Citations

Mayo Clinic

Clear

3 citation(s) found for "Fung, Christopher".

Comparing FIB-4, VCTE, pSWE, 2D-SWE, and MRE Thresholds and Diagnostic Accuracies for Detecting Hepatic Fibrosis in Patients with MASLD: A Systematic Review and Meta-Analysis
Wilson, Mitchell P. , Singh, Ranjit , Mehta, Shyam B. , Fung, Christopher , Low, Gavin , Wilson, Mitchell Patrick , Murad, Mohammad Hassan, Fung, Christopher , Low, Gavin , Mehta, Shyam, Murad, M. Hassan

Diagnostics | June 24, 2025 | Volume: 15 | Issue: 13 | Pages: 1598

10.3390/diagnostics15131598 | PMID 40647597 Get It

Objectives: To compare thresholds and accuracies of FIB-4, vibration-controlled transient elastography (VCTE), point shear wave elastography (pSWE), 2D shear wave elastography (2D-SWE), and MR elastography (MRE) for detecting hepatic fibrosis in patients with MASLD. Materials and Methods: Systematic searching of MEDLINE, EMBASE, Cochrane Library, Scopus, and the gray literature from inception to March 2024 was performed. Studies evaluating accuracies of FIB-4, VCTE, 2D-SWE, pSWE, and/or MRE for detecting significant (≥F2) and/or advanced (≥F3) hepatic fibrosis in MASLD patients compared to histology were identified. Full-text review and data extraction were performed independently by two reviewers. Multivariate meta-analysis and subgroup analyses were performed using index test and fibrosis grading. Risk of bias was assessed using QUADAS-2. Results: 207 studies with over 80,000 patient investigations were included. FIB-4 1.3 threshold sensitivity was 71% (95% CI 66–75%) for detecting advanced hepatic fibrosis, which improved to 88% (85–91%) using a <0.75 threshold. FIB-4 specificity using a 2.67 threshold was 96% (94–97%). Sensitivities of 88–91% were achieved using thresholds of 3.2 kPa for pSWE, 4.92 kPa for 2D-SWE, 7.18 kPa for VCTE, and 2.32 kPa for MRE. No significant differences were identified for sensitivities in subgroup analysis with thresholds between 7 and 9 kPa. Most imaging-based studies were high risk of bias for the index test. Conclusions: A FIB-4 threshold of <0.75 and modality-dependent thresholds (VCTE < 7 kPa; pSWE <3 kPa; 2D-SWE <5 kPa; and MRE <2.5 kPa) would achieve sensitivities of around 90% when defining low-risk MASLD in population screening. A modified two-tier algorithm aligning with existing Society of Radiologists in Ultrasound guidelines would improve risk stratification accuracies compared to existing guidelines by European and American liver societies.
Survey Study on the Experience, Practice Patterns, and Preferences of the Fellows of the Society of Radiologists in Ultrasound for Evaluation and Management of Gallbladder Polyps Detected With Ultrasound
Middleton, William D., Fung, Christopher, Dahiya, Nirvikar, Szpakowski, Jean-Luc, Corwin, Michael T., Fetzer, David T., Gabriel, Helena, Rodgers, Shuchi K., Tublin, Mitchell E., Walsh, Andrew J., Kamaya, Aya, Fetzer, David T. , Middleton, William D., Fung, Christopher, Dahiya, Nirvikar, Szpakowski, Jean-Luc, Corwin, Michael T., Gabriel, Helena, Rodgers, Shuchi K., TUBLIN, MITCHELL E. , Walsh, Andrew J., Kamaya, Aya

Ultrasound Quarterly | February 28, 2022 | Volume: 38 | Issue: 2 | Pages: 96-102

10.1097/ruq.0000000000000597 | PMID 35221317 Get It

Abstract Gallbladder polyps (GPs) are a common incidental finding on ultrasound; however, important differences in recommended management exist among professional society guidelines. An electronic survey was sent to 189 fellows of the Society of Radiologists in Ultrasound. Main outcomes included preferences and current practice patterns for evaluation, management, and surveillance of GPs as well as personal lifetime experience with gallbladder sonography and GPs. A total of 64 subjects (34%) with experience in gallbladder sonography completed the study. The estimated combined total number of gallbladder scans seen by the responders was 3,071,880. None of fellows had ever seen a pedunculated GP <1 cm detected on ultrasound that was proven to be malignant at the time of detection or during subsequent follow-up. All of the fellows used size as a feature to stratify recommendations. The median size threshold currently used by Society of Radiologists in Ultrasound fellows for recommending ultrasound follow-up was 6 mm, and their preferred threshold was 7 mm. The median size threshold for recommending surgical consultation was 10 mm, and the preferred threshold was 10 mm. Wall thickening and shape were considered important factors by 76% and 67% of respondents, respectively. Society of Radiologists in Ultrasound fellows tend to provide recommendations most similar to the American College of Radiology and Canadian Association of Radiology guidelines for management of GPs. Many would prefer guidelines that result in fewer recommendations for follow-up and surgical consultation. Despite a substantial combined experience, this survey did not uncover any case of a small GP that was malignant.