Prospective Pilot Evaluation of Radiologists and Computer-aided Pulmonary Nodule Detection on Ultra–low-Dose CT With Tin Filtration
Takahashi, Edwin A. , Koo, Chi Wan , White, Darin , Lindell, Rebecca M. , Sykes, Anne-Marie G., Levin, David L. , Bogoni, Luca, Carter, Rickey E. , Carter, Rickey E , Takahashi, Edwin A , Kuzo, Ronald S. , Wolf, Matthias , McCollough, Cynthia H. , Fletcher, Joel G.

Mayo Clinic

Journal of Thoracic Imaging | July 26, 2018 | Volume: 33 | Issue: 6 | Pages: 396-401

10.1097/rti.0000000000000348 | PMID 30048344 Get It

Purpose: The aim of this study was to evaluate the ability of computer-aided detection (CAD) and human readers to detect pulmonary nodules ≥5 mm using 100 kV ultra–low-dose computed tomography (ULDCT) utilizing a tin filter. Materials and Methods: After informed consent, 55 patients prospectively underwent standard-dose chest CT (SDCT) using 120 kV followed by ULDCT using 100 kV/tin. Reference nodules ≥5 mm were identified by a thoracic radiologist using SDCT. Four thoracic radiologists marked detected nodules on SDCT and ULDCT examinations using a dedicated computer workstation. After a 6-month memory extinction, readers were shown the same ULDCT cases with all CAD markings as well as their original detections, and characterized CAD detections as true positive or false positive. Results: Volume CT Dose index (CTDIvol) for SDCT and ULDCT were 5.3±2 and 0.4±0.2 mGy (P<0.0001), respectively. Forty-five reference nodules were detected in 30 patients. Reader sensitivity varied widely but similarly for SDCT (ranging from 45% to 87%) and ULDCT (45% to 83%). CAD sensitivity was 76% (34/45) for SDCT and 71% (32/45) for ULDCT. After CAD, reader sensitivity substantially improved by 19% and 18% for 2 readers, and remained nearly unchanged for the other 2 readers (0% and 2%), despite reader perception that many more nodules were identified with CAD. There was a mean of 2 false-positive CAD detections/case. Conclusions: ULDCT with 100 kV/tin reduced patient dose by over 90% without compromising pulmonary nodule detection sensitivity. CAD can substantially improve nodule detection sensitivity at ULDCT for some readers, maintaining interobserver performance.
Novel Imaging Approaches in Inflammatory Bowel Diseases
Deepak, Parakkal , Bruining, David H. , Deepak, Parakkal , Fowler, Kathryn J. , Fletcher, Joel G.

Mayo Clinic

Inflammatory Bowel Diseases | July 13, 2018 | Volume: 25 | Issue: 2 | Pages: 248-260

10.1093/ibd/izy239 | PMID 30010908 Get It

CT for Evaluation of Acute Gastrointestinal Bleeding
Wells, Michael , Bruining, David H. , Fletcher, Joel G. , Froemming, Adam T. , Barlow, John M. , Fidler, Jeff L. , Wells, Michael L, Hansel, Stephanie L. , Fletcher, Joel G , Fidler, Jeff L.

Mayo Clinic

RadioGraphics | June 8, 2018 | Volume: 38 | Issue: 4 | Pages: 1089-1107

10.1148/rg.2018170138 | PMID 29883267 Get It

150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology
Rajendran, Kishore , Gong, Hao , Zhou, Wei , Halaweish, Ahmed F., Henning, André , Kappler, S. , Baer, Matthias , Rajendran, Kishore , Zhou, Wei , Leng, Shuai , Fletcher, Joel G. , McCollough, Cynthia H.

Mayo Clinic

Investigative Radiology | May 31, 2018 | Volume: 53 | Issue: 11 | Pages: 655-662

10.1097/rli.0000000000000488 | PMID 29847412 Get It

Objective The aims of this study were to quantitatively assess two new scan modes on a photon-counting detector computed tomography system, each designed to maximize spatial resolution, and to qualitatively demonstrate potential clinical impact using patient data. Materials and Methods This Health Insurance Portability Act–compliant study was approved by our institutional review board. Two high–spatial-resolution scan modes (Sharp and UHR) were evaluated using phantoms to quantify spatial resolution and image noise, and results were compared with the standard mode (Macro). Patients were scanned using a conventional energy-integrating detector scanner and the photon-counting detector scanner using the same radiation dose. In first patient images, anatomic details were qualitatively evaluated to demonstrate potential clinical impact. Results Sharp and UHR modes had a 69% and 87% improvement in in-plane spatial resolution, respectively, compared with Macro mode (10% modulation-translation-function values of 16.05, 17.69, and 9.48 lp/cm, respectively). The cutoff spatial frequency of the UHR mode (32.4 lp/cm) corresponded to a limiting spatial resolution of 150 μm. The full-width-at-half-maximum values of the section sensitivity profiles were 0.41, 0.44, and 0.67 mm for the thinnest image thickness for each mode (0.25, 0.25, and 0.5 mm, respectively). At the same in-plane spatial resolution, Sharp and UHR images had up to 15% lower noise than Macro images. Patient images acquired in Sharp mode demonstrated better delineation of fine anatomic structures compared with Macro mode images. Conclusions Phantom studies demonstrated superior resolution and noise properties for the Sharp and UHR modes relative to the standard Macro mode and patient images demonstrated the potential benefit of these scan modes for clinical practice.
J Pouch: Imaging Findings, Surgical Variations, Natural History, and Common Complications
Reber, Joshua D. , Barlow, John M. , Sheedy, Shannon P. , Bruining, David H. , Menias, Christine O. , Fletcher, Joel G. , Fletcher, Joel G , Lightner, Amy L.

Mayo Clinic

RadioGraphics | May 22, 2018 | Volume: 38 | Issue: 4 | Pages: 1073-1088

10.1148/rg.2018170113 | PMID 29787362 Get It

Evaluation of projection‐ and dual‐energy‐based methods for metal artifact reduction in CT using a phantom study
Long, Zaiyang , Bruesewitz, Michael R. , Amrami, Kimberly K. , Adkins, Mark C., Glazebrook, Katrina N. , Kofler, James M., Halaweish, Ahmed F., Yu, Lifeng , DeLone, David R. , Morris, Jonathan M. , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G. , Yu, Lifeng

Mayo Clinic

Journal of Applied Clinical Medical Physics | May 11, 2018 | Volume: 19 | Issue: 4 | Pages: 252-260

10.1002/acm2.12347 | PMID 29749048 Get It

AbstractObjectivesBoth projection and dual‐energy (DE)‐based methods have been used for metal artifact reduction (MAR) in CT. The two methods can also be combined. The purpose of this work was to evaluate these three MAR methods using phantom experiments for five types of metal implants.Materials and MethodsFive phantoms representing spine, dental, hip, shoulder, and knee were constructed with metal implants. These phantoms were scanned using both single‐energy (SE) and DE protocols with matched radiation output. The SE data were processed using a projection‐based MAR (iMAR, Siemens) algorithm, while the DE data were processed to generate virtual monochromatic images at high keV (Mono+, Siemens). In addition, the DE images after iMAR were used to generate Mono+ images (DE iMAR Mono+). Artifacts were quantitatively evaluated using CT numbers at different regions of interest. Iodine contrast‐to‐noise ratio (CNR) was evaluated in the spine phantom. Three musculoskeletal radiologists and two neuro‐radiologists independently ranked the artifact reduction.ResultsThe DE Mono+ at high keV resulted in reduced artifacts but also lower iodine CNR. The iMAR method alone caused missing tissue artifacts in dental phantom. DE iMAR Mono+ caused wrong CT numbers in close proximity to the metal prostheses in knee and hip phantoms. All musculoskeletal radiologists ranked SE iMAR > DE iMAR Mono+ > DE Mono+ for knee and hip, while DE iMAR Mono+ > SE iMAR > DE Mono+ for shoulder. Both neuro‐radiologists ranked DE iMAR Mono+ > DE Mono+ > SE iMAR for spine and DE Mono+ > DE iMAR Mono+ > SE iMAR for dental.ConclusionsThe SE iMAR was the best choice for the hip and knee prostheses, while DE Mono+ at high keV was best for dental implants and DE iMAR Mono+ was best for spine and shoulder prostheses. Artifacts were also introduced by MAR algorithms.
Predictors of Durability of Radiological Response in Patients With Small Bowel Crohn’s Disease
Deepak, Parakkal , Fidler, Jeff L. , Barlow, John M. , Sheedy, Shannon P. , Kolbe, Amy B. , Harmsen, William S. , Therneau, Terry M. , Becker, Brenda D., Loftus, Edward V. , Bruining, David H. , Loftus, Edward V , Deepak, Parakkal , Fletcher, Joel G. , Fidler, Jeff L. , Hansel, Stephanie L.

Mayo Clinic

Inflammatory Bowel Diseases | April 13, 2018 | Volume: 24 | Issue: 8 | Pages: 1815-1825

10.1093/ibd/izy074 | PMID 29668921 Get It

Normal values for assessment of anal sphincter morphology, anorectal motion, and pelvic organ prolapse with MRI in healthy women
Tirumanisetty, Pratyusha , Prichard, David O. , Zinsmeister, Alan R., Bharucha, Adil E. , Bharucha, A E , Fletcher, Joel G. , Chakraborty, Sumit

Mayo Clinic

Neurogastroenterology & Motility | March 2, 2018 | Volume: 30 | Issue: 7 | Pages: No page available

10.1111/nmo.13314 | PMID 29498141 Get It

AbstractBackgroundEndoanal MRI and MR defecography are used to identify anal sphincter injury and disordered defecation. However, few studies have evaluated findings in asymptomatic healthy people. The effects of BMI and parity on rectoanal motion and evacuation are unknown.MethodsIn 113 asymptomatic females (age 50 ± 17 years, Mean ± SD) without risk factors for anorectal trauma, anal sphincter appearance, anorectal motion, and pelvic organ prolapse were evaluated with MRI. The relationship between age, BMI, and parity and structural findings were evaluated with parametric and non‐parametric tests.ResultsThe anal sphincters and puborectalis appeared normal in over 90% of women. During dynamic MRI, the anorectal angle was 100 ± 1º (Mean ± SEM) at rest, 70 ± 2° at squeeze, and 120 ± 2° during defecation. The change in anorectal angle during squeeze (r = −.25, P < .005), but not during evacuation (r = .13, P = .25) was associated with age. In the multivariable models, BMI (P < .01) and parity (P < .01) were, respectively, independently associated with the intersubject variation in the anorectal angle at rest and the angle change during squeeze. Ten percent or fewer women had had descent of the bladder base or uterus 4 cm or more below the pubococcygeal line or a rectocele measuring 4 cm or larger. Only 5% had a patulous anal canal.ConclusionsIn addition to age, BMI and parity also affect anorectal motion in asymptomatic women. These findings provide age‐adjusted normal values for rectoanal anatomy and pelvic floor motion.
CT Dental Artifact: Comparison of an Iterative Metal Artifact Reduction Technique with Weighted Filtered Back-Projection
Diehn, Felix E. , Michalak, Gregory J. , Kotsenas, Amy L. , Lindell, E. Paul , Halaweish, Ahmed F., DeLone, David R. , Campeau, Norbert G , Halaweish, Ahmed F , Campeau, Norbert G. , McCollough, Cynthia H. , Fletcher, Joel G. , Diehn, Felix E

Mayo Clinic

Acta Radiologica Open | November 27, 2017 | Volume: 6 | Issue: 11 | Pages: 205846011774327

10.1177/2058460117743279 | PMID 29225924 Get It

Background Dental hardware produces streak artifacts on computed tomography (CT) images reconstructed with the standard weighted filtered back projection (wFBP) method. Purpose To perform a preliminary evaluation of an iterative metal artifact reduction (IMAR) technique to assess its ability to improve anatomic visualization over wFBP in patients with dental amalgam or other hardware. Material and Methods CT images from patients with dental hardware were reconstructed using wFBP and IMAR software and soft-tissue or bone window/level settings. The anatomy most affected by metal artifacts was identified. Two neuroradiologists determined subjective and objective imaging features, including overall metal artifact score (1 = severe artifacts, 5 = no artifacts), soft-tissue visualization score of the most-compromised structure, and artifact length along the skin surface. CT numbers were used to quantify artifact severity. Results Twenty-four patients were included. IMAR improved overall metal artifact score in 18/24 cases (median =2 ± 0.9 vs. 1 ± 0.6, P < 0.001). Mean CT number in the most-affected anatomical structure significantly improved with IMAR (94.6 vs. 219 HU, P = 0.002) and length of affected skin surface decreased (40.4 mm vs. 118.7 mm, P < 0.001). However, osseous/dental artifactual defects were found in 22/24 cases with IMAR vs. 11/24 with wFBP. Conclusion IMAR software reduced metal artifact both subjectively and objectively and improved visualization of adjacent soft tissues. However, it produced a higher rate of artifactual defects in the teeth and bones than wFBP. Our findings support the use of IMAR as a valuable complement to, but not a replacement for, standard wFBP image reconstruction.