Objective This study evaluates the impact of international observerships organized by Help Ukraine Group (HUG) on professional development, knowledge transfer, and clinical practice improvement in radiation oncology in Ukraine. Methods A total of 50 observerships were facilitated for Ukrainian medical professionals at 14 institutions across the USA, Canada, Europe, and Australia from 2022 to 2024, including 31 radiation oncologists and medical physicists. A survey assessed their impact on oncology care, focusing on knowledge gained, lessons learned, and challenges in implementing new techniques. The primary outcome was the success score, defined as a composite score of implementing new procedures, initiating improvement projects, and knowledge dissemination efforts. Descriptive and comparative analyses examined satisfaction and success outcomes. Results A total of 43 respondents participated in the survey (response rate 86.0%). Twenty-eight of the responders were radiation oncology professionals (67.8% radiation oncologists, 32.1% medical physicists). The median observership duration for radiation oncology professionals was four weeks, with 96.4% also attending a professional conference. Overall satisfaction was high (mean 9.5 out of 10, median 10.0, IQR 9.0-10.0) while the success score was substantial (mean 6.1 out of 10, median 7.0, IQR 5.0-8.0). Time since certification influenced success, with ≥10 years’ experience associated with higher success scores (7.4 vs. 4.7, p=0.01). Importantly, 100% of respondents learned new procedures, 89.3% reported shifts in their clinical perspective, and 60.7% successfully implemented new techniques. Subsequent knowledge dissemination in Ukraine was substantial: 82.1% provided informal training, 60.7% delivered institutional or national presentations, 39.3% incorporated materials into lectures, and 10.7% engaged in all activities. Continued mentorship with host institutions was reported by 82.1%. Conclusions Amid the war, international observerships advanced clinical practice, education, and procedures in Ukraine, demonstrating the resilience of its medical community and providing a model that other LMICs/UMICs can follow.
Quantifying uncertainties associated with reference dosimetry in an MR‐Linac
AbstractBackgroundMagnetic resonance (MR)‐guided radiation therapy provides capabilities to utilize high‐resolution and real‐time MR imaging before and during treatment, which is critical for adaptive radiotherapy. This emerging modality has been promptly adopted in the clinic settings in advance of adaptations to reference dosimetry formalism that are needed to account for the presence of strong magnetic fields. In particular, the influence of magnetic field on the uncertainty of parameters in the reference dosimetry equation needs to be determined in order to fully characterize the uncertainty budget for reference dosimetry in MR‐guided radiation therapy systems.PurposeTo identify and quantify key sources of uncertainty in the reference dosimetry of external high energy radiotherapy beams in the presence of a strong magnetic field.MethodsIn the absence of a formalized Task Group report for reference dosimetry in MR‐integrated linacs, the currently suggested formalism follows the TG‐51 protocol with the addition of a quality conversion factor kBQ accounting for the effects of the magnetic field on ionization chamber response. In this work, we quantify various sources of uncertainty that impact each of the parameters in the formalism, and evaluate their overall contribution to the final dose. Measurements are done in a 1.5 T MR‐Linac (Unity, Elekta AB, Stockholm, Sweden) which integrates a 1.5 T Philips MR scanner and a 7 MVFFF linac. The responses of several reference‐class small volume ionization chambers (Exradin:A1SL, IBA:CC13, PTW:Semiflex‐3D) and Farmer type ionization chambers (Exradin:A19, IBA:FC65‐G) were evaluated throughout this process. Long‐term reproducibility and stability of beam quality, , was also measured with an in‐house built phantom.ResultsRelative to the conventional external high energy linacs, the uncertainty on overall reference dose in MR‐linac is more significantly affected by the chamber setup: A translational displacement along y‐axis of ± 3 mm results in dose variation of < |0.20| ± 0.02% (k = 1), while rotation of ± 5° in horizontal and vertical parallel planes relative to relative to the direction of magnetic field, did not exceed variation of < |0.44| ± 0.02% for all 5 ionization chambers. We measured a larger dose variation for xy‐plane (horizontal) rotations (< |0.44| ± 0.02% (k = 1)) than for yz‐plane (vertical) rotations (< ||0.28| ± 0.02% (k = 1)), which we associate with the gradient of kB,Q as a function of chamber orientation with respect to direction of the B0‐field. Uncertainty in Pion (for two depths), Ppol (with various sub‐studies including effects of cable length, cable looping in the MRgRT bore, connector type in magnetic environment), and Prp were determined. Combined conversion factor kQ× kB,Q was provided for two reference depths at four cardinal angle orientations. Over a two‐year period, beam quality was quite stable with being 0.669 ± 0.01%. The actual magnitude of was measured using identical equipment and compared between two different Elekta Unity MR‐Linacs with results agreeing to within 0.21%.ConclusionIn this work, the uncertainty of a number of parameters influencing reference dosimetry was quantified. The results of this work can be used to identify best practice guidelines for reference dosimetry in the presence of magnetic fields, and to evaluate an uncertainty budget for future reference dosimetry protocols for MR‐linac.