The technique of surgical repair for zone two flexor tendon injuries has been debated extensively throughout the years, yet adhesion formation, suture rupture, and suture locking on the pulley edge remain possible consequences of a poor repair. The partially lacerated tendon is especially challenging to treat since there can be justification for not intervening surgically. In a partial laceration canine model we measured failure load and suture gap formation for tendons repaired with the Lee, modified four-strand Savage, Kessler, modified Kessler, and Augmented Becker core suture techniques and with a simple running peripheral suture. The modified Kessler (106.3 N, SD 18.8 N) and modified Savage (108.2 N, SD 19.9 N) repair techniques had a significantly higher failure load than the Lee (85.0 N, SD 20.6 N) suture method p<0.05, while there were no differences among the other techniques. There were no significant differences in resistance to gap formation among the repair techniques, with the mean values ranging from 38.9 N/mm (SD 15.7 N/mm) using the simple running suture to 53.2 N/mm (SD 25.8 N/mm) with the Kessler repair. The mean load to produce a 1.5 mm repair site gap ranged from 71.1 N (SD 21.5 N) in the Lee repair to 91.3 N (SD 22.2 N) in the Augmented Becker repair although there were no significant differences among repair methods. All repair methods were much weaker than tendons left unrepaired (184.7 N, SD 41.3 N). [S0148-0731(00)00706-8]
Determination of the Compressive Material Properties of the Supraspinatus Tendon
A methodology was developed for determining the compressive properties of the supraspinatus tendon, based on finite element principles. Simplified three-dimensional models were created based on anatomical thickness measurements of unloaded supraspinatus tendons over 15 points. The tendon material was characterized as a composite structure of longitudinally arranged collagen fibers within an extrafibrillar matrix. The matrix was formulated as a hyperelastic material described by the Ogden form of the strain energy potential. The hyperelastic material parameters were parametrically manipulated until the analytical load-displacement results were similar to the results obtained from indentation testing. In the geometrically averaged tendon, the average ratio of experimental to theoretical maximum indentation displacement was 1.00 (SD: 0.01). The average normalization of residuals was 2.1g (SD: 0.9g). Therefore, the compressive material properties of the supraspinatus tendon extrafibrillar matrix were adequately derived with a first-order hyperelastic formulation. The initial compressive elastic modulus ranged from 0.024 to 0.090 MPa over the tendon surface and increased nonlinearly with additional compression. Using these material properties, the stresses induced during acromional impingement can be analyzed.
Dynamic Pressure Transmission Through Agarose Gels
An optical spin micromotor operated by optical tweezers, described in the present study, converts radiant energy directly to mechanical energy. This conversion is of great practical and fundamental interest. The optical spin micromotor consists of a two-bead linkage. The large bead (2.0 μm in diameter) is trapped by the optical tweezers and rotates around the laser beam axis. The small bead (0.94 μm in diameter) is partially coated with gold/palladium for generating the spin torque through the change of momentum from gradient radiation pressure of the same laser applied on the coated small bead. With a laser power of 29 mW at the sample plane, the spin speed averaged 158.8±155.5 rpm (mean±standard deviation) and the torque was estimated as 101.9±99.8 pN nm. This optical spin micromotor will be useful in (1) providing a fundamental step toward developing optical-operated mechanical devices, (2) twisting macromolecules, and (3) generating vortex and shear force in medium at nanoscale.