Citations

Mayo Clinic

Showing 10 of 108474 citations.

Relation of Increase in Muscle Mass to Performance of Hypertrophied Right Ventricle in the Dog
Geha, Alexander S., Duffy, John P., Swan, H.J.C.

Circulation Research | June 12, 2012 | Volume: 19 | Issue: 2 | Pages: 255-259

10.1161/01.res.19.2.255 | PMID 4223788 Get It

Right ventricular hypertrophy was produced by chronic constriction (banding) of the pulmonary artery in the dog. Right ventricular muscle mass increased by 40% in 6 to 12 weeks after banding. Maximal work performance of this ventricle also increased; at 12 weeks the mean was 175% more than that of the normal right ventricle. It was concluded that, per unit of gross myocardial mass, the work performance of the hypertrophied right ventricle of the dog was no less than that of the normal right ventricle.
Atrial Contribution to Stroke Volume in Dogs with Chronic Heart Block
Snyder, J. H., Kitchin, A H, Zitnik, Ralph S., Donald, David E., Wood, Earl H., Bender, Franz

Circulation Research | June 12, 2012 | Volume: 19 | Issue: 1 | Pages: 33-41

10.1161/01.res.19.1.33 Get It

In dogs studied without thoracotomy, under morphine-pentobarbital anesthesia and with an average heart rate of 71 beats/minute, atrial systole contributes to ventricular function to a small but significant degree. Stroke volume increased by 7 to 8% when atrial systole was timed to occur 0.1 second prior to closure of the atrioventricular valves, and decreased a similar magnitude when the contribution of atrial systole to ventricular filling was rendered ineffective by the use of an A-V delay of zero so that atrial emptying into the ventricles was prevented by the closed A-V valves. Increases or decreases in right atrial pressure of several centimeters of water induced by infusion of 6% dextran and by hemorrhage, respectively, were not associated with demonstrably significant alterations in these effects.
Myofibrillar Adenosine Triphosphatase Activity of Human Heart Tissue in Congestive Failure: Effects of Ouabain and Calcium
Brown, Arnold L., Gordon, Michael Solomon

Circulation Research | June 12, 2012 | Volume: 18 | Issue: 5 | Pages: 534-542

10.1161/01.res.18.5.534 | PMID 4223012 Get It

Ouabain had no effect on myofibrillar adenosine triphosphatase (ATPase) activity in normal, hypertrophic, and failing hearts with concentrations of calcium chloride varying from 0 to 5.0 mM. The quantitative effects of CaCl 2 on myofibrillar ATPase were the same in all groups studied. At necropsy it was found that myofibrillar ATPase activity of heart tissue from patients with clinical and pathologic diagnoses of failure from left ventricular volume and pressure overload was significantly lower than that of normal controls. The ATPase activity in patients with failure due to right ventricular volume and pressure overload was not significantly lower than that in normal controls. There was no difference in myofibrillar ATPase activity between normal left and normal right and between failing left and failing right ventricles. The difference demonstrated at necropsy between normal and failing hearts was not a function of age or of hypertrophy per se. Myofibrillar ATPase activity of hypertrophic nonfailing surgical pulmonary infundibular tissue was the same as that of normal postmortem ventricles. The ATPase activity of failing surgical papillary muscle in a small number of experiments was in the range of that found in failing postmortem ventricles.
Applications of the Lagged Normal Density Curve as a Model for Arterial Dilution Curves
Bassingthwaighte, James B. , Ackerman, Francis H., Wood, Earl H.

Circulation Research | June 12, 2012 | Volume: 18 | Issue: 4 | Pages: 398-415

10.1161/01.res.18.4.398 | PMID 4952948 Get It

1. Indicator dilution curves (concentration versus time) were recorded from the femoral and dorsalis pedis arteries of normal men after injections of indocyanine green into the superior vena cava or thoracic aorta. A four-parameter mathematical model, the lagged normal density curve, adequately described the form of the portion of these curves representing indicator passing by the sampling site for the first time. 2. The curves were observed to be of constant shape, the spread of the curve being approximately linearly related to the mean transit time t. The spread was dependent on the injection site; dispersion was shown to be greatest in the central circulation, less in the aorta, and still less in the arteries of the leg. For the latter segment, the mean transit time t. The spread was dependent 0.3 t, the square root of the variance was 0.18 t, and the parameters of the lagged normal density curve, σ and τ, were 0.09 t and 0.16 t, respectively. 3. The linear relationships between parameters of the recorded curves and the mean transit times indicate that the effect of rate of flow, over a range from resting values to four to six times above resting values, has almost no influence on the dispersion. This suggests that the flow characteristics are essentially unchanged over this range. Such linear relationships always occur with laminar flow but cannot prove its existence because turbulent flow can also produce this result. The similarity of the linear relationships at low flow rates to those at high flow rates, where turbulence almost certainly is present, suggests that arterial flow is usually turbulent. Turbulence may be expected at relatively low flow rates in nonhomogeneous fluids driven by a pulsatile head of pressure through elastic, branched, tapering, curved tubes.
Human Cardiac Myosin: Electron Microscopic Observations
Carney, J. Aidan, Brown, Arnold L.

Circulation Research | June 12, 2012 | Volume: 17 | Issue: 4 | Pages: 336-339

10.1161/01.res.17.4.336 | PMID 5834295 Get It

Solutions of human cardiac myosin contain macromolecules which were visualized in the electron microscope by the shadow-casting technic. The dominant particle was observed to be rod-shaped, to have a globular expansion at one end, and to have a mean length of about 1500 Å. The molecule of human cardiac myosin was found to be morphologically similar to myosin molecules from canine cardiac muscle and rabbit skeletal muscle.
Circulatory Response to Release of Chronic Pulmonary Artery Constriction
Tobin, John R., Rastelli, G.C., Blundell, Peter, Swan, H.J.C.

Circulation Research | June 12, 2012 | Volume: 17 | Issue: 3 | Pages: 248-258

10.1161/01.res.17.3.248 | PMID 14338697 Get It

The imposition of a chronic work load (pulmonary artery constriction) on the right ventricle increases ventricular muscle mass. This is associated with increased ventricular stroke work when the animal is standing awake, during infusions of norepinephrine, and under conditions of exercise (running on a horizontal treadmill). Studies two weeks after release of chronic pulmonary artery constriction reveal stroke volume and cardiac output are increased during standing at rest, during norepinephrine infusion, and during exercise. Studies eight weeks after removal of pulmonary artery bands show that stroke volume and cardiac output are approaching the normal range. Right ventricular hypertrophy and right ventricular stroke work decline progressively and apparently in parallel in the weeks following release of chronic pulmonary artery constriction. The stroke work capacity of the ventricle seems related to the presence of right ventricular hypertrophy. With a reduction in outflow tract resistance, the stroke volume for a given set of circumstances is markedly increased. From this standpoint, the work capacity of the right ventricle may be taken as a determinant of stroke volume and cardiac output. Decrease of systemic vascular resistance and relative insensitivity of systemic vasoreceptors to norepinephrine were observed after the release of chronic pulmonary artery constriction. These phenomena have roles in the production of the observed hyperdynamic circulatory state, but their contributions to its genesis are secondary to the major role of the hypertrophied right ventricle.
Continuously Recorded Changes of Thoracic Aortic Blood Flow in Man in Response to Leg Exercise in Supine Position
Zitnik, Ralph S., RODICH, FILMORE S., Marshall, Hiram W., Wood, Earl H.

Circulation Research | June 12, 2012 | Volume: 17 | Issue: 2 | Pages: 97-105

10.1161/01.res.17.2.97 | PMID 14334830 Get It

The constant-rate-injection, indicator-dilution technic was used to determine thoracic aortic blood flow before, during, and after five minutes of single-leg exercise (bicycle ergometer) in five healthy male subjects in the supine position. Resistance to blood flow in the lower body and mean aortic pressure decreased immediately at the onset of exercise, at the same time that thoracic aortic blood flow and heart rate increased. There was a further slow rise of heart rate, mean aortic pressure, and thoracic aortic blood flow along with a decrease of lower body resistance until fairly stable levels were reached after five minutes of exercise. After five and ten minutes' rest all values tended to return toward those observed in the control state. These data are consistent with the concept that baroreceptor activity may play an important part in the early cardiovascular responses to exercise in man. Most of the cardiovascular response to this exercise occurred in the first 30 seconds.
Induced Pressure Gradients Across Infundibular Zone of Right Ventricle in Normal Dogs
Tobin, John R., Blundell, Peter, Goodrich, Ralph G., Swan, H.J.C.

Circulation Research | June 12, 2012 | Volume: 16 | Issue: 2 | Pages: 162-173

10.1161/01.res.16.2.162 | PMID 14259356 Get It

In these experiments we have demonstrated that: 1. Right ventricular outflow-tract pressure gradients of significance can be induced in normal dogs by a sympathomimetic amine which increases the rate and force of ventricular contraction. 2. Such outflow-tract pressure gradients are magnified by the addition of other inotropic drugs, such as acetyl strophanthidin and calcium chloride. 3. These outflow-tract pressure gradients are not the result of an increase in the volume and rate of blood flow but are due to forceful contraction of the infundibulum.
Comparison of Dilution Technics Using Aortic Injection with Upstream Sampling for Assessment of Aortic Regurgitation
Armelin, E, Donald, David E., Wood, Earl H.

Circulation Research | June 12, 2012 | Volume: 15 | Issue: 4 | Pages: 287-300

10.1161/01.res.15.4.287 | PMID 14220885 Get It

The distances between the aortic valve and sites in the aorta from which no retrograde flow of injected indicator could be detected in the left ventricle were determined, without thoracotomy, in two normal dogs and in ten dogs with chronic experimental aortic regurgitation. It was found that these distances attained maximal values when the aortic injections were timed to occur just at the end of systole or onset of diastole. Distances downstream from the origin of the left subclavian artery from which no retrograde flow occurred to this vessel were determined similarly in these same animals and, in confirmation of Warner and Toronto, similar relationships to the timing of the injections were obtained. These distances down the aorta, designated as "disappearance distances", were converted to "disappearance volumes" by measuring the diameters of the silhouette of successive aortic segments from aortograms made after contrast medium was injected into the left ventricle of these animals. The regurgitant flow through the aortic valve per heartbeat was estimated on the basis of the amount of immediately appearing indicator detected in the left ventricle following injection of indicator approximately 1 cm downstream from the aortic valve. Correlation coefficients of 0.88 and 0.77 were obtained between these stroke-regurgitation values and the disappearance volumes from the aortic valve and subclavian artery, respectively. The standard errors of the estimate of the regurgitant flow per beat from these regression equations were ± 2.7 and ± 2.9 ml/beat, respectively. The correlation coefficients between stroke-regurgitation values and the disappearance distances from the valve and subclavian artery were 0.83 and 0.81, respectively, and the respective standard errors of the estimate of stroke regurgitation from these regression equations were ± 3.2 and ± 3.3 ml/beat. It is concluded that determination of the maximal distances downstream in the aorta of sites from which retrograde flow of injected indicator can be detected in the left ventricle or subclavian artery is a valid method for estimating the severity of experimental aortic regurgitation in dogs. Since determinations of the disappearance distance from the aortic valve can be carried out readily in conjunction with measurement of the left ventricular regurgitation fraction, it is suggested that advantage be taken of the increase in reliability which accrues from the combined use of these two independent methods for the estimation of the degree of aortic regurgitation.
Assessment of an Indicator-Dilution Technic for Quantitating Aortic Regurgitation by Electromagnetic Flowmeter
MALOOLY, DONALD A., Donald, David E., Marshall, Hiram W., Wood, Earl H.

Circulation Research | June 12, 2012 | Volume: 12 | Issue: 5 | Pages: 487-507

10.1161/01.res.12.5.487 Get It

The square-wave electromagnetic flowmeter was used to assess the upstream sampling dye-dilution technic for quantitating aortic regurgitation by simultaneous determinations of the regurgitant fraction by flowmeter, as given by the ratio of regurgitant volume to total stroke volume (RV/TSV) and the identical ratio of regurgitant flow to total forward flow (Q R /Q F ), and the regurgitant fraction by dye curve, as given by the ratio of the areas of the immediately appearing portion of the left ventricular curve to the area of the femoral artery dye curve (LV A /FA A ), after injection of indicator approximately 1 cm downstream to the aortic valve. A good correlation (r = 0.91) was found between these two independent methods which can be represented by the regression equation Q R /Q F = 0.82 (LV A /FA A ). This correlation indicates that the concept that the regurgitant fraction of indicator (LV A /FA A ) is proportionate to the regurgitant fraction of blood (RV/TSV) is valid. The observed systematic difference between flow-meter and dye-curve regurgitant fractions may be due to the fact that time-average rather than volume-average concentrations of the indicator are obtained by sampling of blood through eatheters. Two different and independent calibration technics were used to establish a calibration factor for converting recorded flowmeter deflections to volumetric units for measurement of rates and volumes of blood flow in the ascending aorta. The first technic involved simultaneous recording of dye-dilution curves and velocity pulses in the ascending aorta by the flowmeter before the production of aortic regurgitation. The second involved bidirectional perfusion of the isolated aorta at known rates of blood flow with simultaneous flowmeter recordings at the termination of each experiment. The data obtained validated the use of the flowmeter for measurements of total stroke volume and regurgitant stroke volume. The close correspondence between flowmeter recordings of the regurgitant flow and hydraulic estimates of regurgitant flow, based on the size of the defect in the aortic valve measured at necropsy and continuous records of the pressure gradient across the valve, also lent strong support to the validity of these measurements. The relationship Q R = Q S (Q R /Q F )/(1 - Q R /Q F ) can be used to estimate regurgitant flow from values of the regurgitant fraction (Q R /Q F ) and the systemic flow (Q S ). The mathematical relationship of the regurgitant fraction to regurgitant flow, determined by the dilution-curve technic, plus the variability obtained between simultaneous flowmeter and dilution-curve estimates of regurgitation, indicate that the error in the estimation of regurgitant flow by the dye-dilution technic is least for small-to-moderate degrees of regurgitation and increases progressively with the severe degrees of regurgitation associated with regurgitant fractions of greater than 0.6. On the basis of 231 simultaneous determinations by the indicator-dilution and flowmeter technics carried out in nine dogs, and assuming that the flowmeter values were uniformly correct, it was estimated that the standard deviation of the errors in measurement of regurgitant flow by the upstream sampling dye-dilution method in these experiments was 0.15 L per minute for regurgitant fractions below 0.6. and that this variability increased so that the standard deviation was 1.3 L per minute at regurgitant fraction levels of 0.9 to 1.0. The results of determinations carried out over a range of heart rates from 39 to 216 beats per minute indicate that the indicator-dilution method is applicable over a wide range of heart rates. The observed changes in aortic regurgitation with variation in heart rate correlated closely with the changes estimated by hydraulic equations based on the hydrodynamics of steady flow through an orifice. The increase in regurgitant stroke volume with increased duration of diastole at slow heart rates was disproportionately greater than the increase in total stroke volume, so that the effective forward (systemic) flow fell to extremely low levels at slow heart rates, particularly in dogs with large defects in the aortic valve. The applicability of the upstream sampling indicator-dilution technic to the detection and estimation of the severity of aortic regurgitation in human beings merits further study.