Citations 10

Variability of Brain Death Policies in the United States (P3.225)

Neurology | December 7, 2023 | Volume: 86 | Issue: 16_supplement | Pages: No page available

10.1212/wnl.86.16_supplement.p3.225

Comparison of 1 vs 2 Brain Death Examinations on Time to Death Pronouncement and Organ Donation

Neurology | March 8, 2021 | Volume: 96 | Issue: 10 | Pages: No page available

10.1212/wnl.0000000000011554 | PMID 33514644

Brain Death in Patients With “Isolated” Brainstem Lesions: A Case Against Controversy

Journal of Neurosurgical Anesthesiology | December 11, 2018 | Volume: 31 | Issue: 2 | Pages: 171-173

10.1097/ana.0000000000000568 | PMID 30540618

Guidelines for Family-Centered Care in Neuro-ICU Populations: Caveats for Routine Palliative Care

Critical Care Medicine | May 17, 2017 | Volume: 45 | Issue: 6 | Pages: e620-e621

10.1097/ccm.0000000000002344 | PMID 28509746

Improving uniformity in brain death determination policies over time

Neurology | January 12, 2017 | Volume: 88 | Issue: 6 | Pages: 562-568

10.1212/wnl.0000000000003597 | PMID 28077490

American Academy of Neurology Guidelines and the Neurologic Determination of Death—Reply

JAMA Neurology | April 11, 2016 | Volume: 73 | Issue: 6 | Pages: 761

10.1001/jamaneurol.2016.0431 | PMID 27065178

Variability of Brain Death Policies in the United States

JAMA Neurology | December 31, 2015 | Volume: 73 | Issue: 2 | Pages: 213

10.1001/jamaneurol.2015.3943 | PMID 26719912

Accuracy of the ABC/2 Score for Intracerebral Hemorrhage

Stroke | August 5, 2015 | Volume: 46 | Issue: 9 | Pages: 2470-2476

10.1161/strokeaha.114.007343 | PMID 26243227

Background and Purpose— The ABC/2 score estimates intracerebral hemorrhage (ICH) volume, yet validations have been limited by small samples and inappropriate outcome measures. We determined accuracy of the ABC/2 score calculated at a specialized reading center (RC-ABC) or local site (site-ABC) versus the reference-standard computed tomography–based planimetry (CTP). Methods— In Minimally Invasive Surgery Plus Recombinant Tissue-Type Plasminogen Activator for Intracerebral Hemorrhage Evacuation-II (MISTIE-II), Clot Lysis Evaluation of Accelerated Resolution of Intraventricular Hemorrhage (CLEAR-IVH) and CLEAR-III trials. ICH volume was prospectively calculated by CTP, RC-ABC, and site-ABC. Agreement between CTP and ABC/2 was defined as an absolute difference up to 5 mL and relative difference within 20%. Determinants of ABC/2 accuracy were assessed by logistic regression. Results— In 4369 scans from 507 patients, CTP was more strongly correlated with RC-ABC ( r 2 =0.93) than with site-ABC ( r 2 =0.87). Although RC-ABC overestimated CTP-based volume on average (RC-ABC, 15.2 cm 3 ; CTP, 12.7 cm3), agreement was reasonable when categorized into mild, moderate, and severe ICH (κ=0.75; P <0.001). This was consistent with overestimation of ICH volume in 6 of 8 previous studies. Agreement with CTP was greater for RC-ABC (84% within 5 mL; 48% of scans within 20%) than for site-ABC (81% within 5 mL; 41% within 20%). RC-ABC had moderate accuracy for detecting ≥5 mL change in CTP volume between consecutive scans (sensitivity, 0.76; specificity, 0.86) and was more accurate with smaller ICH, thalamic hemorrhage, and homogeneous clots. Conclusions— ABC/2 scores at local or central sites are sufficiently accurate to categorize ICH volume and assess eligibility for the CLEAR-III and MISTIE III studies and moderately accurate for change in ICH volume. However, accuracy decreases with large, irregular, or lobar clots. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: MISTIE-II NCT00224770; CLEAR-III NCT00784134.
Evidence-based guideline update: Determining brain death in adults

Neurology | June 7, 2010 | Volume: 74 | Issue: 23 | Pages: 1911-1918

10.1212/wnl.0b013e3181e242a8 | PMID 20530327

Variability of brain death determination guidelines in leading US neurologic institutions

Neurology | December 13, 2007 | Volume: 70 | Issue: 4 | Pages: 284-289

10.1212/01.wnl.0000296278.59487.c2 | PMID 18077794