Citations

Showing 10 of 107930 citations.

Quantification of Serum 1–84 Parathyroid Hormone in Patients with Hyperparathyroidism by Immunocapture In Situ Digestion Liquid Chromatography–Tandem Mass Spectrometry
Barnidge, David R. , Chen, Li-Sheng, Twentyman, Jolaine M, Cradic, Kendall W, Grebe, Stefan K., Kumar, Vivek , Singh, Ravinder

Mayo Clinic

Clinical Chemistry | December 11, 2009 | Volume: 56 | Issue: 2 | Pages: 306-313

10.1373/clinchem.2009.134643 | PMID 20007860 Get It

Abstract Background: Immunoassays specific for 1–84 parathyroid hormone (PTH) reportedly reflect the bioactivity of PTH; however, PTH immunoassays can be susceptible to interference by cross-reacting PTH fragments. In addition, these assays currently lack standardization. A methodology using immunocapture purification with liquid chromatography–tandem mass spectrometry (LC-MS/MS) detection, along with a stable isotope–labeled internal standard, may help address these issues. Methods: We isolated 1–84 PTH from 1 mL serum by immunocapture on a 6.5-mm polystyrene bead. The immobilized PTH was digested in situ and analyzed by LC-MS/MS. For quantification, we used the selected reaction monitoring response from the N-terminal tryptic peptide 1–13 PTH (1SVSEIQLMHNLGK13). Results: The linear range of the assay was 39.1–4560 ng/L, and the limit of detection and limit of quantification were 14.5 ng/L and 39.1 ng/L, respectively. The intraassay CVs ranged from 6% to 11%, and the interassay CVs ranged from 7% to 17%. Interference by PTH fragments 1–44 PTH, 7–84 PTH, 43–68 PTH, 52–84 PTH, 64–84 PTH, and PTH-related protein (PTHrP) was ≤1% to ≤0.001%. Method comparison of LC-MS/MS vs the Roche Cobas® immunoassay yielded Deming fit of LC-MS/MS = 1.01x immunoassay – 13.21. The mean bias by Bland–Altman plot was −9.4%. Conclusions: In patients with hyperparathyroidism, the immunocapture in situ digestion LC-MS/MS method can provide accurate and precise PTH results compared with immunoassay.
Fluorescence in Situ Hybridization Testing Algorithm Improves Lung Cancer Detection in Bronchial Brushing Specimens
Voss, Jesse S. , Kipp, Benjamin R. , Halling, Kevin C. , Henry, Michael , Jett, James R., Clayton, Amy C., Rickman, Otis B.

Mayo Clinic

American Journal of Respiratory and Critical Care Medicine | December 10, 2009 | Volume: 181 | Issue: 5 | Pages: 478-485

10.1164/rccm.200907-1121oc | PMID 20007925 Get It

Abstract Rationale Bronchoscopically collected cytology specimens are commonly used to obtain a diagnosis of cancer in patients with pulmonary lesions. However, the sensitivity of cytology is suboptimal, especially for peripheral lesions less than 2 cm in diameter. Objectives We assessed the performance of a testing algorithm using cytology and fluorescence in situ hybridization (FISH) as part of clinical practice. Methods Bronchial brushing specimens (n = 343) were obtained from patients undergoing bronchoscopy for indeterminate pulmonary lesions. Routine cytology was performed and specimens without a positive diagnosis (n = 294) were analyzed by FISH, using residual brushing material. Pathology-confirmed lung cancer or clinical/radiographic evidence of disease was considered diagnostic of malignancy. Measurements and Main Results Routine cytology had a sensitivity and specificity of 41% (23 of 56) and 100% (45 of 45) for central lesions and 20% (26 of 133) and 100% (109 of 109) for peripheral nodules, respectively. FISH detected an additional 32% of lung cancers (18 central and 43 peripheral) not detectable by cytology alone, while producing false positive diagnoses in 22% (10 of 45) and 6% (6 of 109) benign central and peripheral lesions, respectively. In peripheral nodules, FISH detected (relative to routine cytology) an additional 44% (15 of 34) and 28% (25 of 91) of lung cancers less than 2 cm and 2 cm or more in size, respectively. A positive FISH result had a likelihood ratio of 1.45 and 5.87 for central and peripheral lesions and 3.44 and 15.38 for peripheral nodules less than 2 cm and 2 cm or more in size, respectively. Conclusions FISH testing significantly increases the detection of lung cancer over routine cytology alone. It is especially useful for peripheral nodules.
Imatinib Treatment for Idiopathic Pulmonary Fibrosis: Randomized Placebo-controlled Trial Results
Lasky, Joseph A. , Mieras, Kathleen, Gabor, Edith, Schroeder, Darrell R. , Selman, Moisés , Daniels, Craig , Limper, Andrew H. , Schroeder, Darrell

Mayo Clinic

American Journal of Respiratory and Critical Care Medicine | December 10, 2009 | Volume: 181 | Issue: 6 | Pages: 604-610

10.1164/rccm.200906-0964oc | PMID 20007927 Get It

Abstract Rationale Idiopathic pulmonary fibrosis (IPF) is a progressive lung disease with no known efficacious therapy. Imatinib is a tyrosine kinase inhibitor with potential efficacy to treat fibrotic lung disease. Objectives To investigate the safety and clinical effects of imatinib in patients with IPF. Methods We studied 119 patients in an investigator-initiated, multicenter, multinational, double-blind clinical trial to receive imatinib or placebo for 96 weeks. Measurements and Main Results Over 96 weeks of follow-up, imatinib did not differ significantly from placebo (log rank P = 0.89) for the primary endpoint defined as time to disease progression (10% decline in percent predicted FVC from baseline) or time to death. There was no effect of imatinib therapy on change in FVC at 48, 72, or 96 weeks (P ≥ 0.39 at all time points) or change in diffusing capacity of carbon monoxide at 48, 72, or 96 weeks (P ≥ 0.26 at all time points). Change in resting PaO2 favored imatinib therapy at 48 weeks (P = 0.005) but not at 96 weeks (P = 0.074). During the 96-week trial there were 8 deaths in the imatinib group and 10 deaths in the placebo group (log rank test P = 0.64). Thirty-five (29%) patients discontinued the study without reaching the primary endpoint (imatinib, 32%; placebo, 27%; P = 0.51). Serious adverse events (SAEs) were not more common in the imatinib group (imatinib, 18 SAEs in 17 patients; placebo, 19 SAEs in 18 patients). Conclusions In a randomized, placebo-controlled trial of patients with mild to moderate IPF followed for 96 weeks, imatinib did not affect survival or lung function. Clinical trial registered with www.clinicaltrials.gov (NCT00131274).
Early return visits by primary care patients: a retail nurse-practitioner clinic versus a medical office walk-in clinic
Rohrer, James E. , Angstman, Kurt B. , Furst, Joseph W.

Mayo Clinic

Primary Health Care Research & Development | December 10, 2009 | Volume: 11 | Issue: 1 | Pages: 87-92

10.1017/s1463423609990387 Get It

Aim The purpose of this study was to compare return visits in 2 weeks experienced by patients using a retail nurse-practitioner clinic to similar patients using standard drop-in clinic located in a medical office. Background Retail medicine clinics have become widely available. However, their impact on return visit rates compared to drop-in medical office visits for similar patients is unknown. Methods Medical records of primary care patients (both adults and children) seen in a large group practice in Minnesota in 2008 were analyzed for this study. Patients treated for five common conditions were selected (pink eye, sore throat, viral illness, bronchitis, and cough, n = 279). Two groups of patients were studied: those using a retail walk-in clinic staffed by nurse practitioners ( n = 142) and a comparison group using regular office care for same-day visits ( n = 137). The dependent variable was a return office visit within 2 weeks. Multiple logistic regression analysis was used to adjust for case mix differences between groups. Findings The percent of office visits within 2 weeks for these groups was 20.4 for retail drop-in patients and 27.7 for same-day medical office patients, respectively ( P = 0.15). After adjustment for age, gender, visit reason, and number of office visits in the previous 6 months, no significant difference in risk of early return visits in comparison to an office-based drop-in clinic was found (odds ratio 0.83, confidence interval 0.43–1.63). Our retail nurse-practitioner clinic appeared to increase access without increasing early return visits.
Differential Responses to Smith D Autoantigen by Mice with HLA-DR and HLA-DQ Transgenes: Dominant Responses by HLA-DR3 Transgenic Mice with Diversification of Autoantibodies to Small Nuclear Ribonucleoprotein, Double-Stranded DNA, and
Jiang, Chao , Deshmukh, Umesh S. , Gaskin, Felicia, Bagavant, Harini , Hanson, Julie A., David, Chella S., Fu, Shu Man

Mayo Clinic

The Journal of Immunology | December 10, 2009 | Volume: 184 | Issue: 2 | Pages: 1085-1091

10.4049/jimmunol.0902670 | PMID 20007529 Get It

Abstract Anti-Smith (Sm) D autoantibodies are specific for systemic lupus erythematosus. In this investigation, the influence of HLA-D genes on immune responses to SmD was investigated. Mice with HLA-DR3, HLA-DR4, HLA-DQ0601, HLA-DQ0604, or HLA-DQ8 transgenes were immunized with recombinant SmD1, and their Ab responses were analyzed. Analysis by ELISA showed that all strains responded well to SmD. However, when synthetic SmD peptides were used as substrate, DR3 mice had the highest Ab response followed by DQ8, DQ0604, DQ0601, and DR4. A similar trend was observed in Western blot analysis using WEHI 7.1 cell lysate as the substrate, with the exception that DR4 mice did not generate detectable amounts of Abs. Only sera from DR3 and DQ0604 mice immunoprecipitated A-ribonucleoprotein (RNP), SmB, and SmD. Intermolecular epitope spreading to A-RNP and SmB was evident in DR3 and DQ0604 mice, as sera depleted of anti-SmD Abs were reactive with these proteins. DR3 mice also generated an immune response to C-RNP. Anti-nuclear Abs were detected in the majority of the DR3 mice, whereas moderate reactivities were seen in DQ0604 and DQ8 mice. Interestingly, only DR3 mice mounted an anti-dsDNA Ab response. Approximately half of the anti-dsDNA Abs were cross-reactive with SmD. Ab responses correlated with the strength of the T cell responses. Thus, HLA-DR3 appears to be the dominant HLA-D gene that determines the magnitude and quality of the anti-SmD immune response. In addition, our findings provide insights into the origin of the anti-dsDNA Abs often detected in patients with systemic lupus erythematosus.
Evaluation of Three Multiplex Flow Immunoassays Compared to an Enzyme Immunoassay for the Detection and Differentiation of IgG Class Antibodies to Herpes Simplex Virus Types 1 and 2
Binnicker, Matthew J. , Jespersen, Deborah J., Harring, Julie

Mayo Clinic

Clinical and Vaccine Immunology | December 10, 2009 | Volume: 17 | Issue: 2 | Pages: 253-257

10.1128/cvi.00325-09 | PMID 20007366 Get It

ABSTRACT The diagnosis of herpes simplex virus (HSV) infections is routinely made based on clinical findings and supported by laboratory testing using PCR or viral culture. However, in instances of subclinical or unrecognized HSV infection, serologic testing for IgG class antibodies to type-specific HSV glycoprotein G (gG) may be useful. This study evaluated and compared the performances of three multiplex flow immunoassays (AtheNA Multi-Lyte [Zeus Scientific], BioPlex 2200 [Bio-Rad Laboratories], and Plexus HerpeSelect [Focus Diagnostics]) for the simultaneous detection of gG type-specific IgG antibodies to HSV types 1 and 2 (HSV-1 and HSV-2). Serum specimens ( n = 505) submitted for routine gG type-specific HSV IgG testing by enzyme immunoassay (EIA) (HerpeSelect; Focus Diagnostics) were also tested by the three multiplex flow immunoassays. Specimens showing discordant results were tested by HSV type-specific Western blotting (WB). For HSV-1 IgG, the AtheNA, BioPlex, and Plexus assays demonstrated agreements of 94.9% (479/505 specimens), 97.8% (494/505 specimens), and 97.4% (492/505 specimens), respectively, with the results of EIA. For HSV-2 IgG, the AtheNA, BioPlex, and Plexus assays showed agreements of 87.9% (444/505 specimens), 97.2% (491/505 specimens), and 96.8% (489/505 specimens), respectively, with EIA results. Timing studies showed that the AtheNA, BioPlex, and Plexus assays could provide complete analysis of 90 serum specimens in 3.1, 1.5, and 2.9 h, respectively, versus 3.1 h by EIA. These findings suggest that the gG type-specific HSV IgG multiplex immunoassays may be beneficial to high-volume clinical laboratories experiencing significant increases in the number of specimens submitted for HSV serologic testing. The evaluated systems provide comparable results to those of EIA, while reducing hands-on time and eliminating the necessity to aliquot specimens prior to testing.
Altered eosinophil profile in mice with ST6Gal-1 deficiency: an additional role for ST6Gal-1 generated by the P1 promoter in regulating allergic inflammation
Nasirikenari, Mehrab , Chandrasekaran, E. V., Matta, Khushi L., Bogner, Paul N. , Lugade, Amit A., Thanavala, Yasmin , Lee, James J. , Lau, Joseph T.Y. , Segal, Brahm H.

Mayo Clinic

Journal of Leukocyte Biology | December 10, 2009 | Volume: 87 | Issue: 3 | Pages: 457-466

10.1189/jlb.1108704 | PMID 20007243 Get It

Abstract ST6Gal-1 is a participant in regulating not only Th1 but also Th2 responses; ST6Gal-1 deficiency can lead to the development of more severe allergic inflammation with excessive eosinophil production. Cumulative evidence indicates that the sialyltransferase ST6Gal-1 and the sialyl-glycans, which it constructs, are functionally pleiotropic. Expression of the ST6Gal-1 gene is mediated by six distinct promoter/regulatory regions, and we hypothesized that these promoters may be used differentially to produce ST6Gal-1 for different biologic purposes. To examine this hypothesis, we compared a mouse with a complete deficiency in ST6Gal-1 (Siat1 null) with another mouse that we have created previously with a disruption only in the P1 promoter (Siat1ΔP1). We noted previously greater neutrophilic inflammation associated with ST6Gal-1 deficiency. Here, we report that ST6Gal-1-deficient mice also have significantly elevated eosinophilic responses. Upon i.p. thioglycollate elicitation, eosinophils accounted for over 20% of the total peritoneal inflammatory cell pool in ST6Gal-1-deficient animals, which was threefold greater than in corresponding wild-type animals. A principal feature of allergic respiratory inflammation is pulmonary eosinophilia, we evaluated the role of ST6Gal-1 in allergic lung inflammation. Using OVA and ABPA experimental models of allergic airways, we showed that ST6Gal-1 deficiency led to greater airway inflammation characterized by excessive airway eosinophilia. The severity of airway inflammation was similar between Siat1ΔP1 and Siat1 null mice, indicating a role for P1-generated ST6Gal-1 in regulating eosinophilic inflammation. Colony-forming assays suggested greater IL-5-dependent eosinophil progenitor numbers in the marrow of ST6Gal-1-deficient animals. Moreover, allergen provocation of wild-type mice led to a significant reduction in P1-mediated ST6Gal-1 mRNA and accompanied decline in circulatory ST6Gal-1 levels. Taken together, the data implicate ST6Gal-1 as a participant in regulating not only Th1 but also Th2 responses, and ST6Gal-1 deficiency can lead to the development of more severe allergic inflammation with excessive eosinophil production.
Affording Meaning: Design-Oriented Research from the Humanities and Social Sciences
Almquist, Julka, Lupton, Julia Reinhard

Mayo Clinic

Design Issues | December 9, 2009 | Volume: 26 | Issue: 1 | Pages: 3-14

10.1162/desi.2010.26.1.3 Get It

Development and Evaluation of an Observational Tool for Assessing Surgical Flow Disruptions and Their Impact on Surgical Performance
Laviana, Aaron A. , Wadhera, Rishi K. , Wiegmann, Douglas A. , Sundt, Thoralf M. , Parker, Sarah , Wadhera, Rishi K

Mayo Clinic

World Journal of Surgery | December 9, 2009 | Volume: 34 | Issue: 2 | Pages: 353-361

10.1007/s00268-009-0312-z | PMID 20012288 Get It

AbstractBackgroundMany researchers have previously explored the correlation between surgical flow disruptions and adverse events in cardiac surgery; however, there is no reliable tool to prospectively categorize surgical flow disruptions and the conditions that predispose a surgical team to adverse events.MethodsTwo independent raters of different medical and human factors expertise observed 12 cardiovascular operations and iteratively designed a surgical flow disruption tool (SFDT) to characterize surgical flow disruptions and the latent factors that contribute to adverse events. Categories to characterize surgical flow disruptions were created based on human factors models of human error. After the design period, both raters observed ten surgical cases using the tool to assess validity and inter‐rater reliability.ResultsRating agreement (weighted kappa) for each category across the ten surgeries was moderate to very high, resulting in strong inter‐rater reliability for each category on the surgical flow disruption tool. Use of the SFDT was simple and clear for observers of diverse backgrounds, including human factors experts and medical personnel.ConclusionsThis research depicts the development and utility of a tool to analyze surgical flow disruptions in the cardiovascular operating room with satisfactory inter‐rater reliability. This tool is an important first step in systematically categorizing and measuring surgical flow disruptions and their impact on patient safety in the operating room.
Risks and Adequacy of an Optimized Surgical Approach to the Primary Surgical Management of Papillary Thyroid Carcinoma Treated During 1999–2006
Grant, Clive S., Stulak, John M., Thompson, Geoffrey B. , Richards, Melanie L. , Reading, Carl C., Hay, Ian

Mayo Clinic

World Journal of Surgery | December 9, 2009 | Volume: 34 | Issue: 6 | Pages: 1239-1246

10.1007/s00268-009-0307-9 | PMID 20012290 Get It

AbstractBackgroundIntense disease surveillance and frequent lymph node metastases (LNMs) in papillary thyroid cancer (PTC) have resulted in increased locoregional recurrences. We examined the safety and efficacy of an optimized surgical approach including preoperative ultrasonograpy (US), bilateral thyroidectomy, routine compartment VI dissection, and lateral neck dissection for LNM.MethodsDuring 1999–2006, a total of 420 patients underwent optimized primary surgery; 291(69%) females, median age 46 years; follow‐up 98%, median 4.4 years. Patients were reviewed for tumor characteristics, pattern of LNM, staging, and outcomes.ResultsTotal or near‐total thyroidectomy was performed in 212 (51%) and 208 (49%) patients, respectively. Tumors were multicentric, 40% (average 1.7 cm); were bilateral, 30%; and showed extrathyroidal extension, 17%. Overall, 223 (53%) patients had LNMs: 213 (51%) were central and 85 (20%) were lateral jugular. pTNM staging: I, 258 (61%); II, 35 (8%); III, 88 (21%); IV, 39 (9%). AGES (age, grade, extension, and size—thyroid tumor; and MACIS (metastasis, age, completeness of resection, invasion, and size) prognostic scores were low risk in 362 (86%) and 352 (84%), respectively. Relapse developed in 57 (14%) patients: LNM in 44, soft tissue local recurrence (LR) in 5, distant metastases (DM) in 8. Hypoparathyroidism occurred in 5 (1.2%) patients and 1 had unintentional laryngeal nerve damage. Relapse with LNM occurred in previously operated fields in 19 (5%) patients, 11(3%) from disease virulence (LR or DM), preoperative false‐negative (FN) US in 12 (3%), and combination of FN‐US and recurrence in the operated field in 5 (1%) patients.ConclusionsRecurrence was limited to 5% of patients when the extent of disease was accurately defined and potentially curable. This optimized surgical strategy is relatively safe.