Citations

Clear

151 citation(s) found for "DeSimone, Christopher V".

The essential skill of ECG interpretation: How do we define and improve competency?
Kashou, Anthony H. , May, Adam M. , DeSimone, Christopher P., Kashou, Anthony , May, Adam, May, Adam M , DeSimone, Christopher, Noseworthy, Peter A.

Mayo Clinic

Postgraduate Medical Journal | December 24, 2019 | Volume: 96 | Issue: 1133 | Pages: 125-127

10.1136/postgradmedj-2019-137191 | PMID 31874907 Get It

The VT Prediction Model: A simplified means to differentiate wide complex tachycardias
May, Adam M. , Kashou, Anthony H. , Sridhar, Haarini , Hodge, David O. , Carter, Rickey E. , Lin, Grace , Asirvatham, Samuel J. , Noseworthy, Peter A. , Deshmukh, Abhishek , Carter, Rickey, Asirvatham, Samuel J , Noseworthy, Peter A , Deshmukh, Abhishek J , Carter, Rickey E , May, Adam M , DeSimone, Christopher V.

Mayo Clinic

Journal of Cardiovascular Electrophysiology | December 16, 2019 | Volume: 31 | Issue: 1 | Pages: 185-195

10.1111/jce.14321 | PMID 31840870 Get It

AbstractBackgroundThe accurate separation of undifferentiated wide complex tachycardias (WCTs) into ventricular tachycardia (VT) or supraventricular wide complex tachycardia (SWCT) using conventional, manually‐applied 12‐lead electrocardiogram (ECG) interpretation methods is difficult.PurposeWe sought to devise a new WCT differentiation method that operates solely on automated measurements routinely provided by computerized ECG interpretation software.MethodsIn a two‐part analysis, we developed and validated a logistic regression model (ie, VT Prediction Model) that utilizes routinely available computerized measurements derived from patients' paired WCT and baseline ECGs.ResultsThe derivation cohort consisted of 601 paired WCT (273 VT, 328 SWCT) and baseline ECGs from 421 patients. The VT Prediction Model, composed of WCT QRS duration (ms) (P < .0001), QRS duration change (ms) (P < .0001), QRS axis change (°) (P < .0001) and T axis change (°) (P < .0001), yielded effective VT and SWCT differentiation (area under the curve [AUC]: 0.924; confidence interval [CI]: 0.903‐0.944) for the derivation cohort. The validation cohort comprised 241 paired WCT (97 VT, 144 SWCT) and baseline ECGs from 177 patients. The VT Prediction Model's implementation on the validation cohort yielded effective WCT differentiation (AUC: 0.900; CI: 0.862‐0.939) with overall accuracy, sensitivity, and specificity of 85.0%, 80.4%, and 88.2%, respectively.ConclusionThe VT Prediction Model is an example of how readily available ECG measurements may be used to distinguish VT and SWCT effectively. Further study is needed to develop and refine newer WCT differentiation approaches that utilize computerized measurements provided by ECG interpretation software.
Contemporary Management of Antiplatelet and Anticoagulation for Cardiac Implantable Device Procedures
Cha, Yong‐Mei , DeSimone, Christopher V. , DeSimone, Daniel C.

Mayo Clinic

Circulation: Arrhythmia and Electrophysiology | October 15, 2019 | Volume: 12 | Issue: 10 | Pages: No page available

10.1161/circep.119.007863 | PMID 31610719 Get It

Influence of Acetylsalicylic Acid Use on Risk and Outcome of Community-Acquired Staphylococcus aureus Bacteremia: A Population-Based Study
Smit, Jesper, Dalager‐Pedersen, Michael , Kaasch, Achim J. , Thomsen, Reimar W. , Frøslev, Trine , Nielsen, Henrik , Schønheyder, Henrik Carl , Sørensen, Henrik Toft , Søgaard, Mette , Adelborg, Kasper , DeSimone, Christopher V. , DeSimone, Daniel C.

Mayo Clinic

Open Forum Infectious Diseases | September 20, 2019 | Volume: 6 | Issue: 9 | Pages: No page available

10.1093/ofid/ofz356 | PMID 31660413 Get It

Abstract Objective To investigate the influence of acetylsalicylic acid (ASA) use on risk and outcome of community-acquired Staphylococcus aureus bacteremia (CA-SAB). Method We used population-based medical databases to identify all patients diagnosed in northern Denmark with first-time CA-SAB and matched population controls from 2000–2011. Categories for ASA users included current users (new or long-term users), former users, and nonusers. The analyses were adjusted for comorbidities, comedication use, and socioeconomic indicators. Results We identified 2638 patients with first-time CA-SAB and 26 379 matched population controls. Compared with nonusers, the adjusted odds ratio (aOR) for CA-SAB was 1.00 (95% confidence interval [CI], 0.88–1.13) for current users, 1.00 (95% CI, 0.86–1.16) for former users, 2.04 (95% CI, 1.42–2.94) for new users, and 0.95 (95% CI, 0.84–1.09) for long-term users. Thirty-day cumulative mortality was 28.0% among current users compared with 21.6% among nonusers, yielding an adjusted hazard rate ratio (aHRR) of 1.02 (95% CI, 0.84–1.25). Compared with nonusers, the aHRR was 1.10 (95% CI, 0.87–1.40) for former users, 0.60 (95% CI, 0.29–1.21) for new users, and 1.06 (95% CI, 0.87–1.31) for long-term users. We observed no difference in the risk or outcome of CA-SAB with increasing ASA dose or by presence of diseases commonly treated with ASA. Conclusions Use of ASA did not seem to influence the risk or outcome of CA-SAB. The apparent increased risk among new users may relate to residual confounding from the circumstances underlying ASA treatment initiation. Our finding of no association remained robust with increasing ASA dose and across multiple patient subsets.
Purkinje tissue modification and ventricular fibrillation
Asirvatham, Samuel J. , Asirvatham, Samuel J , DeSimone, Christopher V.

Mayo Clinic

Pacing and Clinical Electrophysiology | August 13, 2019 | Volume: 42 | Issue: 10 | Pages: 1291-1293

10.1111/pace.13781 | PMID 31407803 Get It

Augmented intelligence improves stroke risk prediction in atrial fibrillation
Deshmukh, Abhishek , Deshmukh, Abhishek J , DeSimone, Christopher V.

Mayo Clinic

Journal of Cardiovascular Electrophysiology | May 22, 2019 | Volume: 30 | Issue: 9 | Pages: 1462-1463

10.1111/jce.13997 | PMID 31115948 Get It

Comparing the incidence of ventricular arrhythmias during epicardial ablation in swine versus canine models
Caluori, Guido , Wojtaszczyk, Adam , Yasin, Omar , Pešl, Martin , Wolf, Jiří , Bělašková, Silvie , Crha, Michal, Sugrue, Alan , Vaidya, Vaibhav R. , Naksuk, Niyada , Killu, Ammar M. , Padmanabhan, Deepak , Asirvatham, Samuel J. , Stárek, Zdeněk , DeSimone, Christopher V , Killu, Ammar M , Stárek, Zdeněk , Asirvatham, Samuel J , DeSimone, Christopher V.

Mayo Clinic

Pacing and Clinical Electrophysiology | April 16, 2019 | Volume: 42 | Issue: 7 | Pages: 862-867

10.1111/pace.13698 | PMID 30989679 Get It

Abstract Background Choosing the appropriate animal model for development of novel technologies requires an understanding of anatomy and physiology of these different models. There are little data about the characteristics of different animal models for the study of technologies used for epicardial ablation. We aimed to compare the incidence of ventricular arrhythmias during epicardial radiofrequency ablation between swine and canine models using novel epicardial ablation catheters. Methods We conducted a retrospective study using data obtained from epicardial ablation experiments performed on swine ( Sus Scrofa ) and canine ( Canis familiaris ) models. We compared the incidence of ventricular arrhythmias during ablation between swine and canine using multivariate regression analysis. Six swine and six canine animals underwent successful epicardial radiofrequency ablation. A total of 103 ablation applications were recorded. Results Ventricular arrhythmias requiring cardioversion occurred in 13.11% of radiofrequency ablation applications in swine and 9.75% in canine (relative risk: 117.6%, 95% confidence interval [CI]: 83.97‐164.69, animal‐based odds ratio [OR]: .55, 95% CI: .23‐61.33; P = .184). When adjusting for application position, duration of ablation and power, the odds of developing potentially lethal ventricular arrhythmia in swine increased significantly compared to canine (OR: 3.60, 95% CI: 1.35‐9.55; P = .010). Conclusions The swine myocardium is more susceptible to developing ventricular arrhythmias compared to canine model during epicardial ablation. This issue should be carefully considered in future studies.
Telocytes express ANO‐1‐encoded chloride channels in canine ventricular myocardium
Pinilla, Pedro J Gomez, Beyder, Arthur, Farrugia, Gianrico , Asirvatham, Samuel J. , Gomez Pinilla, Pedro J, Kapa, Suraj , Asirvatham, Samuel J , DeSimone, Christopher V. , McLeod, Christopher J. , Kapa, Suraj

Mayo Clinic

Journal of Arrhythmia | April 6, 2019 | Volume: 35 | Issue: 3 | Pages: 515-521

10.1002/joa3.12176 | PMID 31293701 Get It

AbstractIntroductionIt is unknown if ANO‐1 is expressed in the heart, though the presence of a calcium‐activated chloride current has been proposed to mediate some cardiac dysrhythmias. Furthermore, a specific cell type termed telocytes, morphologically mimicking Cajal cells which use ANO‐1 to modulate their pacemaker activity in the gut, have been described in the heart. We therefore sought to determine whether this channel is expressed in the canine heart.MethodsMyocardium was sampled from the ventricles of five canines. Sections were labeled with anti‐Kit and anti‐ANO‐1 antibodies. Slides were reviewed by four investigators looking at cell morphology, distribution, and co‐localization. Identification of telocytes was based on criteria including morphology, Kit positivity (+), and ANO‐1 positivity (+).ResultsClusters of cells meeting criteria for telocytes were seen in the epicardium, sub‐epicardium, and mid‐myocardium. A small subset of cells that were morphologically similar to myocytes was ANO‐1 (+) but Kit (−). In total, three different cell classes were found: (i) Kit (+), ANO‐1 (+) cells with the appearance of telocytes; (ii) Kit (+), ANO‐1 (−) cells; and (iii) Kit (−), ANO‐1 (+) cells with the morphologic appearance of cardiac myocytes.ConclusionsTelocytes are present in the canine ventricle and express ANO‐1. These data merit further study to elucidate the functional expression of these channels in the heart and whether they may be targets for cardiac arrhythmias.
P5792Risks factors for dofetilide-associated torsades de pointes among hospitalized patients with atrial fibrillation
Naksuk, Niyada , Witt, Christoffer Tobias , Sugrue, Alan , DeSimone, Christopher V. , Witt, C, Kella, Danesh , Noseworthy, Peter A.

Mayo Clinic

European Heart Journal | December 10, 2018 | Volume: 39 | Issue: suppl_1 | Pages: No page available

10.1093/eurheartj/ehy566.p5792 Get It

Elimination of Purkinje Fibers by Electroporation Reduces Ventricular Fibrillation Vulnerability
Livia, Christopher , Sugrue, Alan , Witt, Tyra A. , Polkinghorne, Murray , Maor, Elad , Behfar, Atta , Asirvatham, Samuel J. , Witt, Tyra, Polkinghorne, Murray D, Kapa, Suraj , Lehmann, Helge I, Behfar, Atta , Asirvatham, Samuel J , Livia, Christopher , Maor, Elad , Lehmann, H. Immo , DeSimone, Christopher V. , McLeod, Christopher J.

Mayo Clinic

Journal of the American Heart Association | September 16, 2018 | Volume: 7 | Issue: 15 | Pages: No page available

10.1161/jaha.118.009070 | PMID 30371233 Get It

Background The Purkinje network appears to play a pivotal role in the triggering as well as maintenance of ventricular fibrillation. Irreversible electroporation ( IRE ) using direct current has shown promise as a nonthermal ablation modality in the heart, but its ability to target and ablate the Purkinje tissue is undefined. Our aim was to investigate the potential for selective ablation of Purkinje/fascicular fibers using IRE . Methods and Results In an ex vivo Langendorff model of canine heart (n=8), direct current was delivered in a unipolar manner at various dosages from 750 to 2500 V, in 10 pulses with a 90‐μs duration at a frequency of 1 Hz. The window of ventricular fibrillation vulnerability was assessed before and after delivery of electroporation energy using a shock on T‐wave method. IRE consistently eradicated all Purkinje potentials at voltages between 750 and 2500 V (minimum field strength of 250–833 V/cm). The ventricular electrogram amplitude was only minimally reduced by ablation: 0.6±2.3 mV ( P =0.03). In 4 hearts after IRE delivery, ventricular fibrillation could not be reinduced. At baseline, the lower limit of vulnerability to ventricular fibrillation was 1.8±0.4 J, and the upper limit of vulnerability was 19.5±3.0 J. The window of vulnerability was 17.8±2.9 J. Delivery of electroporation energy significantly reduced the window of vulnerability to 5.7±2.9 J ( P =0.0003), with a postablation lower limit of vulnerability=7.3±2.63 J, and the upper limit of vulnerability=18.8±5.2 J. Conclusions Our study highlights that Purkinje tissue can be ablated with IRE without any evidence of underlying myocardial damage.