Citations

Showing 10 of 107940 citations.

First Aid for the Radiology Clerkship.
Olejniczak, S

Mayo Clinic

American Journal of Roentgenology | February 19, 2010 | Volume: 194 | Issue: 3 | Pages: W280-W280

10.2214/ajr.09.3499 Get It

Pocket Atlas of Radiographic Positioning, 2nd ed.
Olejniczak, S

Mayo Clinic

American Journal of Roentgenology | February 19, 2010 | Volume: 194 | Issue: 3 | Pages: W279-W279

10.2214/ajr.09.3498 Get It

PET and PET/CT: A Clinical Guide, 2nd ed.
Runyan, Brandon R.

Mayo Clinic

American Journal of Roentgenology | February 19, 2010 | Volume: 194 | Issue: 3 | Pages: W278-W278

10.2214/ajr.09.3464 Get It

MRI After Technically Successful Renal Cryoablation: Early Contrast Enhancement as a Common Finding
Porter, Christopher A. , Woodrum, David A. , Callstrom, Matthew R. , Schmit, Grant D. , Misra, Sanjay , Charboneau, J. William, Atwell, Thomas D. , Misra, Sanjay

Mayo Clinic

American Journal of Roentgenology | February 19, 2010 | Volume: 194 | Issue: 3 | Pages: 790-793

10.2214/ajr.09.2518 | PMID 20173161 Get It

Hydrodisplacement in the Percutaneous Cryoablation of 50 Renal Tumors
Bodily, Kale D., Atwell, Thomas D. , Mandrekar, Jayawant N. , Farrell, Michael A., Callstrom, Matthew R. , Schmit, Grant D. , Charboneau, J. William

Mayo Clinic

American Journal of Roentgenology | February 19, 2010 | Volume: 194 | Issue: 3 | Pages: 779-783

10.2214/ajr.08.1570 | PMID 20173159 Get It

Incidence of Bleeding After 15,181 Percutaneous Biopsies and the Role of Aspirin
Atwell, Thomas D. , Smith, R. L., Hesley, Gina K. , Callstrom, Matthew R. , Schleck, Cathy D. , Harmsen, William S. , Charboneau, J. William, Welch, Timothy J.

Mayo Clinic

American Journal of Roentgenology | February 19, 2010 | Volume: 194 | Issue: 3 | Pages: 784-789

10.2214/ajr.08.2122 | PMID 20173160 Get It

Stereotactic electroencephalography with temporal grid and mesial temporal depth electrode coverage: does technique of depth electrode placement affect outcome?
Meyer, Fredric B. , Marsh, W. Richard , Lee, Kendall H. , Gompel, Jamie J. Van , Worrell, Gregory A.

Mayo Clinic

Journal of Neurosurgery | February 19, 2010 | Volume: 113 | Issue: 1 | Pages: 32-38

10.3171/2009.12.jns091073 | PMID 20170311 Get It

Object Intracranial monitoring for temporal lobe seizure localization to differentiate neocortical from mesial temporal onset seizures requires both neocortical subdural grids and hippocampal depth electrode implantation. There are 2 basic techniques for hippocampal depth electrode implantation. This first technique uses a stereotactically guided 8-contact depth electrode directed along the long axis of the hippocampus to the amygdala via an occipital bur hole. The second technique involves direct placement of 2 or 3 4-contact depth electrodes perpendicular to the temporal lobe through the middle temporal gyrus and overlying subdural grid. The purpose of this study was to determine whether one technique was superior to the other by examining monitoring success and complications. Methods Between 1997 and 2005, 41 patients underwent invasive seizure monitoring with both temporal subdural grids and depth electrodes placed in 2 ways. Patients in Group A underwent the first technique, and patients in Group B underwent the second technique. Results Group A consisted of 26 patients and Group B 15 patients. There were no statistically significant differences between Groups A and B regarding demographics, monitoring duration, seizure localization, or outcome (Engel classification). There was a statistically significant difference at the point in time at which these techniques were used: Group A represented more patients earlier in the series than Group B (p < 0.05). The complication rate attributable to the grids and depth electrodes was 0% in each group. It was more likely that the depth electrodes were placed through the grid if there was a prior resection and the patient was undergoing a new evaluation (p < 0.05). Furthermore, Group A procedures took significantly longer than Group B procedures. Conclusions In this patient series, there was no difference in efficacy of monitoring, complications, or outcome between hippocampal depth electrodes placed laterally through temporal grids or using an occipital bur hole stereotactic approach. Placement of the depth electrodes perpendicularly through the grids and middle temporal gyrus is technically more practical because multiple head positions and redraping are unnecessary, resulting in shorter operative times with comparable results.
Computed tomographic angiography with three‐dimensional reconstruction for transoral laser microsurgery
Salassa, John R., Özgürsoy, Ozan Bağış , Weindling, Steven M. , Casler, John D.

Mayo Clinic

Otolaryngology–Head and Neck Surgery | February 19, 2010 | Volume: 142 | Issue: 3 | Pages: 351-354

10.1016/j.otohns.2009.11.028 | PMID 20172379 Get It

ObjectiveTo identify major arteries in relationship to large pharyngeal tumors during transoral laser microsurgery.Study DesignCase series with planned data collection.SettingMayo Clinic, Jacksonville, Florida.Subjects and MethodsWe developed a new technique that combines three‐dimensional CT angiography and enhanced soft‐tissue neck CT for evaluation of pharyngeal tumors before transoral laser microsurgery. Data from CT angiography were used to create three‐dimensional images of the tumor and adjacent arterial branches to better orient the surgeon to the spatial relationships of major arteries and pharyngeal tumors. Included were selected patients who had large tumors involving the pharynx and who underwent transoral laser microsurgery.ResultsEighteen patients were studied from June 2008 through January 2009. Tumor enhancement was absent or modest in four of 18 patients. Three of these four patients had superficial squamous cell carcinomas and one had adenoid cystic carcinoma. The remaining 14 patients had good tumor enhancement. The tumor involved the lingual artery in three and displaced the lingual or facial artery in two of these 14 patients. One anomalous right inferior thyroid artery was identified. Compared with routine enhanced soft‐tissue neck CT, three‐dimensional CT angiography greatly enhanced the anatomical relationships of the major arteries. In one patient, the surgeon's approach was changed after three‐dimensional CT angiography demonstrated an encased lingual artery.ConclusionThree‐dimensional CT angiography was useful in identifying the anatomical orientation of major arteries and the planning of transoral laser microsurgery to treat tumors involving the pharynx.
Regulation of Coronary Arterial BK Channels by Caveolae-Mediated Angiotensin II Signaling in Diabetes Mellitus
Lü, Tong , Zhang, Dai‐Min , Wang, Xiao-Li, He, Tongrong , Wang, Ruxing , Chai, Qiang , Katušić, Zvonimir S. , Lee, Hon-Chi, Wang, Xiao-Li, Lu, Tong

Mayo Clinic

Circulation Research | February 19, 2010 | Volume: 106 | Issue: 6 | Pages: 1164-1173

10.1161/circresaha.109.209767 | PMID 20167931 Get It

Rationale : The large conductance Ca 2+ -activated K + (BK) channel, a key determinant of vascular tone, is regulated by angiotensin II (Ang II) type 1 receptor signaling. Upregulation of Ang II functions and downregulation of BK channel activities have been reported in diabetic vessels. However, the molecular mechanisms underlying Ang II-mediated BK channel modulation, especially in diabetes mellitus, have not been thoroughly examined. Objectives : The aim in this study was to determine whether caveolae-targeting facilitates BK channel dysfunction in diabetic vessels. Methods and Results : Using patch clamp techniques and molecular biological approaches, we found that BK channels, Ang II type 1 receptor, G αq/11 (G protein q/11 α subunit), nonphagocytic NAD(P)H oxidases (NOX-1), and c-Src kinases (c-Src) were colocalized in the caveolae of rat arterial smooth muscle cells and the integrity of caveolae in smooth muscle cells was critical for Ang II-mediated BK channel regulation. Most importantly, membrane microdomain targeting of these proteins was upregulated in the caveolae of streptozotocin-induced rat diabetic vessels, leading to enhanced Ang II-induced redox-mediated BK channel modification and causing BK channel and coronary dysfunction. The absence of caveolae abolished the effects of Ang II on vascular BK channel activity and preserved BK channel function in diabetes. Conclusions : These results identified a molecular scheme of receptor/enzyme/channel/caveolae microdomain complex that facilitates the development of vascular BK channel dysfunction in diabetes.
Iothalamate Quantification by Tandem Mass Spectrometry to Measure Glomerular Filtration Rate
Seegmiller, Jesse C. , Burns, Bradley E., Fauq, Abdul H. , Mukhtar, Naveen, Larson, Timothy S., Lieske, John C.

Mayo Clinic

Clinical Chemistry | February 19, 2010 | Volume: 56 | Issue: 4 | Pages: 568-574

10.1373/clinchem.2009.133751 | PMID 20167698 Get It

Abstract Background: Glomerular filtration rate (GFR) can be determined by measuring renal clearance of the radiocontrast agent iothalamate. Current analytic methods for quantifying iothalamate concentrations in plasma and urine using liquid chromatography or capillary electrophoresis have limitations such as long analysis times and susceptibility to interferences. We developed a liquid chromatography–tandem mass spectrometry (LC-MS/MS) method to overcome these limitations. Methods: Urine and plasma samples were deproteinized using acetonitrile and centrifugation. The supernatant was diluted in water and analyzed by LC-MS/MS using a water:methanol gradient. We monitored 4 multiple reaction monitoring transitions: m/z 614.8–487.0, 614.8–456.0, 614.8–361.1, and 614.8–177.1. We compared the results to those obtained via our standard capillary electrophoresis (CE-UV) on samples from 53 patients undergoing clinical GFR testing. Results: Mean recovery was 90%–110% in both urine and plasma matrices. Imprecision was ≤15% for the m/z 614.8–487.0 and 614.8–456.0 transitions over a 10-day period at 1 mg/L. Method comparison for 159 patient samples (53 clearances) provided the following Passing–Bablok regressions: plasma iothalamate LC-MS/MS (y) vs CE-UV (x), y = 0.99x + 0.36; urine iothalamate LC-MS/MS vs CE-UV, y = 1.01x + 0.31; corrected GFR LC-MS/MS vs CE-UV, y = 1.00x + 0.00. Interfering substances prevented accurate iothalamate quantification by CE-UV in 2 patients, whereas these samples could be analyzed by LC-MS/MS. Conclusions: Iothalamate can be quantified by LC-MS/MS for GFR measurement. This method circumvents potential problems with interfering substances that occasionally confound accurate GFR determinations.