Citations

Mayo Clinic

Showing 10 of 108611 citations.

Using Antibodies to Make Images
Carmichael, Stephen W.

Microscopy Today | March 14, 2018 | Volume: 8 | Issue: 3 | Pages: 3-7

10.1017/s1551929500061010 Get It

Abstract The atomic force microscope (AFM), the workhorse of scanning probe microscopes, has become even more versatile. Anneliese Raab, Wenhai Han, Dirk Badt, Sandra Smith-Gill, Stuart Lindsay, Hansgeorg Schindler, and Peter Hinterdorfer have demonstrated that the AFM, in the dynamic force mode, can use antibodies as a probe. Dynamic force microscopy uses a magnetized tip that is oscillated in an alternating magnetic field as the tip scans the surface. This provides a very gentile interaction that can be recorded as a high resolution topographic image. Raab et al., showed that more information can be obtained from the specimen.
Unfolding and Folding Proteins
Carmichael, Stephen W.

Microscopy Today | March 14, 2018 | Volume: 13 | Issue: 1 | Pages: 3-7

10.1017/s155192950005077x Get It

Abstract The atomic force microscope (AFM) is being utilized in even more clever ways to reveal details of molecular structure and function. As an example, Julio Fernandez and Hongbin Li have used the AFM in the force-clamp mode to monitor the folding trajectory of a single protein. They have demonstrated in a unique way in which a single protein behaves when put under tension, and then what happens when the tension is relieved. Fernandez and Li linked several molecules of ubiquitin, a small protein, together to form a polyubiquitin chain. With one end of the chain attached to a substrate, the tip of a soft cantilever of the AFM attached to a single protein, and from one to nine ubiquitin molecules were picked up.
Watching Neurons Hand Off Molecules
Carmichael, Stephen W.

Microscopy Today | March 14, 2018 | Volume: 10 | Issue: 1 | Pages: 3-34

10.1017/s1551929500050422 Get It

Abstract Since the discovery of nerve growth factor, it has been thought that neurotrophic factors are released or secreted from target cells. However, more recently it has been suggested that a specific neurotrophic factor known as brain-derived neurotrophic factor (BDNF) may reach target cells directly from pre-synaptic axons. It has not been known how these molecules get from the neuron in which they are produced to the target cells. Keigo Kohara, Akihiko Kitamura, Mieko Morishima, and Tadaharu Tsumoto have demonstrated that BDNF is transported anterogradely from presynaptic neurons to target neurons.
Nanostructures Require Nanomeasurements
Carmichael, Stephen W.

Microscopy Today | March 14, 2018 | Volume: 8 | Issue: 5 | Pages: 3-7

10.1017/s1551929500065160 Get It

Abstract Nanofabrication is upon us. But engineers require measurements of physical properties of their materials in order to use them appropriately. Because the size of the object is in the nanometer scale, tiny measuring devices are required. Furthermore, there is the problem of reading these tiny devices. Zhong Lin Wang, Philippe Poncharal, and Walter de Heer at Georgia Tech have solved this problem by using the transmission electron microscope (TEM) to read off the measurements. A special device was designed to fit inside the TEM, allowing for simultaneous visualization and manipulation of a nanostmcture. The nanostructure that Wang ef al, used was the carbon nanotube which could be clearly visualized by the TEM and has a well-defined structure. Specifically, they used multiwalled nanotubes with diameters of 5 to 50 nm and lengths of 1 to 20 μm. The device they designed for in situ microscopy was a modified specimen holder that allowed carbon nanotubes to be mounted in a conducting medium and positioned across from a counter electrode, which was a droplet of mercury or gold/ platinum balls.
Out with the Old, In with the New
Carmichael, Stephen W.

Microscopy Today | March 14, 2018 | Volume: 11 | Issue: 1 | Pages: 3-4

10.1017/s1551929500052251 Get It

Abstract Temporal resolution has long been a challenge to microscopists. Certainly, spatial resolution has occupied center stage, but we're all concerned about what happens over time in a biologic system, for example, a cell. Tags such as green fluorescent protein (GFP) have been used with confocal microscopy and other light microscopic techniques to achieve outstanding temporal resolution, but good spatial and temporal resolution have proven to be difficult to achieve simultaneously. This has been accomplished in a remarkable study by Guido Gaietta, Thomas Deerinck, Stephen Adams, James Bouwer, Oded Tour, Dale Laird, Gina Sosinsky, Roger Tsien, and Mark Ellisman, who demonstrated a pulse-chase technique that correlates with both fluorescence and electron microscopy.
Unzipping a Membrane
Carmichael, Stephen W., Fernández, Julio M.

Microscopy Today | March 14, 2018 | Volume: 8 | Issue: 9 | Pages: 3-7

10.1017/s1551929500059368 Get It

Abstract The atomic force microscope (AFM) is well known for its outstanding spatial resolution, but it is becoming increasingly useful as the instrument for force spectroscopy. In the force spectroscopy mode, the AFM can measure tiny tension forces, in the piconewton (pN) range. Daniel Müller, Wolfgang Baurmeister, and Andreas Engel have used the AFM in both the imaging and force spectroscopy modes to pull proteins out of membranes in a controlled fashion. Müller et al. used Deinococcus radiodurans, a bacterium best known for its high resistance to radiation (as its Genus name implies), as their test subject. They extracted a highly regular membrane from the bacterium, the hexagonally packed intermediate (HPl) layer. They mounted the HPI on mica, so that the hydrophilic outer surface of the HPI adsorbed strongly to the mica, exposing the hydrophobic inner surface to the silicon nitride AFM stylus.
Directly Reading The Genome
Carmichael, Stephen W., Maihle, Nita J.

Microscopy Today | March 14, 2018 | Volume: 9 | Issue: 2 | Pages: 3-7

10.1017/s1551929500056388 Get It

Abstract The code for the human genome is essentially complete, opening an expansive book about our biologic composition. But the problem is to read this book. The font size is very small, What you are reading now is 9 point font, and genetic information would correspond to approximately 10-50 point font, six orders of magnitude smaller. There are methods to derive genetic information, but recently Adam Woolley, Chantal Guillemette, Chin-Li Cheung, David Housman, and Charles Lieber have developed an elegant way to directly read genetic information with a microscope. The microscope they used was an atomic force microscope (AFM) that employed a single-walled carbon nanotube as its probe.
Typing Blood Cells, One At A Time
Carmichael, Stephen W.

Microscopy Today | March 14, 2018 | Volume: 8 | Issue: 7 | Pages: 3-7

10.1017/s1551929500054602 Get It

Abstract We are all familiar with the 4 groups of human blood types; 0, A, B, and AB. Each group is characterized by specific molecules on the surface of the red blood cells (RBCs). Recently, Michel Grandbois, Wolfgang Dettmann, Martin Benoit, and Hermann Gaub have modified the atomic force microscope (AFM) to use the different affinities of these molecules to produce an image. A key step was to specifically functionalize the scanning probe tip of the AFM. What this means is to covalently attach an active molecule to the tip. The active molecule they used was a Iectin derived from the snail Helix pomatia (this is the same snail valued by the French as escargot). This Iectin binds specifically to molecules found on the surface of RBCs in blood group A (N-acetylgalactosamine-terminated glycolipids), but these molecules are not found in blood group O. But if the Iectin was bound directly to the AFM tip, nonspecific adsorption to the specimens would occur.
Cell-Free Secretion
Carmichael, Stephen W.

Microscopy Today | March 14, 2018 | Volume: 8 | Issue: 4 | Pages: 3-7

10.1017/s1551929500063392 Get It

Abstract Regulated secretion occurs when the ceil detects a signal, vesicles containing the secretory product fuse with the plasma membrane of the cell, and the contents are released into the extracellular space. This mechanism is called exocytosis. Many laboratories around the world have studied exocytosis for the past couple of decades, and we know a lot about the many steps that are involved. The cytoskeleton appears to play a role in allowing vesicles to approach the plasma membrane, and many other proteins are in the cascade between reception of the signal and the release of the secretory products.
Do Pathologists Use The Electron Microscope Enough?
Carmichael, Stephen W.

Microscopy Today | March 14, 2018 | Volume: 9 | Issue: 1 | Pages: 3-7

10.1017/s1551929500051282 Get It

Abstract The compound light microscope has been used by patholo gists for centuries, and remains the common tool for making a diagnosis. A half century ago, the electron microscope (EM) was introduced, and has aiso been proven to be a valuable, but expensive, tool. In the meantime, other tools and methods have worked their way into the pathologists’ armamentarium, with immunohistochemical, genetic, and molecular techniques being the most obvious examples. Josep Lloreta-Truil, Lola Ferrer, Teresa Ribalta, Marco Pavesi, and Sergio Serrano examined the literature to determine the frequency and appropriateness with which pathologists use the EM in their studies.