Background— QRS prolongation is associated with adverse outcomes in mostly white populations, but its clinical significance is not well established for other groups. We investigated the association between QRS duration and mortality in African Americans. Methods and Results— We analyzed data from 5146 African Americans in the Jackson Heart Study stratified by QRS duration on baseline 12-lead ECG. We defined QRS prolongation as QRS≥100 ms. We assessed the association between QRS duration and all-cause mortality using Cox proportional hazards models and reported the cumulative incidence of heart failure hospitalization. We identified factors associated with the development of QRS prolongation in patients with normal baseline QRS. At baseline, 30% (n=1528) of participants had QRS prolongation. The cumulative incidences of mortality and heart failure hospitalization were greater with versus without baseline QRS prolongation: 12.6% (95% confidence interval [CI], 11.0–14.4) versus 7.1% (95% CI, 6.3–8.0) and 8.2% (95% CI, 6.9–9.7) versus 4.4% (95% CI, 3.7–5.1), respectively. After risk adjustment, QRS prolongation was associated with increased mortality (hazard ratio, 1.27; 95% CI, 1.03–1.56; P =0.02). There was a linear relationship between QRS duration and mortality (hazard ratio per 10 ms increase, 1.06; 95% CI, 1.01–1.12). Older age, male sex, prior myocardial infarction, lower ejection fraction, left ventricular hypertrophy, and left ventricular dilatation were associated with the development of QRS prolongation. Conclusions— QRS prolongation in African Americans was associated with increased mortality and heart failure hospitalization. Factors associated with developing QRS prolongation included age, male sex, prior myocardial infarction, and left ventricular structural abnormalities.
Infusion technique of hematopoietic progenitor cells and related adverse events (CME)
BackgroundThe use of hematopoietic progenitor cell (HPC) transplant has risen over the past two decades. A variety of adverse events (AEs) of varying severity have been noted during HPC infusions. These AEs have been associated with several factors such as the amount of dimethyl sulfoxide and white blood cells in the HPC product. We performed a single‐institution retrospective analysis to determine the effect of two different HPC infusion techniques, manual push with syringes versus infusion from bags with the aid of gravity, on the occurrence of infusion‐related AEs.Study Design and MethodsInfusions between December 2008 and November 2010 involving peripheral blood HPCs were reviewed. Pertinent clinical and HPC product–related information was recorded. Data were analyzed to determine the incidence of infusion‐related AEs and its association with patient and product‐related variables.ResultsWe found 461 AEs in 645 patients during the study period. A total of 325 (50%) experienced at least one AE. Flushing was the most common type of AE followed by nausea and hypertension. The use of syringe infusion was more commonly associated with AEs (odds ratio, 1.82 [95% confidence interval, 1.32‐2.50]; p = 0.002). Other independent risk factors were cryopreserved products and the amount of polymorphonuclear leukocytes in the product.ConclusionTo our knowledge, this is the first study examining the effect of two different infusion techniques on infusion‐related AEs. Our findings suggest that the use of bags for infusion protected the patients from AEs.
Defining a reference range for cold agglutinin titers
BackgroundThe cold agglutinin (CAGG) titer is offered at our institution to aid in diagnosing cold agglutinin disease (CAD). Our goal was to create a seasonally adjusted reference range using prospective samples and compare it to a reference range generated retrospectively.Study Design and MethodsProspective CAGG titer testing was performed on healthy blood donors. Retrospective electronic analysis was performed on patients in two groups defined by current and historical testing methods. Blood donor testing was performed in January and July to determine if seasonal variation existed. Retrospective patients with conditions associated with CAD were excluded from analysis. Additional prospective CAGG testing using reference range program volunteers was performed to verify blood donor and patient result differences.ResultsTiters from the blood donor and patient cohorts had no age association (p > 0.44). Titers from those same cohorts did not show winter/summer variation (p > 0.11). No sex association was found with titer reference ranges in the blood donor and historical patient cohort. A sex association was found with titers in the current method patient cohort (male 64 to 512 and female ≤64; p < 0.0001). Blood donor CAGG titer lower 95% reference range was not more than 4 while historical and current patient cohorts ranges were not more than 32 and not more than 64, respectively. Reference range volunteers confirmed the narrow reference range in healthy individuals when compared to patients and blood donors.ConclusionProspective blood donor CAGG titers were lower than retrospective patient cohorts. This may be due to blood donors representing a healthier population than the patient cohorts.
Discordant CD34+ cell results in peripheral blood and hematopoietic progenitor cell–apheresis product: implications for clinical decisions and impact on patient treatment
Case ReportA 50‐year‐old male with T‐cell lymphoma presented for autologous peripheral blood stem cell transplantation. After granulocyte–colony‐stimulating factor (G‐CSF) mobilization, his peripheral blood CD34+ cell count was 166 × 106/L on the day before collection, which predicted a high yield of CD34+ cells in the apheresis product. The first two collections had yields much lower than expected, triggering an investigation and changes to the apheresis collection methods since mobilization appeared adequate from the peripheral CD34+ values.ResultsChanges to the apheresis collection variables and instrumentation did not improve the yields in the next three collections. The laboratory investigation demonstrated that there was an interfering substance in the patient's plasma that was causing falsely high peripheral blood CD34+ cell values and that the low CD34+ cell yields in the collections were consistent with the actual peripheral blood CD34+ cell value. Based on this finding and after discussion with the clinical service, the patient then received plerixafor to increase the number of circulating CD34+ cells before Collections 6 and 7. The patient went on to achieve the target CD34+ cell dose and subsequently underwent a successful autologous transplant with full hematopoietic engraftment.ConclusionThis case demonstrates the importance of timely and critical review of laboratory results in the context of the specific patient. This case exemplifies how diligent review of laboratory results and open communication among the various teams can positively affect patient outcomes.