Citations

Institution: Mayo Clinic Clear

Showing 10 of 108195 citations.

Aveir Leadless Pacemaker implantation in pediatric population: a case series
Masilamani, Madhan , Cortez, Daniel , Masilamani, M S J

European Heart Journal | November 11, 2023 | Volume: 44 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehad655.601 Get It

Abstract Background While the Medtronic Micra pacemaker provided a small device for leadless pacemaker implantation, the Aveir device allows chronic retrievability and mapping prior to fixation. We present the first Aveir leadless pacemaker implantations in a pediatric population. Purpose To describe the first retrievable leadless pacemaker implants in children. Methods Retrospective review of pediatric Aveir implants occurred between November 2022 and December 2022. All patients were implanted via internal jugular vein insertion utilizing the Aveir sheath and catheter deployment system with mid-atrial approach taken prior to insertion of the catheter across the tricuspid valve. All patients had initial mapping of capture threshold, impedance and R-wave noted prior to deployment. Indications for pacing included sinus pauses and intermittent atrioventricular block. Results Three patients underwent Aveir leadless pacemaker implantation with weights of 32.3kg, 44kg, and 51kg. Capture thresholds were all 0.75Volts@0.2 milliseconds with impedance range of 370-1110 ohms, and R-waves of 8-14 millivolts (mV). Follow-up at 3 months ranged from 0.5V@0.2ms to 1V@0.2ms with impedances ranging 400-700 ohms, and R-wave 7-14 mV. At VVI 50-55bpm, with pacing ranged from 5% to 14%, predicted longevities ranged from 20 to 24.5 years at 3 months follow-up. Conclusion(s) Retrievable leadless pacemaker implantation is feasible in children and may offer good longevities for intermittent pacing need.Aveir Leadless Pacemaker in RVAveir Leadless Pacemaker in RV
Incidence and types of significant tricuspid regurgitation in atrial fibrillation and sinus rhythm
Pislaru, S V, Lin, Grace , Siontis, Konstantinos C. , Pellikkka, P A, Nkomo, V T, Naser, Jwan A. , Michelena, Héctor I. , Lee, E, Scott, Christopher G. , Kennedy, A M, Mankad, Rekha , Pellikkka, P A

European Heart Journal | November 11, 2023 | Volume: 44 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehad655.1760 Get It

Abstract Background Atrial fibrillation (AF) is associated with increased risk of incident tricuspid regurgitation (TR), but types of incident TR in AF versus sinus rhythm (SR) are not well-defined. Purpose We aimed to compare the risk of the different types of incident ≥moderate TR in AF and SR. Methods Adults first diagnosed with AF (2010-2021) who had a transthoracic echocardiogram (TTE) within 30 days after AF and adults with no diagnosis of AF who had a TTE in the same period were identified. Patients with previous cardiac surgeries, congenital heart disease, cardiomyopathy, cardiac devices, primary valve disease, previous or current ejection fraction (EF) <50%, severe diastolic dysfunction (SDD), ≥moderate left-sided valve disease (LVD), right ventricular systolic pressure (RVSP) ≥50 mmHg, ≥moderate TR, any tricuspid stenosis, or with no follow-up TTE ≥6 months from baseline were excluded. Patients were followed for the development of ≥moderate TR, the type of which was identified in a hierarchal order: 1) pacemaker-associated TR, 2) LVD-associated TR in the setting of ≥moderate LVD, 3) low EF or SDD-related TR, 4) pulmonary hypertension (PH)-associated TR if RVSP was ≥50 mmHg, 5) other ventricular functional TR (VFTR) if there was >mild RV enlargement or dysfunction, and 6) atrial functional TR (AFTR) when none of the previous was present. Patients were also followed for the occurrence of risk factors for TR (pacemaker insertion, ≥moderate LVD, low EF or SDD, PH, >mild RV enlargement or dysfunction) in a hierarchal order, and both the prevalence and future risk of the corresponding type of ≥moderate TR was determined at the onset of these conditions in AF and SR. Results Overall, 1,360 patients with new-onset AF (median age 67 years, 34% females) and 20,438 patients in SR (median age 60 years; 54% females) were included. Over median 3.8 (IQR 1.8-6.6) years, incident ≥moderate TR occurred in 110 patients with new-onset AF [2.13 per 100-person years] compared to 378 patients in SR [0.41 per 100-person years, p <.001]. All types of incident ≥moderate TR occurred more frequently in AF (p <.001 for all). The distribution and incidence of each type of TR in AF and SR are shown in Figure 1. The incidence of risk factors associated with the development of TR was higher in the AF group, except for pre-capillary PH, Figure 2A. At time of diagnosis or occurrence of these conditions, the prevalence of the corresponding TR types was higher in AF, except for pacemaker-TR, Figure 2B. The incidence of the corresponding TR type after occurrence of TR risk factors was higher in the AF group for LVD-TR and low EF/SDD-associated TR (p ≤0.03); although numerically higher in AF, the association was only borderline for PH-TR (p =0.05), Figure 2C. Conclusion Incident ≥moderate TR of all types occurred more frequently in patients with AF vs. SR and the distribution of TR types differed by rhythm. Patients with AF may benefit from a closer follow-up.Distribution and incidence rates of TRIncidence of TR risk factors & TR after
Real-world performance of a fully automatic antitachycardia pacing algorithm
Jackson, Troy , Taepke, Robert T., Birgersdotter‐Green, Ulrika , M, Y, DeGroot, Paul, Cheng, Alan , Yee, Raymond , Singh, Jagmeet P

European Heart Journal | November 11, 2023 | Volume: 44 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehad655.660 Get It

Abstract Background Antitachycardia pacing (ATP) found in most implantable cardioverter defibrillators (ICDs) is an important therapy for painless termination of ventricular tachycardias (VT). In ICDs programmed to guideline-recommended detection and therapy settings typical ATP success rates are 50-70%.[1-3] The first closed-loop, automated ATP (AATP) algorithm, introduced in 2021, applies an S1 train derived from the detected VT, followed by an S2 derived initially from a refractory period estimator and then adjusted using analysis of the post-pacing interval if ATP fails. The termination efficacy of AATP in the real-world population is unknown. Purpose To assess the effectiveness AATP in a large real-world population. Methods A database of de-identified ICD transmissions from subjects in the United States, Australia, Canada, and New Zealand was queried for AATP treated episodes. ICDs were randomly sampled, biased toward ICDs with multiple treated VT episodes. For rhythms classified as monomorphic ventricular tachycardia, each AATP pulse train was reviewed for: rhythm at delivery, effect of ATP, and any non-capturing pulses. Acceleration was defined as a post-ATP decrease in MVT cycle length (VTCL) of at least 10% and at least 30ms. Acceleration to polymorphic VT or ventricular fibrillation (PVT/VF) was assessed. Rates of termination and acceleration were calculated for all MVT and dichotomized using a 320ms VTCL cutoff. The method of generalized estimating equations (GEE) was used to correct event rates for multiple episodes from a single patient. Results There were 2281 episodes of MVT in 340 patients; 63% of patients had 2 or more episodes. There were 724 episodes with initial VTCL <320ms and 1557 episodes with VTCL ≥320ms. The rate of termination of MVT by AATP was 78% for all VTCL [95% CI: 74%-81%]. In 300 patients (88%) AATP terminated at least one MVT. For MVT with VTCL ≥320ms the termination rate was 80% [95% CI: 75%-83%] and for VTCL <320ms the termination rate was 75% [95% CI: 69%-80%]. The rate of acceleration was 3.6% [95% CI: 2.7%-4.9%], with a 0.8% rate of acceleration to PVT/VF [95% CI: 0.4%-1.8%]. Acceleration led to shock therapy in 63% of accelerated episodes. All MVT accelerated to PVT/VF either spontaneously terminated (4/14) or were successfully converted by a single shock therapy (10/14). All accelerations that remained MVT were successfully treated by the device with either subsequent ATP (35%) or shock therapy (61%), or spontaneously terminated (4%). Conclusion In this large, real-world cohort analysis, automated ATP’s termination rate exceeded the typical success rate of burst ATP, particularly for MVT <320ms. Acceleration to PVT/VF was low and effective first-shock defibrillation was consistent. Subsequent ATP for accelerated MVT had incremental benefit, leading to successful termination one-third of the time. Additional data are currently being prospectively collected in a separate post-approval study.
The role of serum lipoprotein(a) levels in bioprosthetic aortic valve degeneration
Fariña, Juliana, Roarke, M., Barry, Timothy, Sweeney, John P., Fortuin, David, Lester, Steven J., Oh, Jae K. , Marcotte, F, Pereyra, Milagros , Pereyra, Milagros , Farina, J, Chao, Chieh‐Ju , Said, E, Alsidawi, Said , Sell‐Dottin, Kristen , Ayoub, C, Arsanjani, Reza

European Heart Journal | November 11, 2023 | Volume: 44 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehad655.1616 Get It

Abstract Introduction Lipoprotein(a) [Lp(a)] is associated with an increased incidence of aortic stenosis. Bioprosthetic aortic valve degeneration and native aortic stenosis share similar pathological mechanisms. Evidence regarding the role of serum Lp(a) concentrations in bioprosthetic aortic valve degeneration is lacking. Purpose To evaluate the association between serum Lp(a) concentrations and bioprosthetic aortic valve degeneration. Methods In this retrospective multicenter study, consecutive patients who underwent a bioprosthetic aortic valve replacement between Jan-2010 and Dec-2020 and had a preoperatory serum Lp(a) measurement were included. A baseline transthoracic echocardiography (TTE) was performed following the aortic valve replacement and a follow-up TTE was performed at least 24 months after the baseline study to determine the presence of bioprosthetic valve degeneration. Significant degeneration was defined as: (a) an increase >10 mmHg in mean bioprosthetic aortic valve gradient from baseline status + a decrease in effective orifice area + a decrease in Doppler velocity index + exclusion of clinically thrombotic leaflet thickening, OR (b) new moderate or severe prosthetic aortic regurgitation (if the main component was periprosthetic, then it was not considered). Lp(a) concentrations were compared between patients with and without degeneration and regression analysis was conducted to investigate the association between bioprosthetic valve degeneration and Lp(a) levels. Results In total, 211 cases were included (mean age 74.1 ±9.4 years, 72.0% males, 29.9% transcatheter aortic valve replacements) (Figure 1). Median time between baseline and follow-up TTE was 5.0 (IQR 3.7) years. Bioprostheses degeneration was observed in 33 (15.6%) patients at follow-up. Median serum levels of Lp(a) were significantly higher in the patients affected by degeneration versus non-affected cases (50.0 vs 15.7 mg/dl, p=0.003). In the regression analysis, high Lp(a) levels (≥30 mg/dl) were associated with degeneration both in a univariate analysis (OR 4.8, 95%CI 2.2-10.9, p<0.001) and multivariate analysis adjusted by other risk factors for bioprostheses degeneration (age, sex, hypertension, smoking, patient prosthesis mismatch, creatinine levels, and body surface area) (OR 5.2, 95%CI 2.1-12.8, p<0.001). Conclusion Serum Lp(a) concentrations seem to be a risk factor for bioprosthetic aortic valve degeneration (Figure 2). There is an increasing need to accurately predict bioprosthetic aortic valve degeneration and to develop novel methods and treatments to increase their durability. Prospective studies are needed to confirm these findings and to investigate whether lowering Lp(a) could slow bioprostheses degradation.Population characteristicsLp(a) and bioprostheses degeneration
Diagnostic performance of the 0/2 hours ESC algorithm with high-sensitivity cardiac troponin T in an unselected community United States cohort
Ola, Oluwabukola Mary , Akula, Ashok , Knott, J D, Mehta, Roshni, Hodge, David O. , Tak, Tahir , Cagin, C, Gulati, R, Jaffe, Allan S. , Sandoval, Yader , Michieli, Laura De , Ola, O, Knott, Jonathan D , Mehta, R A, Jaffe, Allan S.

European Heart Journal | November 11, 2023 | Volume: 44 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehad655.1458 Get It

Abstract Background There are no robust data addressing the United States (US) experience with the 0/2 hours (h) European Society of Cardiology (ESC) algorithm using high-sensitivity cardiac troponin T (hs-cTnT). Purpose To evaluate the diagnostic performance of the 0/2h ESC-recommended absolute deltas in a US population. Methods Observational US cohort study of ED patients undergoing 0 and 2 h hs-cTnT measurements. The 99th percentiles upper reference limits (URL) used were 10 ng/L for women and 15 ng/L for men. Diagnostic outcomes were the adjudicated diagnoses of acute myocardial infarction (MI, type 1 or 2). Results A total of 1084 patients met inclusion criteria, amongst which 49% were women. Chest discomfort was reported in 521 (48%) patients. Among patients with a baseline hs-cTnT≤99th URL (n=434), 4 MIs occurred. To rule-out MI, an absolute 0-2h delta change <4 ng/L resulted in a sensitivity of 100% (95% CI: 39.8, 100) and a negative predictive value (NPV) of 100% (95% CI: 99.1, 100). To rule-in MI, an absolute 0-2h delta ≥10 ng/L had a specificity of 99.8 % (95% CI: 98.7, 99.9) and positive predictive value (PPV) of 75% (95% CI: 19.4, 99.4). Among patients with a baseline hs-cTnT >99th URL (n=650), 110 MIs occurred. In these patients, both rule-out (sensitivity 65%, NPV 91%) and rule-in (specificity 7.2%, PPV 11%) were poor using the ESC-recommended absolute deltas. Among patients with modest hs-cTnT increases (99th URL to 100 ng/L) neither the ESC-recommended absolute nor the Fourth Universal Definition of MI (UDMI)-recommended relative deltas provided acceptable performance. Among patients with marked hs-cTnT increases at presentation (>100 ng/L), a relative delta change >20% as recommended by the UDMI resulted in a superior rule-in performance, with a specificity of 92.0% (95% CI 74.0, 99.0) and PPV of 84.6% (57.4, 95.7). Conclusions In our unselected US-cohort of patients undergoing hs-cTnT, the 0/2h ESC algorithm had a good diagnostic performance in patients without myocardial injury at presentation. Conversely, in patients with myocardial injury at baseline, the ESC-recommended absolute deltas performed poorly to determine who had MI. In patients with marked hs-cTnT increases >100 ng/L at presentation, the UDMI recommended 20% relative change showed good rule-in performance.
Usefulness of Neutrophil-to-Lymphocyte Ratio (NLR) in predicting adverse outcomes in adult patients with heart failure : A systematic review and meta analysis
Pingili, Adhvithi , Katukuri, Nishanth , Bhanushali, Aditi Kishor , Vyas, Ankit , Mondal, A, Patel, B, Jain, Akhil , Desai, Rupak

European Heart Journal | November 11, 2023 | Volume: 44 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehad655.879 Get It

Abstract Background Inflammation plays a potential role in heart failure (HF) etiology and prognosis. Neutrophil-to-Lymphocyte ratio (NLR) is a simple, routinely available lab criteria. In this meta-analysis, we sought to investigate the role of NLR on HF outcomes which remains unexplored. Methods PubMed, Embase and Scopus were systematically screened to find studies through August 2022, reporting data on association of HF related outcomes [all-cause mortality (ACM), cardiovascular (CV) death, in-hospital, HF readmissions and composite events] and NLR. Random effects models and I2 statistics were used to estimate pooled odds of outcomes and heterogeneity. Leave one out sensitivity analysis was performed. Results A total of 11 studies (6 retrospective and 5 prospective, 4 studies from Asia and Europe each, 2 from the US and 1 multicenter study) including 12954 patients (mean age: 69 years, Males 57.2%) from 2011 to 2022 with an average follow up duration of 54.8 months were included. Elevated NLR was significantly associated with ACM (aOR 1.80, 95%CI 1.46-2.22, p<0.01, Table 1), HF readmissions (aOR 2.53, 95% CI 1.60-3.99), in-hospital mortality (aOR 3.26, 95% CI 1.76- 6.02), CV mortality (aOR 1.84, 95%CI 1.03-3.31) and composite CV outcome including heart transplant (OR 2.07, 95% CI 1.32-3.25), p<0.001. Conclusion Elevated NLR was significantly associated with worse outcomes in HF patients. The NLR test might potentially be useful in identifying high-risk HF patients and curtail worse outcomes.
Gamma-Glutamyl Transferase as a prognostic risk factor in complex coronary disease: a serendipitous (re)discovery of machine learning in the SYNTAXES?
Ninomiya, Kai, Kotoku, Nozomi , Masuda, Shinichiro , Revaiah, Pruthvi Chenniganahosahalli, Holmes, David R. , Serruys, Patrick W. , Kageyama, Shigetaka , O’Leary, Neil , Kappetein, A. Pieter , Onuma, Yoshinobu

European Heart Journal | November 11, 2023 | Volume: 44 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehad655.1215 Get It

Abstract Background/Introduction Over the last decade, epidemiology and pathology studies have suggested that gamma-glutamyl transferase (GGT) has an independent role in the pathogenesis and clinical evolution of cardiovascular diseases associated with atherosclerosis. Recently, machine learning (ML) algorithms have identified pre-procedural GGT as a significant predictor of long-term mortality after coronary revascularization in the SYNTAX trial. Purpose The aim of this study is to investigate the impact of pre-procedural GGT on 10-year all-cause mortality in patients with three-vessel disease (3VD) and/or left main coronary artery disease (LMCAD) following revascularization. Methods The SYNTAX trial was a randomized trial comparing percutaneous coronary intervention (PCI) with coronary artery bypass grafting (CABG) in 1,800 patients with complex CAD. The present report is a post-hoc sub-analysis of the SYNTAXES study, an investigator-driven extended 10-year follow-up of the SYNTAX trial. Before revascularization, blood samples were taken for GGT as well as other biological markers and analyzed by an independent central chemistry laboratory. The primary endpoint was all-cause mortality at 10-years. The changes in hazard for all-cause mortality in GGT over time were modelled using restricted cubic spline functions in a Cox regression model adjusted by age and sex. Subsequently, we compared survival in four groups defined by gender specific GGT thresholds of <32 IU and ≥32 IU for females and <64 IU and ≥64 IU for males, in accordance with prior studies. Results Out of 1,800 patients enrolled in the SYNTAX study, 167 (9.3%) did not have a GGT available at baseline and 1,633 (90.7%) patients were included in the present study. The mean values of GGT for males and females were 43.5±48.5 and 36.4±46.1 U/L, respectively. In the overall population a 10 U/L increase in GGT was significantly associated with 10-year all-cause death (adjusted hazard ratio [HR] 95% confidence interval [CI]: 1.03 [1.02–1.04], p <0.001, Figure A). For Kaplan–Meier analysis, patients were stratified into four groups according to previously reported sex related GGT thresholds. Ten-year mortality was numerically higher in males (adjusted HR 1.31, 95% CI: 0.90–1.91), and significantly higher in females (adjusted HR 1.88, 95% CI: 1.16–3.05) among patients with higher versus lower GGT (Figure B). Furthermore, GGT was significantly associated with CRP, a surrogate-marker of inflammation, as well as established cardiovascular risk biomarkers such as TG, total cholesterol, and glucose. Conclusions Preprocedural GGT is an independent predictor of 10-year mortality following coronary revascularization in patients with 3VD and/or LMCAD. This long-term association has been identified using ML algorithms and should be corroborated using data from large biobanks.Figure AFigure B
A comparison of general anesthesia versus monitored anesthesia care during catheter ablation for ventricular tachycardia
Woelber, T, Killu, Ammar M. , Deshmukh, A J, Woelber, Tiffany J., Dhawan, Rahul , Heybati, Kiyan , DeSimone, Christopher V. , Ramakrishna, Harish , Kowlgi, Gurukripa N.

European Heart Journal | November 11, 2023 | Volume: 44 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehad655.383 Get It

Abstract Background Catheter ablation of ventricular tachycardia (VT) may be performed under general anesthesia (GA) or monitored anesthesia care (MAC). There is a paucity of data studying these two sedation strategies with respect to intraprocedural characteristics, and outcomes of VT ablation. Purpose The purpose of this study was to assess the effects of anesthesia techniques on VT inducibility and outcomes. Methods A single-center, retrospective study of patients undergoing catheter ablation for scar-related VT, from 2016-2022, was conducted. Data collected included demographics, comorbidities, medications, relevant laboratory abnormalities, electrocardiograms, echocardiograms, detailed procedural characteristics, and outcomes. Results One hundred sixty-eight patients who underwent a total of 200 VT ablation procedures were included. The patients undergoing GA had a greater burden of comorbidities including congestive heart failure (77.2% vs. 60.9%), hypertension (66.9% vs. 60.0%), atrial arrhythmias (50.7% vs. 43.8%), diabetes mellitus (21.3% vs. 9.4%), chronic kidney disease (44.1% vs. 31.3%), prior stroke (11.8% vs. 10.9%), myocardial infarction (31.6% vs. 29.7%), pre-existing implantable cardioverter-defibrillator (86.8% vs. 71.9%) and had a higher median number of antiarrhythmic drugs at baseline (2 vs. 1) [Figure 1]. There was a greater percentage of patients with non-ischemic cardiomyopathy (58.1% vs. 51.6%) in the GA cohort. The mean left ventricular ejection fraction was not different among the two groups (39.3 ± 13.9 vs. 42.5 ± 15.3). The GA group had more hemodynamic instability at baseline (p < 0.01), and during VT induction (p < 0.01). There was no significant difference in the number of VT induced, or tachycardia cycle length, in each group. Despite higher radiofrequency energy delivery time in the GA group as compared to the MAC group, the GA group had higher VT inducibility post-procedure and were more likely to be discharged on antiarrhythmic drugs. Even though the recurrence of VT was higher in the GA group compared to the MAC group (41.9% vs. 31.3%), the VT-free survival curves were not significantly different by Kaplan-Meier analysis (p=0.19) [Figure 2]. In a multivariate regression analysis, the sedation strategy was not an independent predictor of VT recurrence (p=NS). However, baseline hemodynamic instability was an independent predictor of VT recurrence after accounting for all intraprocedural characteristics (p=0.008). Conclusion Patients undergoing VT ablation under GA have more comorbidities and tend to be on more antiarrhythmic drugs. The GA group had more hemodynamic instability during the procedure and had greater overall VT recurrence, however, not significant in a time-based analysis. The greater overall recurrence in the GA group could be because they represent a sicker population, or the hemodynamics during the procedure preclude adequate ablation of the VT circuit elements.Figure 1Figure 2
Prevalence and incidence of diastolic dysfunction in new-onset atrial fibrillation: implications for clinical and preclinical HFpEF
Pellikkka, P A, Lin, Grace , Pislaru, S V, Naser, Jwan A. , Lee, E, Scott, Christopher G. , Kennedy, A M, Pellikkka, P A, Borlaug, Barry A.

European Heart Journal | November 11, 2023 | Volume: 44 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehad655.1072 Get It

Abstract Background Atrial fibrillation (AF) and heart failure with preserved ejection fraction (HFpEF) are closely associated diseases that frequently coexist. However, due to the overlapping symptoms, the diagnosis of HFpEF can be overlooked with symptoms being attributed to AF. Purpose We aimed to investigate the prevalence of diastolic dysfunction (DD) in patients with new-onset AF compared to sinus rhythm (SR), study changes in diastolic function parameters over time in the two groups and compare the incidence of DD at follow-up. Methods Adults with new diagnosis of AF and adults in SR were identified. Patients with previous cardiac surgeries, congenital heart disease, hypertrophic or infiltrative cardiomyopathy, primary mitral disease, left-sided valve disease, low ejection fraction, enlarged left ventricle, or with no 6-month follow-up echocardiogram were excluded. Diastolic function was assessed through 4 components: mitral medial e’ <0.07 m/sec, mitral medial E/e’ >15 in SR and >11 in AF, TR velocity >2.80 m/sec, and left atrial volume index >34 ml/m2, with severe DD (SDD) defined by ≥3/4 findings and moderate DD (MDD) by ≥2/4 abnormal diastolic function parameters. Annualized changes were calculated as the difference between follow-up and baseline values divided by years in between. In a secondary analysis, patients with new-onset AF were propensity score-matched to patients with SR in a 3:1 ratio based on age, sex, body mass index, and comorbidities. Results Overall, 1,747 patients with incident AF (median age 67 years; 34% females) and 29,623 in SR (median age 59 years; 51% females) were included. New-onset AF was independently associated with the presence of SDD vs SR (8% vs 2%) and MDD (25% vs 11%, p<.001 for both in adjusted analysis). Over median follow-up of 3.2 (IQR 1.6-5.8) years, annualized severity progression in each of the 4 diastolic function parameters was greater in the AF group (p<.001 for all), Table. The incidence rates of SDD and MDD were 3.7 and 8.8 per 100-person year, respectively, in AF versus 1.1 and 3.6 per 100-person years, respectively, in SR (p<.001 for both at univariate and multivariable analysis), Figure. Results were similar in the propensity-score matched analysis. Conclusions Patients with new-onset AF more commonly have moderate or severe diastolic dysfunction that indicates the presence of potentially overlooked clinical HFpEF (when symptoms exist) or preclinical HFpEF (when symptoms are absent) compared to patients in SR. In long-term follow-up, patients with AF display accelerated progression in DD; suggesting that therapies to prevent progression to symptomatic HFpEF may be highest value in this patient population.
Chronic safety and performance of the extravascular ICD: results from the global EV ICD Pivotal study
Friedman, Paul A. , Murgatroyd, Francis , Manlucu, Jaimie , Leclercq, Christophe , Amin, Anish K. , Birgersdotter‐Green, Ulrika , Wiggenhorn, Christopher, Boersma, Lucas V.A. , Knight, Bradley P. , Clémenty, Nicolas , Merkely, Béla , Chan, J Y S, Biffi, Mauro , Knops, Reinoud Elwin , Crozier, Ian

European Heart Journal | November 11, 2023 | Volume: 44 | Issue: Supplement_2 | Pages: No page available

10.1093/eurheartj/ehad655.682 Get It

Abstract Background Implantable cardioverter defibrillators (ICDs) prevent sudden cardiac death in patients at high risk for ventricular arrhythmias, but conventional systems carry a risk of transvenous (TV) lead-related complications. The novel extravascular ICD (EV ICD) may reduce some of these complications, while offering anti-tachycardia pacing (ATP), pause prevention pacing, and a device of similar size and projected battery longevity as a TV ICD, by placing a lead substernally. The EV ICD Pivotal study demonstrated EV ICD safety and performance for termination of ventricular arrythmias at 6 months. Longer-term performance is unknown. Purpose To report the chronic safety and performance of the EV ICD system. Methods The extravascular implantable cardioverter defibrillator (EV ICD) Pivotal study was a prospective, international, single-arm, premarket clinical study. Patients with a class I or IIa indication for a single-chamber ICD per ESC or ACC/AHA/HRS guidelines were enrolled. Freedom from major system- and/or procedure-related complications at 18 mo was evaluated, as well as conversion of arrhythmias by anti-tachycardia pacing (ATP) or shock through all available follow up. Rates of ATP success were evaluated using the generalized estimating equation (GEE) and simple proportions. Results Implantation was attempted in 316 patients: 74.7% male, age 53.8±13.1 years, 82% primary prevention, left ventricular ejection fraction of 38.9%±15.4%, and New York Heart Association Class I (23.4%) or II/III (65.5%). Of 299 implanted patients (average follow up 16.2±7.2 mo), 19 experienced 80 spontaneous, appropriately treated arrhythmic episodes: 37 treated by ATP, 15 by ATP and shock, and 28 by shock alone with a Kaplan-Meier (KM) estimated 6.8% of patients experiencing appropriate therapy by 18 mo (Figure). Of discrete episodes treated with shock, 21/21 (100%) were successfully terminated. ATP was delivered in 12 patients, successfully treating 35/52 episodes (67.3%; GEE adjusted 59.0%). Inappropriate shocks occurred in 35 patients through all follow up, with a rate of 10.2% at 1 year. The KM estimate of freedom from major EV ICD system-or procedure-related complications rate through 18 mo was 91.9% (95% CI: 88.2% to 94.4%). The most common event was lead dislodgment (10 events in 9 patients) identified 0 to 120 days post-implant, predominantly due to anchoring technique. Conclusion The safety and effectiveness of a novel EV ICD system with a substernal lead extends through chronic follow up. Shocks were avoided in nearly half of all spontaneous episodes because of the availability of ATP.Figure