Summary Oral ovalbumin administration prevents epicutaneously‐induced egg allergy by suppressing Tfh and B cells and IgE. This prophylactic oral ovalbumin abolishes antigen‐specific IL‐4 and IL‐13 production in skin‐draining lymph nodes.
A96-02 Isoflurane or Propofol for Sedation of Mechanically Ventilated Adults in the ICU: Results of the Inspire ICU Trials
Abstract Introduction Sedation is routinely administered to facilitate comfort and tolerance of life support for critically ill adults dependent on invasive mechanical ventilation. Isoflurane, a widely used anesthetic during surgery, has properties that may also benefit ICU patients requiring continuous sedation. However, efficacy as a sedative and safety in this population is not well established. Methods We conducted two identically designed multicenter randomized trials, INSPIRE ICU1 and INSPIRE ICU2, at hospitals across the US. Ventilator-dependent adults were randomly assigned in a 1.5:1 ratio to receive either inhaled isoflurane or intravenous propofol as the first-line sedative for up to 48 ± 6 hours, targeting a sedation depth between Richmond agitation-sedation scale (RASS) -1 (drowsy) to -4 (responsive only to physical stimuli). Isoflurane was administered via an anesthetic conserving device (Sedaconda ACD-S). In both arms, opioids were permitted at the lowest dose required to achieve freedom from pain. The primary outcome was the percentage of time at target sedation level, assessed as a noninferiority outcome with pre-specified margin of 15%. Secondary outcomes included opioid exposure, wake-up time after end of treatment, time to extubation, and proportion of time with spontaneous breathing effort. Results A total of 470 combined participants were included in the two trials. In each trial, 142 patients were randomly assigned to isoflurane and 93 to propofol. In INSPIRE ICU1, percentage of time within target sedation depth was 77.1 [53.2, 89.9] % with isoflurane and 80.9 [58.2, 96.4] % with propofol (difference -1.5 [-8.9, >99] %; p < 0.01 for noninferiority). In INSPIRE ICU2, percentage of time within target sedation depth was 72.6 [66.4, 78.9] % with isoflurane and 74.5 [67.5, 81.5] % with propofol (difference -1.9 [-9.4, >99] %; p < 0.01 for noninferiority). In both trials, patients assigned to isoflurane received significantly less opioid, measured as fentanyl equivalents, during the treatment period. In INSPIRE ICU2, participants receiving isoflurane were significantly likelier to exhibit spontaneous breathing efforts, but this finding was not replicated in INSPIRE ICU1. There were no significant differences in time to wake-up or time to extubation between groups in either trial. No episodes of malignant hyperthermia or propofol infusion syndrome were reported. Adverse events were comparable in type and frequency between groups. Conclusions In two US multicenter trials, isoflurane was noninferior to propofol for maintaining target sedation depth in adults undergoing invasive ventilation, and was associated with significantly lower opioid exposure. (NCT05327296, NCT05312385) This abstract is funded by: Sedana Medical
Inter-rater Agreement of Richmond Agitation Sedation Scale Assessments in Adult Patients Receiving Mechanical Ventilation in the ICU: A Cross-Sectional Study
IMPORTANCE: Accurate and reliable sedation assessment is crucial to improving patient outcomes in the ICU. OBJECTIVE: To evaluate the inter-rater agreement and reliability of Richmond Agitation Sedation Scale (RASS) assessments between bedside nurses and trained investigators in patients receiving mechanical ventilation in the ICU. DESIGN, SETTING, AND PARTICIPANTS: An assessor triad, comprising an ICU nurse providing direct patient care and two trained investigators, simultaneously performed RASS assessments during 79 encounters with 62 unique patients receiving mechanical ventilation at two ICUs at a tertiary care academic hospital in Colorado. A total of 58 nurses participated in the study. MAIN OUTCOMES AND MEASURES: The inter-rater reliability of RASS assessments was evaluated with the intraclass correlation coefficient (ICC) and weighted kappa (κ), and inter-rater agreement was evaluated with percentage agreement and Bland-Altman analysis. RESULTS: Acute respiratory failure (55%) and altered mental status (21%) were the most common reasons for mechanical ventilation. Most patients were receiving one (interquartile range, 0.5–2) continuous sedative during the assessment. The inter-rater reliability of RASS assessments between the nurses and investigators (ICC, 0.728–0.779; weighted κ, 0.62–0.63) was lower than between the two investigators (ICC, 0.891; weighted κ, 0.80). The assessor triad agreed on the same RASS values in only 35% of observations. The average differences in RASS were greater between the investigators and nurses, ranging from –0.658 to –0.544, compared with 0.114 between the two investigators. Compared with the mean of the two investigators, RASS values recorded by nurses were more likely to be higher (52% of observations), indicating a lighter sedation level. In 16% of observations, at least one assessor commented on uncertainty or ambiguity with the RASS. CONCLUSIONS AND RELEVANCE: The inter-rater reliability of RASS assessments was high. However, we observed variations in the degree of agreement by assessor category. Further studies are necessary to explore how factors such as assessor characteristics, ICU environment, and patient conditions influence the inter-rater agreement of the RASS in contemporary ICU practices.
A world-wide study on delirium assessments and presence of protocols
Abstract Background Delirium is a common complication of older people in hospitals, rehabilitation and long-term facilities. Objective To assess the worldwide use of validated delirium assessment tools and the presence of delirium management protocols. Design Secondary analysis of a worldwide one-day point prevalence study on World Delirium Awareness Day, 15 March 2023. Setting Cross-sectional online survey including hospitals, rehabilitation and long-term facilities. Methods Participating clinicians reported data on delirium, the presence of protocols, delirium assessments, delirium-awareness interventions, non-pharmacological and pharmacological interventions, and ward/unit-specific barriers. Results Data from 44 countries, 1664 wards/units and 36 048 patients were analysed. Validated delirium assessments were used in 66.7% (n = 1110) of wards/units, 18.6% (n = 310) used personal judgement or no assessment, and 10% (n = 166) used other assessment methods. A delirium management protocol was reported in 66.8% (n = 1094) of wards/units. The presence of protocols for delirium management varied across continents, ranging from 21.6% (on 21/97 wards/units) in Africa to 90.4% (235/260) in Australia, similar to the use of validated delirium assessments with 29.6% (29/98) in Africa to 93.5% (116/124) in North America. Wards/units with a delirium management protocol [n = 1094/1664, 66.8%] were more likely to use a validated delirium test than those without a protocol [odds ratio 6.97 (95% confidence interval 5.289–9.185)]. The presence of a delirium protocol increased the chances for valid delirium assessment and, likely, evidence-based interventions. Conclusion Wards/units that reported the presence of delirium management protocols had a higher probability of using validated delirium assessments tools to assess for delirium.