Citations

Mayo Clinic

Clear

37 citation(s) found for "Hafeez, M".

684: MEPOLIZUMAB PROPHYLAXIS IN EOSINOPHILIC COPD: A META-ANALYSIS
Shahid, Wajeeha, Amir, Muhammad Hamza, Minhas, Abdullah Rasheed, Nadeem, Aisha, Fatima, Mahnoor , Gul, Ahmad Hassan, Shahid, Talha , Hafeez, Ambreen , Burke, Timothy, Burke, Timothy

Critical Care Medicine | March 24, 2026 | Volume: 54 | Issue: 3S | Pages: No page available

10.1097/01.ccm.0001184732.81715.18 Get It

Woven EndoBridge Device for Ruptured vs. Unruptured Aneurysms: Insights from the WorldWideWEB Study
Dugar, Franja, Essibayi, Muhammed Amir, Adeeb, N, Algin, Oktay, Ghozy, Sherief, Guenego, Adrien, Renieri, Leonardo, Saliou, G, Shotar, Eimad, Möhlenbruch, Markus, Kral, Michael , Chung, Charlotte, Salem, Mohamed M , Cancelliere, Nicole M., Diestro, Jose Danilo Bengzon, Foreman, Paul M. , Shaikh, Hamza, Župančić, Vedran , Waqas, M, Ayberk, Gıyas , Rabinov, James D. , Maingard, Julian , Schirmer, Clemens M., Piano, M, Michelozzi, Caterina , Starke, Robert M., Hassan, A. E., Ogilvie, Mark, Jones, Jesse, Brinjikji, Waleed , Psychogios, Marios, Nawka, Marie Teresa , Fiehler, Jens, Nguyen-Kim, Thi Dan Linh, Pukenas, Bryan , Burkhardt, J. David, Huynh, Thien, Martinez-Gutierrez, Juan Carlos, Sheth, S, Slawski, Diana , Lubicz, Boris , Puri, A, Raz, E, Griessenauer, Christoph J., Asadi, Hamed, Siddiqui, Adnan, Levy, Elad I, Haranhalli, Neil , Altschul, David, Ducruet, Andrew F. , Regenhardt, Robert W., Stapleton, Christopher J. , Kan, Peter , Lylyk, Pedro, Boddu, Srikanth, Knopman, Jared, Tjoumakaris, Stavropoula I., Cuellar-Saenz, Hugo H., Jabbour, Pascal M., Clarençon, Frédéric, Patankar, Tufail , Pereira, Vitor Mendes, Patel, Aman B., Almohammad, Mohammad, Kemmling, Andre, Dmytriw, Adam A., Diestro, Jose Danilo Bengzon , Diestro, Jose Danilo B , Dugar, Franja , Essibayi, Muhammed Amir , Salim, Hamza , Musmar, Basel , Adeeb, Nimer , Dibas, Mahmoud , Li, Yan-Lin, Algin, Oktay , Ghozy, Sherief , Lay, Sovann V. , Guenego, Adrien , Renieri, Leonardo , Carnevale, Joseph, Saliou, Guillaume , Mastorakos, Panagiotis , Shotar, Eimad , Möhlenbruch, Markus , Salem, Mohamed Raafet Ben, Lylyk, Iván , Cancelliere, Nicole M , Hafeez, Muhammad Ubaid , Catapano, Joshua S , Waqas, Muhammad , Ayberk, Gıyas , Arslan, Muhammet , Ergun, Onur, Maingard, Julian, Schirmer, Clemens M. , Piano, Mariangela , Kühn, Anna L., Starke, Robert M., Hassan, Ameer, Ogilvie, Mark , Jones, Jesse , Zaccagna, Fulvio , Grist, James T. , Psychogios, Marios‐Nikos , Fiehler, Jens , Nguyen‐Kim, Thi Dan Linh , Burkhardt, Jan‐Karl , Huynh, Thien , Martinez-Gutierrez, Juan Carlos , Sheth, Sunil A , Tawk, Rabih G. , Pulli, Benjamin , Panni, Pietro , Puri, Ajit S., Pero, Guglielmo , Raz, Eytan , Griessenauer, Christoph J. , Asadi, Hamed , Siddiqui, Adnan H. , Levy, Elad I. , Altschul, David , Regenhardt, Robert W. , Kan, Peter , Kalousek, Vladimir , Lylyk, Pedro, Knopman, Jared , Tjoumakaris, Stavropoula , Cuellar, Hugo , Jabbour, Pascal , Clarençon, Frédéric , Limbucci, Nicola , Patel, Aman B. , Almohammad, Mohammad , Kemmling, André , Scarcia, Luca , Dmytriw, Adam A. , Sporns, Peter Bernhard

No container title available | March 18, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.21203/rs.3.rs-8939206/v1 Get It

Abstract Purpose Although the Woven EndoBridge (WEB) device is increasingly used for the treatment of wide-neck intracranial aneurysms, including in the acute rupture setting, comparative evidence assessing the impact of rupture status remains limited. This study compared angiographic, safety, and clinical outcomes between ruptured and unruptured intracranial aneurysms treated with WEB. Methods We conducted a retrospective analysis of prospectively collected data from the multicenter cohort registry WorldWideWEB, including consecutive adult patients with intracranial aneurysms treated with the WEB. Patients were stratified into groups of ruptured and unruptured aneurysms. Propensity score matching was used to balance baseline characteristics between both groups. Retreatment rate was the primary outcome. Secondary outcomes included mRS, safety events (thromboembolic complications) and angiographic outcomes (periprocedurally and last follow-up). Results Among 1,220 patients, 342 (28.0%) presented with ruptured aneurysms. There was no significant difference in the rate of thromboembolic complications between groups (11.8% vs 5.9%, p = 0.056). At follow-up, adequate occlusion was lower (82.2% vs 93.3%, p < 0.002) and functional outcomes were worse (mRS ≥2 in 34.1% vs 21.9%, p = 0.012) among patients with ruptured aneurysms. Periprocedural adequate occlusion (53.3% vs 53.8%, p>0.9) and retreatment rates (11.8% vs 7.1%, p = 0.14) did not differ between groups after matching. Conclusion Ruptured aneurysms demonstrated expected inferior follow-up functional and angiographic outcomes when compared with unruptured aneurysms, but no difference in retreatment rate and procedural safety. These findings support WEB as a safe and effective treatment option for appropriately selected ruptured intracranial aneurysms in routine clinical practice.
Atrial fibrillation through the lens of precision medicine: what clinicians need to know
Lamata, Pablo, Giudicessi, John R. , Krittanawong, Chayakrit , Namjouyan, Kamran , Lamata, Pablo , Virk, Hafeez Ul Hassan , Glicksberg, Benjamin S.

Future Cardiology | December 18, 2025 | Volume: 22 | Issue: 2 | Pages: 167-180

10.1080/14796678.2025.2603897 | PMID 41410542 Get It

Heparin Pretreatment in ST-Segment Elevation Myocardial Infarction: A Systematic Review and Meta-Analysis of Up-To-Date Evidence
Burhan, Muhammad , Virk, Hafeez Ul Hassan , Ahmed, Tarique , Daggubati, Ramesh , Burhan, Muhammad , Burhan, Muhammad , Tabassum, Shehroze , Naeem, Farhan , Qamar, Usama , Alraies, M Chadi , Sattar, Yasar

American Journal of Therapeutics | November 18, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1097/mjt.0000000000001981 | PMID 41250273 Get It

Predictive modeling of long-term improvement in occlusion outcomes following Woven EndoBridge treatment of cerebral aneurysms: A machine learning approach
Karandish, Alireza , Essibayi, Muhammed Amir , Jabal, Mohamed Sobhi , Salim, Hamza , Musmar, Basel , Adeeb, Nimer , Dibas, Mahmoud , Li, Yan-Lin , Grist, James T. , Lay, Sovann V. , Guenego, Adrien , Renieri, Leonardo, Naamani, Kareem El, Möhlenbruch, Markus, Kral, Michael , Salem, Mohamed M , Foreman, Paul M. , Shaikh, Hamza , Župančić, Vedran , Ayberk, Gıyas , Rabinov, James D. , Maingard, Julian , Michelozzi, Caterina , Starke, Robert M., Ogilvie, Mark , Nguyên, Anh , Jones, Jesse , Brinjikji, Waleed , Nawka, Marie Teresa , Psychogios, Marios, Ulfert, Christian , Pukenas, Bryan , Burkhardt, Jan‐Karl , Slawski, Diana , Lubicz, Boris , Puri, Ajit S., Pero, Guglielmo , Raz, Eytan , Asadi, Hamed , Siddiqui, Adnan H. , Haranhalli, Neil , Ducruet, Andrew F. , Albuquerque, Felipe C , Regenhardt, Robert W. , Stapleton, Christopher J. , Kan, Peter , Kalousek, Vladimir , Lylyk, Pedro , Boddu, Srikanth , Knopman, Jared , Tjoumakaris, Stavropoula , Clarençon, Frédéric , Patel, Aman B. , Fuschi, Maurizio , Altschul, David , Investigators, for the WorldWideWEB, Salim, Hamza , Li, Yan-Lin , Algin, Oktay , Ghozy, Sherief , Guenego, Adrien , Shotar, Eimad , Lylyk, Ivan , Foreman, Paul M , Župančić, Vedran , Hafeez, Muhammad U , Ayberk, Giyas , Schirmer, Clemens M , Hassan, Ameer E , Nguyen, Anh , Jones, Jesse , Ulfert, Christian , Tawk, Rabih, Raz, Eytan , Griessenauer, Christoph J , Siddiqui, Adnan H , Levy, Elad I , Regenhardt, Robert W , Tjoumakaris, Stavropoula , Cuellar-Saenz, Hugo H , Jabbour, Pascal , Limbucci, Nicola , Altschul, David J , Dmytriw, Adam A , Dibas, Mahmoud , Pero, Guglielmo , Kalousek, Vladimir , Musmar, Basel , Essibayi, Muhammed Amir , Lay, Sovann V , Simonato, Davide , Zaccagna, Fulvio , Ghozy, Sherief , Renieri, Leonardo , Carnevale, Joseph Anthony , Saliou, Guillaume , Mastorakos, Panagiotis , Naamani, Kareem El, Shotar, Eimad , Möhlenbruch, Markus , Chung, Charlotte , Lylyk, Iván , Hafeez, Muhammad Ubaid , Catapano, Joshua S , Waqas, Muhammad , Kazancı, Atilla , Schirmer, Clemens M. , Piano, Mariangela , Kühn, Anna Luisa , Hassan, Ameer E , Psychogios, Marios‐Nikos , Huynh, Thien , Martinez-Gutierrez, Juan Carlos , Sheth, Sunil A , Tawk, Rabih G. , Pulli, Benjamin , Panni, Pietro , Puri, Ajit S , Griessenauer, Christoph J. , Levy, Elad I. , Cuellar, Hugo , Jabbour, Pascal , Limbucci, Nicola , Dmytriw, Adam A. , Investigators, for the WorldWideWEB

Interventional Neuroradiology | November 3, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1177/15910199251391915 | PMID 41182964 Get It

Background The Woven EndoBridge (WEB) device represents an innovative solution for cerebral aneurysm occlusion, particularly for challenging wide-neck bifurcation aneurysms. However, factors affecting sustained occlusion remain poorly understood. We utilized machine learning to attempt to identify predictors of favorable long-term outcomes following WEB treatment. Methods In this multicenter retrospective study, we collected patient demographics, aneurysm characteristics, procedural details, and clinical outcomes. The primary endpoint was improvement in occlusion status, defined as maintained Raymond-Roy Occlusion Classification (RROC) grade 1, or improvement from grade 2 to 1, or from grade 3 to either 2 or 1 on final angiographic follow up. The dataset was split into training (75%) and validation (25%) sets. The CatBoost algorithm was selected based on performance metrics, with Shapley Additive exPlanations (SHAP) values calculated to determine feature importance. Furthermore, a multivariable binomial logistic regression model was performed to validate machine learning findings. Results Among 720 aneurysms from 36 hospitals, 84% showed improvement in occlusion at follow up. Both machine learning and multivariable logistic regression identified aneurysm height as the most consistent correlate of nonimprovement (odds ratio (OR) 0.90 per mm, p = 0.022). In the CatBoost model, the highest-ranking features by SHAP included aneurysm height, patient age, treatment acuity, ACom location, WEB-SLS device, bifurcation anatomy, aneurysm multiplicity, baseline modified Rankin Scale, access route, and partial thrombosis. Conclusions Machine-learning and regression analyses identified consistent predictors of occlusion improvement after WEB treatment, with aneurysm height most strongly linked to nonimprovement. These insights may guide patient selection and follow up. Findings require cautious interpretation and external validation in larger cohorts.
Demographic Trends in Mortality Related to Gastric Cancer in the United States, 1999 to 2022
Dhali, Arkadeep , Faisal, Abdul Rafae , Maity, Rick , Zaman, Asad, Majeed, Mamoona, Hafeez, Ali Shan , Abdullah, Abdullah , Razaq, Laiba, Humayun, Mohammad Abdullah, Qadri, Henna, Dhali, Arkadeep , Maity, Rick , Faizan, Muhammad, Singh, Pramod , Zaman, Asad, Humayun, Mohammad Abdullah

Journal of Clinical Gastroenterology | October 13, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1097/mcg.0000000000002244 | PMID 41081713 Get It

Background: Gastric cancer remains one of the leading causes of death globally and a major health concern. This study aims to analyze gastric cancer-related mortality trends over 2 decades. Methods: The CDC WONDER database was used to analyze and stratify de-identified death certificates from 1999 to 2022 across the United States. Trends in age-adjusted mortality rates (AAMR) were assessed using the Joinpoint Regression Program to determine annual percentage changes. Results: Overall, AAMR decreased from 79.26 in 1999 to 44.81 in 2022. Men and older adults had the highest AAMRs. Non-Hispanic (NH) Black or African Americans had the highest AAMR, while NH Whites had the lowest. Geographically, the Northeast had the highest AAMR, and metropolitan areas had higher AAMRs than nonmetropolitan areas. Conclusion: Gastric carcinoma has a poor prognosis, and although the general trend is decreasing across all sociodemographic areas, further research is required for targeted interventions and health policies for high-risk populations.
Personalizing Mechanical Circulatory Support for Cardiogenic Shock: A Review and Comparison of Current Devices
Fujiuchi, Bradley, Benavente, Kevin , Virk, Hafeez Ul Hassan , Alam, Mahboob , Tedford, Ryan J. , Krittanawong, Chayakrit , Tedford, Ryan J , Krittanawong, Chayakrit , Hassan Virk, Hafeez Ul , Jentzer, Jacob C. , Diepen, Sean van

Catheterization and Cardiovascular Interventions | June 23, 2025 | Volume: 106 | Issue: 2 | Pages: 1446-1458

10.1002/ccd.31698 | PMID 40545708 Get It

ABSTRACT Cardiogenic shock (CS) remains a high morbidity and mortality condition worldwide frequently complicating acute myocardial infarction (AMI) and decompensated heart failure (HF). Within the management of CS, mechanical circulatory support (MCS) devices play a critical role in maintaining hemodynamic stability, preserving end‐organ perfusion and bridging patients through to recovery, implantation of durable support or transplantation. Despite their use, optimal timing of initiation, as well as patient and device selection remain unclear. This review explores the current landscape of MCS devices, surrounding evidence and key distinctions between devices. With increasing acknowledgment for the heterogeneity of CS, understanding the strengths and limitations of each device remains crucial to improving outcomes in this high‐risk population.
Efficacy and Safety of Cryoballoon Versus Radiofrequency Ablation for Persistent Atrial Fibrillation: A Meta-Analysis of Randomized Controlled Trials
Burhan, Muhammad , Balbaa, Elsayed, Imtiaz, Zeeshan , Ibrahim, Ahmed M. , Virk, Hafeez Ul Hassan , Munir, Muhammad Bilal, Munir, Muhammad Bilal , Burhan, Muhammad , Munir, Muhammad Bilal , Burhan, Muhammad , Ibrahim, Ahmed , Balbaa, Elsayed , Naeem, Farhan , Qamar, Usama , Tabassum, Shehroze , Ahmed, Raheel , Asad, Zain Ul Abideen

Cardiology in Review | May 22, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1097/crd.0000000000000947 | PMID 40401921 Get It

Managing persistent atrial fibrillation (AF) remains challenging due to its complex arrhythmic substrate, and pulmonary vein isolation through catheter ablation remains the primary treatment. This meta-analysis aims to compare the efficacy and safety outcomes of cryoballoon ablation (CBA) and radiofrequency ablation (RFA) in patients with persistent AF to provide evidence-based insights for clinical decision-making. A systematic search of PubMed, Embase, and Cochrane Central was conducted following PRISMA guidelines. Randomized controlled trials (RCTs) comparing CBA and RFA in persistent AF were included. Data on efficacy, safety, and procedural outcomes were pooled in the form of odds ratios (ORs) or mean differences (MDs) with corresponding 95% confidence intervals (CIs) using the random effects model in the Review Manager (RevMan) software. Four RCTs comprising 899 patients were included in our analysis. There were no significant differences between CBA and RFA in terms of AF recurrence, atrial tachycardia/flutter recurrence, or any arrhythmia recurrence during a mean follow-up period of 18 months after ablation. Procedure time was significantly shorter with CBA (MD: −44.85 minutes, 95% CI: −56.46 to −32.24, P < 0.01), while fluoroscopy time was comparable between the 2 groups (MD: 4.31 minutes, 95% CI: −1.79 to 10.40, P = 0.17). Safety outcomes, including overall complications, phrenic nerve palsy, access-site complications, and pericardial effusion, showed no significant differences between the 2 groups. CBA and RFA show similar rates of atrial arrhythmia recurrence and periprocedural complications in the treatment of persistent AF, while CBA offers the advantage of a shorter procedure time.
Large‐Bore Thrombectomy Versus Catheter‐Directed Thrombolysis for Acute Intermediate & High‐Risk Pulmonary Embolism: A Meta‐Analysis of Up‐to‐Date Evidence
Naeem, Farhan , Qamar, Usama , Ashraf, Hadiah , Daggubati, Ramesh , Virk, Hafeez Ul Hassan , Alraies, M Chadi , Virk, Hafeez Ul Hassan , Qamar, Usama , Tabassum, Shehroze

Catheterization and Cardiovascular Interventions | May 14, 2025 | Volume: 106 | Issue: 1 | Pages: 576-580

10.1002/ccd.31576 | PMID 40364577 Get It

Higher risk of recurrence in partially thrombosed cerebral aneurysms post-WEB (Woven EndoBridge) device treatment: insights from the WorldWideWEB Consortium registry
Saliou, Guillaume , Salim, Hamza , Musmar, Basel , Adeeb, Nimer , Aslan, Assala , Swaid, Christian, Cuellar, Miguel, Dibas, Mahmoud , Cancelliere, Nicole M , Diestro, Jose Danilo Bengzon , Lay, Sovann V. , Guenego, Adrien , Möhlenbruch, Markus , Kral, Michael , Salem, Mohamed M , Foreman, Paul M. , Shaikh, Hamza , Župančić, Vedran , Rabinov, James D. , Ren, Yifan , Michelozzi, Caterina , Starke, Robert M. , Ogilvie, Mark , Nguyên, Anh , Jones, Jesse , Brinjikji, Waleed , Nawka, Marie Teresa , Psychogios, Marios‐Nikos , Ulfert, Christian , Pukenas, Bryan , Burkhardt, Jan Karl, Slawski, Diana , Pulli, Benjamin , Lubicz, Boris , Puri, Ajit S , Pero, Guglielmo , Raz, Eytan , Asadi, Hamed , Siddiqui, Adnan H. , Haranhalli, Neil , Altschul, David , Ducruet, Andrew F. , Albuquerque, Felipe C , Regenhardt, Robert W. , Stapleton, Christopher J. , Kan, Peter , Kalousek, Vladimir , Lylyk, Pedro , Boddu, Srikanth , Knopman, Jared , Tjoumakaris, Stavropoula , Jabbour, Pascal , Clarençon, Frédéric , Patel, Aman B. , Salim, Hamza , Ghozy, Sherief , Lay, Sovann V , Guenego, Adrien , Carnevale, Joseph Anthony , ElNaamani, Kareem , Shotar, Eimad , Chung, Charlotte , Salem, Mohamed M , Lylyk, Ivan , Shaikh, Hamza A , Hafeez, Muhammad U , Catapano, Joshua S , Ren, Yifan , Schirmer, Clemens M , Michelozzi, Caterina , Hassan, Ameer E , Ogilvie, Mark , Nguyen, Anh , Jones, Jesse , Brinjikji, Waleed , Nawka, Marie Teresa , Huynh, Thien J, Martinez-Gutierrez, Juan Carlos , Essibayi, Muhammed Amir , Sheth, Sunil A , Tawk, Rabih G , Pulli, Benjamin , Pero, Guglielmo , Raz, Eytan , Griessenauer, Christoph J , Siddiqui, Adnan H , Levy, Elad I , Albuquerque, Felipe C , Stapleton, Christopher , Kan, Peter , Kalousek, Vladimir , Tjoumakaris, Stavropoula , Cuellar-Saenz, Hugo H , Jabbour, Pascal , Dmytriw, Adam A , Hajdu, Steven D , Dibas, Mahmoud , Diestro, Jose Danilo B , Saliou, Guillaume , Altschul, David J , Musmar, Basel , Regenhardt, Robert W , Cancelliere, Nicole M , Ulfert, Christian , Burkhardt, Jan‐Karl , Cuellar, Miguel, Algin, Oktay , Ghozy, Sherief , Renieri, Leonardo , Mastorakos, Panagiotis , Naamani, Kareem El , Shotar, Eimad , Lylyk, Iván , Hafeez, Muhammad Ubaid , Waqas, Muhammad , Arslan, Muhammet , Ergün, Onur , Schirmer, Clemens M. , Piano, Mariangela , Kühn, Anna Luisa , Hassan, Ameer E , Huynh, Thien , Essibayi, Muhammed Amir , Tawk, Rabih G. , Panni, Pietro , Griessenauer, Christoph J. , Levy, Elad I. , Cuellar, Hugo , Limbucci, Nicola , Mendes Pereira, Vitor , Dmytriw, Adam A.

Journal of NeuroInterventional Surgery | April 30, 2025 | Volume: 18 | Issue: 3 | Pages: 782-789

10.1136/jnis-2024-022628 | PMID 40306928 Get It

Background The Woven EndoBridge (WEB) device is a prevalent treatment for intracranial aneurysms. While many studies have assessed the obliteration rate post-WEB embolization, few have focused on long-term outcomes in partially thrombosed aneurysms. Objective To assess whether partially thrombosed aneurysms are at higher risk of recurrence or retreatment following WEB embolization compared with non-thrombosed aneurysms. Methods We evaluated data from 22 academic institutions, focusing on previously untreated cerebral aneurysms treated with the WEB device. Logistic regression was utilized to analyze factors predicting long-term aneurysm obliteration and retreatment necessity. Results Among 1303 patients, 26 presented with a partially thrombosed aneurysm. In the partially thrombosed group, the mean aneurysm maximal diameter was 10.7±4 mm with a neck ratio of 1.99±1.19 mm, larger than in the control group where the mean aneurysm maximal diameter was 6.81±2.37 mm with a neck ratio of 1.64±0.51 mm (P<0.001 for both maximal diameter and neck ratio). At the final follow-up, partially thrombosed aneurysms treated by the WEB device had a 38.5% retreatment rate, compared with 7.0% for non-thrombosed aneurysms (P<0.001). Among partially thrombosed aneurysms, the Raymond-Roy type IIIa/b occlusion rate was higher (38.5% vs 9.9%, P<0.001). On multivariate analysis, partially thrombosed aneurysms compared with non-thrombosed aneurysms had an increased rate of retreatment (OR 3.64, 95% CI 1.28 to 10.1). Conclusion Partially thrombosed aneurysms are associated with a poorer occlusion rate and a higher rate of retreatment following WEB embolization. For partially thrombosed aneurysms, the WEB device appears suboptimal as a first-line treatment, and therefore alternative techniques should be prioritized.