Citations

Showing 10 of 107863 citations.

Sonication of Explanted Prosthetic Components in Bags for Diagnosis of Prosthetic Joint Infection Is Associated with Risk of Contamination
Trampuž, Andrej , Piper, Kerryl E., Hanssen, Arlen D. , Osmon, Douglas R. , Cockerill, Franklin R., Steckelberg, James M., Patel, Robin , Patel, Robin

Mayo Clinic

Journal of Clinical Microbiology | February 2, 2006 | Volume: 44 | Issue: 2 | Pages: 628-631

10.1128/jcm.44.2.628-631.2006 | PMID 16455930 Get It

ABSTRACT Explanted orthopedic implants from 54 patients with aseptic failure and 24 patients with prosthetic knee or hip infection were sonicated in polyethylene bags. The sensitivities of periprosthetic tissue and sonicate fluid cultures for the diagnosis of prosthetic joint infection were 54% and 75%, whereas the specificities were 98% and 87%, respectively. Sonication in bags improved bacterial recovery from the surface of orthopedic implants; however, it lacked specificity, due to bag leakage.
Evaluation of the Invader Assay for Genotyping Hepatitis C Virus
Germer, Jeffrey J., Yung, Billy, Mitchell, P. Shawn, Yao, Joseph D. , Majewski, David , Yung, Billy

Mayo Clinic

Journal of Clinical Microbiology | February 2, 2006 | Volume: 44 | Issue: 2 | Pages: 318-323

10.1128/jcm.44.2.318-323.2006 | PMID 16455877 Get It

ABSTRACT The Invader 1.0 assay (Invader HCV Genotyping Assay, version 1.0; Third Wave Technologies, Inc., Madison, WI) has been developed for the rapid differentiation of hepatitis C virus (HCV) genotypes 1 to 6 based on sequence variation within the HCV 5′ noncoding (NC) region. In the present study, we evaluated the compatibility of Invader 1.0 with the COBAS MONITOR (COBAS AMPLICOR HCV MONITOR Test, version 2.0; Roche Molecular Systems, Inc., Branchburg, NJ), COBAS AMPLICOR (COBAS AMPLICOR Hepatitis C Virus Test, version 2.0; Roche Molecular Systems, Inc.), and COBAS TaqMan (COBAS TaqMan HCV Test; Roche Molecular Systems, Inc.) assays. The minimum HCV RNA titers required for successful HCV genotyping (≥90% success rate) were 1,000 IU/ml for COBAS MONITOR, 100 IU/ml for COBAS AMPLICOR, and 10 IU/ml for COBAS TaqMan. Invader 1.0 results obtained from unpurified COBAS TaqMan amplification products of 111 retrospectively selected clinical serum specimens (genotypes 1 to 6, with virus titers ranging from 15.1 to 2.1 × 10 7 IU/ml) showed 98% concordance with results obtained from the TRUGENE HCV 5 ′ NC Genotyping Kit (Bayer HealthCare LLC, Tarrytown, NY), used in conjunction with COBAS AMPLICOR. Although the assay is sensitive, accurate, and easy to perform, additional optimization of the Invader 1.0 interpretive software (Invader Data Analysis Worksheet) may be necessary to reduce potential misidentification of HCV genotypes in low-titer specimens. In summary, Invader 1.0 is compatible with a variety of commercially available PCR-based HCV 5′ NC region amplification assays and is suitable for routine HCV genotyping in clinical laboratories.
Is Bladder Dysfunction and Incontinence Associated with Ureteroceles Congenital or Acquired?
Holmes, Nicholas M., Coplen, D.E. , Strand, William R., Husmann, Douglas A. , Baskin, Laurence S.

Mayo Clinic

Journal of Urology | February 2, 2006 | Volume: 168 | Issue: 2 | Pages: 718-719

10.1016/s0022-5347(05)64732-5 Get It

Competing Risk Analysis After Radical Prostatectomy for Clinically Nonmetastatic Prostate Adenocarcinoma According to Clinical Gleason Score and Patient Age
SWEAT, SUSAN D., Bergstralh, Erik J., Slezak, Jeffrey M., Blute, Michael L., Zincke, Horst

Mayo Clinic

Journal of Urology | February 2, 2006 | Volume: 168 | Issue: 2 | Pages: 525-529

10.1016/s0022-5347(05)64672-1 Get It

Renal Cell Carcinoma in the Solitary Kidney: An Analysis of Complications and Outcome After Nephron Sparing Surgery
Ghavamian, Reza , Cheville, John C. , Lohse, Christine M. , Weaver, Amy L. , Zincke, Horst, Blute, Michael L.

Mayo Clinic

Journal of Urology | February 2, 2006 | Volume: 168 | Issue: 2 | Pages: 454-459

10.1016/s0022-5347(05)64657-5 | PMID 12131287 Get It

Comparison of Rigiscan and Sleep Laboratory Nocturnal Penile Tumescence in the Diagnosis of Organic Impotence
Licht, Mark R., Lewis, Ronald W., Wollan, Peter C. , Harris, Cameron

Mayo Clinic

Journal of Urology | February 2, 2006 | Volume: 154 | Issue: 5 | Pages: 1740-1743

10.1016/s0022-5347(01)66773-9 Get It

The Incidence of High Grade Prostatic Intraepithelial Neoplasia in Needle Biopsies
Bostwick, David G., Qian, Junqi , Frankel, Kenneth A.

Mayo Clinic

Journal of Urology | February 2, 2006 | Volume: 154 | Issue: 5 | Pages: 1791-1794

10.1016/s0022-5347(01)66785-5 Get It

Novel Benzodiazepine Photoaffinity Probe Stereoselectively Labels a Site Deep within the Membrane-Spanning Domain of the Cholecystokinin Receptor
Hadac, Elizabeth M., Dawson, Eric S., Darrow, James W., Sugg, Elizabeth E., Lybrand, Terry P. , Miller, Laurence J.

Mayo Clinic

Journal of Medicinal Chemistry | February 2, 2006 | Volume: 49 | Issue: 3 | Pages: 850-863

10.1021/jm049072h | PMID 16451051 Get It

Popliteus Strain Causing Tibial Nerve Palsy with a Permanent Partial Deficit
Ortiguera, Cedric J. , Bremner, Barron R.B., Peterson, Jeffrey J.

Mayo Clinic

The American Journal of Sports Medicine | February 1, 2006 | Volume: 34 | Issue: 7 | Pages: 1176-1180

10.1177/0363546505284237 | PMID 16452266 Get It

Of Lobsters, Electronic Medical Records, and Neonatal Total Parenteral Nutrition
Costakos, Dennis T.

Mayo Clinic

Pediatrics | February 1, 2006 | Volume: 117 | Issue: 2 | Pages: e328-e332

10.1542/peds.2005-1350 | PMID 16452339 Get It

At the Mayo Health System in LaCrosse, Wisconsin, there are >1000 infant total parenteral nutrition (TPN) orders placed per year. It is the most complicated order that the pharmacy fills, so a recent peer-review article in Pediatrics moved a group of us to action at our center to buy or develop a TPN calculator. We did this because no stand-alone commercial calculators were available to us, and expensive electronic medical records typically do not include TPN calculators for neonatal patients. The new software includes decision support, and the orders are consistently legible. The physician performs fewer calculations, and there are no mathematical errors. This article examines the broader significance of providers having to write their own TPN software.