Background: Sinonasal undifferentiated carcinoma (SNUC) is an extremely rare, high-grade, and aggressive tumor of the sinonasal tract. Due to the rarity of this malignancy, current treatment guidelines are based on small and often/mainly single-center retrospective datasets. In the absence of a universally accepted standard of care for SNUC, treatment approaches vary across countries and institutions, reflecting real-world clinical practice. The primary aim of this study was to describe real-world treatment and outcomes for patients with confirmed SNUC. Methods: This was an international, multi-center, retrospective, observational cohort study that pooled patients into the largest SNUC dataset to date. Fifteen centers were enrolled to contribute data, including seven from Europe, four from the United States, three from the United Kingdom, and one from Canada. In the absence of a universally accepted standard of care for SNUC, treatment approaches varied across countries and institutions, reflecting real-world clinical practice. Patients included were those with histologically confirmed SNUC who were treated between 1997 and 2021. Results: This study yielded 485 patients treated for SNUC. The median age at diagnosis was 55.6 years (IQR: 44.5–67.6), and 63.7% were male. Most cases presented at advanced stages, with 70.8% as T4a or T4b. Overall survival (OS) outcomes were available for 412 patients, with a median follow-up of 26.0 months. The 5- and 10-year OS were 47.2% (95% CI: 40.8–53.3%) and 39.6% (95% CI: 32.5–46.6%), respectively. Advanced age, dichotomized T-stage (T4a/b vs. T1–3), M-stage, and orbital involvement were significant poor prognostic factors on univariable analysis (p’s < 0.01). On multivariable analysis, orbital involvement (HR: 2.73, 95% CI: 1.42–5.27, p = 0.003) and distance metastasis stage (HR: 3.00, 95% CI: 1.25–7.21, p = 0.014) were both independently associated with worse OS. Conclusions: This observational study presents the largest multi-center cohort analysis of SNUC to date, providing new insights into prognostic factors for a rare cancer treated at global centers of excellence. Orbital involvement and the presence of metastases are candidate independent risk factors associated with poorer OS.
Imaging lung tumor motion using integrated‐mode proton radiography—A phantom study towards tumor tracking in proton radiotherapy
AbstractBackgroundMotion of lung tumors during radiotherapy leads to decreased accuracy of the delivered dose distribution. This is especially true for proton radiotherapy due to the finite range of the proton beam. Methods for mitigating motion rely on knowing the position of the tumor during treatment.PurposeProton radiography uses the treatment beam, at an energy high enough to traverse the patient, to produce a radiograph. This work shows the first results of using an integrated‐mode proton radiography system to track the position of moving objects in an experimental phantom study; demonstrating the potential of using this method for measuring tumor motion.MethodsProton radiographs of an anthropomorphic lung phantom, with a motor‐driven tumor insert, were acquired approximately every 1 s, using tumor inserts of 10, 20, and 30 mm undergoing a known periodic motion. The proton radiography system used a monolithic scintillator block and digital cameras to capture the residual range of each pencil beam passing through the phantom. These ranges were then used to produce a water equivalent thickness map of the phantom. The centroid of the tumor insert in the radiographs was used to determine its position. This measured position was then compared to the known motion of the phantom to determine the accuracy.ResultsSubmillimeter accuracy on the measurement of the tumor insert was achieved when using a 30 mm tumor insert with a period of 24 s and was found to be improved for decreasing motion amplitudes with a mean absolute error (MAE) of 1.0, 0.9, and 0.7 mm for 20, 15, and 10 mm respectively. Using smaller tumor inserts reduced the accuracy with a MAE of 1.8 and 1.9 mm for a 20 and 10 mm insert respectively undergoing a periodic motion with an amplitude of 20 mm and a period of 24 s. Using a shorter period resulted in significant motion artifacts reducing the accuracy to a MAE of 2.2 mm for a 12 s period and 3.1 mm for a 6 s period for the 30 mm insert with an amplitude of 20 mm.ConclusionsThis work demonstrates that the position of a lung tumor insert in a realistic anthropomorphic phantom can be measured with high accuracy using proton radiographs. Results show that the accuracy of the position measurement is the highest for slower tumor motions due to a reduction in motion artifacts. This indicates that the primary obstacle to accurate measurement is the speed of the radiograph acquisition. Although the slower tumor motions used in this study are not clinically realistic, this work demonstrates the potential for using proton radiography for measuring tumor motion with an increased scanning speed that results in a decreased acquisition time.
Integrated-mode proton radiography with 2D lateral projections
Abstract Integrated-mode proton radiography leading to water equivalent thickness (WET) maps is an avenue of interest for motion management, patient positioning, and in vivo range verification. Radiographs can be obtained using a pencil beam scanning setup with a large 3D monolithic scintillator coupled with optical cameras. Established reconstruction methods either (1) involve a camera at the distal end of the scintillator, or (2) use a lateral view camera as a range telescope. Both approaches lead to limited image quality. The purpose of this work is to propose a third, novel reconstruction framework that exploits the 2D information provided by two lateral view cameras, to improve image quality achievable using lateral views. The three methods are first compared in a simulated Geant4 Monte Carlo framework using an extended cardiac torso (XCAT) phantom and a slanted edge. The proposed method with 2D lateral views is also compared with the range telescope approach using experimental data acquired with a plastic volumetric scintillator. Scanned phantoms include a Las Vegas (contrast), 9 tissue-substitute inserts (WET accuracy), and a paediatric head phantom. Resolution increases from 0.24 (distal) to 0.33 lp mm −1 (proposed method) on the simulated slanted edge phantom, and the mean absolute error on WET maps of the XCAT phantom is reduced from 3.4 to 2.7 mm with the same methods. Experimental data from the proposed 2D lateral views indicate a 36% increase in contrast relative to the range telescope method. High WET accuracy is obtained, with a mean absolute error of 0.4 mm over 9 inserts. Results are presented for various pencil beam spacing ranging from 2 to 6 mm. This work illustrates that high quality proton radiographs can be obtained with clinical beam settings and the proposed reconstruction framework with 2D lateral views, with potential applications in adaptive proton therapy.