Citations

Clear

188 citation(s) found for "Eleid, M".

The prevalence and natural history of mitral annulus calcification
Kato, Nahoko , Guerrero, M, Lee, A.T, Eleid, Mackram F. , Alkhouli, M.A, Rihal, C., Scott, Christopher G. , Nkomo, Vuyisile T. , Crestanello, Juan A. , Pislaru, Sorin V. , Pellikka, Patricia A.

Mayo Clinic

European Heart Journal | November 26, 2020 | Volume: 41 | Issue: Supplement_2 | Pages: No page available

10.1093/ehjci/ehaa946.2010 Get It

Abstract Background There is a paucity of data about the prevalence and natural history of mitral annular calcification (MAC). Purposes In a large cohort of patients undergoing clinically-indicated echocardiography, we aimed to evaluate the prevalence and the natural history of MAC, and the frequency of associated mitral valve dysfunction (MVD). Methods Retrospective review of all patients who underwent echocardiographic evaluation at our institution between January 1st and December 31st 2015. The patients were stratified into 3 groups: MAC with MVD, MAC without MVD, no MAC. MVD was defined as moderate or greater mitral regurgitation (MR) or stenosis (MS). The 3 groups were compared for baseline clinical and echocardiographic characteristics and all-cause mortality during follow-up. Results Of 24,415 evaluated patients, 5478 (22%) had MAC. Patients with MAC were older (75±10 vs. 60±16 years, p<0.01) and more often female (46% vs. 43%, p<0.01). MVD was more frequently observed in patients with MAC (16% vs. 7%, p<0.01); moderate or greater MR was found in 10% of patients with MAC vs. 6% without MAC (p<0.01) and MS in 7% vs. 0.5% (p<0.01). In patients with MAC, those with MVD were more often female and more frequently had creatinine ≥2mg/dl and moderate or greater aortic stenosis (AS) than those without MVD (Fig. A). Kaplan-Meier survivals at 1 year were 75% in patients with MAC and MVD, 87% in those with MAC without MVD, and 92% in those without MAC (Fig B). Adjusted for age, sex, diabetes, creatinine ≥2 mg/dl, coronary artery disease, left ventricular ejection fraction <50%, and AS, MAC was associated with higher all-cause mortality (adjusted hazard ratio1.4, 95% confidence interval: 1.3–1.5, p<0.01); combined MAC and MVD was associated with the highest mortality during follow-up of 2.5±1.8 years. Conclusion In a large cohort of patients undergoing echocardiographic evaluation, the prevalence of MAC was 22%. MV dysfunction was more than twice as prevalent in patients with MAC as without. Patients with MAC had higher all-cause mortality than patients without MAC. Among patients with MAC and mitral valvular dysfunction, adjusted mortality was two-fold higher compared to those without MAC. Funding Acknowledgement Type of funding source: None
Beat-to-beat variability in the tricuspid annulus dimensions and dynamics is markedly increased in atrial fibrillation
Ciobanu, A. , Wen, S, Thaden, J, Nkomo, V, Eleid, M, Ciobanu, Andrea O , Naser, Jwan A. , Pislaru, Cristina , Pellikka, Patricia A. , Pislaru, Sorin V.

Mayo Clinic

European Heart Journal | November 26, 2020 | Volume: 41 | Issue: Supplement_2 | Pages: No page available

10.1093/ehjci/ehaa946.0026 Get It

Abstract Background Atrial fibrillation (Afib) leads to beat-to-beat variability in cycle length; however, whether there is associated beat-to-beat variability in the tricuspid annulus (TA) dimensions or variability in the time in cardiac cycle when TA reaches maximal size is unknown. Purpose We aim to assess the beat-to-beat variability in the TA dimensions in Afib compared with sinus rhythm (SR). Methods Images were obtained from 58 patients (29 in Afib, 29 in SR) undergoing either 3D TTE or TEE examination. We measured TA in 3–6 cardiac cycles per patient using commercially available software (TomTec 4MV). Results Median absolute difference in maximal TA area over 3–6 cardiac cycles was 1.60 cm2 (range 0.35 cm2 to 4.08 cm2) in Afib vs. 1.17 cm2 (range 0.32 cm2 to 2.19 cm2) in SR, p=0.0063. Median absolute difference in the maximal circumference was 0.79 cm (range 0.09 cm to 2.2 cm) in Afib vs 0.54 cm (range 0.12 cm to 1.43 cm) in SR, p=0.0175. A total of 118 cardiac cycles were analyzed in patients in SR and 147 in Afib. Timing of maximal TA area was most commonly recorded at end-diastole (80–100% of the R-R interval) in 62% of cycles in SR; however, it was distributed over a broad range in Afib, p<0.0001, [Figure]. Conclusion Afib leads to significant beat-to-beat variability in the maximal TA area, minimal TA area, maximal TA circumference, and in the time of maximal TA area. These findings suggest that accurate assessment of TA dimensions should be based on continuous tracking of the TA over several cardiac cycles, especially in patients with Afib. These observations have significant implications for device sizing in percutaneous tricuspid valve interventions. Timing of Maximal TA Area Funding Acknowledgement Type of funding source: None
Contemporary differences between bicuspid and tricuspid aortic valve in chronic aortic regurgitation
Benfari, Giovanni , Eleid, Mackram F. , Scott, Christopher G. , Nkomo, Vuyisile T. , Pellikka, Patricia A. , Anavekar, Nandan S., Enriquez‐Sarano, Maurice , Michelena, Héctor I. , Yang, Li-Tan, Eleid, Mackram, Scott, Christopher , Nkomo, Vuyisile T , Pellikka, Patricia A , Michelena, Hector I , Enriquez-Sarano, Maurice , Benfari, Giovanni , Yang, Li‐Tan

Mayo Clinic

Heart | October 27, 2020 | Volume: 107 | Issue: 11 | Pages: 916-924

10.1136/heartjnl-2020-317466 | PMID 33109713 Get It

Objective To comprehensively explore contemporary differences between bicuspid aortic valve (BAV) and tricuspid aortic valve (TAV) patients with chronic haemodynamically significant aortic regurgitation (AR). Methods Consecutive patients with chronic ≥moderate-severe AR from a tertiary referral centre (2006–2017) were included. All-cause mortality, surgical indications and aortic valve surgery (AVS) were analysed. Results Of 798 patients (296 BAV-AR, age 46±14 years; 502 TAV-AR, age 67±14 years, p<0.0001) followed for 5.5 (IQR: 2.9–9.2) years, 403 underwent AVS (repair in 96) and 154 died during follow-up. The 8-year AVS incidence was 60%±3% versus 53%±3% for BAV-AR and TAV-AR, respectively (p=0.014). The unadjusted (real-life) 8-year total survival was 93%±7% versus 71%±2% for BAV-AR and TAV-AR, respectively (p<0.0001), and became statistically insignificant after sole adjustment for age (p=0.14). The within-group relative risk of death in BAV-AR patients demonstrated a large age-dependent increase (two fold at 50–55 years, up to 10-fold at 70 years). The presence of baseline symptoms was significantly associated with death for both BAV-AR (p=0.039) and TAV-AR (p<0.0001), but the strength of the association decreased with age adjustment for BAV-AR (age-adjusted HR 2.43 (0.92–6.39), p=0.07) and not for TAV-AR (age-adjusted HR, 2.3 (1.6–3.3), p<0.0001). As compared with general population, TAV-AR exhibited baseline excess risk which further increased at left ventricular ejection fraction (LVEF) <60% and left ventricular end-systolic dimension index (LVESDi) >20 mm/m2; similar thresholds were observed for BAV-AR patients. Conclusion BAV-AR patients were two decades younger than TAV-AR and underwent AVS more frequently, resulting in a considerable real-life survival advantage for BAV-AR that was determined primarily by age and not valve anatomy. Pragmatically, regardless of valve anatomy, patients with haemodynamically significant AR and age >50–55 years require a low-threshold for surgical referral to prevent symptom development where LVEF <60% and LVESDi >20 mm/m2 seem appropriate referral thresholds.
Effect of a fourth‐generation transcatheter valve enhanced skirt on paravalvular leak
Welle, Garrett A. , El‐Sabawi, Bassim , Thaden, Jeremy J. , Greason, Kevin L. , Klarich, Kyle W. , Holmes, David R. , Rihal, Charanjit S. , Eleid, Mackram F. , Alkhouli, Mohamad A, Holmes, David R , Eleid, Mackram F , Welle, Garrett A , Nkomo, Vuyisile T. , Alkhouli, Mohamad , Guerrero, Mayra , Crestanello, Juan A. , Rihal, Charanjit S.

Mayo Clinic

Catheterization and Cardiovascular Interventions | October 6, 2020 | Volume: 97 | Issue: 5 | Pages: 895-902

10.1002/ccd.29317 | PMID 33022117 Get It

AbstractObjectivesThe aim of this study was to assess the 30 day incidence of paravalvular leak (PVL) and need for aortic valve reintervention of a fourth generation balloon expandable transcatheter valve with enhanced skirt (4G‐BEV) (SAPIEN 3 Ultra) compared with a third generation balloon expandable transcatheter valve (3G‐BEV) (SAPIEN 3).BackgroundThe incidence of PVL has steadily declined with iterative improvements in transcatheter aortic valve replacement (TAVR) technology and implantation strategies.MethodsPatients who underwent TAVR at Mayo Clinic from 7/2018 to 7/2019 were included in a prospective institutional registry. 4G‐BEV has been utilized since 2/2019, and, after this date, 3G‐BEV and 4G‐BEV were simultaneously used. 4G‐BEV had three sizes (20, 23, and 26 mm) while 3G‐BEV included four sizes (20, 23, 26, and 29 mm). Both cohorts were evaluated at 30 days post‐TAVR with a transthoracic echocardiogram to assess for PVL.ResultsA total of 260 consecutive patients were included. Of these, 101 patients received a 4G‐BEV and 159 patients received a 3G‐BEV. There were more females (p = .0005) and a lower aortic valve calcium score (p = .02) in the 4G‐BEV cohort at baseline. Age, STS risk score, NYHA Class, and aortic valve mean gradient did not differ between groups. 4G‐BEV was associated with a lower incidence of mild PVL (10.8 vs. 36.5%; p < .0001) and moderate PVL (0 vs. 5.8%) compared to the 3G‐BEV at 30 days. There was no association between PVL and valve size in either cohort.ConclusionsUtilization of 4G‐BEV is associated with reduced PVL at 30 days post‐TAVR compared with 3G‐BEV.
Hemodynamic response to transseptal transcatheter mitral valve replacement in patients with severe mitral stenosis due to severe mitral annular calcification
Misumida, Naoki , Rihal, Charanjit S. , Eleid, Mackram F. , Eleid, Mackram F , Guerrero, Mayra , Pislaru, Sorin V. , Alkhouli, Mohamad , Rihal, Charanjit S.

Mayo Clinic

Catheterization and Cardiovascular Interventions | October 1, 2020 | Volume: 97 | Issue: 7 | Pages: No page available

10.1002/ccd.29285 | PMID 33002271 Get It

AbstractObjectivesWe aimed to investigate the invasive hemodynamic changes with transcatheter mitral valve replacement (TMVR) in patients with severe mitral stenosis due to severe mitral annular calcification.BackgroundThe hemodynamic response to TMVR in patients with mitral stenosis related to degenerative mitral annular calcification has not been fully elucidated.MethodsWe conducted retrospective review of patients who underwent successful transseptal TMVR with balloon‐expandable valves for symptomatic severe mitral stenosis due to mitral annular calcification at our institution between January 2014 and February 2020. Invasive hemodynamic measurements were obtained both before valve implantation (predeployment) and after (postdeployment).ResultsEighteen patients (age 72 ± 10 years, 44% female) were included for the analysis. There was a significant reduction in mean left atrial pressure (23.7 ± 5.6 mmHg versus 20.6 ± 4.8 mmHg; p = .01), left atrial v‐wave (mean 39.3 ± 10.2 mmHg versus 32.9 ± 9.9 mmHg; p = .01), and an increase in systemic mean blood pressure (72.6 mmHg ±11.2 versus 79.5 ± 9.9 mmHg; p = .02) postdeployment compared to predeployment. Patients who had symptom improvement at 30‐day follow‐up tended to have greater reduction in mean left atrial pressure (4.4 ± 4.4 mmHg versus 0.5 ± 5.2 mmHg; p = .16) and v‐wave (8.6 ± 9.0 mmHg versus 0.7 ± 8.4 mmHg; p = .10) compared to those who did not experience improvement of symptoms.ConclusionsTransseptal TMVR for severe mitral stenosis due to mitral annular calcification is associated with reductions in mean left atrial pressure and left atrial v‐wave, and an increase in systemic arterial pressure.
Transcatheter Mitral Valve Replacement After Surgical Repair or Replacement
Simonato, Matheus , Ribeiro, Henrique Barbosa , Webb, John G. , Backer, Ole De , Villablanca, Pedro, Rihal, Charanjit S. , Eleid, Mackram F. , Kempfert, Jörg , Unbehaun, Axel , Erlebach, Magdalena , Casselman, Filip , Saia, Francesco , Ubben, Timm , Meincke, Felix , Napodano, Massimo, Codner, Pablo , Schöfer, Joachim, Pelletier, Marc , Cheung, Anson , Shuvy, Mony , Palma, José Honório , Duncan, Alison , Sinning, Jan-Malte, Arbel, Yaron , Weger, Arend de , Eltchaninoff, Hélène, Hemery, Thibault, Tchétché, Didier , Dumonteil, Nicolas, Rodés‐Cabau, Josep , Kim, Won-Keun, Spargias, Konstantinos, Kourkoveli, Panagiota, Ben‐Yehuda, Ori , Barbanti, Marco , Fiorina, Claudia , Thukkani, Arun K., Jones, Noah, Presbitero, Patrizia , Petronio, Anna Sonia , Champagnac, Didier , Rudolph, Tanja K. , Iadanza, Alessandro , Nombela‐Franco, Luis , Bonaros, Nikolaos , Kass, Malek , Amabile, Nicolas , Messina, Antonio , Andreas, Martin , Welsh, Robert C. , Schoels, Wolfgang , Hellig, Farrel, Windecker, Stephan , Stortecky, Stefan , Maisano, Francesco , Stone, Gregg W. , Dvir, Danny , Rihal, Charanjit, Eleid, Mackram, Nombela-Franco, Luis , Windecker, Stephan , Maisano, Francesco , De Backer, Ole , Whisenant, Brian K. , Kornowski, Ran , Guerrero, Mayra , Wijeysundera, Harindra C. , Søndergaard, Lars , Rihal, Charanjit S. , Adam, Matti , Montorfano, Matteo , Ancona, Marco , Gaia, Diego Felipe , Hildick-Smith, David , Veulemans, Verena , Sinning, Jan‐Malte, Testa, Luca , Landes, Uri , Kim, Won-Keun, Teles, Rui Campante , Mackensen, G. Burkhard , Allali, Abdelhakim , Bleiziffer, Sabine , Salizzoni, Stefano , Agrifoglio, Marco , Bruschi, Giuseppe , Chhatriwalla, Adnan K , Hirji, Sameer

Mayo Clinic

Circulation | September 25, 2020 | Volume: 143 | Issue: 2 | Pages: 104-116

10.1161/circulationaha.120.049088 | PMID 32975133 Get It

Background: Mitral valve-in-valve (ViV) and valve-in-ring (ViR) are alternatives to surgical reoperation in patients with recurrent mitral valve failure after previous surgical valve repair or replacement. Our aim was to perform a large-scale analysis examining midterm outcomes after mitral ViV and ViR. Methods: Patients undergoing mitral ViV and ViR were enrolled in the Valve-in-Valve International Data Registry. Cases were performed between March 2006 and March 2020. Clinical endpoints are reported according to the Mitral Valve Academic Research Consortium (MVARC) definitions. Significant residual mitral stenosis (MS) was defined as mean gradient ≥10 mm Hg and significant residual mitral regurgitation (MR) as ≥ moderate. Results: A total of 1079 patients (857 ViV, 222 ViR; mean age 73.5±12.5 years; 40.8% male) from 90 centers were included. Median STS-PROM score 8.6%; median clinical follow-up 492 days (interquartile range, 76–996); median echocardiographic follow-up for patients that survived 1 year was 772.5 days (interquartile range, 510–1211.75). Four-year Kaplan-Meier survival rate was 62.5% in ViV versus 49.5% for ViR ( P <0.001). Mean gradient across the mitral valve postprocedure was 5.7±2.8 mm Hg (≥5 mm Hg; 61.4% of patients). Significant residual MS occurred in 8.2% of the ViV and 12.0% of the ViR patients ( P =0.09). Significant residual MR was more common in ViR patients (16.6% versus 3.1%; P <0.001) and was associated with lower survival at 4 years (35.1% versus 61.6%; P =0.02). The rates of Mitral Valve Academic Research Consortium–defined device success were low for both procedures (39.4% total; 32.0% ViR versus 41.3% ViV; P =0.01), mostly related to having postprocedural mean gradient ≥5 mm Hg. Correlates for residual MS were smaller true internal diameter, younger age, and larger body mass index. The only correlate for residual MR was ViR. Significant residual MS (subhazard ratio, 4.67; 95% CI, 1.74–12.56; P =0.002) and significant residual MR (subhazard ratio, 7.88; 95% CI, 2.88–21.53; P <0.001) were both independently associated with repeat mitral valve replacement. Conclusions: Significant residual MS and/or MR were not infrequent after mitral ViV and ViR procedures and were both associated with a need for repeat valve replacement. Strategies to improve postprocedural hemodynamics in mitral ViV and ViR should be further explored.
Edge-to-Edge Tricuspid Valve Repair for Severe Tricuspid Regurgitation 20 Years After Cardiac Transplantation
Misumida, Naoki , Steidley, D. Eric , Eleid, Mackram F.

Mayo Clinic

ESC Heart Failure | September 18, 2020 | Volume: 7 | Issue: 6 | Pages: 4320-4325

10.1002/ehf2.12992 | PMID 32945151 Get It

Abstract Tricuspid valve regurgitation in orthotopic heart transplant recipients is common. Surgical corrections have been the mainstay of the treatment for diuretic-refractory heart failure due to severe tricuspid regurgitation. However, post-transplant patients inherently carry higher surgical risk owing to previous sternotomy and immunocompromised state. We report a case of successful percutaneous edge-to-edge tricuspid valve repair for severe tricuspid regurgitation after cardiac transplantation. A 27-year-old man with a history of idiopathic restrictive cardiomyopathy status after orthotopic heart transplant presented with severe right-sided heart failure symptoms. A transthoracic echocardiogram showed bi-atrial enlargement and moderate-to-severe tricuspid regurgitation, and an increase to the severe range with exercise. Percutaneous edge-to-edge tricuspid valve repair was performed. The patient's symptoms improved, and follow-up echocardiogram showed mild tricuspid regurgitation. Percutaneous tricuspid valve repair can be considered as an alternative option to conventional surgery for symptomatic severe tricuspid regurgitation in orthotopic heart transplant recipients with suitable anatomy.
Temporal Trends in the Incidence and Outcomes of Pacemaker Implantation After Transcatheter Aortic Valve Replacement in the United States (2012–2017)
Kawsara, Akram , Sulaiman, Samian , Eleid, Mackram F. , Deshmukh, Abhishek , Cha, Yong‐Mei , Rihal, Charanjit S. , Alkhouli, Mohamad , Alkhouli, Mohamad , Alqahtani, Fahad , Rihal, Charanjit S.

Mayo Clinic

Journal of the American Heart Association | August 31, 2020 | Volume: 9 | Issue: 18 | Pages: No page available

10.1161/jaha.120.016685 | PMID 32862774 Get It

Background Nationwide studies documenting temporal trends in permanent pacemaker implantation (PPMI) following transcatheter aortic valve replacement (TAVR) are limited. Methods and Results We selected patients who underwent TAVR between 2012 and 2017 in the National Readmission Database. The primary end point was the 6‐year trend in post‐TAVR PPMI at index hospitalization and at 30, 90, and 180 days after discharge. The secondary end point was the association between PPMI and in‐hospital mortality, stroke, cost, length of stay, and disposition. Among the 89 202 patients who underwent TAVR, 77 405 (86.8%) with no prior pacemaker or defibrillator were included. Patients who required PPMI had a higher prevalence of atrial fibrillation (43.6% versus 38.7%, P <0.001) and conduction abnormalities (28.4% versus 15.3%, P <0.001). The incidence of PPMI during index admission increased from 8.7% in 2012 to 13.2% in 2015, and then decreased to 9.6% in 2017. The incidence of inpatient PPMI within 30 days after discharge increased from 0.5% in 2012 to 1.25% in 2017 ( P trend <0.001). Inpatient PPMI beyond 30 days remained rare (<0.5%) during the study period. After risk adjustment, PPMI was not associated with in‐hospital mortality or stroke but was associated with increased nonhome discharge, longer hospitalization, and higher cost. The incremental expenditure associated with post‐TAVR PPMI during index admission increased from $9.6 million to $72.2 million between 2012 and 2017. Conclusions After an upward trend, rates of PPMI after TAVR in the United States stabilized at ~10% in 2016 to 2017, but there was a notable increase in PPMI within 30 days after the index admission. PPMI was not associated with increased in‐hospital morbidity or mortality but led to longer hospitalization, higher cost, and more nonhome discharges.
A novel technique—Prophylactic septal radiofrequency ablation to prevent left ventricular outflow tract obstruction with transcatheter mitral valve replacement (RADIO‐TMVR)
Killu, Ammar M. , Siontis, Konstantinos C. , Sabbagh, Abdallah El , Eleid, Mackram F. , Rihal, Charanjit S. , Asirvatham, Samuel J. , Rihal, Charanjit, Asirvatham, Samuel J , Guerrero, Mayra , Alkhouli, Mohamad , Rihal, Charanjit S.

Mayo Clinic

Journal of Cardiovascular Electrophysiology | August 21, 2020 | Volume: 31 | Issue: 11 | Pages: 3048-3055

10.1111/jce.14720 | PMID 32820547 Get It

AbstractTranscatheter mitral valve replacement (TMVR) with off‐label use of aortic balloon‐expandable transcatheter heart valves has emerged as a therapeutic option in high‐surgical risk patients with severe mitral annular calcification. Left ventricular outflow tract (LVOT) obstruction post valve deployment is a major limitation. We describe a case of septal reduction therapy using radiofrequency ablation (RFA) when established methods of septal reduction were either ineffective or not feasible. RFA permitted successful enlargement of the LVOT area and subsequent TMVR.
Transient Complete Heart Block After Alcohol Septal Ablation
Cha, Yong‐Mei , Klarich, Kyle W. , Rihal, Charanjit S. , Eleid, Mackram F. , El-Sabawi, Bassim, Bradley, David J. , El‐Sabawi, Bassim , Nishimura, Rick A. , Rihal, Charanjit S.

Mayo Clinic

Circulation: Cardiovascular Interventions | August 6, 2020 | Volume: 13 | Issue: 8 | Pages: No page available

10.1161/circinterventions.120.009202 | PMID 32757660 Get It