Citations

Clear

149 citation(s) found for "Freeman, William D".

Letter by Freeman and Freeman Regarding Article, “Sex Differences in Faculty Rank Among Academic Cardiologists in the United States”
Freeman, Michelle L., Freeman, William D. , Freeman, William D

Mayo Clinic

Circulation | June 19, 2017 | Volume: 135 | Issue: 25 | Pages: No page available

10.1161/circulationaha.117.027766 | PMID 28630276 Get It

Guidelines for Family-Centered Care in Neuro-ICU Populations: Caveats for Routine Palliative Care
Torbey, Michel , Brophy, Gretchen M. , Varelas, Panayiotis N. , Bösel, Julian , Manno, Edward M., Suárez, José I. , Seder, David B. , Freeman, William D. , Torbey, Michel T, Bader, Mary Kay , Freeman, William D , Brophy, Gretchen M

Mayo Clinic

Critical Care Medicine | May 17, 2017 | Volume: 45 | Issue: 6 | Pages: e620-e621

10.1097/ccm.0000000000002344 | PMID 28509746 Get It

Stroke Diagnosis and Treatment in the Emergency Department
Siegel, Jason , Pizzi, Michael , Freeman, William D. , Siegel, Jason L, Pizzi, Michael A. , Freeman, William David, Freeman, William D

Mayo Clinic

JAMA Neurology | January 23, 2017 | Volume: 74 | Issue: 3 | Pages: 362

10.1001/jamaneurol.2016.5561 | PMID 28114682 Get It

Expertise Matters
Manno, Edward M., Freeman, William D. , Livesay, Sarah , Geocadin, Romergryko G. , Torbey, Michel , Hemphill, Claude, Nyquist, Paul , Freeman, William D

Mayo Clinic

Critical Care Medicine | October 15, 2016 | Volume: 44 | Issue: 11 | Pages: e1147-e1148

10.1097/ccm.0000000000001993 | PMID 27755089 Get It

Technical feasibility and safety of an intraoperative head‐up display device during spine instrumentation
Chen, Robert E., Han, Phillip K., Si, Phong, Freeman, William D. , Pirris, Stephen M. , Yoon, Jang W. , Freeman, William D

Mayo Clinic

The International Journal of Medical Robotics and Computer Assisted Surgery | August 29, 2016 | Volume: 13 | Issue: 3 | Pages: No page available

10.1002/rcs.1770 | PMID 27569781 Get It

AbstractBackgroundThe primary aim of this study was to determine the safety and feasibility of capturing and streaming neuronavigation images onto a head‐up display during spine instrumentation.MethodsUsing a novel device, neuronavigation images were captured and transferred wirelessly via a password‐encrypted network to the head‐up display. At the end of the procedure, the surgeons completed a survey to gather their opinions of the system.ResultsForty pedicle screws were placed using the head‐up display. The average screw placement time was slightly shorter when the head‐up display was used (4.13 min with vs. 4.86 min without). The post‐procedure survey demonstrated that 79% of surgeon's responses were positive.ConclusionA wearable head‐up display can benefit current neuronavigation systems, but larger, outcomes‐based trials are needed. Higher processing speed would allow streaming of higher resolution images. Along with an enlarged display, these may significantly improve utilization of this technology. Copyright © 2016 John Wiley & Sons, Ltd.
Proton Pump Inhibitors and Dementia Incidence
Freeman, William D. , Freeman, William D

Mayo Clinic

JAMA Neurology | June 20, 2016 | Volume: 73 | Issue: 8 | Pages: 1026

10.1001/jamaneurol.2016.1503 | PMID 27322437 Get It

Precision medicine of aneurysmal subarachnoid hemorrhage, vasospasm and delayed cerebral ischemia
Burrell, Christian , Avalon, Nicole E. , Siegel, Jason , Pizzi, Michael , Dutta, Tumpa , Charlesworth, M. Cristine , Freeman, William D. , Charlesworth, M. Cristine , Freeman, William D

Mayo Clinic

Expert Review of Neurotherapeutics | June 17, 2016 | Volume: 16 | Issue: 11 | Pages: 1251-1262

10.1080/14737175.2016.1203257 | PMID 27314601 Get It

Ambulance-based assessment of NIH Stroke Scale with telemedicine: A feasibility pilot study
Barrett, Kevin M. , Pizzi, Michael , Kesari, Vivek , TerKonda, Sarvam P. , Mauricio, Elizabeth A. , Silvers, Scott M., Habash, Ranya, Brown, Benjamin L. , Wharen, Robert E. , Freeman, William D. , Pizzi, Michael A. , Wharen, Robert, Mauricio, Elizabeth A. , Tawk, Rabih G. , Meschia, James F. , Freeman, William D

Mayo Clinic

Journal of Telemedicine and Telecare | May 13, 2016 | Volume: 23 | Issue: 4 | Pages: 476-483

10.1177/1357633x16648490 | PMID 27177870 Get It

Background Ischemic stroke is a time-sensitive disease, with improved outcomes associated with decreased time from onset to treatment. It was hypothesised that ambulance-based assessment of the National Institutes of Health Stroke Scale (NIHSS) using a Health Insurance Portability and Accountability Act (HIPAA)–compliant mobile platform immediately prior to arrival is feasible. Methods This is a proof-of-concept feasibility pilot study in two phases. The first phase consisted of an ambulance-equipped HIPAA-compliant video platform for remote NIHSS assessment of a simulated stroke patient. The second phase consisted of remote NIHSS assessment by a hospital-based neurologist of acute stroke patients en route to our facility. Five ambulances were equipped with a 4G/LTE-enabled tablet preloaded with a secure HIPAA-compliant telemedicine application. Secondary outcomes assessed satisfaction of staff with the remote platform. Results Phase one was successful in the assessment of three out of three simulated patients. Phase two was successful in the assessment of 10 out of 11 (91%) cases. One video attempt was unsuccessful because local LTE was turned off on the device. The video signal was dropped transiently due to weather, which delayed NIHSS assessment in one case. Average NIHSS assessment time was 7.6 minutes (range 3–9.8 minutes). Neurologists rated 83% of encounters as ‘satisfied’ to ‘very satisfied’, and the emergency medical service (EMS) rated 90% of encounters as ‘satisfied’ to ‘very satisfied’. The one failed video attempt was associated with ‘poor’ EMS satisfaction. Conclusion This proof-of-concept pilot demonstrates that remote ambulance-based NIHSS assessment is feasible. This model could reduce door-to-needle times by conducting prehospital data collection.
Early Absent Pupillary Light Reflexes After Cardiac Arrest in Patients Treated with Therapeutic Hypothermia
Dhakal, Laxmi, Sen, Ayan , Stanko, Carlene, Rawal, Bhupendra, Hoyne, Jonathan , Dimberg, Elliot L., Freeman, Michelle L., Freeman, William D. , Dhakal, Laxmi P, Stanko, Carlene M, Hoyne, Jonathan B, Ng, Lauren K, Heckman, Michael G. , Ng, Lauren , Rabinstein, Alejandro A. , Freeman, William D

Mayo Clinic

Therapeutic Hypothermia and Temperature Management | May 2, 2016 | Volume: 6 | Issue: 3 | Pages: 116-121

10.1089/ther.2015.0035 | PMID 27135180 Get It

Letter to the Editor: Dural arteriovenous fistula mimicking Creutzfeldt-Jakob disease
Freeman, William D. , Sebesto, Jason, Sebesto, Jason R., Tawk, Rabih G. , Freeman, William D

Mayo Clinic

Journal of Neurosurgery | April 22, 2016 | Volume: 125 | Issue: 1 | Pages: 231-232

10.3171/2015.12.jns152840 | PMID 27104843 Get It