Citations

Mayo Clinic

Clear

4 citation(s) found for "Baker, Colin".

Distinct evolutionary patterns of endemic and emerging parvoviruses and the origin of a new pandemic virus
López-Astacio, Robert A. , Wasik, Brian R. , Lee, Hyunwook , Voorhees, Ian E. H. , Weichert, Wendy S. , Adu, Oluwafemi F. , Truyen, Uwe , Parrish, Colin R. , Truyen, Uwe , Parrish, Colin R , Goodman, Laura B. , Hafenstein, Susan

Proceedings of the National Academy of Sciences | April 14, 2026 | Volume: 123 | Issue: 16 | Pages: No page available

10.1073/pnas.2515274123 | PMID 41980105 Get It

Emergence of epidemic viruses in new hosts threatens both human and other animal populations, and often involves virus evolution to overcome barriers that normally prevent efficient infection and spread in that host. After transfer the separated viruses will evolve in parallel as they spread within the original and new hosts. Here we examine the details of a virus involved in such a host-jumping event, where we define the natural evolution of feline panleukopenia virus (FPV) over 60 y, clarify the origins of the new pandemic canine parvovirus (CPV) that arose in the 1970s, and compare the separate evolution of those viruses over 47 y in cats or dogs. Several live-attenuated FPV vaccine viruses originated from early-1960s isolates or were a recombinant of an early virus, and many sequences in databases proved to be vaccine-derived. The sequences of wild viruses showed that FPV-like strains evolved at less than one-third the rate observed for CPV in dogs, and the higher rate of CPV evolution has been consistent since 1979, when a genetic variant became widespread. The common ancestor of the CPV lineage was related to FPVs from Europe and contained several unique host-adaptive capsid changes associated with canine transferrin receptor type-1 binding. Although the FPV vaccine strains are around 60 y old, little selection for antigenic variation was observed. The distinct evolutionary patterns of these closely related viruses circulating for decades in different hosts emphasize the complex evolution associated with viral epidemic emergence and spread in endemic and new hosts.
Structures and functions of the limited natural polyclonal antibody response to parvovirus infection
Adu, Oluwafemi F. , Lee, Hyunwook , Früh, Simon P. , Schoenle, Marta V., Weichert, Wendy S. , Parrish, Colin R. , Hafenstein, Susan L, Parrish, Colin R , Flyak, Andrew I. , Hafenstein, Susan

Proceedings of the National Academy of Sciences | February 14, 2025 | Volume: 122 | Issue: 8 | Pages: No page available

10.1073/pnas.2423460122 | PMID 39951487 Get It

Host antibody responses are key components in the protection of animals against pathogens, yet the defining properties of viral antigens and induction of B cell responses that result in varied protection are still poorly understood. Parvoviruses are simple molecular structures that display 60 repeated motifs on their capsid surface, and rapidly induce strong antibody responses that protect animals from infection. We recently showed that following canine parvovirus infection of its natural host, the polyclonal response in the sera contained only two or three dominant antibodies that bound two epitopes on the capsid. Here, we characterize key antibodies present in that immune response, identifying their sequences, defining their binding properties on the capsid by cryoelectron microscopic (cryoEM) analysis, and testing their effects on viral infectivity. Two antibodies sharing the same heavy chain bound to the side of the capsid threefold spike (B-site), while another distinct antibody bound close to the threefold axis (A-site). The epitopes of these antibodies overlapped the binding site of the host receptor, the transferrin receptor type-1, but to varying degrees. The antibodies varied widely in their neutralization efficiencies as either immunoglobulins (IgGs) or monomeric antigen-binding fragments (Fabs), which was consistent with their ability to compete for the receptor. The monoclonal antibodies characterized here matched the structures from the cryoEM analysis of polyclonal sera, including those present in a different dog than the monoclonal source. This shows that after infection, a focused response to the viral antigen is produced that protects against infection.
A comparison of carbon ions versus protons for integrated mode ion imaging
Simard, Mikaël , Fullarton, Ryan , Robertson, Daniel , Toltz, Allison, Baker, Colin , Graeff, Christian , Collins‐Fekete, Charles‐Antoine , Robertson, Daniel G, Graeff, Christian , Volz, Lennart , Schuy, Christoph , Baker, Colin, Beddar, Sam

Medical Physics | February 4, 2025 | Volume: 52 | Issue: 5 | Pages: 3097-3106

10.1002/mp.17645 | PMID 39904601 Get It

Abstract Background Incorporating image guidance into ion beam therapy is critical for minimizing beam range uncertainties and realizing the modality's potential. One promising avenue for image guidance is to capture transmission ion radiographs (iRads) before and/or during treatment. iRad image quality is typically maximized using a single‐event imaging system, which involves tracking individual ions, albeit the approach is generally not suited to clinical beam settings. An alternative faster and clinically compatible method is integrated mode imaging, where individual pencil beam data is acquired, rather than single ion data. To evaluate the usefulness of transmission ion imaging for image guidance, it is crucial to evaluate the image quality of integrated mode iRad systems. Purpose We report extensive image quality metrics of integrated mode carbon ion radiographs (cRads) and compare them with proton radiographs (pRads). Methods iRads were obtained at the Marburg Ion Beam Therapy Center using a plastic volumetric scintillator equipped with CCD cameras. The detector captures orthogonal views of the 3D energy deposition in the scintillator from individual pencil beams. Four phantoms were scanned using a field of view and a beam spacing of 1 mm. First, 9 tissue‐substitute inserts were used to evaluate water equivalent thickness (WET) accuracy. Radiographs of those inserts were reconstructed for beam spacings ranging from 1 to 7 mm to evaluate the impact of spacing on quantitative accuracy. For spatial resolution, custom 3D printed line pair (lp) modules ranging from 0.5 to 10 lp/cm were scanned. To evaluate low contrast detectability, a custom 3D printed low contrast module consisting of 20 holes with depths ranging from 1 to 8 mm and diameters from 1 to 10 mm was scanned. iRads of an anthropomorphic head phantom were also obtained. Results Spatial resolution and low contrast detection are systematically improved for cRads compared to pRads. Image resolution was 3.7 lp/cm for cRads and 1.7 lp/cm for pRads in the center of the field of view. Spatial resolution was found to vary with the object's location in the field of view. While pRads could mostly resolve low contrast holes of 10 mm in diameter, cRads could resolve holes of up in 4 mm diameter. WET accuracy is similar for both ion species, with a root mean squared error of approximately 1 mm. WET accuracy was stable (maximum of 0.1 mm increase) across beam spacings, although important under‐sampling artifacts were observed for iRads reconstructed using large beam spacings, especially for cRads. iRads of the anthropomorphic head phantom showed improved apparent contrast using cRads, especially to identify bony structures. Conclusions This work is the first investigation of image quality metrics such as spatial resolution and low contrast detectability for integrated mode cRads, with a full comparison with pRads. Enhanced image quality is obtained with cRads compared to pRads, although pRads still maintain high WET accuracy and deliver image quality within acceptable bounds.
Imaging lung tumor motion using integrated‐mode proton radiography—A phantom study towards tumor tracking in proton radiotherapy
Fullarton, Ryan , Simard, Mikaël , Toltz, Allison, Chung, Savanna, Schuy, Christoph , Robertson, Daniel , Royle, Gary , Baker, Colin , Graeff, Christian , Collins‐Fekete, Charles‐Antoine , Robertson, Daniel G, Graeff, Christian , Volz, Lennart , Chung, Savanna, Beddar, Sam , Baker, Colin

Medical Physics | November 12, 2024 | Volume: 52 | Issue: 2 | Pages: 1146-1158

10.1002/mp.17508 | PMID 39530503 Get It

AbstractBackgroundMotion of lung tumors during radiotherapy leads to decreased accuracy of the delivered dose distribution. This is especially true for proton radiotherapy due to the finite range of the proton beam. Methods for mitigating motion rely on knowing the position of the tumor during treatment.PurposeProton radiography uses the treatment beam, at an energy high enough to traverse the patient, to produce a radiograph. This work shows the first results of using an integrated‐mode proton radiography system to track the position of moving objects in an experimental phantom study; demonstrating the potential of using this method for measuring tumor motion.MethodsProton radiographs of an anthropomorphic lung phantom, with a motor‐driven tumor insert, were acquired approximately every 1 s, using tumor inserts of 10, 20, and 30 mm undergoing a known periodic motion. The proton radiography system used a monolithic scintillator block and digital cameras to capture the residual range of each pencil beam passing through the phantom. These ranges were then used to produce a water equivalent thickness map of the phantom. The centroid of the tumor insert in the radiographs was used to determine its position. This measured position was then compared to the known motion of the phantom to determine the accuracy.ResultsSubmillimeter accuracy on the measurement of the tumor insert was achieved when using a 30 mm tumor insert with a period of 24 s and was found to be improved for decreasing motion amplitudes with a mean absolute error (MAE) of 1.0, 0.9, and 0.7 mm for 20, 15, and 10 mm respectively. Using smaller tumor inserts reduced the accuracy with a MAE of 1.8 and 1.9 mm for a 20 and 10 mm insert respectively undergoing a periodic motion with an amplitude of 20 mm and a period of 24 s. Using a shorter period resulted in significant motion artifacts reducing the accuracy to a MAE of 2.2 mm for a 12 s period and 3.1 mm for a 6 s period for the 30 mm insert with an amplitude of 20 mm.ConclusionsThis work demonstrates that the position of a lung tumor insert in a realistic anthropomorphic phantom can be measured with high accuracy using proton radiographs. Results show that the accuracy of the position measurement is the highest for slower tumor motions due to a reduction in motion artifacts. This indicates that the primary obstacle to accurate measurement is the speed of the radiograph acquisition. Although the slower tumor motions used in this study are not clinically realistic, this work demonstrates the potential for using proton radiography for measuring tumor motion with an increased scanning speed that results in a decreased acquisition time.