regurgitation(38% vs 11%, p = 0.02). Post-TMVR mitral valve area &lt;2.0cm2 was present in 50% vs 19% of patients with vs without a mean gradient &gt;5mmHg(p = 0.04). Conclusions Elevated post-TMVR mean diastolic gradient is multifactorial and related to mitral stenosis, but residual mitral regurgitation also appears to be an important contributor to increased gradients in some patients. Larger cohorts are likely needed to assess the concurrent impact of mitral annular calcification, leaflet calcification, and other variables on post-TMVR mean gradient. Abstract P1798 Figure. 2D and 3D Echocardiographic Parameters
Transcatheter closure of coronary artery fistula: A 21‐year experience
El‐Sabawi, Bassim , Al‐Hijji, Mohammed , Eleid, Mackram F. , Cabalka, Allison K. , Ammash, Naser M., Dearani, Joseph A. , Bjarnason, Haraldur , Holmes, David R. , Rihal, Charanjit S. , Al-Hijji, Mohammed A , Cabalka, Allison , Bjarnason, Haraldur , Dearani, Joseph A. , Rihal, Charanjit S.

Mayo Clinic

Catheterization and Cardiovascular Interventions | January 10, 2020 | Volume: 96 | Issue: 2 | Pages: 311-319

10.1002/ccd.28721 | PMID 31922335 Get It

AbstractObjectivesTo evaluate the outcomes of transcatheter coronary artery fistula (CAF) closure and to identify anatomic/procedural factors that may impact outcomes.BackgroundDue to the rarity of CAF, reported experience with transcatheter closure remains limited and anatomic and procedural factors that may lead to unsuccessful closure, complications, or recanalization of CAF are unclear.MethodsAll patients who underwent transcatheter CAF closure at Mayo Clinic from 1997 to 2018 were retrospectively reviewed. CAF anatomic characteristics, procedural techniques, and clinical/angiographic outcomes were assessed.ResultsA total of 45 patients underwent transcatheter closure of 56 CAFs. The most commonly used devices were embolization coils in 40 (71.4%) CAFs, vascular occluders in 10 (17.8%), or covered stent in 2 (3.6%). Acute procedural success with no or trivial residual flow occurred in 50 (89.3%) CAFs. Residual flow was small in three (5.4%) and large in three (5.4%). Eight (17.8%) patients had complications, including device migration in three, intracranial hemorrhage from anticoagulation in one, and myocardial infarction (MI) in four. MI was a result of covered stent thrombosis or stagnation of flow after closure of large distal CAF. Twenty‐two patients with 27 CAFs had follow‐up angiography after successful index procedure at median time of 423 (IQ 97‐1348) days. Of these, 23 (85.2%) had no/trace flow and 4 had large flow from recanalization.ConclusionsTranscatheter CAF closure is associated with a favorable acute procedural success and complication rate in selected patients. Procedural success and risk for complication are highly dependent on CAF anatomy and closure technique.
Aortic stenosis and the pulse contour: A true marker of severity?
Eleid, Mackram F. , Nishimura, Rick A.

Mayo Clinic

Catheterization and Cardiovascular Interventions | December 23, 2019 | Volume: 95 | Issue: 6 | Pages: 1235-1239

10.1002/ccd.28674 | PMID 31868287 Get It

AbstractThe aortic pulse contour displays characteristic changes associated with the progression of aortic stenosis (AS). A diminished and delayed aortic pulse contour is indicative of significant AS, but the aortic contour may also be affected by factors including aging, hypertension and increased peripheral arterial elastance. This review describes the components of the aortic pulse contour in AS and how it can be affected by different conditions and interventions.
Extracorporeal Membrane Oxygenation Use in Acute Myocardial Infarction in the United States, 2000 to 2014
Vallabhajosyula, Saraschandra , Prasad, Abhiram , Bell, Malcolm R. , Sandhu, Gurpreet S. , Eleid, Mackram F. , Schears, Gregory J. , Stulak, John M., Jaffe, Allan S. , Holmes, David R. , Rihal, Charanjit S. , Barsness, Gregory W. , Dunlay, Shannon M. , Vallabhajosyula, Saraschandra , Prasad, Abhiram , Singh, Mandeep , Gersh, Bernard J. , Jaffe, Allan S. , Rihal, Charanjit S.

Mayo Clinic

Circulation: Heart Failure | December 12, 2019 | Volume: 12 | Issue: 12 | Pages: No page available

10.1161/circheartfailure.119.005929 | PMID 31826642 Get It

Background: Extracorporeal membrane oxygenation (ECMO) is increasingly used in acute myocardial infarction (AMI); however, there are limited large-scale national data. Methods: Using the National Inpatient Sample database from 2000 to 2014, a retrospective cohort of AMI utilizing ECMO was identified. Use of percutaneous coronary intervention, intra-aortic balloon pump, and percutaneous left ventricular assist device (LVAD) was also identified in this population. Outcomes of interest included temporal trends in utilization of ECMO alone and with concomitant procedures (percutaneous coronary intervention, intra-aortic balloon pump, and percutaneous LVAD), in-hospital mortality, and resource utilization. Results: In ≈9 million AMI admissions, ECMO was used in 2962 (<0.01%) and implanted a median of 1 day after admission. ECMO was used in 0.5% and 0.3% AMI admissions complicated by cardiogenic shock and cardiac arrest, respectively. ECMO was used more commonly in admissions that were younger, nonwhite, and with less comorbidity. ECMO use was 11× higher in 2014 as compared with 2000 (odds ratio, 11.37 [95% CI, 7.20–17.97]). Same-day percutaneous coronary intervention was performed in 23.1%; intra-aortic balloon pump/percutaneous LVAD was used in 57.9%, of which 30.3% were placed concomitantly. In-hospital mortality with ECMO was 59.2% overall but decreased from 100% (2000) to 45.1% (2014). Durable LVAD and cardiac transplantation were performed in 11.7% as an exit strategy. Of the hospital survivors, 40.8% were discharged to skilled nursing facilities. Older age, male sex, nonwhite race, and lower socioeconomic status were independently associated with higher in-hospital mortality with ECMO use. Conclusions: In AMI admissions, a steady increase was noted in the utilization of ECMO alone and with concomitant procedures (percutaneous coronary intervention, intra-aortic balloon pump, and percutaneous LVAD). In-hospital mortality remained high in AMI admissions treated with ECMO.