Citations

Mayo Clinic

Clear

347 citation(s) found for "Noseworthy, PA".

Predictive Value of Artificial Intelligence‐Enabled Electrocardiography in Patients With Takotsubo Cardiomyopathy
Kanaji, Yoshihisa , Ӧzcan, Ilke , Tryon, David, Ahmad, Ali , Sara, Jaskanwal Deep Singh , Lewis, B , Friedman, Paul A. , Noseworthy, Peter A. , Lerman, Lilach O. , Kakuta, Tsunekazu , Ozcan, Ilke , Tryon, David N, Lewis, Bradley R , Friedman, Paul A , Attia, Zachi I , Lerman, Amir , Noseworthy, Peter A , Kanaji, Yoshihisa , Sara, Jaskanwal D S , Attia, Zachi I. , Lerman, Amir

Journal of the American Heart Association | February 23, 2024 | Volume: 13 | Issue: 5 | Pages: No page available

10.1161/jaha.123.031859 | PMID 38390798 Get It

Background Recent studies have indicated high rates of future major adverse cardiovascular events in patients with Takotsubo cardiomyopathy (TC), but there is no well‐established tool for risk stratification. This study sought to evaluate the prognostic value of several artificial intelligence‐augmented ECG (AI‐ECG) algorithms in patients with TC. Methods and Results This study examined consecutive patients in the prospective and observational Mayo Clinic Takotsubo syndrome registry. Several previously validated AI‐ECG algorithms were used for the estimation of ECG‐ age, probability of low ejection fraction, and probability of atrial fibrillation. Multivariable models were constructed to evaluate the association of AI‐ECG and other clinical characteristics with major adverse cardiac events, defined as cardiovascular death, recurrence of TC, nonfatal myocardial infarction, hospitalization for congestive heart failure, and stroke. In the final analysis, 305 patients with TC were studied over a median follow‐up of 4.8 years. Patients with future major adverse cardiac events were more likely to be older, have a history of hypertension, congestive heart failure, worse renal function, as well as high‐risk AI‐ECG findings compared with those without. Multivariable Cox proportional hazards analysis indicated that the presence of 2 or 3 high‐risk findings detected by AI‐ECG remained a significant predictor of major adverse cardiac events in patients with TC after adjustment by conventional risk factors (hazard ratio, 4.419 [95% CI, 1.833–10.66], P =0.001). Conclusions The combined use of AI‐ECG algorithms derived from a single 12‐lead ECG might detect subtle underlying patterns associated with worse outcomes in patients with TC. This approach might be beneficial for stratifying high‐risk patients with TC.
Abstract WP287: AI-ECG Algorithm Outperforms CHA2DS2-VASc in Prediction of Occult Atrial Fibrillation Detection on Prolonged Cardiac Monitoring Following Cerebral Infarction
Holmes, C., Ahmed, Ahmed , Mangold, Kathryn, Graff‐Radford, Jonathan , English, Stephen , Ahmed, Ahmed K , Noseworthy, Peter A. , Rabinstein, Alejandro A.

Stroke | February 1, 2024 | Volume: 55 | Issue: Suppl_1 | Pages: No page available

10.1161/str.55.suppl_1.wp287 Get It

Introduction: Patients diagnosed with ischemic stroke routinely undergo prolonged cardiac telemetry (PCT) to evaluate for occult atrial fibrillation (AF), but this approach is limited by high cost and low yield. Clinical scores including CHA2DS2-VASc and CHARGE-AF can risk stratify patients but lack desired accuracy. Therefore, we aimed to evaluate an artificial intelligence (AI)-enabled ECG algorithm to predict AF detected by PCT after index stroke. Methods: This retrospective study included all adult patients with ischemic stroke evaluated at Mayo Clinic with baseline electrocardiogram (ECG) and PCT between 2018-2020. We recorded demographics, CHA2DS2-VASc score, CHARGE-AF score, stroke etiology, duration of PCT, and if PCT detected AF. ECGs were analyzed using the AI-ECG algorithm to determine AF likelihood. Stroke etiology was adjudicated using TOAST and embolic stroke of undetermined source (ESUS) definitions. The ability of the AI-ECG algorithm, CHA2DS2-VASc, and CHARGE-AF to predict AF detected by PCT was assessed via receiver operating characteristics analysis, calculating the area under curve (AUC) (c-statistic). Sensitivity and specificity analyses were performed for each tool using optimal cutoffs (using maximum Youden indices). Results: 863 patients were included; median age was 69 years, 496 (57.5%) were male, and 561 (65%) patients were categorized as ESUS. PCT detected AF in 85 (9.8%) patients. Median duration of cardiac telemetry was 30 (IQR 25-30) days. Sensitivity and specificity analyses are outlined in Table 1. The AI-ECG algorithm outperformed the CHA2DS2-VASc score (AUC 0.690 vs. 0.597, p=0.013), but was similar to the CHARGE-AF score (AUC 0.690 vs 0.651, p=0.233). Conclusions: Our AI-ECG algorithm demonstrated improved ability to predict AF detection on PCT after index stroke when compared to the CHA2DS2-VASc score, but was similar in performance to the CHARGE-AF score. All three methods had suboptimal accuracy.
Abstract 19083: AI-Enabled ECG Detection of Atrial and Ventricular Septal Defects in Pediatric Patients
Greason, Grace , O’Sullivan, Donnchadh , Anjewierden, Scott , Lopez‐Jimenez, Francisco, Friedman, Paul A. , Anderson, Jason, Kashou, Anthony H. , Eidem, Benjamin W., Johnson, Jonathan N. , Madhavan, Malini , Attia, Zachi I. , López-Jiménez, Francisco , Noseworthy, Peter A. , Anderson, Jason, Niaz, Talha

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.19083 Get It

Background: Atrial septal defects (ASD) and ventricular septal defects (VSD) are among the most common forms of congenital heart disease (CHD). Early detection and intervention for these defects are crucial to prevent complications. Given advancements in AI technology, the development of AI-enabled ECG models for detecting these defects is of significant interest. Aims: This study aimed to create AI models using pediatric ECG data for the detection of ASD, VSD, and a combined model detecting either ASD or VSD. Methods: We analyzed a dataset of 7,795 pediatric patients from Mayo Clinic who had undergone echocardiography between 2002 and 2022, with corresponding 10-second, 12-lead surface ECGs taken within 14 days of echocardiography. This dataset included 259 patients with ASDs and 139 patients with VSDs (single or multiple). The control group was comprised of 7,397 patients without significant or complex CHD. For cases and controls, we included patients with all forms of electrocardiographic abnormalities and those with valvular lesions who had less than moderate stenosis or regurgitation. The dataset was divided into training, validation, and testing subsets to develop convolutional neural network (CNN) models for ASD, VSD, and either ASD or VSD detection. Results: Our ASD and VSD detection models achieved test AUCs of 0.82 (95% CI 0.76, 0.88) and 0.80 (95% CI 0.70, 0.90), respectively. Meanwhile, a combined model that detected either ASD or VSD demonstrated a test AUC of 0.81 (95% CI, 0.76, 0.86), sensitivity of 0.73, specificity of 0.76, PPV of 0.14, and NPV of 0.98 (Figure 1). Conclusions: AI-enabled ECG models demonstrate promising performance in detecting ASD and VSD in pediatric patients. A combined model that detects either ASD or VSD also shows robust results. Future research should focus on multi-center validation of these models, refining their diagnostic capacities, and investigating their potential for early intervention in CHDs.
Abstract 18819: Detection of Systolic Dysfunction in Pediatric Patients Using an Artificial Intelligence-Enabled Electrocardiogram
Anjewierden, Scott , O’Sullivan, Donnchadh , Greason, Grace , Friedman, Paul A. , Anderson, Jason, Kashou, Anthony H. , Eidem, Benjamin W., Johnson, Jonathan N. , Madhavan, Malini , Attia, Zachi I. , López-Jiménez, Francisco , Noseworthy, Peter A. , Anderson, Jason, Niaz, Talha

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.18819 Get It

Introduction: Left and right ventricular systolic dysfunction (LVSD and RVSD respectively) contribute to considerable pediatric morbidity. Both LVSD and RVSD can occur in children before symptom onset, emphasizing the need for early detection. Existing deep-learning algorithms can identify LVSD in adults using 12-lead ECG; however, their efficacy in children is uncertain. Aims: We aimed to create a deep-learning model for LVSD and RVSD detection in pediatric patients using an AI-enabled ECG and compare novel pediatric models to a previously validated adult LVSD model. Methods: We identified 10,214 pediatric patients at the Mayo Clinic with a transthoracic echocardiogram (TTE) and a 10-second, 12-lead surface ECG within 14 days of TTE, performed from 2002 -2022. Our cohort comprised the first TTE-ECG pair from each patient, totaling 138 with EF ≤ 35%, 312 with EF ≤ 50%, 482 with RVSD, and 9,567 without any LVSD or RVSD. The cohort was split into training, validation, and testing datasets to develop neural networks for systolic dysfunction detection. Results: The cohort was 52.3% male, with an average age of 10.3 years. Novel models generated in the pediatric cohort demonstrated excellent performance in systolic dysfunction detection (Figure 1). Pediatric models for EF ≤ 35% and EF ≤ 50% achieved test AUCs of 0.92 (95% CI 0.89, 0.95) and 0.89 (95% CI 0.85, 0.94) respectively. The RVSD model reached a test AUC of 0.91 (95% CI 0.88, 0.94). A combined model for EF ≤ 35% or RVSD exhibited a test AUC of 0.90 (95% CI 0.87, 0.93), sensitivity 0.88, specificity 0.82, PPV 0.20, and NPV 0.95. A combined model for EF ≤ 50% or RVSD exhibited a test AUC of 0.88 (95% CI 0.85, 0.91). The previously validated adult data-derived model achieved an AUC of 0.86 (95% CI 0.83, 0.89) for EF ≤ 50% in children. Conclusions: AI-enabled ECGs demonstrate efficient detection of both LVSD and RVSD in pediatric patients. Future multi-site validation is needed to further establish the reliability of these models.
Abstract 18713: The Impact of ECG-AI Design Choices on Clinical Utility: A Deep Dive Into Left Ventricular Hypertrophy, Hypertrophic Cardiomyopathy, and Cardiac Amyloidosis
Asfahan, Shahir , Anto, Ausath, Verma, Shiva, Friedman, Paul A. , Barve, Rakesh , Siontis, Konstantinos C. , Anto, Ausath G., Gupta, Yash, Noseworthy, Peter A. , Attia, Zachi I. , López-Jiménez, Francisco , Awasthi, Samir

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.18713 Get It

Introduction: Artificial intelligence applied to electrocardiograms (ECG-AI) enables early and efficient detection of cardiovascular disease. The technical and clinical impact of different approaches to designing ECG-AI remains under-explored. We consider left ventricular hypertrophy (LVH) and examine the impact of disease-specific labeling of minority etiologies of left ventricular wall thickening- hypertrophic cardiomyopathy (HCM) and cardiac amyloidosis (CA) - on ECG-AI performance. Hypothesis: ECG-AI designed to detect HCM or CA outperforms ECG-AI broadly trained to identify LVH due to differences in attention to key ECG features associated with HCM or CA. Methods: Independent neural networks were trained to identify HCM, CA, and LVH. HCM and CA patients were identified using the full depth of EHR data and validated via clinician adjudication (N = 3,025 and 4,251 patients, respectively). Moderate and severe LVH patients (N = 98,144) were identified using echocardiogram results and international LVH criteria. We compared the ability of disease-specific ECG-AI vs. LVH ECG-AI to detect HCM (or CA) by examining model performance within each of the three test sets. Results: 52.6% of HCM patients and 49.5% of CA patients met LVH criteria. Within the HCM test set, the AUROC, sensitivity, specificity, and positive predictive value (PPV) of the HCM ECG-AI were 0.94, 0.88, 0.85, and 60%, respectively, whereas the same for LVH ECG-AI were 0.83, 0.83, 0.64, and 37%. Within the CA test set, CA ECG-AI achieved AUROC, sensitivity, specificity, and PPV of 0.94, 0.81, 0.91, and 69%, respectively, whereas the same for LVH ECG-AI were 0.75, 0.73, 0.68, and 31%. ECGs positive for HCM exhibited higher P wave area, QRS deflection and R wave amplitude compared to LVH-positive ECGs (Cohen's D > 0.75). ECGs positive for CA exhibited lower R wave amplitude/area, QRS deflection and QRS areas (Cohen's D > 0.6). Conclusion: Models trained using carefully labeled HCM or CA identify distinct signals associated with the diseases, resulting in improved disease discrimination compared to a model trained to identify echocardiographic left ventricular thickening. Labeling choices should be communicated transparently to clinicians to ensure safe and effective use of ECG-AI.
Abstract 18324: Artificial Intelligence ECG as a Novel Method to Detect Cardiotoxicity After Anthracyclines
Jacobs, J. , Greason, Grace , Willems, Rik , Janssens, Stefan , Voigt, Jens‐Uwe , Friedman, Paul A. , Aelst, Lucas Van , Herrmann, Joerg , Jacobs, Johanna E J , Van Aelst, Lucas N L , Voigt, Jens-Uwe , Wildiers, Hans , Noseworthy, Peter A. , López-Jiménez, Francisco , Vandenberk, Bert , Attia, Zachi I.

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.18324 Get It

Introduction: Cardiotoxicity is a serious side effect of anthracycline treatment, most commonly manifesting as a reduction in left ventricular ejection fraction (LVEF) on cardiac imaging. Cost-effective alternatives to cardiac imaging are currently not available. Artificial intelligence (AI) models have been developed to detect a reduced LVEF from 12-lead electrocardiograms (ECGs) in the general population. Hypothesis: AI-ECG model can detect a reduced LVEF after anthracycline therapy (i.e. cardiotoxicity). Methods: We included an unbiased oncological population of 989 female breast cancer patients receiving (neo)adjuvant anthracycline chemotherapy. Average follow-up time was 9.83±4.2 years. Patients with incomplete transthoracic echocardiography (TTE) data, HER-2-directed therapy, significant comorbidities, upfront metastatic disease, second primary malignancy or pre-existing cardiovascular disease were excluded from the analyses. Patients with LVEF decline for reasons other than anthracycline-induced cardiotoxicity were also excluded. Primary readout was the diagnostic performance of AI-ECG by area under the curve (AUC) for various levels of LVEF <50%. Results: Using 1,877 ECGs from 703 unique patients, the AI-ECG model detected an LVEF <50% and ≤35% after anthracycline therapy with an AUC of 0.93 and 0.94, respectively. Conclusions: These data support the use of AI-ECG for cardiomyopathy (cardiotoxicity) screening after anthracycline-based chemotherapy. This technology could serve as a gatekeeper to more costly testing and could enable patients to monitor themselves over long periods of time.
Abstract 18080: Pediatric Sex Detection Through AI-Enabled ECG Analysis: Evaluating Accuracy and the Influence of Pubertal Development
O’Sullivan, Donnchadh , Anjewierden, Scott , Greason, Grace , Friedman, Paul A. , Anderson, Jason, Kashou, Anthony H. , Eidem, Benjamin W., Johnson, Jonathan N. , Madhavan, Malini , Attia, Zachi I. , López-Jiménez, Francisco , Noseworthy, Peter A. , Anderson, Jason, Niaz, Talha

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.18080 Get It

Introduction: Biologic sex and hormonal concentrations shape ECG parameters due to sex hormone effects on cardiac function. AI-enabled ECGs have previously been shown to accurately predict patient sex in adults and correlate with sex hormone levels. Aims: We aimed to test the ability of AI-enabled ECGs to predict pediatric patient sex and explore the influence of pubertal development. Methods: Two AI-enabled ECG models were created using a convolutional neural network trained on pediatric 10-second, 12-lead surface ECGs. The first model was trained de novo using pediatric data. The second model used transfer learning from a previously validated adult data-derived algorithm. We analyzed the first ECG from 89,063 pediatric patients (aged <19 years) recorded from 1988-2022, and divided the cohort into training, validation, and testing datasets. Subgroup analysis was performed on prepubertal (0-7 years), pubertal (8-14 years), and post-pubertal (15-18 years) patients. Results: The cohort consisted of 46.6% males, with 21,434 prepubertal, 26,300 pubertal, and 41,329 post-pubertal children. No significant performance difference was observed between the two models. Both models demonstrated 81% accuracy and an overall AUC of 0.91 in the testing cohorts, with high discriminatory ability in post-pubertal teenagers (AUC = 0.98). (Figure 1) Conclusions: AI-ECG predicts pediatric patient sex with varying performance across pubertal stages. The highest discriminatory ability is observed post-puberty, decreasing in pubertal and prepubertal children. The results suggest hormonal and physiological changes during puberty may influence cardiac electrophysiology measurably. More research is required to interpret CNN-predicted sex discordance with actual sex and its implications for future cardiovascular risk.
Abstract 17454: Development and Validation of an Artificial Intelligence 12-Lead Electrocardiogram-Based Mutation Detector for Congenital Long QT Syndrome
Friedman, Paul A. , Ackerman, Michael J. , Bos, J. Martijn , Liu, Kan , Attia, Zachi I. , Noseworthy, Peter A.

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.17454 Get It

Introduction: Over 100 FDA-approved medications, electrolyte perturbations, and many disease states can prolong the QT interval in up to 10% of patients. In contrast, approximately 1 in 2,000 people have congenital long QT syndrome (LQTS) hallmarked by pathological QT prolongation secondary to LQTS-causative mutations. Hypothesis: an artificial intelligence (AI) deep neural network (DNN) analysis of the 12-lead ECG can distinguish patients with LQTS from those with acquired QT prolongation. Methods: The study cohort included 1599 patients with genetically confirmed LQTS and over 2.5 million controls from Mayo Clinic’s ECG data vault. Every patient/control with ≥ 1 ECG above age- and sex- specific 99 th percentile values for QTc [> 460 ms for all patients (male/female) < 13 years of age, or > 470 ms for men and > 480 ms for women above this age] was included. An AI-DNN involving a multi-layer convolutional neural network was developed. To simulate screening conditions, patients were matched at a ratio of 1:2,000 (incidence of LQTS) or 1:200 (balance of LQTS vs acquired QT prolongation in a tertiary referral center). Results: Among the 1,599 patients with LQTS, 808 (> 50%) had ≥ 1 ECG with QTc above the aforementioned QTc thresholds (2,987 ECGs) compared to 361,069/2.5M controls (14% of Mayo Clinic patients getting an ECG, 989,313 ECGs). Following age- and sex- matching and splitting, the model successfully distinguished LQTS from those with acquired QT prolongation at 1:2,000 matching with an AUC of 0.937 (accuracy 89%, sensitivity 81%, specificity 90%, PPV 0.05, NPV 0.99). Furthermore, when matching at a rate that genetically-mediated QT prolongation would be encountered in clinic (1:200), the model still successfully separated the two groups (AUC 0.912, accuracy 88%, sensitivity 78%, specificity 89%, PPV 0.1, NPV 0.99). Conclusion: For patients with a QTc exceeding its 99 th percentile values seen in health, this novel AI-DNN 12-lead ECG distinguishes abnormal QT prolongation stemming from LQTS versus acquired QT prolongation with high performance characteristics (AUC > 0.93). Even when scaled to referral center and LQTS incidence ratios, a negative AI-DNN signal rules out the presence of a LQTS disease-causative mutation with 99% negative predictive value.
Abstract 17189: Association Between an Artificial Intelligence-Enabled ECG Algorithm for Detection of Atrial Fibrillation While in Sinus Rhythm, and Hospitalization for Recurrent Ischemic Stroke in the Community
Sheffeh, Mohammad Ali , Brown, Robert D. , Klaas, James P. , Koriesh, Ahmed, Medina-Inojosa, Betsy, Mangold, Kathryn, Estrada-Magana, Andres , Friedman, Paul A. , Medina‐Inojosa, José R. , Medina‐Inojosa, Betsy J. , Rabinstein, Alejandro A. , Noseworthy, Peter A. , Attia, Zachi I. , López-Jiménez, Francisco

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.17189 Get It

Introduction: Artificial Intelligence-enabled electrocardiogram (AI-ECG) can estimate the probability of having atrial fibrillation (AFib) while in sinus rhythm. Recurrent stroke in subjects without known AFib may be due to undiagnosed AFib. We evaluated the association between AI-ECG AFib and recurrent ischemic stroke and with incident AFib Methods: Consecutive adults admitted to a Mayo Clinic or Mayo Clinic Health System hospital or to Olmsted Community Hospital for ischemic stroke between January,1,2000 and June,30,2022 were identified using the Rochester Epidemiology Project. Recurrent ischemic strokes were identified after reviewing medical records and imaging studies. We excluded those with known AFib or without ECGs within 3 years prior to the first ischemic stroke. The AI-ECG network was previously developed using 649,931 ECGs from > 180,000 subjects. The primary endpoint was recurrent ischemic stroke; secondary endpoint was incident AFib. Cox model adjusted for age, sex, and CHA2DS2-VASc2 score variables. Results: We included 4,816 subjects, mean age 70±15 yr, 54% male, 92% white, median CHA2DS2-VASc2 score 4 [3-5], median follow-up 3 [1-7] yr. 280 subjects (6%) had a second stroke and 366 (8%) were diagnosed with incident AFib over follow-up. Those with a positive AI-ECG AFib had an increased risk for recurrent ischemic stroke(HR 1.54, 95% CI 1.21-1.96, P<0.001 Figure A) This association remained significant after adjustment for CHA2DS2-VASc2 score(HR 1.37 95% CI 1.07-1.76, P=0.01). These associations were not affected by anticoagulation use over follow-up. AI-ECG AFib was also associated with incident AFib(HR 2.42 95% CI 1.96-2.98, P<0.001 Figure B) Conclusions: AI-ECG AFib predicts recurrent ischemic stroke in the community, possibly reflecting undiagnosed AFib that can be detected by AI-ECG, as it also predicts incident AFib. These results underscore the potential utility of AI-ECG for risk stratification of patients with ischemic stroke.
Abstract 15584: Artificial Intelligence-Guided Screening for Atrial Fibrillation Detection Among Patients With Different Socioeconomic Status
Kalinoski-DuBose, Victoria , Deng, Yihong, Graff‐Radford, Jonathan , Yao, Xiaoxi , Noseworthy, Peter A. , Deng, Yihong , Attia, Zachi I. , López-Jiménez, Francisco , Gersh, Bernard J.

Circulation | December 19, 2023 | Volume: 148 | Issue: Suppl_1 | Pages: No page available

10.1161/circ.148.suppl_1.15584 Get It

Introduction: Recently, an artificial intelligence (AI) algorithm was validated for identifying ECG signatures of atrial fibrillation (AF) risk during normal sinus rhythm. Traditionally, socioeconomically disadvantaged populations are less likely to receive novel or guideline-recommended treatments, and have high chronic disease burden, including cardiovascular diseases. There have also been concerns about new technologies creating a digital divide, worsening existing health disparities. Hypothesis: An AI algorithm will detect AF risk unequally across patients with different levels of social determinants of health (SDOH). Methods: The initial prospective, non-randomized, interventional study leveraged EHR and digital technologies to prospectively enroll 1004 patients with a broad range of AI-ECG risks of AF, who received continuous cardiac rhythm monitoring for up to 30 days. The Area Deprivation Index (ADI) was used as a composite measure of SDOH which is comprised of indicators spanning four domains: income, education, employment, and house quality. 904 intervention patients linked to the ADI data were matched to 904 real-world control patients derived from eligible but unenrolled patients. Those with ADI under 33% were defined as having better SODH; and patients with ADI above 33% were defined as having worse SODH. Results: Median age was 74 years and 38% were women. After matching, the intervention and control arms were balanced in all baseline characteristics, including HF, HTN, diabetes, stroke, CAD and ADI. A hazard ratio of 3.11 (P<0.001) was computed when comparing intervention to control for primary AF diagnosis outcome. In patients with worse SDOH, the intervention increased AF detection from 2.6% to 8.8% (HR 3.63 [2.09, 6.32]); in the better SDOH, the intervention increased AF detection from 3.9% to 9.3% (2.41 [1.23, 4.74]). Conclusions: An AI-guided AF screening program increased the detection of AF in both patients with better or worse SDOH. The current study validates the use of AI in historically disadvantaged populations displaying the possibility for broad implementation with decreased possibility of perpetuating disparities.